MPE

FCC ID: PPQ-WN4616L

RF Exposure Info

Download: PDF
FCCID_2308900

                 RF Exposure Report                                                 Report No. : FA460708



1         Maximum Permissible Exposure
1.1       Maximum Permissible Exposure
1.1.1     Limit of Maximum Permissible Exposure
                             Limits for Occupational / Controlled Exposure
                                                                                         Averaging Time
 Frequency Range         Electric Field      Magnetic Field      Power Density (S)
                                                                                          |E|²,|H|² or S
      (MHz)            Strength (E) (V/m)   Strength (H) (A/m)      (mW/ cm²)
                                                                                            (minutes)
        0.3-3.0                614                 1.63                (100)*                    6
        3.0-30               1,842 / f            4.89 / f            (900 / f2)*                6
        30-300                 61.4               0.163                  1.0                     6
      300-1,500                                                         F/300                    6
    1,500-100,000                                                         5                      6
                        Limits for General Population / Uncontrolled Exposure
                                                                                         Averaging Time
 Frequency Range         Electric Field      Magnetic Field      Power Density (S)
                                                                                          |E|²,|H|² or S
      (MHz)            Strength (E) (V/m)   Strength (H) (A/m)      (mW/ cm²)
                                                                                            (minutes)
        0.3-1.34               614                 1.63                (100)*                    30
                                                                               2
        1.34-30               824/f               2.19/f              (180/f )*                  30
        30-300                 27.5               0.073                  0.2                     30
      300-1,500                                                        F/1500                    30
    1,500-100,000                                                        1.0                     30
Note 1: f = frequency in MHz ; *Plane-wave equivalent power density
Note 2: For the applicable limit, see FCC 1.1310



1.1.2     MPE Calculation Method
                                                                           2
E (V/m) =     30  P  G                    Power Density: Pd (W/m2) = E
                  d                                                      377
E = Electric field (V/m)                    P = RF output power (W)
G = EUT Antenna numeric gain (numeric)      d = Separation distance between radiator and human body (m)
The formula can be changed to
Pd = 30  P  G
        377  d 2




SPORTON INTERNATIONAL INC.                                             Page No.            : 1 of 2
TEL : 886-3-327-3456                                                   Report Version      : Rev. 01
FAX : 886-3-327-0973


                RF Exposure Report                                                        Report No. : FA460708


1.1.3     Result of Maximum Permissible Exposure
                                             RF General Information
                         IEEE Std.                                            Number of
   Frequency                              Ch. Frequency       Channel                             RF Output
                           802.11                                              Transmit
  Range (MHz)                                 (MHz)           Number                             Power (dBm)
                          Protocol                                           Chains (NTX)
   2400-2483.5               b              2412-2462         1-11 [11]              1                24.54
   2400-2483.5               g              2412-2462         1-11 [11]              1                22.18
   2400-2483.5            n (HT20)          2412-2462         1-11 [11]              2                23.32
   2400-2483.5            n (HT40)          2422-2452          3-9 [7]               2                18.31
Note 1: RF output power specifies that Maximum Conducted (Average) Output Power.



                                     Worst Maximum RF Output Power Result
    Exposure Environment             General Population / Uncontrolled Exposure
  Separation Distance (cm)           20
            Condition                                       RF Output Power (dBm)
                                       RF Output                                                    PD (S)
    Modulation Mode           NTX                       Ant. Gain (dBi)     EIRP Power              (mW/cm²)
                                      Power (dBm)
             11b                 1         24.54             2.21                 26.75              0.094
             11b                 1         24.54             2.39                 26.93              0.098
                       Maximum Permissible Exposure Limit (mW/cm²)                                      1
Note 1: NTX = Number of Transmit Chains




SPORTON INTERNATIONAL INC.                                                   Page No.            : 2 of 2
TEL : 886-3-327-3456                                                         Report Version      : Rev. 01
FAX : 886-3-327-0973



Document Created: 2018-08-12 01:24:36
Document Modified: 2018-08-12 01:24:36

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC