test rep (doc)

FCC ID: PPQ-WZ400T

Test Report

Download: PDF
FCCID_1255486

                                                                        Report No. 103063R-RFUSP37V02




                                       Test Report

                     Product Name                 2.4GHz ZigBee Module
                     Model No                     WZ400T
                     FCC ID.                      DoC




             Applicant Lite-On Technology Corp.
             Address        4F,90,Chien 1 Road,Chung-Ho,Taipei Hsien
                            235,Taiwan,R.O.C.




                      Date of Receipt            Mar. 02, 2010
                      Issue Date                 Mar. 15, 2010
                      Report No.                 103063R-RFUSP37V02
                      Report Version             V1.0



The test results relate only to the samples tested.
The test report shall not be reproduced except in full without the written approval of QuieTek Corporation.
This report must not be used to claim product endorsement by NVLAP any agency of the U.S. Government




                                              Page : 1 of 23


                                                                         Report No. 103063R-RFUSP37V02




                           Tes t R e p o r t C e r t i f i c a t i o n
                                                                    Issue Date: Mar. 15, 2010
                                                                    Report No.: 103063R-RFUSP37V02




                                          Accredited by NIST (NVLAP)
                                           NVLAP Lab Code: 200533-0

    Product Name                2.4GHz ZigBee Module

    Applicant                   Lite-On Technology Corp.

    Address                     4F,90,Chien 1 Road,Chung-Ho,Taipei Hsien 235,Taiwan,R.O.C.

    Manufacturer                DONG GUAN G-COM COMPUTER CO., LTD.

    Model No.                   WZ400T

    FCC ID.                     DoC

    EUT Rated Voltage           DC 3V

    EUT Test Voltage            DC 3V

    Trade Name                  Lite-On

    Applicable Standard         FCC CFR Title 47 Part 15 Subpart B: 2008

                                ANSI C63.4: 2003

    Test Result                 Complied

The test results relate only to the samples tested.
The test report shall not be reproduced except in full without the written approval of QuieTek Corporation.
This report must not be used to claim product endorsement by NVLAP any agency of the U.S. Government


  Documented By :

                              ( Adm. Specialist / Leven Huang)

  Tested By            :


                                  (Engineer / Eason Hung)

  Approved By          :


                                   ( Manager / Vincent Lin)


                                               Page : 2 of 23


                                                                                                    Report No. 103063R-RFUSP37V02



                                              TA B L E O F C O N T E N T S
     Description                                                                                                                    Page
1.                 GENERAL INFORMATION............................................................................................ 4
1.1.               EUT Description ............................................................................................................. 4
1.2.               Tested System Details .................................................................................................... 6
1.3.               Configuration of Tested System...................................................................................... 6
1.4.               EUT Exercise Software .................................................................................................. 6
1.5.               Test Facility..................................................................................................................... 8
2.                 Conducted Emission.................................................................................................... 9
2.1.               Test Equipment............................................................................................................... 9
2.2.               Test Setup ...................................................................................................................... 9
2.3.               Limits ............................................................................................................................ 10
2.4.               Test Procedure ............................................................................................................. 10
2.5.               Uncertainty ................................................................................................................... 10
2.6.               Test Result of Conducted Emission.............................................................................. 11
3.                 Radiated Emission ..................................................................................................... 13
3.1.               Test Equipment............................................................................................................. 13
3.2.               Test Setup .................................................................................................................... 14
3.3.               Limits ............................................................................................................................ 15
3.4.               Test Procedure ............................................................................................................. 15
3.5.               Uncertainty ................................................................................................................... 16
3.6.               Test Result of Radiated Emission................................................................................. 17
4.                 EMI Reduction Method During Compliance Testing ............................................... 21

Attachment 1:        EUT Test Photographs
Attachment 2:        EUT Detailed Photographs




                                                                Page : 3 of 23


                                                                   Report No. 103063R-RFUSP37V02




1.         GENERAL INFORMATION

1.1.       EUT Description

     Product Name             2.4GHz ZigBee Module
     Trade Name               Lite-On
     Model No.                WZ400T
     FCC ID.                  DoC
     Frequency Range          2405-2475MHz
     Number of Channels       15CH
     Type of Modulation       DSSS (O-QPSK)
     Antenna Type             Monopole Antenna
     Antenna Gain             Refer to the table “Antenna List”
     Channel Control          Auto


     Antenna List
     No.   Manufacturer          Part No.                         Peak Gain
     1     DONG GUAN G-COM       N/A                              1.5dBi for 2.4 GHz
           COMPUTER
     Note: The antenna of EUT is conform to FCC 15.203




                                            Page : 4 of 23


                                                                  Report No. 103063R-RFUSP37V02



Center Frequency of Each Channel:
 Channel Frequency Channel           Frequency    Channel      Frequency Channel Frequency
Channel 01: 2405 MHz Channel 02:     2410 MHz    Channel 03:   2415 MHz Channel 04: 2420 MHz
Channel 05: 2425 MHz Channel 06:     2430 MHz    Channel 07:   2435 MHz Channel 08: 2440 MHz
Channel 09: 2445 MHz Channel 10:     2450 MHz    Channel 11:   2455 MHz Channel 12: 2460 MHz
Channel 13: 2465 MHz Channel 14:     2470 MHz    Channel 15:   2475 MHz



   Note:
   1.   The EUT is a 2.4GHz ZigBee Module.
   2.   Regarding to the operation frequency, the lowest, middle and highest frequency are selected
        to perform the test.
   3.   These tests are conducted on a sample for demonstrating the compliance of ZigBee receiver
        with Part 15 Subpart B.
   4.   Part 15 Subpart C compliance for spread spectrum devices is shown on the report no.
        103063R-RFUSP29V01 and certified under FCC ID: PPQ-WZ400T.


 Test Mode:          Mode 1: Receive




                                           Page : 5 of 23


                                                                          Report No. 103063R-RFUSP37V02




1.2.      Tested System Details

          The types for all equipment, plus descriptions of all cables used in the tested system
          (including inserted cards) are:

Product                  Manufacturer          Model No.         Serial No.           Power Cord
1   Test Fixture         DONG GUAN G-COM       N/A               N/A                  N/A
2   Notebook P.C.        DELL                  PPT               N/A                  Non-Shielded, 0.8m
3   DC Power Supply Agilent                    E3646A            MY40003414           Non-Shielded, 1.8m


                   Signal Cable Type                               Signal cable Description
A      Signal Cable                                  Non-Shielded, 0.3m
B      USB Cable                                     Non-Shielded, 1.2m
C      DC Power Cable                                Non-Shielded, 0.8 m


1.3.      Configuration of Tested System




                                              Page : 6 of 23


                                                            Report No. 103063R-RFUSP37V02


1.4.   EUT Exercise Software

       (1)   Setup the EUT as shown in section 1.3
       (2)   Execute the “Smart RF” program (Ver 6.13.0.0) on the notebook.
       (3)   Setup the test mode, and channel.
       (4)   Press OK to start the transmission.
       (5)   Verify that the EUT works correctly.




                                        Page : 7 of 23


                                                                          Report No. 103063R-RFUSP37V02




1.5.   Test Facility

       Ambient conditions in the laboratory:
                 Items                Required (IEC 68-1)                  Actual
       Temperature (C)            15-35                        20-35
       Humidity (%RH)              25-75                        50-65
       Barometric pressure         860-1060                     950-1000
       (mbar)

       The related certificate for our laboratories about the test site and management system can be downloaded
       from QuieTek Corporation’s Web Site : http://tw.quietek.com/tw/emc/accreditations/accreditations.htm
       The address and introduction of QuieTek Corporation’s laboratories can be founded in our Web site :
       http://www.quietek.com/

       Site Description: File on
                         Federal Communications Commission
                         FCC Engineering Laboratory
                         7435 Oakland Mills Road
                         Columbia, MD 21046
                         Registration Number: 92195

                           Accreditation on NVLAP
                           NVLAP Lab Code: 200533-0

       Site Name:          Quietek Corporation
       Site Address:       No. 5-22, Ruei-Shu Valley, Ruei-Ping Tsuen,
                           Lin-Kou Shiang, Taipei,
                           Taiwan, R.O.C.
                           TEL: 886-2-8601-3788 / FAX : 886-2-8601-3789
                           E-Mail : service@quietek.com

       FCC Accreditation Number: TW1014




                                               Page : 8 of 23


                                                                             Report No. 103063R-RFUSP37V02




2.     Conducted Emission

2.1.   Test Equipment

       The following test equipment are used during the conducted emission test:

       Item Instrument                 Manufacturer Type No./Serial No           Last Cal.       Remark
       1    Test Receiver              R&S                ESCS 30/825442/17      May, 2009
       2    L.I.S.N.                   R&S                ESH3-Z5/825016/6       May, 2009       EUT
       3    L.I.S.N.                   Kyoritsu           KNW-407/8-1420-3       May, 2009       Peripherals
       4    Pulse Limiter              R&S                ESH3-Z2                May, 2009
       5    No.1 Shielded Room                                                   N/A
       Note: All instruments are calibrated every one year.



2.2.   Test Setup
                                                                              Reference Plane


                       Test Receiver
                                                                                                40cm


                  12dBuV                                                     EUT
                                                                Load
                  




                                                      LISN                                      LISN


                                                                                 LISN
                                       Ground Plane




                                                      Page : 9 of 23


                                                                     Report No. 103063R-RFUSP37V02




2.3.   Limits

                    FCC Part 15 Subpart B Paragraph 15.107 (dBuV) Limit

                      Frequency                             Limits

                         MHz
                                               QP                     AVG

                      0.15 - 0.50             66-56                   56-46

                       0.50-5.0                56                      46

                       5.0 - 30                60                      50


2.4.   Test Procedure

       The EUT and simulators are connected to the main power through a line impedance
       stabilization network (L.I.S.N.). This provides a 50 ohm /50uH coupling impedance for the
       measuring equipment. The peripheral devices are also connected to the main power
       through a LISN that provides a 50ohm /50uH coupling impedance with 50ohm
       termination. (Please refers to the block diagram of the test setup and photographs.)
       Both sides of A.C. line are checked for maximum conducted interference. In order to find
       the maximum emission, the relative positions of equipment and all of the interface cables
       must be changed according to ANSI C63.4: 2003 on conducted measurement.
       Conducted emissions were invested over the frequency range from 0.15MHz to 30MHz
       using a receiver bandwidth of 9kHz.



2.5.   Uncertainty

       ± 2.26 dB




                                          Page : 10 of 23


                                                                      Report No. 103063R-RFUSP37V02




2.6.         Test Result of Conducted Emission

             Product      :      2.4GHz ZigBee Module
             Test Item    :      Conducted Emission Test
             Power Line   :      Line 1
             Test Mode    :      Mode 1: Receive (2440MHz)


   Frequency              Correct          Reading      Measurement       Margin          Limit
                          Factor            Level            Level
        MHz                    dB           dBuV             dBuV           dB            dBuV
       Line 1
  Quasi-Peak
        0.916                 9.670        23.570            33.240       -22.760        56.000
        1.607                 9.680        23.070            32.750       -23.250        56.000
        2.228                 9.680        27.650            37.330       -18.670        56.000
        4.127                 9.700        31.080            40.780       -15.220        56.000
        5.677                 9.720        40.270            49.990       -10.010        60.000
        9.681                 9.830        33.250            43.080       -16.920        60.000
   Average
        0.916                 9.670        13.430            23.100       -22.900        46.000
        1.607                 9.680        17.230            26.910       -19.090        46.000
        2.228                 9.680        11.380            21.060       -24.940        46.000
        4.127                 9.700        21.210            30.910       -15.090        46.000
        5.677                 9.720        29.140            38.860       -11.140        50.000
        9.681                 9.830        25.680            35.510       -14.490        50.000


Note:
        1.   All Reading Levels are Quasi-Peak and average value.
        2.   “   “ means the worst emission level.
        3.   Measurement Level = Reading Level + Correct Factor




                                                Page : 11 of 23


                                                                     Report No. 103063R-RFUSP37V02



          Product       :      2.4GHz ZigBee Module
          Test Item     :      Conducted Emission Test
          Power Line    :      Line 2
          Test Mode     :      Mode 1: Receive(2440MHz)


  Frequency             Correct          Reading       Measurement       Margin          Limit
                         Factor           Level             Level
        MHz                  dB           dBuV              dBuV           dB            dBuV
    Line 2
  Quasi-Peak
        1.619               9.680        23.810            33.490        -22.510        56.000
        2.330               9.680        26.520            36.200        -19.800        56.000
        4.033               9.700        30.120            39.820        -16.180        56.000
        5.584               9.720        38.890            48.610        -11.390        60.000
        9.599               9.820        34.150            43.970        -16.030        60.000
    15.869               10.000          24.380            34.380        -25.620        60.000
   Average
        1.619               9.680        18.070            27.750        -18.250        46.000
        2.330               9.680         8.420            18.100        -27.900        46.000
        4.033               9.700        21.650            31.350        -14.650        46.000
        5.584               9.720        28.610            38.330        -11.670        50.000
        9.599               9.820        25.610            35.430        -14.570        50.000
    15.869               10.000          17.310            27.310        -22.690        50.000




Note:
    1. All Reading Levels are Quasi-Peak and average value.
    2. “        “ means the worst emission level.
    3. Measurement Level = Reading Level + Correct Factor




                                               Page : 12 of 23


                                                                       Report No. 103063R-RFUSP37V02




3.        Radiated Emission

3.1.      Test Equipment

          The following test equipment are used during the radiated emission test:
     Test Site         Equipment             Manufacturer        Model No./Serial No.        Last Cal.
      Site # 3 X    Bilog Antenna          Schaffner Chase CBL6112B/2673                    Sep., 2009
              X     Horn Antenna           Schwarzbeck       BBHA9120D/D305                 Sep., 2009
              X     Horn Antenna           Schwarzbeck       BBHA9170/208                   Jul., 2009
              X     Pre-Amplifier          AGILENT           8447D/2944A09549               Sep., 2009
              X     Test Receiver          R&S               ESCS 30/ 825442/018            Sep., 2009
              X     Spectrum Analyzer      Advantest         R3162/91700283                 Oct., 2009
              X     Coaxial Cable          QuieTek           QTK-CABLE/ CAB5                Feb., 2010
              X     Controller             QuieTek           QTK-CONTROLLER/ CTRL3             N/A
              X     Coaxial Switch         Anritsu           MP59B/6200265729                  N/A
          Note: 1. All equipments are calibrated with traceable calibrations. Each calibration is
                  traceable to the national or international standards.
                   2. The test instruments marked with “X” are used to measure the final test results.




                                               Page : 13 of 23


                                                                          Report No. 103063R-RFUSP37V02




3.2.   Test Setup

 Radiated Emission Below 1GHz


                                                            3m


                   FRP Dome
                                                                                                           1m to 4m




                                                                  The height of broad
                                                                  band antenna was
                                                                  scanned from 1m to 4m.

                                                                  The distance between
                                  EUT                             antenna and turn table
           Non-Conducted Table
                                                                  was 3m..
                                        80cm


                                                 Fully soldered Metal Ground                       To Controller
               Test                                                                                    To Receiver
             Receiver




 Radiated Emission Above 1GHz




                                                             3m


                 FRP Dome



                                                                   The height of broad band
                                                                   or Dipole Antenna was
                                                                   scanned from 1M to 4M.

                                                                   The distance between
                                 EUT                               antenna and turn table
                                                                   was 3M regards to the
                                                                   standard adopted.
                                        80cm


                                                                                     To Receiver       Pre-
                                                                                                     Amplifier




                                          Page : 14 of 23


                                                                     Report No. 103063R-RFUSP37V02




3.3.   Limits



                         FCC Part 15 Subpart B Paragraph 15.109 Limits
                     Frequency
                        MHz                  uV/m @3m                dBuV/m@3m

                        30-88                     100                      40

                       88-216                     150                     43.5

                      216-960                     200                      46

                     Above 960                    500                      54

       Remarks : 1. RF Voltage (dBuV) = 20 log RF Voltage (uV)
                   2. In the Above Table, the tighter limit applies at the band edges.
                   3. Distance refers to the distance in meters between the measuring instrument
                        antenna and the closed point of any part of the device or system.

3.4.   Test Procedure

       The EUT and its simulators are placed on a turn table which is 0.8 meter above ground.
       The turn table can rotate 360 degrees to determine the position of the maximum emission
       level. The EUT was positioned such that the distance from antenna to the EUT was 3
       meters.
       The antenna is scanned between 1 meter and 4 meters to find out the maximum emission
       level. This is repeated for both horizontal and vertical polarization of the antenna. In order to
       find the maximum emission, all of the interface cables were manipulated according to ANSI
       C63.4:2003 on radiated measurement.
       The resolution bandwidth below 1GHz setting on the field strength meter is 120 kHz and
       above 1GHz is 1MHz.
       Radiated emission measurements below 1GHz are made using broadband Bilog antenna
       and above 1GHz are made using Horn Antennas.
        The measurement is divided into the Preliminary Measurement and the Final
        Measurement.
        The suspected frequencies are searched for in Preliminary Measurement with the
       measurement antenna kept pointed at the source of the emission both in azimuth and
       elevation, with the polarization of the antenna oriented for maximum response. The antenna
       is pointed at an angle towards the source of the emission, and the EUT is rotated in both
       height and polarization to maximize the measured emission. The emission is kept within the
       illumination area of the 3 dB bandwidth of the antenna.
        The worst radiated emission is measured in the Open Area Test Site on the Final
        Measurement.
       The measurement frequency range from 30MHz - 10th Harmonic of fundamental was
       investigated.

                                             Page : 15 of 23


                                               Report No. 103063R-RFUSP37V02




3.5.   Uncertainty

       ± 3.9 dB above 1GHz
       ± 3.8 dB below 1GHz




                             Page : 16 of 23


                                                                        Report No. 103063R-RFUSP37V02




3.6.         Test Result of Radiated Emission

             Product     :      2.4GHz ZigBee Module
             Test Item   :      Harmonic Radiated Emission Data
             Test Site   :      No.3 OATS
             Test Mode   :      Mode 1: Receive(2405MHz)


   Frequency             Correct          Reading       Measurement          Margin             Limit
                          Factor           Level             Level
        MHz                   dB           dBuV            dBuV/m              dB             dBuV/m
  Horizontal
Peak Detector:
   2405.000               -1.056           37.960           36.904           -37.096           74.000
   4810.000                  3.142         43.120           46.262           -27.738           74.000
   7415.000              12.264            35.640           47.904           -26.096           74.000
   Average
   Detector:
            --
       Vertical
Peak Detector:
   2405.000               -1.722           42.250           40.527           -33.473           74.000
   4810.000                  6.410         42.320           48.730           -25.270           74.000
   7215.000              11.056            36.690           47.747           -26.253           74.000
   Average
   Detector:
            --



Note:
    1.      All Readings below 1GHz are Quasi-Peak, above are performed with peak and/or average
            measurements as necessary.
       2.   Receiver setting (Peak Detector) : RBW:1MHz; VBW:3MHz; Span:10MHz。
       3.   Receiver setting (AVG Detector) : RBW:1MHz; VBW:10Hz; Span:10MHz。
       4.   Emission Level = Reading Level + Correct Factor.
       5.   The average measurement was not performed when the peak measured data under the limit
            of average detection. If the readings given are average, peak measurement should also be
            supplied.
       6.   The emission levels of other frequencies are very lower than the limit and not show in test
             report.




                                                Page : 17 of 23


                                                                      Report No. 103063R-RFUSP37V02



          Product      :      2.4GHz ZigBee Module
          Test Item    :      Harmonic Radiated Emission Data
          Test Site    :      No.3 OATS
          Test Mode    :      Mode 1: Receive(2440MHz)

  Frequency            Correct          Reading       Measurement          Margin             Limit
                       Factor            Level             Level
     MHz                    dB           dBuV            dBuV/m              dB             dBuV/m
  Horizontal
Peak Detector:
   2440.000            -0.836            37.560           36.724           -37.276           74.000
   4880.000                2.896         40.300           43.196           -30.804           74.000
   7320.000            11.769            35.390           47.159           -26.841           74.000
   Average
   Detector:
         --
    Vertical
Peak Detector:
   2440.000            -1.549            36.960           35.411           -38.589           74.000
   4880.000                5.624         40.040           45.664           -28.336           74.000
   7320.000            12.639            34.820           47.459           -26.541           74.000
   Average
   Detector:
         --



Note:
    1.   All Readings below 1GHz are Quasi-Peak, above are performed with peak and/or average
         measurements as necessary.
    2.   Receiver setting (Peak Detector) : RBW:1MHz; VBW:3MHz; Span:10MHz。
    3.   Receiver setting (AVG Detector) : RBW:1MHz; VBW:10Hz; Span:10MHz。
    4.   Emission Level = Reading Level + Correct Factor.
    5.   The average measurement was not performed when the peak measured data under the limit
         of average detection. If the readings given are average, peak measurement should also be
         supplied.
    6.    The emission levels of other frequencies are very lower than the limit and not show in test
          report.




                                              Page : 18 of 23


                                                                   Report No. 103063R-RFUSP37V02



          Product     :      2.4GHz ZigBee Module
          Test Item   :      Harmonic Radiated Emission Data
          Test Site   :      No.3 OATS
          Test Mode   :      Mode 1: Receive(2475MHz)

  Frequency           Correct          Reading       Measurement        Margin            Limit
                      Factor            Level             Level
     MHz                   dB           dBuV            dBuV/m            dB            dBuV/m
  Horizontal
Peak Detector:
   2475.000           -0.612            37.580           36.968        -37.032           74.000
   4950.000               2.741         37.760           40.501        -33.499           74.000
   7425.000           12.337            35.230           47.567        -26.433           74.000
   Average
   Detector:
         --
    Vertical
Peak Detector:
   2475.000           -1.352            37.490           36.138         -37.862          74.000
   4950.000               5.501         40.450           45.950         -28.050          74.000
   7425.000           13.317            34.970           48.287         -25.713          74.000
   Average
   Detector:
         --



Note:
    1.   All Readings below 1GHz are Quasi-Peak, above are performed with peak and/or average
         measurements as necessary.
    2.   Receiver setting (Peak Detector) : RBW:1MHz; VBW:3MHz; Span:10MHz。
    3.   Receiver setting (AVG Detector) : RBW:1MHz; VBW:10Hz; Span:10MHz。
    4.   Emission Level = Reading Level + Correct Factor.
    5.   The average measurement was not performed when the peak measured data under the limit
         of average detection. If the readings given are average, peak measurement should also be
         supplied.
    6.   The emission levels of other frequencies are very lower than the limit and not show in test
          report.




                                             Page : 19 of 23


                                                                      Report No. 103063R-RFUSP37V02




             Product     :      2.4GHz ZigBee Module
             Test Item   :      General Radiated Emission Data
             Test Site   :      No.3 OATS
             Test Mode   :      Mode 1: Receive(2440 MHz)


  Frequency              Correct          Reading       Measurement       Margin            Limit
                          Factor            Level            Level
        MHz                   dB            dBuV           dBuV/m           dB            dBuV/m
  Horizontal
    30.000                   2.120         30.326           32.446        -7.554           40.000
    191.020              -10.040           46.784           36.744        -6.756           43.500
    297.720               -3.633           36.978           33.346        -12.654          46.000
    460.680                  1.589         36.916           38.505        -7.495           46.000
    544.100                  3.512         34.854           38.366        -7.634           46.000
   1000.000                  9.119         29.539           38.658        -15.342          54.000
    Vertical
    31.940                -0.487           34.241           33.755        -6.245           40.000
    196.840               -8.766           43.102           34.336        -9.164           43.500
    299.660               -6.855           35.094           28.239        -17.761          46.000
    507.240               -0.471           33.546           33.075        -12.925          46.000
    967.020                  8.071         27.305           35.376        -18.624          54.000
   1000.000                  4.329         30.863           35.192        -18.808          54.000


Note:
        1.   All Readings below 1GHz are Quasi-Peak, above are performed with peak and/or average
             measurements as necessary.
        2.   “   ” means the worst emission level.
        3.   Measurement Level = Reading Level + Correct Factor.
        4.   The radiated emissions below 1GHz of the lowest, middle, highest frequency are pretested.
             Only the worst case is shown on the report.




                                                Page : 20 of 23


                                                         Report No. 103063R-RFUSP37V02




4.   EMI Reduction Method During Compliance Testing



     No modification was made during testing.




                                       Page : 21 of 23



Document Created: 2010-03-18 17:16:46
Document Modified: 2010-03-18 17:16:46

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC