Test Report

FCC ID: PQN44497RX2G4

Test Report

Download: PDF
FCCID_2645322

 Intertek
Valued Quality. Delivared.




                                                                                                                                                                O‘\sfl
Issuing Laboratory:




                                                                                                                                                                         \
                                                                                                                                                                        1 |
Intertek Testing Services Hong Kong Limited




                                                                                                                                                           t
HKAS has accrediled this laboratory (HOKLAS 005 — TEST) under HOKLAS for specific
laboratory activitles as listed in the HOKLAS directory of accradited Iaboratories.




                                                                                                                                               &
                                                                 TEST REPORT

                                              Report No.: 15031419HKG—003

                                              Spin Master Toys Far East Ltd.


                                                                      Application
                                                                           For
                                                                      Certification
                                                        (Original Grant)
                                                  (FCC ID; PQNA44497RX2G4)

                                                                      Transceiver




Prepared and Checked by:                                                                   Approved by:



                                                                                                                   /4// is
Wong Kwok Yeung, Kenneth                                                                    Chian Chi Hung, Terry
Lead Engineer                                                                               Senior Supervisor
                                                                                            Date: April 27, 2015




    Intertek‘s standard Terms and Conditions can be oblained al our website hitp:l/www.nlertek.com/ierma/,
    This report shul} not be reproduced, axcapt in full.
    This report In for the excluaive use of Intertak‘s Client ind iz provided putauaint to the agreement between Intertek and its Cliant. Intertek‘s reaponsibillty and
    fiabilty. ara fimiled to the terms. und condifiona of the agresmant. Intertok nxoumea no liabifty to any parly, other than to the Client in accordance with the
    apresment, for any leas, exponse or damage octasloned by the use of this report. Only the Client is aulhorizad to permit copying or diatributlon of this report and
    than only in IIs enliroty. Any use of tha Interlok name or one of Its marke for the anla or adveriizement of the tesled material, product or service must first be
    mpproved in writing by Interiak, The observations and teat reaulls in this report are reievant only to the aample leled. This report by llaeif does not Imply that the
    aluria}, product, or sarvice is or has aver been under an Interlek cartification program.


Issuing Laboratory:
Intertek Testing Services Hong Kong Limited
HKAS has accredited this laboratory (HOKLAS 005 – TEST) under HOKLAS for specific
laboratory activities as listed in the HOKLAS directory of accredited laboratories.




                                             GENERAL INFORMATION


 Grantee:                                        Spin Master Toys Far East Ltd.
 Grantee Address:                                Room 1113, 11/F., Chinachem Golden Plaza,
                                                 77 Mody Road, Tsim Sha Tsui East,
                                                 Kowloon, Hong Kong.
 Contact Person:                                 Andy Wong
 Tel:                                            0769-81080068-1123
 Fax:                                            0769-81080061
 e-mail:                                         andyw@spinmaster.com
 Manufacturer:                                   Spin Master Toys
 Manufacturer Address:                           Room 1113A,11/F,Chinachem Golden Plaza,
                                                 77 Mody Road, Tsim Sha Tsui East,
                                                 Kowloon,Hong Kong
 Brand Name:                                     AIR Hogs
 Model:                                          44497
 Type of EUT:                                    Transceiver
 Description of EUT:                             ARH RDC Helix Video Drone
 Serial Number:                                  N/A
 FCC ID:                                         PQN44497RX2G4
 Date of Sample Submitted:                       March 31, 2015
 Date of Test:                                   March 31, 2015 to April 24, 2015
 Report No.:                                     15031419HKG-003
 Report Date:                                    April 27, 2015
 Environmental Conditions:                       Temperature: +10 to 40°C
                                                 Humidity: 10 to 90%




Report No.: 15031419HKG-003                                                                                  i
FCC ID: PQN44497RX2G4
                                         Intertek Testing Services Hong Kong Ltd.
                                     2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                           Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com


Issuing Laboratory:
Intertek Testing Services Hong Kong Limited
HKAS has accredited this laboratory (HOKLAS 005 – TEST) under HOKLAS for specific
laboratory activities as listed in the HOKLAS directory of accredited laboratories.




                                         SUMMARY OF TEST RESULT


                           TEST SPECIFICATION                                              REFERENCE RESULTS
 Transmitter Field Strength and Bandedge Requirement                                             15.249      Pass
 Radiated Emission in Restricted Bands                                                           15.205      Pass

The equipment under test is found to be complying with the following standards:
FCC Part 15, October 1, 2013 Edition




 Note: 1. The EUT uses a permanently attached antenna which, in accordance to section 15.203, is
          considered sufficient to comply with the pervisions of this section.
       2. Pursuant to FCC part 15 Section 15.215(c), the 20 dB bandwidth of the emission was contained
          within the frequency band designated (mentioned as above) which the EUT operated. The
          effects, if any, from frequency sweeping, frequency hopping, other modulation techniques and
          frequency stability over excepted variations in temperature and supply voltage were considered.




Report No.: 15031419HKG-003                                                                                         ii
FCC ID: PQN44497RX2G4
                                         Intertek Testing Services Hong Kong Ltd.
                                     2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                           Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com


Issuing Laboratory:
Intertek Testing Services Hong Kong Limited
HKAS has accredited this laboratory (HOKLAS 005 – TEST) under HOKLAS for specific
laboratory activities as listed in the HOKLAS directory of accredited laboratories.




                                                    Table of Contents

1.0   General Description .............................................................................................. 1
  1.1  Product Description ............................................................................................. 1
  1.2  Related Submittal(s) Grants................................................................................. 1
  1.3  Test Methodology ................................................................................................ 1
  1.4  Test Facility ......................................................................................................... 1

2.0   System Test Configuration................................................................................... 2
  2.1   Justification.......................................................................................................... 2
  2.2   EUT Exercising Software..................................................................................... 2
  2.3   Special Accessories ............................................................................................ 2
  2.4   Measurement Uncertainty.................................................................................... 2
  2.5   Support Equipment List and Description.............................................................. 2

3.0   Emission Results .................................................................................................. 3
  3.1  Field Strength Calculation.................................................................................... 3
  3.2  Radiated Emission Configuration Photograph ..................................................... 4
  3.3  Radiated Emission Data ...................................................................................... 4

4.0       Equipment Photographs....................................................................................... 8

5.0       Product Labelling.................................................................................................. 8

6.0       Technical Specifications ...................................................................................... 8

7.0       Instruction Manual ................................................................................................ 8

8.0   Miscellaneous Information ................................................................................... 9
  8.1   Radiated Emission on the Bandedge................................................................... 9
  8.2   Discussion of Pulse Desensitization .................................................................. 10
  8.3   Calculation of Average Factor............................................................................ 10
  8.4   Emissions Test Procedures ............................................................................... 12

9.0       Equipment List .................................................................................................... 15




Report No.: 15031419HKG-003                                                                                              iii
FCC ID: PQN44497RX2G4
                                         Intertek Testing Services Hong Kong Ltd.
                                     2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                           Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com


Issuing Laboratory:
Intertek Testing Services Hong Kong Limited
HKAS has accredited this laboratory (HOKLAS 005 – TEST) under HOKLAS for specific
laboratory activities as listed in the HOKLAS directory of accredited laboratories.




1.0       General Description

1.1       Product Description
          The Equipment Under Test (EUT) is a 2.4GHz Transceiver (Helicopter Unit)
          for a RC helicopter operating at 2412, 2442 and 2460MHz. The Helicopter
          Unit is operating at 2433MHz after paired with the Controller Unit. The EUT is
          powered by 1 X 3.7V rechargeable battery (Li-Poly). The EUT equipped with a
          camera for photo shooting and video recording and save the data to the
          micro-USB. After switch on the EUT and paired with controller, the EUT can
          be controlled to fly forward, backward and turning left/right direction by the
          corresponding controller. Using an USB charging cable can charge the
          internal battery in the helicopter via PC. Also, Using an USB cable can
          transfer the data, ie. Photo and vedio from the helicopter to PC.
          Antenna Type: Internal, Integral
          For electronic filing, the brief circuit description is saved with filename: descri.pdf.


1.2       Related Submittal(s) Grants
          The Certification procedure of transceiver (Controller) for this transceiver
          (Helicopter) with FCC ID: PQN44497TX2G4 is being processed as the same
          time of this application.

1.3       Test Methodology
          Radiated emission measurements were performed according to the
          procedures in ANSI C63.4 (2009).          All radiated measurements were
          performed in an 3m Chamber. Preliminary scans were performed in the
          3m Chamber only to determine worst case modes. All radiated tests were
          performed at an antenna to EUT distance of 3 meters, unless stated
          otherwise in the “Justification Section” of this Application.


1.4       Test Facility
          The 3m Chamber measurement facility used to collect the radiated data is
          located at Workshop No. 3, G/F., World-Wide Industrial Centre, 43-47 Shan Mei
          Street, Fo Tan, Sha Tin, N.T., Hong Kong. This test facility and site
          measurement data have been placed on file with the FCC.




Report No.: 15031419HKG-003                                                                                  1
FCC ID: PQN44497RX2G4
                                         Intertek Testing Services Hong Kong Ltd.
                                     2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                           Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com


Issuing Laboratory:
Intertek Testing Services Hong Kong Limited
HKAS has accredited this laboratory (HOKLAS 005 – TEST) under HOKLAS for specific
laboratory activities as listed in the HOKLAS directory of accredited laboratories.




2.0       System Test Configuration

2.1       Justification

          The system was configured for testing in a typical fashion (as a customer would
          normally use it), and in the confines as outlined in ANSI C63.4 (2009).

          The device was powered by a fully charged 3.7V rechargeable battery.

          For maximizing emissions, the EUT was rotated through 360°, the antenna
          height was varied from 1 meter to 4 meters above the ground plane, and the
          antenna polarization was changed. This step by step procedure for maximizing
          emissions led to the data reported in Exhibit 3.0.

          The unit was operated standalone and placed in the center of the turntable.

          The equipment under test (EUT) was configured for testing in a typical fashion
          (as a customer would normally use it). The EUT was mounted to a plastic stand
          if necessary and placed on the wooden turntable, which enabled the engineer to
          maximize emissions through its placement in the three orthogonal axes.


2.2       EUT Exercising Software

          There was no special software to exercise the device.                                          Once the unit is
          powered up, it transmits the RF signal continuously.


2.3       Special Accessories

          There are no special accessories necessary for compliance of this product.


2.4       Measurement Uncertainty

          When determining of the test conclusion, the Measurement Uncertainty of test
          has been considered.


2.5       Support Equipment List and Description

          N/A.




Report No.: 15031419HKG-003                                                                                            2
FCC ID: PQN44497RX2G4
                                         Intertek Testing Services Hong Kong Ltd.
                                     2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                           Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com


Issuing Laboratory:
Intertek Testing Services Hong Kong Limited
HKAS has accredited this laboratory (HOKLAS 005 – TEST) under HOKLAS for specific
laboratory activities as listed in the HOKLAS directory of accredited laboratories.




3.0       Emission Results

          Data is included of the worst case configuration (the configuration which resulted
          in the highest emission levels). A sample calculation, configuration photographs
          and data tables of the emissions are included.


3.1       Field Strength Calculation

          The field strength is calculated by adding the Antenna Factor and Cable Factor,
          and subtracting the Amplifier Gain (if any), Average Factor (optional) from the
          measured reading. The basic equation with a sample calculation is as follows:
          FS = RA + AF + CF - AG - AV
          where          FS = Field Strength in dBµV/m
                         RA = Receiver Amplitude (including preamplifier) in dBµV
                         CF = Cable Attenuation Factor in dB
                         AF = Antenna Factor in dB
                         AG = Amplifier Gain in dB
                         AV = Average Factor in dB

          In the following table(s), the reading shown on the data table reflects the preamplifier
          gain. An example for the calculations in the following table is as follows:
          FS = RR + LF
          where           FS = Field Strength in dBµV/m
                          RR = RA - AG - AV in dBµV
                          LF = CF + AF in dB

          Assume a receiver reading of 52.0 dBµV is obtained. The antenna factor of
          7.4 dB and cable factor of 1.6 dB are added. The amplifier gain of 29 dB and
          average factor of 5 dB are subtracted, giving a field strength of 27 dBµV/m.
          This value in dBµV/m was converted to its corresponding level in µV/m.

          RA = 52.0 dBµV/m
          AF = 7.4 dB                                            RR = 18.0 dBµV
          CF = 1.6 dB                                            LF = 9.0 dB
          AG = 29.0 dB
          AV = 5.0 dB
          FS = RR + LF
          FS = 18 + 9 = 27 dBµV/m

          Level in µV/m = Common Antilogarithm [(27 dBµV/m)/20] = 22.4 µV/m




Report No.: 15031419HKG-003                                                                                  3
FCC ID: PQN44497RX2G4
                                         Intertek Testing Services Hong Kong Ltd.
                                     2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                           Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com


Issuing Laboratory:
Intertek Testing Services Hong Kong Limited
HKAS has accredited this laboratory (HOKLAS 005 – TEST) under HOKLAS for specific
laboratory activities as listed in the HOKLAS directory of accredited laboratories.




3.2       Radiated Emission Configuration Photograph

          The worst case in radiated emission was found at 4920 MHz

          For electronic filing, the worst case radiated emission configuration photographs
          are saved with filename: radiated photos.pdf.


3.3       Radiated Emission Data

          The data on the following page lists the significant emission frequencies, the
          limit and the margin of compliance. Numbers with a minus sign are below the
          limit.

          Judgment: Passed by 14.1 dB




Report No.: 15031419HKG-003                                                                                  4
FCC ID: PQN44497RX2G4
                                         Intertek Testing Services Hong Kong Ltd.
                                     2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                           Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com


Issuing Laboratory:
Intertek Testing Services Hong Kong Limited
HKAS has accredited this laboratory (HOKLAS 005 – TEST) under HOKLAS for specific
laboratory activities as listed in the HOKLAS directory of accredited laboratories.




Applicant: Spin Master Toys Far East Ltd.                                                    Date of Test: April 24, 2015
Model: 44497
Worst-Case Operating Mode: Transmitting

                                                              Table 1

                                       Radiated Emissions
                        Pursuant to FCC Part 15 Section 15.249 Requirement

Lowest Channel
                                       Pre-Amp Antenna   Net at  Average                    Calculated   Average Limit
 Polari- Frequency         Reading       Gain   Factor 3m - Peak Factor                       at 3m          at 3m       Margin
 zation     (MHz)          (dBμV)        (dB)    (dB)  (dBμV/m)    (dB)                     (dBμV/m)       (dBμV/m)       (dB)
   H      2412.000          95.4          33     29.4    91.8      44.4                       47.4            94.0       -46.6
   H      2400.000          58.4          33     29.4    54.8      44.4                       10.4            54.0       -43.6
   V      4824.000          57.3          33     34.9    59.2     44.4                        14.8           54.0        -39.2
   V      7236.000          52.4          33     37.9    57.3      44.4                       12.9            54.0       -41.1
   V      9648.000          50.0          33     40.4    57.4      44.4                       13.0            54.0       -41.0
   V     12060.000          51.0          33     40.5    58.5     44.4                        14.1           54.0        -39.9
   V     14472.000          49.6          33     40.0    56.6     44.4                        12.2           54.0        -41.8

                                                 Pre-Amp          Antenna               Net at      Peak Limit
  Polari-     Frequency           Reading          Gain            Factor             3m - Peak       at 3m          Margin
  zation         (MHz)            (dBμV)           (dB)             (dB)              (dBμV/m)      (dBμV/m)          (dB)
    H          2412.000            95.4             33              29.4                91.8          114.0          -22.2
    H          2400.000            58.4             33              29.4                54.8          74.0           -19.2
    V         4824.000             57.3             33             34.9                 59.2          74.0           -14.8
    V          7236.000            52.4             33              37.9                57.3          74.0           -16.7
    V          9648.000            50.0             33              40.4                57.4          74.0           -16.6
    V         12060.000            51.0             33             40.5                 58.5          74.0           -15.5
    V         14472.000            49.6             33             40.0                 56.6          74.0           -17.4

NOTES: 1. Peak Detector Data unless otherwise stated.
               2. All measurements were made at 3 meters. Harmonic emissions not
                  detected at the 3-meter distances were measured at 0.3-meter and an
                  inverse proportional extrapolation was performed to compare the signal
                  level to the 3-meter limit. No other harmonic emissions than those
                  reported were detected at a test distance of 0.3-meter.
               3. Negative sign in the column shows value below limit.

               4. Horn antenna is used for the emission over 1000MHz.
               5. Emission (the row indicated by bold italic) within the restricted band meets
                  the requirement of FCC Part 15 Section 15.205.

               6. Measurement Uncertainty is ±5.3dB at a level of confidence of 95%.

Report No.: 15031419HKG-003                                                                                                   5
FCC ID: PQN44497RX2G4
                                         Intertek Testing Services Hong Kong Ltd.
                                     2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                           Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com


Issuing Laboratory:
Intertek Testing Services Hong Kong Limited
HKAS has accredited this laboratory (HOKLAS 005 – TEST) under HOKLAS for specific
laboratory activities as listed in the HOKLAS directory of accredited laboratories.




Applicant: Spin Master Toys Far East Ltd.                                                    Date of Test: April 24, 2015
Model: 44497
Worst-Case Operating Mode: Transmitting

                                                              Table 2

                                       Radiated Emissions
                        Pursuant to FCC Part 15 Section 15.249 Requirement

Middle Channel
                                       Pre-Amp Antenna   Net at  Average                    Calculated   Average Limit
 Polari- Frequency         Reading       Gain   Factor 3m - Peak Factor                       at 3m          at 3m       Margin
 zation     (MHz)          (dBμV)        (dB)    (dB)  (dBμV/m)    (dB)                     (dBμV/m)       (dBμV/m)       (dB)
   H      2442.000          96.2          33     29.4    92.6      44.4                       48.2            94.0       -45.8
   V      4884.000          57.6          33     34.9    59.5     44.4                        15.1           54.0        -38.9
   V      7326.000          52.5          33     37.9    57.4     44.4                        13.0           54.0        -41.0
   V      9768.000          50.0          33     40.4    57.4      44.4                       13.0            54.0       -41.0
   V     12210.000          51.0          33     40.5    58.5     44.4                        14.1           54.0        -39.9
   V     14652.000          51.2          33     38.4    56.6      44.4                       12.2            54.0       -41.8

                                                 Pre-Amp          Antenna               Net at      Peak Limit
  Polari-     Frequency           Reading          Gain            Factor             3m - Peak       at 3m          Margin
  zation         (MHz)            (dBμV)           (dB)             (dB)              (dBμV/m)      (dBμV/m)          (dB)
    H          2442.000            96.2             33              29.4                92.6          114.0          -21.4
    V         4884.000             57.6             33             34.9                 59.5          74.0           -14.5
    V         7326.000             52.5             33             37.9                 57.4          74.0           -16.6
    V          9768.000            50.0             33              40.4                57.4          74.0           -16.6
    V         12210.000            51.0             33             40.5                 58.5          74.0           -15.5
    V         14652.000            51.2             33              38.4                56.6          74.0           -17.4

NOTES: 1. Peak Detector Data unless otherwise stated.
               2. All measurements were made at 3 meters. Harmonic emissions not
                  detected at the 3-meter distances were measured at 0.3-meter and an
                  inverse proportional extrapolation was performed to compare the signal
                  level to the 3-meter limit. No other harmonic emissions than those
                  reported were detected at a test distance of 0.3-meter.
               3. Negative sign in the column shows value below limit.
               4. Horn antenna is used for the emission over 1000MHz.
               5. Emission (the row indicated by bold italic) within the restricted band meets
                  the requirement of FCC Part 15 Section 15.205.
               6. Measurement Uncertainty is ±5.3dB at a level of confidence of 95%.




Report No.: 15031419HKG-003                                                                                                   6
FCC ID: PQN44497RX2G4
                                         Intertek Testing Services Hong Kong Ltd.
                                     2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                           Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com


Issuing Laboratory:
Intertek Testing Services Hong Kong Limited
HKAS has accredited this laboratory (HOKLAS 005 – TEST) under HOKLAS for specific
laboratory activities as listed in the HOKLAS directory of accredited laboratories.




Applicant: Spin Master Toys Far East Ltd.                                                    Date of Test: April 24, 2015
Model: 44497
Worst-Case Operating Mode: Transmitting

                                                              Table 3

                                       Radiated Emissions
                        Pursuant to FCC Part 15 Section 15.249 Requirement

Highest Channel
                                       Pre-Amp Antenna   Net at  Average                    Calculated   Average Limit
 Polari- Frequency         Reading       Gain   Factor 3m - Peak Factor                       at 3m          at 3m       Margin
 zation     (MHz)          (dBμV)        (dB)    (dB)  (dBμV/m)    (dB)                     (dBμV/m)       (dBμV/m)       (dB)
   H      2460.000          96.8          33     29.4    93.2      44.4                       48.8            94.0       -45.2
   H      2483.500          59.2          33     29.4    55.6     44.4                        11.2           54.0        -42.8
   V      4920.000          58.0          33     34.9    59.9     44.4                        15.5           54.0        -38.5
   V      7380.000          52.9          33     37.9    57.8     44.4                        13.4           54.0        -40.6
   V      9840.000          50.5          33     40.4    57.9      44.4                       13.5            54.0       -40.5
   V     12300.000          51.1          33     40.5    58.6     44.4                        14.2           54.0        -39.8
   V     14760.000          51.4          33     38.4    56.8      44.4                       12.4            54.0       -41.6

                                                 Pre-Amp          Antenna               Net at      Peak Limit
  Polari-     Frequency           Reading          Gain            Factor             3m - Peak       at 3m          Margin
  zation         (MHz)            (dBμV)           (dB)             (dB)              (dBμV/m)      (dBμV/m)          (dB)
    H          2460.000            96.8             33              29.4                93.2          114.0          -20.8
    H         2483.500             59.2             33             29.4                 55.6          74.0           -18.4
    V         4920.000             58.0             33             34.9                 59.9          74.0           -14.1
    V         7380.000             52.9             33             37.9                 57.8          74.0           -16.2
    V          9840.000            50.5             33              40.4                57.9          74.0           -16.1
    V         12300.000            51.1             33             40.5                 58.6          74.0           -15.4
    V         14760.000            51.4             33              38.4                56.8          74.0           -17.2

NOTES: 1. Peak Detector Data unless otherwise stated.
               2. All measurements were made at 3 meters. Harmonic emissions not
                  detected at the 3-meter distances were measured at 0.3-meter and an
                  inverse proportional extrapolation was performed to compare the signal
                  level to the 3-meter limit. No other harmonic emissions than those
                  reported were detected at a test distance of 0.3-meter.
               3. Negative sign in the column shows value below limit.
               4. Horn antenna is used for the emission over 1000MHz.
               5. Emission (the row indicated by bold italic) within the restricted band meets
                  the requirement of FCC Part 15 Section 15.205.
               6. Measurement Uncertainty is ±5.3dB at a level of confidence of 95%.


Report No.: 15031419HKG-003                                                                                                   7
FCC ID: PQN44497RX2G4
                                         Intertek Testing Services Hong Kong Ltd.
                                     2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                           Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com


Issuing Laboratory:
Intertek Testing Services Hong Kong Limited
HKAS has accredited this laboratory (HOKLAS 005 – TEST) under HOKLAS for specific
laboratory activities as listed in the HOKLAS directory of accredited laboratories.




4.0       Equipment Photographs

          For electronic filing, the photographs are saved with filename: external photos.pdf
          and internal photos.pdf.


5.0       Product Labelling

          For electronics filing, the FCC ID label artwork and the label location are saved
          with filename: label.pdf.


6.0       Technical Specifications

          For electronic filing, the block diagram and schematic of the tested EUT are
          saved with filename: block.pdf and circuit.pdf respectively.


7.0       Instruction Manual

          For electronic filing, a preliminary copy of the Instruction Manual is saved with
          filename: manual.pdf.

          This manual will be provided to the end-user with each unit sold/leased in the
          United States.




Report No.: 15031419HKG-003                                                                                  8
FCC ID: PQN44497RX2G4
                                         Intertek Testing Services Hong Kong Ltd.
                                     2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                           Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com


Issuing Laboratory:
Intertek Testing Services Hong Kong Limited
HKAS has accredited this laboratory (HOKLAS 005 – TEST) under HOKLAS for specific
laboratory activities as listed in the HOKLAS directory of accredited laboratories.




8.0       Miscellaneous Information

          The miscellaneous information includes details of the test procedure and
          measured bandwidth / calculation of factor such as pulse desensitization and
          averaging factor (calculation and timing diagram).


8.1       Radiated Emission on the Bandedge

          From the following plots, they show that the fundamental emissions are confined
          in the specified band (2400MHz to 2483.5MHz). In case of the fundamental
          emissions are within two standard bandwidths from the bandedge, the delta
          measurement technique is used for determining bandedge compliance.
          Standard bandwidth is the bandwidth specified by ANSI C63.4 (2009) for
          frequency being measured.

          Emissions radiated outside of the specified frequency bands, except harmonics,
          are attenuated by 50dB below the level of the fundamental or to the general
          radiated emissions limits in Section 15.209, whichever is the lesser attenuation,
          which meet the requirement of part 15.249(d).

          Lower bandedge emission

          The test data of lower bandedge emission is shown on above table 2 of page 5

          Upper bandedge emission

          The test data of upper bandedge emission is shown on above table 3 of page 7

          The resultant field strength meets the general radiated emission limit in
          Section 15.209, which does not exceed 74 dBµV/m (Peak Limit) and 54 dBµV/m
          (Average Limit).




Report No.: 15031419HKG-003                                                                                  9
FCC ID: PQN44497RX2G4
                                         Intertek Testing Services Hong Kong Ltd.
                                     2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                           Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com


Issuing Laboratory:
Intertek Testing Services Hong Kong Limited
HKAS has accredited this laboratory (HOKLAS 005 – TEST) under HOKLAS for specific
laboratory activities as listed in the HOKLAS directory of accredited laboratories.




8.2       Discussion of Pulse Desensitization

          Pulse desensitivity is not applicable for this device. The effective period (Teff)
          is approximately 0.3ms for a digital “1” bit which illustrated on technical
          specification, with a resolution bandwidth (3dB) of 1MHz, so the pulse
          desensitivity factor is 0dB.


8.3       Calculation of Average Factor

          The duty cycle is simply the on-time divided by the period:

          The duration of one cycle = 0.3 ms

          Effective period of the cycle = 2*0.3 = 0.6 ms

          DC = 0.6/100 = 0.006

          Therefore, the averaging factor is found by 20log 0.006 = -44.4dB.




Report No.: 15031419HKG-003                                                                                  10
FCC ID: PQN44497RX2G4
                                         Intertek Testing Services Hong Kong Ltd.
                                     2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                           Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com


Issuing Laboratory:
Intertek Testing Services Hong Kong Limited
HKAS has accredited this laboratory (HOKLAS 005 – TEST) under HOKLAS for specific
laboratory activities as listed in the HOKLAS directory of accredited laboratories.




          Average Factor
                                                               RBW 3 MHz      Delta 1 [T1 ]
                                                               VBW 10 MHz                 0.12 dB
                   Ref -7 dBm              * Att   10 dB       SWT 10 ms            300.000000 µs

                    -10                                                       Marker 1 [T1 ]
                                                                                        -19.73 dBm
                   1 1                                                                0.000000 s      A
                    -20                                                                              SGL
           1 AP
           CLRWR                                                                                     TRG

                    -30
                           TRG -33.2 dBm

                    -40
                                                                                                     PS

                    -50



                    -60
                                                                                                     3DB
                                                                                                     AC
                    -70



                    -80



                    -90



                    -100



                   Center 2.4326006 GHz                    1 ms/




                                                               RBW 3 MHz
                                                               VBW 10 MHz
                   Ref -7 dBm              * Att   10 dB       SWT 100 ms

                    -10

                                                                                                      A
                    -20                                                                              SGL
           1 AP
           CLRWR                                                                                     TRG
                           TRG -27.7 dBm
                    -30



                    -40
                                                                                                     PS

                    -50



                    -60
                                                                                                     3DB
                                                                                                     AC
                    -70



                    -80



                    -90



                    -100



                   Center 2.4326006 GHz                    10 ms/




Report No.: 15031419HKG-003                                                                                   11
FCC ID: PQN44497RX2G4
                                           Intertek Testing Services Hong Kong Ltd.
                                      2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                            Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com


Issuing Laboratory:
Intertek Testing Services Hong Kong Limited
HKAS has accredited this laboratory (HOKLAS 005 – TEST) under HOKLAS for specific
laboratory activities as listed in the HOKLAS directory of accredited laboratories.




8.4       Emissions Test Procedures

          The following is a description of the test procedure used by Intertek Testing
          Services Hong Kong Ltd. in the measurements of transmitter operating under
          the Part 15, Subpart C rules.

          The transmitting equipment under test (EUT) is placed on a wooden turntable
          which is four feet in diameter and approximately one meter in height above the
          ground plane. During the radiated emissions test, the turntable is rotated and
          any cables leaving the EUT are manipulated to find the configuration resulting in
          maximum emissions. The EUT is adjusted through all three orthogonal axis to
          obtain maximum emission levels. The antenna height and polarization are also
          varied during the testing to search for maximum signal levels. The height of the
          antenna is varied from one to four meters.

          Detector function for radiated emissions is in peak mode. Average readings, when
          required, are taken by measuring the duty cycle of the equipment under test and
          subtracting the corresponding amount in dB from the measured peak readings. A
          detailed description for the calculation of the average factor can be found in Exhibit 8.3.

          The frequency range scanned is from the lowest radio frequency signal
          generated in the device which is greater than 9 kHz to the tenth harmonic of the
          highest fundamental frequency or 40 GHz, whichever is lower.




Report No.: 15031419HKG-003                                                                                  12
FCC ID: PQN44497RX2G4
                                         Intertek Testing Services Hong Kong Ltd.
                                     2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                           Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com


Issuing Laboratory:
Intertek Testing Services Hong Kong Limited
HKAS has accredited this laboratory (HOKLAS 005 – TEST) under HOKLAS for specific
laboratory activities as listed in the HOKLAS directory of accredited laboratories.




8.4       Emissions Test Procedures (cont’d)

          The EUT is warmed up for 15 minutes prior to the test.

          AC power to the unit is varied from 85% to 115% nominal and variation in the
          fundamental emission field strength is recorded. If battery powered, a new,
          fully charged battery is used.

          Conducted measurements were made as described in ANSI C63.4 (2009).

          The IF bandwidth used for measurement of radiated signal strength was 100 kHz
          or greater when frequency is below 1000 MHz. Where pulsed transmissions of
          short enough pulse duration warrant, a greater bandwidth is selected according
          to the recommendations of Hewlett Packard Application Note 150-2. A discussion
          of whether pulse desensitivity is applicable to this unit is included in this report
          (See Exhibit 8.1). Above 1000 MHz, a resolution bandwidth of 10 MHz is used.

          Transmitter measurements are normally conducted at a measurement distance
          of three meters. However, to assure low enough noise floor in the forbidden
          bands and above 1 GHz, signals are acquired at a distance of one meter or less. All
          measurements are extrapolated to three meters using inverse scaling, unless
          otherwise reported. Measurements taken at a closer distance are so marked.




Report No.: 15031419HKG-003                                                                                  13
FCC ID: PQN44497RX2G4
                                         Intertek Testing Services Hong Kong Ltd.
                                     2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                           Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com


Issuing Laboratory:
Intertek Testing Services Hong Kong Limited
HKAS has accredited this laboratory (HOKLAS 005 – TEST) under HOKLAS for specific
laboratory activities as listed in the HOKLAS directory of accredited laboratories.




8.4.1 Radiated Emission Test Setup

          The figure below shows the test setup, which is utilized to make these
          measurements.

                                                                                                        Antenna
                                                                                                        Tower
                                                                           1.0~4.0m


                                                           3m                                                Receiver
                                                                                                             Antenna

                                 EUT &
                               Peripherals


            0.8m



                     Ground Plane

                                                                                      □


                                                                                                      RF Test
                                                                                                      Receiver




Report No.: 15031419HKG-003                                                                                             14
FCC ID: PQN44497RX2G4
                                         Intertek Testing Services Hong Kong Ltd.
                                     2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                           Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com


Issuing Laboratory:
Intertek Testing Services Hong Kong Limited
HKAS has accredited this laboratory (HOKLAS 005 – TEST) under HOKLAS for specific
laboratory activities as listed in the HOKLAS directory of accredited laboratories.




9.0       Equipment List

1)     Radiated Emissions Test
 Equipment              EMI Test Receiver                             Biconical Antenna            Log Periodic Antenna
 Registration No.           EW-2500                                       EW-0571                       EW-0446
 Manufacturer                  R&S                                         EMCO                          EMCO
 Model No.                     ESCI                                        3104C                           3146
 Calibration Date         Nov. 06, 2014                                 Nov. 01, 2013                 Nov. 10, 2014
 Calibration Due Date     Nov. 06, 2015                                 May 01, 2015                  May 10, 2016

 Equipment                           Spectrum Analyzer                   Double Ridged
                                                                         Guide Antenna
 Registration No.                          EW-2466                         EW-1133
 Manufacturer                                R&S                            EMCO
 Model No.                                  FSP30                            3115
 Calibration Date                        Sep. 02, 2014                   Apr. 30, 2014
 Calibration Due Date                    Sep. 02, 2015                   Oct. 30, 2015

2)     Bandedge & Average factor Measurement
 Equipment            Spectrum Analyzer
 Registration No.          EW-2329
 Manufacturer                R&S
 Model No.                   FSP3
 Calibration Date        Jun. 19, 2014
 Calibration Due Date    Jun. 19, 2015




                                             END OF TEST REPORT




Report No.: 15031419HKG-003                                                                                           15
FCC ID: PQN44497RX2G4
                                         Intertek Testing Services Hong Kong Ltd.
                                     2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                           Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com



Document Created: 2015-06-02 15:55:48
Document Modified: 2015-06-02 15:55:48

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC