rf exp

FCC ID: PPQ-WZ400T

RF Exposure Info

Download: PDF
FCCID_1255465

                                                                            Report No. 103063R-RFUSP29V01




          RF Exposure Evaluation declaration


                        Product Name : 2.4GHz ZigBee Module
                        Model No.            : WZ400T
                        FCC ID               : PPQ-WZ400T




            Applicant : Lite-On Technology Corp.
            Address : 4F,90,Chien 1 Road,Chung-Ho,Taipei Hsien
                             235,Taiwan,R.O.C.




                         Date of Receipt        : Mar. 02, 2010

                         Date of Declaration : Mar. 15, 2010

                         Report No.             : 103063R-RFUSP29V01




The declaration results relate only to the samples calculated.
The declaration shall not be reproduced except in full without the written approval of QuieTek Corporation.
This report must not be used to claim product endorsement by NVLAP any agency of the U.S. Government




                                             Page: 1 of 3                                          Version: 1.0


                                                                            Report No. 103063R-RFUSP29V01


1.      RF Exposure Evaluation

1.1.    Limits

        According to FCC 1.1310: The criteria listed in the following table shall be used to evaluate the
        environment impact of human exposure to radio frequency (RF) radiation as specified in 1.1307(b)
        LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE)
        Frequency Range       Electric Field       Magnetic Field      Power Density        Average Time
                                                                                 2
        (MHz)                 Strength (V/m)       Strength (A/m)      (mW/cm )             (Minutes)
                                    (A) Limits for Occupational/ Control Exposures
               300-1500                  --                    --             F/300                  6
           1500-100,000                  --                    --                5                   6
                              (B) Limits for General Population/ Uncontrolled Exposures
               300-1500                  --                    --             F/1500                 6
           1500-100,000                  --                    --                1                   30
        F= Frequency in MHz


       Friis Formula
       Friis transmission formula: Pd = (Pout*G)/(4*pi*r2)


       Where
       Pd = power density in mW/cm2
       Pout = output power to antenna in mW
       G = gain of antenna in linear scale
       Pi = 3.1416
       R = distance between observation point and center of the radiator in cm


       Pd id the limit of MPE, 1 mW/cm2 . If we know the maximum gain of the antenna and the total power
       input to the antenna, through the calculation, we will know the distance r where the MPE limit is
       reached.



1.2.    Test Procedure

         Software provided by client enabled the EUT to transmit and receive data at lowest, middle and
         highest channel individually.
         The temperature and related humidity: 18℃and 78% RH.




                                                Page: 2 of 3                                     Version: 1.0


                                                                         Report No. 103063R-RFUSP29V01




1.3.        Test Result of RF Exposure Evaluation

            Product        :    2.4GHz ZigBee Module
            Test Item      :    RF Exposure Evaluation
            Test Site      :    No.3 OATS


Antenna Gain
Antenna Gain: The maximum Gain measured in fully anechoic chamber is 1.5 dBi in logarithm scale.



Zigbee Output Power Into Antenna & RF Exposure Evaluation Distance (1.5 dBi):
                                             Output Power to Antenna   Power Density at R = 20 cm
   Channel              Frequency (MHz)
                                                         (mW)                 (mW/cm2)
       1                    2405.00                  71.9449                   0.020218

       8                    2440.00                  62.2300                   0.017488

       15                   2475.00                  48.8652                   0.013732
The RF exposure at 20 cm is below limit.




                                                 Page: 3 of 3                               Version: 1.0



Document Created: 2010-03-23 09:50:19
Document Modified: 2010-03-23 09:50:19

© 2024 FCC.report