RF Exposure Info (MPE).pdf

FCC ID: PPQRYORR2L

RF Exposure Info

Download: PDF
FCCID_4436029

                                                           RF Exposure Report

                       Report No.: SA190606C24

                             FCC ID: PPQRYORR2L

                       Test Model: RYORR2L

                 Received Date: Jun. 06, 2019

                         Test Date: Jun. 19 ~ Jun. 25, 2019

                     Issued Date: Jul. 04, 2019


                         Applicant: LITE-ON Technology Corporation

                          Address: Bldg. C, 90, Chien 1 Rd., Chung-Ho, New Taipei City, 23585, Taiwan,
                                   R.O.C.



                        Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch

                    Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan,
                                 R.O.C.
                  Test Location: No. 19, Hwa Ya 2nd Rd., Wen Hwa Vil., Kwei Shan Dist., Taoyuan City
                                 33383, TAIWAN (R.O.C.)




This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted
only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this
report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product
unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you
provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided,
however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific
mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification.
The report must not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies.
Report No.: SA190606C24                                              Page No. 1 / 6                                             Report Format Version: 6.1.1


                                                                  Table of Contents
Release Control Record .................................................................................................................................. 3
1        Certificate of Conformity...................................................................................................................... 4
2        Evaluation Result .................................................................................................................................. 5
3        SAR Test Exclusion Thresholds.......................................................................................................... 6
4        Conclusion ............................................................................................................................................ 6




Report No.: SA190606C24                                             Page No. 2 / 6                                             Report Format Version: 6.1.1


                                             Release Control Record


Issue No.                 Description                                        Date Issued
SA190606C24               Original release                                   Jul. 04, 2019




Report No.: SA190606C24                         Page No. 3 / 6        Report Format Version: 6.1.1


1    Certificate of Conformity


            Product: RYORR2L

              Brand: Liteon

        Test Model: RYORR2L

    Sample Status: Engineering sample

          Applicant: LITE-ON Technology Corporation

          Test Date: Jun. 19 ~ Jun. 25, 2019

         Standards: FCC Part 2 (Section 2.1091)
                          KDB 447498 D03 (January 17, 2014)
                          IEEE C95.1-1992



The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd.,
Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data
evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts
of the measurements of the sample’s RF characteristics under the conditions specified in this report.




      Prepared by :                                              , Date:         Jul. 04, 2019
                             Pettie Chen / Senior Specialist




     Approved by :                                               , Date:         Jul. 04, 2019
                             Bruce Chen / Project Engineer




Report No.: SA190606C24                         Page No. 4 / 6                        Report Format Version: 6.1.1


2       Evaluation Result
Following FCC KDB 447498 D01 “General SAR test exclusion guidance”

The corresponding SAR Exclusion Threshold condition, listed below:

1) The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50
    mm are determined by:
    [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] ·[√f(GHz)]
    ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where
     f(GHz) is the RF channel transmit frequency in GHz.
         Power and distance are rounded to the nearest mW and mm before calculation.
         The result is rounded to one decimal place for comparison The test exclusions are applicable only
          when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100
          MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm is applied
          to determine SAR test exclusion.

2) At 100 MHz to 6 GHz and for test separation distances > 50 mm, the SAR test exclusion threshold is
    determined according to the following:
    a) [Threshold at 50 mm in step 1) + (test separation distance - 50mm)·( f(MHz)/150)] mW, at 100MHz to
        1500 MHz
    b) [Threshold at 50 mm in step 1) + (test separation distance - 50 mm)·10] mW at > 1500 MHz and ≤ 6
         GHz

3) At frequencies below 100 MHz, the following may be considered for SAR test exclusion.
    a) The threshold at the corresponding test separation distance at 100 MHz in step 2) is multiplied by [1 +
        log(100/f(MHz))] for test separation distances > 50 mm and < 200 mm.
    b) The threshold determined by the equation in a) for 50 mm and 100 MHz is multiplied by ½ for test
         separation distances ≤ 50 mm.
    c) SAR measurement procedures are not established below 100 MHz. When SAR test exclusion cannot
         be applied, a KDB inquiry is required to determine SAR evaluation requirements for any test results to
         be acceptable.




Report No.: SA190606C24                          Page No. 5 / 6                         Report Format Version: 6.1.1


3    SAR Test Exclusion Thresholds


Maximum measured transmitter power:
                                        Min. test                 SAR test     1-g extremity
    Frequency         Max. Power       separation                 exclusion      SAR test
                                                                                                      Result
      (MHz)             (mW)            distance                 calculation     exclusion
                                          (mm)                   value(NOTE)    thresholds
      13.56           0.00127974            5                0.00127974          442.974               Pass
Note: Calculate SAR test exclusion thresholds from condition “3” formulas.


4    Conclusion
Since Source-base time average power is below SAR test exclusion power thresholds, the SAR evaluation is
not required.



---END---




Report No.: SA190606C24                         Page No. 6 / 6                           Report Format Version: 6.1.1



Document Created: 2019-09-09 19:21:53
Document Modified: 2019-09-09 19:21:53

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC