RF Exposures report_rev 2.pdf

FCC ID: PPQIC3S

RF Exposure Info

Download: PDF
FCCID_4325735

                                                           RF Exposure Report

                       Report No.: SA190417D14

                             FCC ID: PPQIC3S

                       Test Model: IC3-32A-H-A

                   Series Model: IC3-32A-N-A, SC3-32A-H, SC3-32A-N, IC3-32A-H-V, IC3-32A-N-V

                 Received Date: Apr. 17, 2019

                         Test Date: Apr. 26 to May 3, 2019

                     Issued Date: May 7, 2019


                         Applicant: Lite-On Technology Corporation

                          Address: 90,Chien I Road, Chung Ho, Taipei Hsien, Taiwan, R.O.C



                        Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch

             Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan
                          (R.O.C.)
       FCC Registration /
      Designation Number:
                          198487 / TW2021




This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted
only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this
report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product
unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you
provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided,
however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific
mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification. The report
must not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies.
Report No.: SA190417D14                                              Page No. 1 / 7                                             Report Format Version: 6.1.1


                                                                   Table of Contents
Release Control Record .................................................................................................................................. 3
1         Certificate of Conformity...................................................................................................................... 4
2         RF Exposure .......................................................................................................................................... 5
    2.1      Limits For Maximum Permissible Exposure (MPE)............................................................................. 5
    2.2      MPE Calculation Formula ................................................................................................................... 5
    2.3      Classification ....................................................................................................................................... 5
    2.4      Calculation Result Of Maximum Conducted Power ............................................................................ 6




Report No.: SA190417D14                                              Page No. 2 / 7                                              Report Format Version: 6.1.1


                                          Release Control Record


Issue No.             Description                                         Date Issued
SA190417D14           Original release.                                   May 7, 2019




Report No.: SA190417D14                      Page No. 3 / 7        Report Format Version: 6.1.1


1    Certificate of Conformity


            Product: Charging Station

              Brand: LITEON

        Test Model: IC3-32A-H-A

      Series Model: IC3-32A-N-A, SC3-32A-H, SC3-32A-N, IC3-32A-H-V, IC3-32A-N-V

    Sample Status: Engineering sample

          Applicant: Lite-On Technology Corporation

          Test Date: Apr. 26 to May 3, 2019

         Standards: FCC Part 2 (Section 2.1091)

                          KDB 447498 D01 General RF Exposure Guidance v06
                          IEEE C95.1-1992



The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd.,
Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data
evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts
of the measurements of the sample’s RF characteristics under the conditions specified in this report.




     Prepared by :                                                     , Date:           May 7, 2019
                               Jessica Cheng / Senior Specialist




     Approved by :                                                     , Date:           May 7, 2019
                            Rex Lai / Associate Technical Manager




Report No.: SA190417D14                         Page No. 4 / 7                        Report Format Version: 6.1.1


2      RF Exposure

2.1      Limits For Maximum Permissible Exposure (MPE)

    Frequency Range          Electric Field     Magnetic Field       Power Density        Average Time
         (MHz)              Strength (V/m)      Strength (A/m)         (mW/cm2)             (minutes)
                             Limits For General Population / Uncontrolled Exposure
        0.3-1.34                 614                    1.63             (100)*                 30
                                                                                2
         1.34-30                824/f                   2.19/f          (180/f )*               30
         30-300                  27.5                   0.073             0.2                   30
        300-1500                  …                      …               f/1500                 30
      1500-100,000                …                      …                1.0                   30

f = Frequency in MHz ; *Plane-wave equivalent power density


2.2      MPE Calculation Formula

Pd = (Pout*G) / (4*pi*r2)
where
Pd = power density in mW/cm2
Pout = output power to antenna in mW
G = gain of antenna in linear scale
Pi = 3.1416
R = distance between observation point and center of the radiator in cm



2.3      Classification

      The antenna of this product, under normal use condition, is at least 20cm away from the body of the user.
      So, this device is classified as Mobile Device.




Report No.: SA190417D14                          Page No. 5 / 7                        Report Format Version: 6.1.1


2.4    Calculation Result Of Maximum Conducted Power

The EUT contains WiFi module and LTE module, they can transmit at same time. For more details please
refer to as below:
               Model                             Contains WIFI /LTE Certified Module
     SC3-32A-H, SC3-32A-N      FCC ID: PPQSC3US (WiFi)
    IC3-32A-H-A, IC3-32A-N-A   FCC ID: 2ADWC-AI7688H (WiFi), FCC ID: QIPELS61-US (LTE)
   IC3-32A-H-V, IC3-32A-N-V    FCC ID: PPQIC3V (WiFi & LTE)

EUT (RFID):
 Frequency Band           Max Power (EIRP)      Distance               Power Density               Limit
      (MHz)                    (dBm)              (cm)                   (mW/cm2)                (mW/cm2)
       13.56                   -16.9                 20                 0.00000406                 0.978
NOTE:
1. Max Power: 78.30dBuV/m = -16.9dBm
2. Determining compliance based on the results of the compliance measurement, not taking into account
   measurement instrumentation uncertainty.

For Model: SC3‐32A‐N, SC3‐32A‐H
WLAN module FCC ID: PPQSC3US
 Frequency Band   Max Power              Antenna Gain          Distance       Power Density              Limit
      (MHz)         (dBm)                    (dBi)               (cm)           (mW/cm2)               (mW/cm2)
    2412-2462        17.92                     2                  20             0.0195                    1


For Model: IC3‐32A‐H‐A, IC3‐32A‐N‐A
WLAN module FCC ID: 2ADWC-AI7688H
 Frequency Band   Max Power    Antenna Gain                    Distance       Power Density              Limit
      (MHz)          (dBm)         (dBi)                         (cm)           (mW/cm2)               (mW/cm2)
    2412-2462          20            2                            20              0.03                     1

LTE module FCC ID: QIPELS61-US
Band 2
        Frequency Band                        EIRP             Distance        Power Density              Limit
             (MHz)                           (dBm)               (cm)            (mW/cm2)               (mW/cm2)
WCDMA: 1850MHz ~ 1910MHz                     23.68                20               0.05                     1
LTE Band 2: 1850MHz ~ 1910MHz                23.10                20                 0.04                    1
Band 4
         Frequency Band                       EIRP             Distance        Power Density              Limit
              (MHz)                          (dBm)               (cm)            (mW/cm2)               (mW/cm2)
WCDMA: 1710MHz ~ 1755MHz                     23.63                20                 0.05                    1
LTE Band 4: 1710MHz ~ 1755MHz                23.11                20                 0.04                    1




Report No.: SA190417D14                       Page No. 6 / 7                                Report Format Version: 6.1.1


Band 5
                                                                                             Power
           Frequency Band                   ERP               EIRP            Distance                          Limit
                                                                                            Density
               (MHz)                       (dBm)             (dBm)              (cm)                          (mW/cm2)
                                                                                           (mW/cm2)
WCDMA: 824MHz ~ 849MHz                     23.93              26.08             20            0.08                  0.55
LTE Band 5: 824MHz ~ 849MHz                23.12              25.27             20              0.07                0.55
Note: EIRP = ERP + 2.15
Band 12
                                                                                             Power
           Frequency Band                   ERP               EIRP            Distance                          Limit
                                                                                            Density
               (MHz)                       (dBm)             (dBm)              (cm)                          (mW/cm2)
                                                                                           (mW/cm2)
LTE Band 12: 698MHz ~ 711MHz               23.26              25.41             20            0.07                  0.47
Note: EIRP = ERP + 2.15

For Model: IC3‐32A‐H‐V, IC3‐32A‐N‐V
WLAN & LTE module FCC ID:PPQIC3V
WLAN
Frequency Band  Max Power     Antenna Gain                        Distance        Power Density             Limit
    (MHz)          (dBm)          (dBi)                             (cm)            (mW/cm2)              (mW/cm2)
   2412-2462              17.92              2                      20                 0.0195                   1

LTE Band 4
         Frequency Band                      EIRP                  Distance          Power Density            Limit
             (MHz)                          (dBm)                    (cm)              (mW/cm2)             (mW/cm2)
LTE Band 4: 1710MHz ~ 1755MHz               25.71                     20                0.0741                  1

LTE Band 13
                                                                                             Power
           Frequency Band                   ERP               EIRP            Distance                          Limit
                                                                                            Density
               (MHz)                       (dBm)             (dBm)              (cm)                          (mW/cm2)
                                                                                           (mW/cm2)
LTE Band 13: 777MHz ~ 787MHz          20.31                   22.46             20           0.0351                 0.52
Note: EIRP = ERP + 2.15
Conclusion:
The formula of calculated the MPE is:
CPD1 / LPD1 + CPD2 / LPD2 + ……etc. < 1
CPD = Calculation power density
LPD = Limit of power density

For Model: SC3‐32A‐N, SC3‐32A‐H
RFID + WLAN module FCC ID: PPQSC3US
0.00000406 /0.978 + 0.0195/1=0.019504

For Model: IC3‐32A‐H‐A, IC3‐32A‐N‐A
RFID + WLAN module FCC ID: 2ADWC-AI7688H + LTE module FCC ID: QIPELS61-US =
0.00000406 /0.978 + 0.03/1 + 0.07/0.47 = 0.044894

For Model: IC3‐32A‐H‐V, IC3‐32A‐N‐V
RFID + WLAN & LTE module FCC ID: PPQIC3V =
0.00000406 /0.978 +0.0195/1 + 0.0741/1 = 0.093604

Therefore the maximum calculations of above situations are less than the “1” limit.
--- END ---

Report No.: SA190417D14                          Page No. 7 / 7                                 Report Format Version: 6.1.1



Document Created: 2019-06-20 21:56:41
Document Modified: 2019-06-20 21:56:41

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC