Test Report

FCC ID: PQN44452TX2G4

Test Report

Download: PDF
FCCID_2478488

 lntertek
Valued Quallty. Dellvered,

lssuing Laboratory:
lntertek Testing Services Hong Kong Limited
HKAS has accrôdited thls laboratory (HOKLAS 005 - TEST) undor HOKLAS for spec¡fic
lsboratory âc'tlvitlos as llsl.ed ln tho HOKLAS direclory ofaccrsdlted laboratoriss.




                                                                   TEST REPORT

                                               Report No.:                   I 41    0l I 67HKG-001

                                               Spin Master Toys Far East Ltd.


                                                             Application
                                                                  For
                                                             Certification
                                                           (Original Grant)
                                                     (FCC lD: PQN44452TX2G4|

                                                                       Transceiver




Prepared and Checked by:                                                                   Approved by:




                                                                                           Chan Chi Hung,
Lead Engineer
                                                                                           Date: December 17,2014


    lnlerlek'E slåndard Têm8 and Condilions     qn   be obtalned ât ourrebe¡lo   hltp/w   ¡ntertok.@rn/loml.
    ThiE rcport shall not be r€producsd, êxcopl in full,
    Thi¡ report ls for lhe sxclusive ues of lnlertok's Cllent and ls provldod pursuant to lho agro€ment b€tmsn lnterlek and its Cli€nl. lnlsrtek'8 responribilily end
    l¡sbil¡ty sr€ lim¡tod lo lho tems and @ndiüone of lhe agrc€m€nt, lnterlok aslumos no l¡¡bìllty to sny prrty, olher t¡an lo lho Cl¡onl in a@rdanæ with tÀo
    ågreemonl, tor eny loo3, oxp€nEo or damage oøeioned by ûìe urs of ûì¡s reporl. only tho cl¡onl lr aulhoriz€d lo pomlt @py¡ng or dl8tribution ol lh¡s report and
    then only ln ¡ls onlirely. Any ulo of lhe lnlodok nsm or ono ol ils marks for the ssle or advert¡ssment of lho leslod msterisl, producl or serylæ must l¡r8l bs
    spprcvod in wiùng by lnl€riok, The obsory€tion8 and lost rcrulls ¡n lhls rsport aro ßlevant only lo the sEmplo losl€d. Thls rcporl by   itrol   does not ¡mply thEt tho
    malerial, producl, or reryl@ i! or har evsr boen undsran lnleñok @rl¡fiætion progEm.




                                                   Intertek Testlng Services Hong Kong Ltd.
                                          zF., Garmênt Contrê, 576 Caslle Peak Road, Kowloon, Hong Kong.
                                Tol: (852) 2173 8888 Fax: (852) 2785 5487 Wsbslts: t¡wvw.hk.lntortok-etls€


Issuing Laboratory:
Intertek Testing Services Hong Kong Limited
HKAS has accredited this laboratory (HOKLAS 005 – TEST) under HOKLAS for specific
laboratory activities as listed in the HOKLAS directory of accredited laboratories.




                                             GENERAL INFORMATION


 Grantee:                                        Spin Master Toys Far East Ltd.
 Grantee Address:                                Room 1113, 11/F., Chinachem Golden Plaza,
                                                 77 Mody Road, Tsim Sha Tsui East,
                                                 Kowloon, Hong Kong.
 Contact Person:                                 Andy Wong
 Tel:                                            (86)0769-81080068
 Fax:                                            (86)0769-82207100
 e-mail:                                         andyw@spinmaster.com
 Manufacturer:                                   Spin Master Toys
 Manufacturer Address:                           Room 1113A, 11/F., Chinachem Golden Plaza,
                                                 77 Mody Road, Tsim Sha Tsui East,
                                                 Kowloon, Hong Kong.
 Brand Name:                                     N/A
 Model:                                          44452
 Additional Model:                               1031457, 1031458, 6019618, 6019657
 Type of EUT:                                    Transceiver
 Description of EUT:                             ARH RDC Sky Stunt Ast
 Serial Number:                                  N/A
 FCC ID:                                         PQN44452TX2G4
 Date of Sample Submitted:                       October 31, 2014
 Date of Test:                                   October 31, 2014 to November 21, 2014
 Report No.:                                     14101167HKG-001
 Report Date:                                    December 17, 2014
 Environmental Conditions:                       Temperature: +10 to 40°C
                                                 Humidity: 10 to 90%




Report No.: 14101167HKG-001                                                                                  i
FCC ID: PQN44452TX2G4
                                         Intertek Testing Services Hong Kong Ltd.
                                     2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                           Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com


Issuing Laboratory:
Intertek Testing Services Hong Kong Limited
HKAS has accredited this laboratory (HOKLAS 005 – TEST) under HOKLAS for specific
laboratory activities as listed in the HOKLAS directory of accredited laboratories.




                                         SUMMARY OF TEST RESULT



                           TEST SPECIFICATION                                              REFERENCE RESULTS
 Radiated Emission
                                                                                                 15.249      Pass
 Radiated Emission on the Bandedge
 Restricted bands of operation                                                                   15.205      Pass


The equipment under test is found to be complying with the following standards:
FCC Part 15, October 1, 2013 Edition




 Note: 1. The EUT uses a permanently attached antenna which, in accordance to section 15.203, is
          considered sufficient to comply with the pervisions of this section.
       2. Pursuant to FCC part 15 Section 15.215(c), the 20 dB bandwidth of the emission was contained
          within the frequency band designated (mentioned as above) which the EUT operated. The
          effects, if any, from frequency sweeping, frequency hopping, other modulation techniques and
          frequency stability over excepted variations in temperature and supply voltage were considered.



Report No.: 14101167HKG-001                                                                                         ii
FCC ID: PQN44452TX2G4
                                         Intertek Testing Services Hong Kong Ltd.
                                     2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                           Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com


Issuing Laboratory:
Intertek Testing Services Hong Kong Limited
HKAS has accredited this laboratory (HOKLAS 005 – TEST) under HOKLAS for specific
laboratory activities as listed in the HOKLAS directory of accredited laboratories.




                                                    Table of Contents

1.0   General Description .............................................................................................. 1
  1.1  Product Description ............................................................................................. 1
  1.2  Related Submittal(s) Grants................................................................................. 1
  1.3  Test Methodology ................................................................................................ 1
  1.4  Test Facility ......................................................................................................... 2

2.0   System Test Configuration................................................................................... 3
  2.1   Justification.......................................................................................................... 3
  2.2   EUT Exercising Software..................................................................................... 3
  2.3   Special Accessories ............................................................................................ 3
  2.4   Measurement Uncertainty.................................................................................... 3
  2.5   Support Equipment List and Description.............................................................. 3

3.0   Emission Results .................................................................................................. 4
  3.1  Field Strength Calculation.................................................................................... 4
  3.2  Radiated Emission Configuration Photograph ..................................................... 5
  3.3  Radiated Emission Data ...................................................................................... 5

4.0       Equipment Photographs....................................................................................... 9

5.0       Product Labelling.................................................................................................. 9

6.0       Technical Specifications ...................................................................................... 9

7.0       Instruction Manual ................................................................................................ 9

8.0   Miscellaneous Information ................................................................................. 10
  8.1   Radiated Emission on the Bandedge................................................................. 10
  8.2   Discussion of Pulse Desensitization .................................................................. 13
  8.3   Calculation of Average Factor............................................................................ 13
  8.4   Emissions Test Procedures ............................................................................... 15

9.0       Equipment List .................................................................................................... 17




Report No.: 14101167HKG-001                                                                                              iii
FCC ID: PQN44452TX2G4
                                         Intertek Testing Services Hong Kong Ltd.
                                     2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                           Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com


Issuing Laboratory:
Intertek Testing Services Hong Kong Limited
HKAS has accredited this laboratory (HOKLAS 005 – TEST) under HOKLAS for specific
laboratory activities as listed in the HOKLAS directory of accredited laboratories.




1.0       General Description

1.1       Product Description

          The Equipment Under Test (EUT) is a 2.4GHz transceiver (i.e. Controller) for a
          RC Plane. The EUT is powered by DC12.0V (8X1.5V AA batteries). The
          operating frequency is 2408MHz, 2424MHz, 2442MHz and 2460MHz. After
          pairing with plane, the plane can be controlled to fly forward, upward/downward,
          turn left/right directions and any motions. Also, the EUT has a charging circuitry,
          the corresponding plane can be charged by the EUT.

          The Model: 1031457, 1031458, 6019618 and 6019657 are the same as the
          Model: 44452 in hardware aspect. The difference in model number serves
          as marketing strategy. The models are different in model number only.

          Antenna Type: Internal, Integral

          For electronic filing, the brief circuit description is saved with filename: descri.pdf.


1.2       Related Submittal(s) Grants

          This is a single application for certification of a transmitter.

          The Certification procedure of transceiver (Plane) for this transmitter (with FCC
          ID: PQN44452RX2G4) is being processed as the same time of this application.


1.3       Test Methodology

          Radiated emission measurements was performed according to the procedures
          in ANSI C63.4 (2009). All radiated measurements were performed in an Open
          Area Test Site. Preliminary scans were performed in the Open Area Test Site
          only to determine worst case modes. All radiated tests were performed at an
          antenna to EUT distance of 3 meters, unless stated otherwise in the
          “Justification Section” of this Application.




Report No.: 14101167HKG-001                                                                                  1
FCC ID: PQN44452TX2G4
                                         Intertek Testing Services Hong Kong Ltd.
                                     2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                           Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com


Issuing Laboratory:
Intertek Testing Services Hong Kong Limited
HKAS has accredited this laboratory (HOKLAS 005 – TEST) under HOKLAS for specific
laboratory activities as listed in the HOKLAS directory of accredited laboratories.




1.4       Test Facility

          The open area test site facility used to collect the radiated data is located at
          Workshop No. 3, G/F., World-Wide Industrial Centre, 43-47 Shan Mei Street, Fo
          Tan, Sha Tin, N.T., Hong Kong. This test facility and site measurement data
          have been placed on file with the FCC.




Report No.: 14101167HKG-001                                                                                  2
FCC ID: PQN44452TX2G4
                                         Intertek Testing Services Hong Kong Ltd.
                                     2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                           Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com


Issuing Laboratory:
Intertek Testing Services Hong Kong Limited
HKAS has accredited this laboratory (HOKLAS 005 – TEST) under HOKLAS for specific
laboratory activities as listed in the HOKLAS directory of accredited laboratories.




2.0       System Test Configuration

2.1       Justification

          The system was configured for testing in a typical fashion (as a customer would
          normally use it), and in the confines as outlined in ANSI C63.4 (2009).

          The device was powered by new 8 X 1.5V AA batteries.

          For maximizing emissions, the EUT was rotated through 360°, the antenna
          height was varied from 1 meter to 4 meters above the ground plane, and the
          antenna polarization was changed. This step by step procedure for maximizing
          emissions led to the data reported in Exhibit 3.0.

          The unit was operated standalone and placed in the center of the turntable.

          The equipment under test (EUT) was configured for testing in a typical fashion
          (as a customer would normally use it). The EUT was mounted to a plastic stand
          if necessary and placed on the wooden turntable, which enabled the engineer to
          maximize emissions through its placement in the three orthogonal axes.


2.2       EUT Exercising Software

          There was no special software to exercise the device.                                          Once the unit is
          powered up, it transmits the RF signal continuously.


2.3       Special Accessories

          There are no special accessories necessary for compliance of this product.


2.4       Measurement Uncertainty

          When determining of the test conclusion, the Measurement Uncertainty of test
          has been considered.


2.5       Support Equipment List and Description

          N/A.




Report No.: 14101167HKG-001                                                                                            3
FCC ID: PQN44452TX2G4
                                         Intertek Testing Services Hong Kong Ltd.
                                     2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                           Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com


Issuing Laboratory:
Intertek Testing Services Hong Kong Limited
HKAS has accredited this laboratory (HOKLAS 005 – TEST) under HOKLAS for specific
laboratory activities as listed in the HOKLAS directory of accredited laboratories.




3.0       Emission Results

          Data is included of the worst case configuration (the configuration which resulted
          in the highest emission levels). A sample calculation, configuration photographs
          and data tables of the emissions are included.


3.1       Field Strength Calculation

          The field strength is calculated by adding the Antenna Factor and Cable Factor,
          and subtracting the Amplifier Gain (if any), Average Factor (optional) from the
          measured reading. The basic equation with a sample calculation is as follows:
          FS = RA + AF + CF - AG - AV
          where          FS = Field Strength in dBµV/m
                         RA = Receiver Amplitude (including preamplifier) in dBµV
                         CF = Cable Attenuation Factor in dB
                         AF = Antenna Factor in dB
                         AG = Amplifier Gain in dB
                         AV = Average Factor in dB

          In the following table(s), the reading shown on the data table reflects the preamplifier
          gain. An example for the calculations in the following table is as follows:
          FS = RR + LF
          where           FS = Field Strength in dBµV/m
                          RR = RA - AG - AV in dBµV
                          LF = CF + AF in dB

          Assume a receiver reading of 52.0 dBµV is obtained. The antenna factor of
          7.4 dB and cable factor of 1.6 dB are added. The amplifier gain of 29 dB and
          average factor of 5 dB are subtracted, giving a field strength of 27 dBµV/m.
          This value in dBµV/m was converted to its corresponding level in µV/m.

          RA = 52.0 dBµV/m
          AF = 7.4 dB                                            RR = 18.0 dBµV
          CF = 1.6 dB                                            LF = 9.0 dB
          AG = 29.0 dB
          AV = 5.0 dB
          FS = RR + LF
          FS = 18 + 9 = 27 dBµV/m

          Level in µV/m = Common Antilogarithm [(27 dBµV/m)/20] = 22.4 µV/m




Report No.: 14101167HKG-001                                                                                  4
FCC ID: PQN44452TX2G4
                                         Intertek Testing Services Hong Kong Ltd.
                                     2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                           Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com


Issuing Laboratory:
Intertek Testing Services Hong Kong Limited
HKAS has accredited this laboratory (HOKLAS 005 – TEST) under HOKLAS for specific
laboratory activities as listed in the HOKLAS directory of accredited laboratories.




3.2       Radiated Emission Configuration Photograph

          The worst case in radiated emission was found at 2400 MHz

          For electronic filing, the worst case radiated emission configuration photographs
          are saved with filename: radiated photos.pdf.


3.3       Radiated Emission Data

          The data on the following page lists the significant emission frequencies, the
          limit and the margin of compliance. Numbers with a minus sign are below the
          limit.

          Judgment: Passed by 11.8 dB




Report No.: 14101167HKG-001                                                                                  5
FCC ID: PQN44452TX2G4
                                         Intertek Testing Services Hong Kong Ltd.
                                     2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                           Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com


Issuing Laboratory:
Intertek Testing Services Hong Kong Limited
HKAS has accredited this laboratory (HOKLAS 005 – TEST) under HOKLAS for specific
laboratory activities as listed in the HOKLAS directory of accredited laboratories.




Applicant: Spin Master Toys Far East Ltd.                                              Date of Test: November 21, 2014
Model: 44452
Worst-Case Operating Mode: Transmitting

                                              Table 1
                                       Radiated Emissions
                        Pursuant to FCC Part 15 Section 15.249 Requirement

Lowest Channel
                                       Pre-Amp Antenna   Net at  Average                     Calculated   Average Limit
 Polari- Frequency         Reading       Gain   Factor 3m - Peak Factor                        at 3m          at 3m       Margin
 zation     (MHz)          (dBμV)        (dB)    (dB)  (dBμV/m)    (dB)                      (dBμV/m)       (dBμV/m)        (dB)
   H      2408.000          98.6          33     29.4    95.0      26.4                        68.6            94.0        -25.4
   H     4816.000           50.5          33     34.9    52.4     26.4                         26.0           54.0        -28.0
   H      7224.000          48.4          33     37.9    53.3      26.4                        26.9            54.0        -27.1
   H      9632.000          48.1          33     40.4    55.5      26.4                        29.1            54.0        -24.9
   H     12040.000          49.2          33     40.5    56.7     26.4                         30.3           54.0        -23.7
   H     14448.000          53.8          33     40.0    60.8      26.4                        34.4            54.0       -19.6

                                                 Pre-Amp          Antenna               Net at       Peak Limit
  Polari-     Frequency          Reading           Gain            Factor             3m - Peak        at 3m          Margin
  zation         (MHz)           (dBμV)            (dB)             (dB)              (dBμV/m)       (dBμV/m)           (dB)
    H          2408.000           98.6              33              29.4                95.0           114.0           -19.0
    H         4816.000            50.5              33              34.9                52.4           74.0           -21.6
    H          7224.000           48.4              33              37.9                53.3           74.0            -20.7
    H          9632.000           48.1              33              40.4                55.5           74.0            -18.5
    H         12040.000           49.2              33              40.5                56.7           74.0           -17.3
    H         14448.000           53.8              33              40.0                60.8           74.0            -13.2


NOTES: 1. Peak Detector Data unless otherwise stated.

               2. All measurements were made at 3 meters. Harmonic emissions not
                  detected at the 3-meter distances were measured at 0.3-meter and an
                  inverse proportional extrapolation was performed to compare the signal
                  level to the 3-meter limit. No other harmonic emissions than those
                  reported were detected at a test distance of 0.3-meter.

               3. Negative sign in the column shows value below limit.

               4. Horn antenna is used for the emission over 1000MHz.

               5. Emission (the row indicated by bold italic) within the restricted band meets
                  the requirement of FCC Part 15 Section 15.205 / RSS-210 Section 2.2.

               6. 10MHz of RBW is used for radiated emission measurement.

Report No.: 14101167HKG-001                                                                                                    6
FCC ID: PQN44452TX2G4
                                         Intertek Testing Services Hong Kong Ltd.
                                     2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                           Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com


Issuing Laboratory:
Intertek Testing Services Hong Kong Limited
HKAS has accredited this laboratory (HOKLAS 005 – TEST) under HOKLAS for specific
laboratory activities as listed in the HOKLAS directory of accredited laboratories.




Applicant: Spin Master Toys Far East Ltd.                                              Date of Test: November 21, 2014
Model: 44452
Worst-Case Operating Mode: Transmitting

                                              Table 2
                                       Radiated Emissions
                        Pursuant to FCC Part 15 Section 15.249 Requirement

Middle Channel
                                       Pre-Amp Antenna   Net at  Average                     Calculated   Average Limit
 Polari- Frequency         Reading       Gain   Factor 3m - Peak Factor                        at 3m          at 3m       Margin
 zation     (MHz)          (dBμV)        (dB)    (dB)  (dBμV/m)    (dB)                      (dBμV/m)       (dBμV/m)        (dB)
   H      2442.000          94.0          33     29.4    90.4      26.4                        64.0            94.0        -30.0
   H     4884.000           54.1          33     34.9    56.0     26.4                         29.6           54.0        -24.4
   H     7326.000           48.6          33     37.9    53.5     26.4                         27.1           54.0        -26.9
   H      9768.000          48.0          33     40.4    55.4      26.4                        29.0            54.0        -25.0
   H     12210.000          49.1          33     40.5    56.6     26.4                         30.2           54.0        -23.8
   H     14652.000          54.9          33     38.4    60.3      26.4                        33.9            54.0       -20.1

                                                 Pre-Amp          Antenna               Net at       Peak Limit
  Polari-     Frequency          Reading           Gain            Factor             3m - Peak        at 3m          Margin
  zation         (MHz)           (dBμV)            (dB)             (dB)              (dBμV/m)       (dBμV/m)           (dB)
    H          2442.000           94.0              33              29.4                90.4           114.0           -23.6
    H         4884.000            54.1              33              34.9                56.0           74.0           -18.0
    H         7326.000            48.6              33              37.9                53.5           74.0           -20.5
    H          9768.000           48.0              33              40.4                55.4           74.0            -18.6
    H         12210.000           49.1              33              40.5                56.6           74.0           -17.4
    H         14652.000           54.9              33              38.4                60.3           74.0            -13.7


NOTES: 1. Peak Detector Data unless otherwise stated.

               2. All measurements were made at 3 meters. Harmonic emissions not
                  detected at the 3-meter distances were measured at 0.3-meter and an
                  inverse proportional extrapolation was performed to compare the signal
                  level to the 3-meter limit. No other harmonic emissions than those
                  reported were detected at a test distance of 0.3-meter.

               3. Negative sign in the column shows value below limit.

               4. Horn antenna is used for the emission over 1000MHz.

               5. Emission (the row indicated by bold italic) within the restricted band meets
                  the requirement of FCC Part 15 Section 15.205 / RSS-210 Section 2.2.

               6. 10MHz of RBW is used for radiated emission measurement.

Report No.: 14101167HKG-001                                                                                                    7
FCC ID: PQN44452TX2G4
                                         Intertek Testing Services Hong Kong Ltd.
                                     2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                           Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com


Issuing Laboratory:
Intertek Testing Services Hong Kong Limited
HKAS has accredited this laboratory (HOKLAS 005 – TEST) under HOKLAS for specific
laboratory activities as listed in the HOKLAS directory of accredited laboratories.




Applicant: Spin Master Toys Far East Ltd.                                              Date of Test: November 21, 2014
Model: 44452
Worst-Case Operating Mode: Transmitting

                                              Table 3
                                       Radiated Emissions
                        Pursuant to FCC Part 15 Section 15.249 Requirement

Highest Channel
                                       Pre-Amp Antenna   Net at  Average                     Calculated   Average Limit
 Polari- Frequency         Reading       Gain   Factor 3m - Peak Factor                        at 3m          at 3m       Margin
 zation     (MHz)          (dBμV)        (dB)    (dB)  (dBμV/m)    (dB)                      (dBμV/m)       (dBμV/m)        (dB)
   H      2460.000          95.3          33     29.4    91.7      26.4                        65.3            94.0        -28.7
   H     4920.000           56.5          33     34.9    58.4     26.4                         32.0           54.0        -22.0
   H     7380.000           48.5          33     37.9    53.4     26.4                         27.0           54.0        -27.0
   H      9840.000          48.5          33     40.4    55.9      26.4                        29.5            54.0        -24.5
   H     12300.000          48.8          33     40.5    56.3     26.4                         29.9           54.0        -24.1
   H     14760.000          55.2          33     38.4    60.6      26.4                        34.2            54.0       -19.8

                                                 Pre-Amp          Antenna               Net at       Peak Limit
  Polari-     Frequency          Reading           Gain            Factor             3m - Peak        at 3m          Margin
  zation         (MHz)           (dBμV)            (dB)             (dB)              (dBμV/m)       (dBμV/m)           (dB)
    H          2460.000           95.3              33              29.4                91.7           114.0           -22.3
    H         4920.000            56.5              33              34.9                58.4           74.0           -15.6
    H         7380.000            48.5              33              37.9                53.4           74.0           -20.6
    H          9840.000           48.5              33              40.4                55.9           74.0            -18.1
    H         12300.000           48.8              33              40.5                56.3           74.0           -17.7
    H         14760.000           55.2              33              38.4                60.6           74.0            -13.4


NOTES: 1. Peak Detector Data unless otherwise stated.

               2. All measurements were made at 3 meters. Harmonic emissions not
                  detected at the 3-meter distances were measured at 0.3-meter and an
                  inverse proportional extrapolation was performed to compare the signal
                  level to the 3-meter limit. No other harmonic emissions than those
                  reported were detected at a test distance of 0.3-meter.

               3. Negative sign in the column shows value below limit.

               4. Horn antenna is used for the emission over 1000MHz.

               5. Emission (the row indicated by bold italic) within the restricted band meets
                  the requirement of FCC Part 15 Section 15.205 / RSS-210 Section 2.2.

               6. 10MHz of RBW is used for radiated emission measurement.

Report No.: 14101167HKG-001                                                                                                    8
FCC ID: PQN44452TX2G4
                                         Intertek Testing Services Hong Kong Ltd.
                                     2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                           Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com


Issuing Laboratory:
Intertek Testing Services Hong Kong Limited
HKAS has accredited this laboratory (HOKLAS 005 – TEST) under HOKLAS for specific
laboratory activities as listed in the HOKLAS directory of accredited laboratories.




4.0       Equipment Photographs

          For electronic filing, the photographs are saved with filename: external photos.pdf
          and internal photos.pdf.


5.0       Product Labelling

          For electronics filing, the FCC ID label artwork and the label location are saved
          with filename: label.pdf.


6.0       Technical Specifications

          For electronic filing, the block diagram and schematic of the tested EUT are
          saved with filename: block.pdf and circuit.pdf respectively.


7.0       Instruction Manual

          For electronic filing, a preliminary copy of the Instruction Manual is saved with
          filename: manual.pdf.

          This manual will be provided to the end-user with each unit sold/leased in the
          United States.




Report No.: 14101167HKG-001                                                                                  9
FCC ID: PQN44452TX2G4
                                         Intertek Testing Services Hong Kong Ltd.
                                     2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                           Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com


Issuing Laboratory:
Intertek Testing Services Hong Kong Limited
HKAS has accredited this laboratory (HOKLAS 005 – TEST) under HOKLAS for specific
laboratory activities as listed in the HOKLAS directory of accredited laboratories.




8.0       Miscellaneous Information

          The miscellaneous information includes details of the test procedure and
          measured bandwidth / calculation of factor such as pulse desensitization and
          averaging factor (calculation and timing diagram).


8.1       Radiated Emission on the Bandedge

          From the following plots, they show that the fundamental emissions are confined
          in the specified band (2400MHz to 2483.5MHz). In case of the fundamental
          emissions are within two standard bandwidths from the bandedge, the delta
          measurement technique is used for determining bandedge compliance.
          Standard bandwidth is the bandwidth specified by ANSI C63.4 (2009) for
          frequency being measured.

          Emissions radiated outside of the specified frequency bands, except harmonics,
          are attenuated by 50dB below the level of the fundamental or to the general
          radiated emissions limits in Section 15.209, whichever is the lesser attenuation,
          which meet the requirement of part 15.249(d).




Report No.: 14101167HKG-001                                                                                  10
FCC ID: PQN44452TX2G4
                                         Intertek Testing Services Hong Kong Ltd.
                                     2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                           Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com


Issuing Laboratory:
Intertek Testing Services Hong Kong Limited
HKAS has accredited this laboratory (HOKLAS 005 – TEST) under HOKLAS for specific
laboratory activities as listed in the HOKLAS directory of accredited laboratories.




Report No.: 14101167HKG-001                                                                                  11
FCC ID: PQN44452TX2G4
                                         Intertek Testing Services Hong Kong Ltd.
                                     2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                           Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com


Issuing Laboratory:
Intertek Testing Services Hong Kong Limited
HKAS has accredited this laboratory (HOKLAS 005 – TEST) under HOKLAS for specific
laboratory activities as listed in the HOKLAS directory of accredited laboratories.




          Peak Measurement

          Bandedge compliance is determined by applying marker-delta method, i.e.
          (Bandedge Plot).

          Lower bandedge

          Peak Resultant field strength = Fundamental emissions (peak value) – delta
          from the plot

          =95.0 dBµV/m – 32.8 dB
          =62.2 dBµV/m

          Average Resultant field strength = Fundamental emissions (average value) –
          delta from the plot

          =68.6 dBµV/m – 32.8 dB
          =35.8 dBµV/m

          Upper bandedge

          Peak Resultant field strength = Fundamental emissions (peak value) – delta
          from the plot

          =91.7 dBµV/m – 37.8 dB
          =53.9 dBµV/m

          Average Resultant field strength = Fundamental emissions (average value) –
          delta from the plot

          =65.3 dBµV/m – 37.8 dB
          =27.5 dBµV/m

          The resultant field strength meets the general radiated emission limit in
          Section 15.209, which does not exceed 74 dBµV/m (Peak Limit) and 54 dBµV/m
          (Average Limit).




Report No.: 14101167HKG-001                                                                                  12
FCC ID: PQN44452TX2G4
                                         Intertek Testing Services Hong Kong Ltd.
                                     2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                           Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com


Issuing Laboratory:
Intertek Testing Services Hong Kong Limited
HKAS has accredited this laboratory (HOKLAS 005 – TEST) under HOKLAS for specific
laboratory activities as listed in the HOKLAS directory of accredited laboratories.




8.2       Discussion of Pulse Desensitization

          Pulse desensitivity is not applicable for this device. The effective period (Teff)
          is approximately 0.28ms for a digital “1” bit which illustrated on technical
          specification, with a resolution bandwidth (3dB) of 1MHz, so the pulse
          desensitivity factor is 0dB.


8.3       Calculation of Average Factor

          The duty cycle is simply the on-time divided by the period:

          The duration of one cycle = 100 ms

          Effective period of the cycle = 17*0.28 = 4.76ms

          DC = 4.76/100 = 0.0476

          Therefore, the averaging factor is found by 20log 0.0476 = -26.4dB.




Report No.: 14101167HKG-001                                                                                  13
FCC ID: PQN44452TX2G4
                                         Intertek Testing Services Hong Kong Ltd.
                                     2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                           Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com


Issuing Laboratory:
Intertek Testing Services Hong Kong Limited
HKAS has accredited this laboratory (HOKLAS 005 – TEST) under HOKLAS for specific
laboratory activities as listed in the HOKLAS directory of accredited laboratories.




                                                          RBW 1 MHz    Delta 1 [T1 ]
                                                          VBW 3 MHz                0.60 dB
        Ref           15 dBm          * Att   30 dB       SWT 5 ms           280.000000 µs

                                                                       Marker 1 [T1 ]
            10                                                                   -21.32 dBm
                                                                               0.000000 s        B
                                                                                                SGL
1 AP        0
CLRWR                                                                                           TRG

            -10


        1         1
            -20



            -30

                        TRG -36 dBm
            -40



            -50



            -60



            -70



            -80


        Center 2.408 GHz                              500 µs/




Report No.: 14101167HKG-001                                                                                         14
FCC ID: PQN44452TX2G4
                                                Intertek Testing Services Hong Kong Ltd.
                                            2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                                  Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com


Issuing Laboratory:
Intertek Testing Services Hong Kong Limited
HKAS has accredited this laboratory (HOKLAS 005 – TEST) under HOKLAS for specific
laboratory activities as listed in the HOKLAS directory of accredited laboratories.




8.4       Emissions Test Procedures

          The following is a description of the test procedure used by Intertek Testing
          Services Hong Kong Ltd. in the measurements of transmitter operating under
          the Part 15, Subpart C rules.

          The transmitting equipment under test (EUT) is placed on a wooden turntable
          which is four feet in diameter and approximately one meter in height above the
          ground plane. During the radiated emissions test, the turntable is rotated and
          any cables leaving the EUT are manipulated to find the configuration resulting in
          maximum emissions. The EUT is adjusted through all three orthogonal axis to
          obtain maximum emission levels. The antenna height and polarization are also
          varied during the testing to search for maximum signal levels. The height of the
          antenna is varied from one to four meters.

          Detector function for radiated emissions is in peak mode. Average readings, when
          required, are taken by measuring the duty cycle of the equipment under test and
          subtracting the corresponding amount in dB from the measured peak readings. A
          detailed description for the calculation of the average factor can be found in Exhibit 8.3.

          The frequency range scanned is from the lowest radio frequency signal
          generated in the device which is greater than 9 kHz to the tenth harmonic of the
          highest fundamental frequency or 40 GHz, whichever is lower.




Report No.: 14101167HKG-001                                                                                  15
FCC ID: PQN44452TX2G4
                                         Intertek Testing Services Hong Kong Ltd.
                                     2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                           Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com


Issuing Laboratory:
Intertek Testing Services Hong Kong Limited
HKAS has accredited this laboratory (HOKLAS 005 – TEST) under HOKLAS for specific
laboratory activities as listed in the HOKLAS directory of accredited laboratories.




8.4       Emissions Test Procedures (cont’d)

          The EUT is warmed up for 15 minutes prior to the test.

          AC power to the unit is varied from 85% to 115% nominal and variation in the
          fundamental emission field strength is recorded. If battery powered, a new,
          fully charged battery is used.

          Conducted measurements were made as described in ANSI C63.4 (2009).

          The IF bandwidth used for measurement of radiated signal strength was 100 kHz
          or greater when frequency is below 1000 MHz. Where pulsed transmissions of
          short enough pulse duration warrant, a greater bandwidth is selected according
          to the recommendations of Hewlett Packard Application Note 150-2. A discussion
          of whether pulse desensitivity is applicable to this unit is included in this report
          (See Exhibit 8.1). Above 1000 MHz, a resolution bandwidth of 10 MHz is used.

          Transmitter measurements are normally conducted at a measurement distance
          of three meters. However, to assure low enough noise floor in the forbidden
          bands and above 1 GHz, signals are acquired at a distance of one meter or less. All
          measurements are extrapolated to three meters using inverse scaling, unless
          otherwise reported. Measurements taken at a closer distance are so marked.




Report No.: 14101167HKG-001                                                                                  16
FCC ID: PQN44452TX2G4
                                         Intertek Testing Services Hong Kong Ltd.
                                     2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                           Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com


Issuing Laboratory:
Intertek Testing Services Hong Kong Limited
HKAS has accredited this laboratory (HOKLAS 005 – TEST) under HOKLAS for specific
laboratory activities as listed in the HOKLAS directory of accredited laboratories.




9.0       Equipment List

1)     Radiated Emissions Test
 Equipment              EMI Test Receiver                                Spectrum Analyzer
 Registration No.            EW-2666                                         EW-2253
 Manufacturer                   R&S                                             R&S
 Model No.                     ESCI7                                          FSP40
 Calibration Date          Jun. 20, 2013                                   May 08, 2014
 Calibration Due Date      Dec. 20, 2014                                   May 08, 2015

 Equipment                           Double Ridged Guide BiConiLog Antenna -
                                           Antenna       26MHz to 6000MHz
 Registration No.                        EW-1133              EW-3061
 Manufacturer                              EMCO                EMCO
 Model No.                                  3115                3412E
 Calibration Date                      Apr. 30, 2014        Jul. 17, 2014
 Calibration Due Date                  Oct. 30, 2015        Jul. 17, 2015


2)     Bandedge and Average factor Measurement
 Equipment             Spectrum Analyzer
 Registration No.          EW-2329
 Manufacturer                 R&S
 Model No.                    FSP3
 Calibration Date        Jun. 19, 2014
 Calibration Due Date    Jun. 19, 2015




                                             END OF TEST REPORT




Report No.: 14101167HKG-001                                                                                  17
FCC ID: PQN44452TX2G4
                                         Intertek Testing Services Hong Kong Ltd.
                                     2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                           Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com



Document Created: 2014-12-18 16:39:00
Document Modified: 2014-12-18 16:39:00

© 2024 FCC.report