Test Report_rev.pdf

FCC ID: PPQ-RPT01

Test Report

Download: PDF
FCCID_4063207

                                                               FCC Test Report

                       Report No.: RF180718D12-1

                            FCC ID: PPQ-RPT01

                       Test Model: RPT01

                 Received Date: July 18, 2018

                         Test Date: Aug. 05 to Oct. 17, 2018

                     Issued Date: Oct. 26, 2018


                         Applicant: LITE-ON Technology Corp.

                          Address: Bldg. C, 90, Chien 1 Rd., Chung-Ho,New Taipei City,23585,Taiwan



                        Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch
                                   Hsin Chu Laboratory
                    Lab Address: E-2, No.1, Li Hsin 1st Road, Hsinchu Science Park, Hsinchu City 300,
                                 Taiwan R.O.C.
            Test Location: E-2, No.1, Li Hsin 1st Road, Hsinchu Science Park, Hsinchu City 300,
                           Taiwan R.O.C.
       FCC Registration /
                           723255 / TW2022
      Designation Number:




This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted
only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this
report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product
unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you
provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided,
however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific
mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification. The report
must not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies.

Report No.: RF180718D12-1                                            Page No. 1 / 28                                            Report Format Version: 6.1.1


                                                                   Table of Contents
Release Control Record .................................................................................................................................. 3
1         Certificate of Conformity ...................................................................................................................... 4
2         Summary of Test Results ..................................................................................................................... 5
    2.1      Measurement Uncertainty ................................................................................................................... 5
    2.2      Modification Record ............................................................................................................................ 5
3         General Information .............................................................................................................................. 6
    3.1      General Description of EUT ................................................................................................................ 6
    3.2      Description of Test Modes ................................................................................................................... 7
    3.2.1    Test Mode Applicability and Tested Channel Detail ............................................................................. 8
    3.3      Description of Support Units ............................................................................................................... 9
    3.3.1    Configuration of System under Test .................................................................................................. 10
    3.4      General Description of Applied Standards ......................................................................................... 11
4         Test Types and Results ...................................................................................................................... 12
    4.1      Radiated Emission and Bandedge Measurement ............................................................................. 12
    4.1.1    Limits of Radiated Emission and Bandedge Measurement .............................................................. 12
    4.1.2    Test Instruments ................................................................................................................................ 13
    4.1.3    Test Procedures ................................................................................................................................. 15
    4.1.4    Deviation from Test Standard ............................................................................................................ 15
    4.1.5    Test Setup .......................................................................................................................................... 16
    4.1.6    EUT Operating Conditions................................................................................................................. 17
    4.1.7    Test Results ....................................................................................................................................... 18
    4.2      Conducted Emission Measurement .................................................................................................. 23
    4.2.1    Limits of Conducted Emission Measurement .................................................................................... 23
    4.2.2    Test Instruments ................................................................................................................................ 23
    4.2.3    Test Procedures ................................................................................................................................. 24
    4.2.4    Deviation from Test Standard ............................................................................................................ 24
    4.2.5    Test Setup .......................................................................................................................................... 24
    4.2.6    EUT Operating Conditions................................................................................................................. 24
    4.2.7    Test Results ....................................................................................................................................... 25
5         Pictures of Test Arrangements .......................................................................................................... 27
Appendix – Information on the Testing Laboratories ................................................................................ 28




Report No.: RF180718D12-1                                            Page No. 2 / 28                                             Report Format Version: 6.1.1


                                           Release Control Record


Issue No.              Description                                         Date Issued
RF180718D12-1          Original release.                                   Oct. 26, 2018




Report No.: RF180718D12-1                     Page No. 3 / 28       Report Format Version: 6.1.1


1    Certificate of Conformity


            Product: Repeater

              Brand:

        Test Model: RPT01

    Sample Status: ENGINEERING SAMPLE

          Applicant: LITE-ON Technology Corp.

          Test Date: Aug. 05 to Oct. 17, 2018

         Standards: 47 CFR FCC Part 15, Subpart C (Section 15.249)
                        ANSI C63.10: 2013



The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd.,
Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data
evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts
of the measurements of the sample’s EMC characteristics under the conditions specified in this report.




      Prepared by :                                             ,   Date:       Oct. 26, 2018
                              Claire Kuan / Specialist




     Approved by :                                              ,   Date:       Oct. 26, 2018
                                 May Chen / Manager




Report No.: RF180718D12-1                     Page No. 4 / 28                        Report Format Version: 6.1.1


                                                                                                             Eooert
                                                                                                              venitas



2      Summary of Test Results


                               47 CFR FCC Part 15, Subpart C (SECTION 15.249)

        FCC
                                 Test Item                  Result                        Remarks
       Clause
                                                                       Meet the requirement of limit.
       15.207        AC Power Conducted Emission             PASS      Minimum passing margin is —15.620B
                                                                       at 0.15000MHz.
                   Radiated Emission Test
                   B       E   M
       15.209        .an.d_ dge Measurement                            Meet the requirement of limit.
                   Limit: 50dB less than the peak value                  Cl           .           ag
        15.249     of fundamental frequency or meet          PASS      Minimum passing margin is
      15.249 (d)       .       faas q m Y         .                    —2.8dB at 2311.00MHz & 2439.00MHz.
                   radiated emission limit in section
                   15.209



2.1      Measurement Uncertainty

Where relevant, the following measurement uncertainty levels have been estimated for tests performed on
the EUT as specified in CISPR 16—4—2:


                                                                                          Expanded Uncertainty
                    Measurement                                  Frequency                      (k=2) (®©)
          Conducted Emissions at mains ports                150kHz ~ 3O0MHz                       1.84 dB
            Radiated Emissions up to 1 GHz                   30MHz ~ 1GHz                         5.33 dB
                                                              1GHz ~ 6GHz                         5.10 dB
           Radiated Emissions above 1 GHz                    6GHz ~ 18GHz                         4.85 dB
                                                             18GHz ~ 40GHz                        5.24 dB


2.2      Modification Record
There were no modifications required for compliance.




Report No.: RF180718D12—1                       Page No. 5/ 28                             Report Format Version: 6.1.1


3     General Information
3.1     General Description of EUT

 Product                      Repeater
 Brand
 Test Model                   RPT01
 Status of EUT                ENGINEERING SAMPLE
 Power Supply Rating          5Vdc from power adapter
 Modulation Type              GFSK
 Transfer Rate                1Mbps
 Operating Frequency          2415~2459MHz
 Number of Channel            3
 Antenna Type                 Refer to Note
 Antenna Connector            Refer to Note
 Accessory Device             Adapter x 1
 Data Cable Supplied          NA
Note:
1. The EUT could be supplied with a power adapter as the following table:
No. Brand                               Model No.                 Spec.                                 Plug
                                                                  Input: 100-240V, 50/60Hz, 0.2A Max
        Shenzhen Keyu Power Supply
1                                       KA0601A-0501000BSU Output: 5V, 1000mA                           UK
       Technology Co., Ltd.
                                                                  DC output cable: Unshielded, 1.0m
                                                                  Input: 100-240V, 50/60Hz, 0.2A Max
        Shenzhen Keyu Power Supply
2                                       KA0601A-0501000EUU Output: 5V, 1000mA                           EU
       Technology Co., Ltd.
                                                                  DC output cable: Unshielded, 1.0m
                                                                  Input: 100-240V, 50/60Hz, 0.2A Max
        Shenzhen Keyu Power Supply
3                                       KA0601A-0501000USU Output: 5V, 1000mA                           FCC
       Technology Co., Ltd.
                                                                  DC output cable: Unshielded, 1.0m
Note:
1.    The adapter 1, 2 is as same as adapter 3; except for plug shape is different.
2.    From the above adapters, Adapter 3 was selected as representative adapter for the test and its data was
      recorded in this report.
2. The antenna provided to the EUT, please refer to the following table:
                                     Antenna Gain         Frequency
     Brand            Model                                                Antenna Type     Connecter Type
                                         (dBi)           range(GHz)
    Unictron         AA055A               2.5             2.4-2.4835       Chip Antenna             NA
3. The EUT was pre-tested under the following modes:
  Test Mode             Description
 Mode A                 Power from USB interface (Adapter)
 Mode B                 Power from USB interface (Laptop)
Note: From the above modes, the conducted emission worst case was found in Mode B. Therefore only the
       test data of the mode was recorded in this report.
4. The above EUT information is declared by manufacturer and for more detailed features description,
   please refer to the manufacturer's specifications or user's manual.




Report No.: RF180718D12-1                     Page No. 6 / 28                        Report Format Version: 6.1.1


3.2   Description of Test Modes

3 channels are provided to this EUT:
          Channel                  Frequency                     Channel        Frequency
             15                    2415 MHz                        39           2439 MHz
             59                    2459 MHz




Report No.: RF180718D12-1                      Page No. 7 / 28             Report Format Version: 6.1.1


3.2.1     Test Mode Applicability and Tested Channel Detail

EUT CONFIGURE                       APPLICABLE TO
                                                                                              DESCRIPTION
     MODE
                         RE1G           RE<1G              PLC

          -                  √              √                 √                                      -

               RE1G: Radiated Emission above 1GHz &    Bandedge
Where                                                                  RE<1G: Radiated Emission below 1GHz
               Measurement
               PLC: Power Line Conducted Emission                      APCM: Antenna Port Conducted Measurement

NOTE: The EUT had been pre-tested on the positioned of each 3 axis. The worst case was found when positioned on X-plane for below
      1GHz and Z-plane for above 1GHz.
NOTE: “-”means no effect.


 Radiated Emission Test (Above 1GHz):

        Pre-Scan has been conducted to determine the worst-case mode from all possible combinations
        between available modulations, data rates and antenna ports (if EUT with antenna diversity
        architecture).
        Following channel(s) was (were) selected for the final test as listed below.
          AVAILABLE CHANNEL                            TESTED CHANNEL                               MODULATION TYPE
                  15 to 59                                  15, 39, 59                                       GFSK



 Radiated Emission Test (Below 1GHz):

        Pre-Scan has been conducted to determine the worst-case mode from all possible combinations
        between available modulations, data rates and antenna ports (if EUT with antenna diversity
        architecture).
        Following channel(s) was (were) selected for the final test as listed below.
          AVAILABLE CHANNEL                            TESTED CHANNEL                               MODULATION TYPE
                  15 to 59                                        59                                         GFSK



 Power Line Conducted Emission Test:

        Pre-Scan has been conducted to determine the worst-case mode from all possible combinations
        between available modulations, data rates and antenna ports (if EUT with antenna diversity
        architecture).
        Following channel(s) was (were) selected for the final test as listed below.
          AVAILABLE CHANNEL                            TESTED CHANNEL                               MODULATION TYPE
                  15 to 59                                        59                                         GFSK




Test Condition:
 APPLICABLE TO               ENVIRONMENTAL CONDITIONS                     INPUT POWER                        TESTED BY
        RE1G                     25deg. C, 65%RH                          120Vac, 60Hz                    Steven Chiang
        RE<1G                     25deg. C, 65%RH                          120Vac, 60Hz                    Steven Chiang
         PLC                      24deg. C, 73%RH                          120Vac, 60Hz                       Andy Ho




Report No.: RF180718D12-1                              Page No. 8 / 28                                   Report Format Version: 6.1.1


3.3      Description of Support Units

The EUT has been tested as an independent unit together with other necessary accessories or support units.
The following support units or accessories were used to form a representative test configuration during the
tests.
 ID          Product             Brand           Model No.             Serial No.             FCC ID             Remarks
 A.           Laptop             DELL              E6420               B92T3R1               FCC DoC         Provided by Lab
Note:
1. All power cords of the above support units are non-shielded (1.8m).


                                                                      Shielding
 ID           Descriptions               Qty.         Length (m)                    Cores (Qty.)           Remarks
                                                                      (Yes/No)
 1.       USB To USB Cable                 1               1.5           Yes             0              Provided by Lab
Note: The core(s) is(are) originally attached to the cable(s).




Report No.: RF180718D12-1                                    Page No. 9 / 28                           Report Format Version: 6.1.1


3.3.1   Configuration of System under Test


For Conducted emission test:




For other test items:




Report No.: RF180718D12-1                Page No. 10 / 28   Report Format Version: 6.1.1


3.4   General Description of Applied Standards


The EUT is a RF Product. According to the specifications of the manufacturer, it must comply with the
requirements of the following standards:

FCC Part 15, Subpart C (15.249)
ANSI C63.10-2013


All test items have been performed and recorded as per the above standards.




Report No.: RF180718D12-1                     Page No. 11 / 28                       Report Format Version: 6.1.1


4       Test Types and Results
4.1     Radiated Emission and Bandedge Measurement
4.1.1    Limits of Radiated Emission and Bandedge Measurement


The field strength of emissions from intentional radiators operated within these frequency bands shall comply
with the following

             Fundamental                  Field Strength of Fundamental       Field Strength of Harmonics
              Frequency                          (millivolts/meter)                (microvolts/meter)

           902 ~ 928 MHz                                 50                                500
         2400 ~ 2483.5 MHz                               50                                500
          5725 ~ 5875 MHz                                50                                500
           24 ~ 24.25 GHz                               250                               2500


Emissions radiated outside of the specified frequency bands, except for harmonics, shall be attenuated by
at least 50 dB below the level of the fundamental or to the general radiated emission limits as below table,
whichever is the lesser attenuation

             Frequencies                           Field Strength              Measurement Distance
                (MHz)                            (microvolts/meter)                  (meters)

            0.009 ~ 0.490                           2400/F(kHz)                           300

            0.490 ~ 1.705                          24000/F(kHz)                            30
             1.705 ~ 30.0                                30                                30
                30 ~ 88                                 100                                 3
               88 ~ 216                                 150                                 3
              216 ~ 960                                 200                                 3
              Above 960                                 500                                 3
NOTE:
1.      The lower limit shall apply at the transition frequencies.
2.      Emission level (dBuV/m) = 20 log Emission level (uV/m).
3.      For frequencies above 1000MHz, the field strength limits are based on average detector, however, the
        peak field strength of any emission shall not exceed the maximum permitted average limits, specified
        above by more than 20dB under any condition of modulation.




Report No.: RF180718D12-1                        Page No. 12 / 28                      Report Format Version: 6.1.1


4.1.2 Test Instruments
For below 1GHz test:
DESCRIPTION &                                                                 CALIBRATED        CALIBRATED
                                  MODEL NO.                   SERIAL NO.
 MANUFACTURER                                                                 DATE               UNTIL
 Test Receiver
                                    N9038A                    MY54450088      July 05, 2018      July 04, 2019
 Keysight
 Pre-Amplifier
                                     EMC001340                 980142         Feb. 09, 2018 Feb. 08, 2019
 EMCI
                (*)
 Loop Antenna
                                     EM-6879                   264            Dec. 16, 2016 Dec. 15, 2018
 Electro-Metrics
 RF Cable                            NA                        LOOPCAB-001    Jan. 15, 2018      Jan. 14, 2019
 RF Cable                            NA                        LOOPCAB-002    Jan. 15, 2018      Jan. 14, 2019
 Pre-Amplifier
                                    ZFL-1000VH2B              AMP-ZFL-01      Nov. 09, 2017 Nov. 08, 2018
 Mini-Circuits
 Trilog Broadband Antenna
                                     VULB 9168                 9168-406       Nov. 29, 2017 Nov. 28, 2018
 SCHWARZBECK
 RF Cable                            8D                        966-4-1        Mar. 21, 2018 Mar. 20, 2019
 RF Cable                            8D                        966-4-2        Mar. 21, 2018 Mar. 20, 2019
 RF Cable                            8D                        966-4-3        Mar. 21, 2018 Mar. 20, 2019
 Fixed attenuator
                                     UNAT-5+                   PAD-3m-4-01    Oct. 03, 2017      Oct. 02, 2018
 Mini-Circuits
 Software                            ADT_Radiated_V8.7.08 NA                  NA                 NA
Note:
1. The calibration interval of the above test instruments is 12 months and the calibrations are
   traceable to NML/ROC and NIST/USA.
2. *The calibration interval of the above test instruments is 24 months and the calibrations are
   traceable to NML/ROC and NIST/USA.
3. The test was performed in 966 Chamber No. 4.
4. The CANADA Site Registration No. is 20331-2
5. Loop antenna was used for all emissions below 30 MHz.
6. Tested Date: Sep. 07, 2018




Report No.: RF180718D12-1                      Page No. 13 / 28                        Report Format Version: 6.1.1


For above 1GHz test:
DESCRIPTION &                                                                 CALIBRATED          CALIBRATED
                                  MODEL NO.                   SERIAL NO.
 MANUFACTURER                                                                 DATE                UNTIL
 Test Receiver
                                    N9038A                    MY54450088      July 05, 2018       July 04, 2019
 Keysight
 Horn_Antenna
                                    BBHA 9120D                9120D-783       Dec. 12, 2017       Dec. 11, 2018
 SCHWARZBECK
 Pre-Amplifier
                                    ZVA-183-S+                AMP-ZVA-03      May 10, 2018        May 09, 2019
 Mini-Circuits
 RF Cable                           EMC104-SM-SM-1200 160923                  Jan. 29, 2018       Jan. 28, 2019
 RF Cable                           EMC104-SM-SM-2000 150318                  Jan. 29, 2018       Jan. 28, 2019
 RF Cable                           EMC104-SM-SM-5000 150321                  Jan. 29, 2018       Jan. 28, 2019
 Pre-Amplifier
                                    EMC184045SE               980387          Jan. 29, 2018       Jan. 28, 2019
 EMCI
 Horn_Antenna
                                    BBHA 9170                 BBHA9170608 Dec. 14, 2017           Dec. 13, 2018
 SCHWARZBECK
 RF Cable                           EMC102-KM-KM-1200 160925                  Jan. 29, 2018       Jan. 28, 2019
 Software                           ADT_Radiated_V8.7.08 NA                   NA                  NA
 Boresight Antenna Tower &
 Turn Table                         MF-7802BS                 MF780208530 NA                      NA
 Max-Full
Note:
1. The calibration interval of the above test instruments is 12 months and the calibrations are
   traceable to NML/ROC and NIST/USA.
2. The test was performed in 966 Chamber No. 4.
3. The CANADA Site Registration No. is 20331-2
4. Loop antenna was used for all emissions below 30 MHz.
5. Tested Date: Oct. 17, 2018




Report No.: RF180718D12-1                      Page No. 14 / 28                         Report Format Version: 6.1.1


4.1.3 Test Procedures
For Radiated emission below 30MHz
 a. The EUT was placed on the top of a rotating table 0.8 meters above the ground at a 3 meter chamber
        room. The table was rotated 360 degrees to determine the position of the highest radiation.

     b. The EUT was set 3 meters away from the interference-receiving antenna, which was mounted on the top
        of a variable-height antenna tower.

     c. Parallel, perpendicular, and ground-parallel orientations of the antenna are set to make the
        measurement.

     d. For each suspected emission, the EUT was arranged to its worst case and the rotatable table was turned
        from 0 degrees to 360 degrees to find the maximum reading.

     e. The test-receiver system was set to Quasi-Peak Detect Function and Specified Bandwidth with
        Maximum Hold Mode.
NOTE:
     1. The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is 9kHz at frequency
        below 30MHz.

For Radiated emission above 30MHz
a. The EUT was placed on the top of a rotating table 0.8 meters (for 30MHz ~ 1GHz) / 1.5 meters (for above
    1GHz) above the ground at 3 meter chamber room for test. The table was rotated 360 degrees to
    determine the position of the highest radiation.
b.      The EUT was set 3 meters away from the interference-receiving antenna, which was mounted on the top
        of a variable-height antenna tower.
c.      The height of antenna is varied from one meter to four meters above the ground to determine the
        maximum value of the field strength. Both horizontal and vertical polarizations of the antenna are set to
        make the measurement.
d.      For each suspected emission, the EUT was arranged to its worst case and then the antenna was tuned
        to heights from 1 meter to 4 meters and the rotatable table was turned from 0 degrees to 360 degrees to
        find the maximum reading.
e.      The test-receiver system was set to quasi-peak detect function and specified bandwidth with maximum
        hold mode when the test frequency is below 1 GHz.
f.      The test-receiver system was set to peak and average detect function and specified bandwidth with
        maximum hold mode when the test frequency is above 1 GHz. If the peak reading value also meets
        average limit, measurement with the average detector is unnecessary.


Note:
1. The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is 120kHz for
    Quasi-peak detection (QP) at frequency below 1GHz.
2.      The resolution bandwidth of test receiver/spectrum analyzer is 1 MHz and the video bandwidth is 3 MHz
        for Peak detection (PK) at frequency above 1GHz.
3.      The resolution bandwidth of test receiver/spectrum analyzer is 1 MHz and the video bandwidth is 3 MHz
        for Average detection (AV) at frequency above 1GHz.
4.      All modes of operation were investigated and the worst-case emissions are reported.


4.1.4      Deviation from Test Standard

     No deviation.


Report No.: RF180718D12-1                         Page No. 15 / 28                        Report Format Version: 6.1.1


4.1.5   Test Setup

 For Radiated emission below 30MHz


                                                                    1m
            EUT&                       3m
            Support Units

                              Turn Table

               80cm


                                     Ground Plane
                                     Test Receiver




 For Radiated emission 30MHz to 1GHz

                                                       Ant. Tower
                                                                     1-4m
                                                                     Variable
                                           3m
                                            10m
              EUT&
              Support Units

                                  Turn Table

                  80cm


                                       Ground Plane

                                       Test Receiver




Report No.: RF180718D12-1               Page No. 16 / 28                 Report Format Version: 6.1.1


 For Radiated emission above 1GHz



                                                                   Ant. Tower         1-4m
                                                                                      Variable
               EUT&                              3m
               Support Units

                                       Turn Table
                                                       Absorber

                  150cm


                                              Ground Plane
                                              Test Receiver




 For the actual test configuration, please refer to the attached file (Test Setup Photo).




4.1.6   EUT Operating Conditions

Controlling software (Console Port use”Test command”) has been activated to set the EUT on specific status.




Report No.: RF180718D12-1                       Page No. 17 / 28                            Report Format Version: 6.1.1


                                                                                                                     Eooert
                                                                                                                      venitas




4.1.7    Test Results
Above 1GHz Data :

CHANNEL                       TX Channel 15                      DETECTOR               Peak (PK)

FREQUENCY RANGE |1GHz ~ 25GHz                                    FUNCTION               Average (AV)

                      ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M
                       EMISSION                                    ANTENNA   TABLE         RAW          CORRECTION
NO.      I(:':E'(:)     LEVEL     (d;llljllvl;rm)   MI(\:BG)IN     HEIGHT     ANGLE       VALUE            FACTOR
                       (dBuV/m)                                      (m)     (Degree)     (dBuV)            (dB/m)
  1      2369.00        57.7 PK       74.0            16.3          1.00 H     285          59.8             —2.1
 2       2369.00        49.8 AV       54.0            4.2           1.00 H     285          51.9             —2.1
 3       2390.00        56.8 PK       74.0            17.2          1.00 H     285          59.0             2.2
 4       2390.00        44.6 AV       54.0            —9.4          1.00 H     285          46.8             —2.2
 5      *2415.00        91.5 PK      114.0            —22.5         1.00 H     285          93.9             —2.4
 6      *2415.00        70.9 AV       94.0            —283.1        1.00 H     285          73.3             —2.4
 7       4830.00        46.2 PK       74.0            —27.8         1.63 H     219          44.4             1.8
 8       4830.00        35.6 AV       54.0            —18.4         1.63 H     219          33.8             1.8
 9       7245.00        49.3 PK       74.0            24.7          2.23 H     258          41.3             8.0
 10      7245.00        38.6 AV       54.0            15.4          2.23 H     258          30.6             8.0
                       ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M
                       EMISSION                                    ANTENNA   TABLE         RAW          CORRECTION
NO.      I(:':E'(:)     LEVEL     (d;llljllvl;rm)   MI(\:BG)IN     HEIGHT     ANGLE       VALUE            FACTOR
                       (dBuV/m)                                      (m)     (Degree)     (dBuV)            (dB/m)
  1      2369.00        56.8 PK       74.0            17.2          1.25 V     315          58.9             —2.1
 2       2369.00        48.8 AV       54.0            5.2           1.25 V     315          50.9             —2.1
 3       2390.00        56.1 PK       74.0            —17.9         1.25 V     315          58.3             —2.2
 4       2390.00        44.1 AV       54.0            —9.9          1.25 V     315          46.3             2.2
 5      *2415.00        89.0 PK      114.0            25.0          1.25 V     315          91.4             —2.4
 6      *2415.00        68.1 AV       94.0            25.9          1.25 V     315          70.5             —2.4
 7       4830.00        45.9 PK       74.0            —28.1         1.91 V     106          44.1             1.8
 8       4830.00        35.3 AV       54.0            —18.7         1.91 V     106          33.5             1.8
 9       7245.00        48.5 PK       74.0            —25.5         1.89 V     206          40.5             8.0
 10      7245.00        37.4 AV       54.0            —16.6         1.89 V     206          29.4             8.0
REMARKS:
      1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
      2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) — Pre—Amplifier Factor(dB)
      3. The other emission levels were very low against the limit.
      4. Margin value = Emission Level — Limit value
      5. " * ": Fundamental frequency.




Report No.: RF180718D12—1                              Page No. 18 / 28                            Report Format Version: 6.1.1


CHANNEL                     TX Channel 39            DETECTOR                 Peak (PK)
FREQUENCY RANGE             1GHz ~ 25GHz             FUNCTION                 Average (AV)


                  ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M
                   EMISSION                             ANTENNA     TABLE        RAW          CORRECTION
        FREQ.                     LIMIT     MARGIN
NO.                 LEVEL                                HEIGHT     ANGLE       VALUE           FACTOR
        (MHz)                   (dBuV/m)     (dB)
                   (dBuV/m)                                (m)     (Degree)     (dBuV)           (dB/m)
  1     2311.00      58.1 PK     74.0        -15.9        1.00 H     291          60.1             -2.0
  2     2311.00      51.0 AV     54.0         -3.0        1.00 H     291          53.0             -2.0
  3     2400.00      54.8 PK     74.0        -19.2        1.00 H     291          57.0             -2.2
  4     2400.00      44.5 AV     54.0         -9.5        1.00 H     291          46.7             -2.2
  5    *2439.00      92.0 PK     114.0       -22.0        1.00 H     291          94.6             -2.6
  6    *2439.00      71.1 AV     94.0        -22.9        1.00 H     291          73.7             -2.6
  7     2483.50      55.6 PK     74.0        -18.4        1.00 H     291          58.0             -2.4
  8     2483.50      44.6 AV     54.0         -9.4        1.00 H     291          47.0             -2.4
  9     2484.00      58.4 PK     74.0        -15.6        1.00 H     291          60.8             -2.4
 10     2484.00      49.4 AV     54.0         -4.6        1.00 H     291          51.8             -2.4
 11     4878.00      46.4 PK     74.0        -27.6        1.67 H     230          44.4              2.0
 12     4878.00      35.9 AV     54.0        -18.1        1.67 H     230          33.9              2.0
 13     7317.00      50.0 PK     74.0        -24.0        1.83 H     260          41.6              8.4
 14     7317.00      39.4 AV     54.0        -14.6        1.83 H     260          31.0              8.4
                    ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M
                   EMISSION                             ANTENNA     TABLE        RAW          CORRECTION
        FREQ.                     LIMIT     MARGIN
NO.                 LEVEL                                HEIGHT     ANGLE       VALUE           FACTOR
        (MHz)                   (dBuV/m)     (dB)
                   (dBuV/m)                                (m)     (Degree)     (dBuV)           (dB/m)
  1     2311.00      58.7 PK     74.0        -15.3        1.33 V     334          60.7             -2.0
  2     2311.00      51.2 AV     54.0         -2.8        1.33 V     334          53.2             -2.0
  3     2400.00      55.3 PK     74.0        -18.7        1.33 V     334          57.5             -2.2
  4     2400.00      44.5 AV     54.0         -9.5        1.33 V     334          46.7             -2.2
  5    *2439.00      88.7 PK     114.0       -25.3        1.33 V     334          91.3             -2.6
  6    *2439.00      67.8 AV     94.0        -26.2        1.33 V     334          70.4             -2.6
  7     2483.50      55.2 PK     74.0        -18.8        1.33 V     334          57.6             -2.4
  8     2483.50      44.5 AV     54.0         -9.5        1.33 V     334          46.9             -2.4
  9     2484.00      56.6 PK     74.0        -17.4        1.33 V     334          59.0             -2.4
 10     2484.00      48.7 AV     54.0         -5.3        1.33 V     334          51.1             -2.4
 11     4878.00      45.4 PK     74.0        -28.6        1.83 V     111          43.4              2.0
 12     4878.00      34.2 AV     54.0        -19.8        1.83 V     111          32.2              2.0
 13     7317.00      49.3 PK     74.0        -24.7        1.51 V     312          40.9              8.4
 14     7317.00      38.7 AV     54.0        -15.3        1.51 V     312          30.3              8.4
REMARKS:
   1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
   2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
   3. The other emission levels were very low against the limit.
   4. Margin value = Emission Level – Limit value
   5. " * ": Fundamental frequency.




Report No.: RF180718D12-1                     Page No. 19 / 28                           Report Format Version: 6.1.1


CHANNEL                     TX Channel 59            DETECTOR                 Peak (PK)
FREQUENCY RANGE             1GHz ~ 25GHz             FUNCTION                 Average (AV)


                  ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M
                   EMISSION                             ANTENNA     TABLE        RAW          CORRECTION
        FREQ.                     LIMIT     MARGIN
NO.                 LEVEL                                HEIGHT     ANGLE       VALUE           FACTOR
        (MHz)                   (dBuV/m)     (dB)
                   (dBuV/m)                                (m)     (Degree)     (dBuV)           (dB/m)
  1     2349.00      57.8 PK     74.0        -16.2        1.01 H     289          59.7             -1.9
  2     2349.00      51.2 AV     54.0         -2.8        1.01 H     289          53.1             -1.9
  3     2400.00      56.1 PK     74.0        -17.9        1.01 H     289          58.3             -2.2
  4     2400.00      44.8 AV     54.0         -9.2        1.01 H     289          47.0             -2.2
  5    *2459.00      91.0 PK     114.0       -23.0        1.01 H     289          93.6             -2.6
  6    *2459.00      70.2 AV     94.0        -23.8        1.01 H     289          72.8             -2.6
  7     2483.50      57.1 PK     74.0        -16.9        1.01 H     289          59.5             -2.4
  8     2483.50      43.9 AV     54.0        -10.1        1.01 H     289          46.3             -2.4
  9     4918.00      46.4 PK     74.0        -27.6        1.64 H     222          44.4              2.0
 10     4918.00      35.3 AV     54.0        -18.7        1.64 H     222          33.3              2.0
 11     7377.00      50.7 PK     74.0        -23.3        1.87 H     258          42.1              8.6
 12     7377.00      39.7 AV     54.0        -14.3        1.87 H     258          31.1              8.6
                    ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M
                   EMISSION                             ANTENNA     TABLE        RAW          CORRECTION
        FREQ.                     LIMIT     MARGIN
NO.                 LEVEL                                HEIGHT     ANGLE       VALUE           FACTOR
        (MHz)                   (dBuV/m)     (dB)
                   (dBuV/m)                                (m)     (Degree)     (dBuV)           (dB/m)
  1     2349.00      57.1 PK     74.0        -16.9        1.27 V     326          59.0             -1.9
  2     2349.00      50.3 AV     54.0         -3.7        1.27 V     326          52.2             -1.9
  3     2400.00      55.4 PK     74.0        -18.6        1.27 V     326          57.6             -2.2
  4     2400.00      44.2 AV     54.0         -9.8        1.27 V     326          46.4             -2.2
  5    *2459.00      89.2 PK     114.0       -24.8        1.27 V     326          91.8             -2.6
  6    *2459.00      68.5 AV     94.0        -25.5        1.27 V     326          71.1             -2.6
  7     2483.50      55.7 PK     74.0        -18.3        1.27 V     326          58.1             -2.4
  8     2483.50      43.6 AV     54.0        -10.4        1.27 V     326          46.0             -2.4
  9     4918.00      45.7 PK     74.0        -28.3        1.88 V     112          43.7              2.0
 10     4918.00      34.8 AV     54.0        -19.2        1.88 V     112          32.8              2.0
 11     7377.00      49.8 PK     74.0        -24.2        1.52 V     306          41.2              8.6
 12     7377.00      39.3 AV     54.0        -14.7        1.52 V     306          30.7              8.6
REMARKS:
   1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
   2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
   3. The other emission levels were very low against the limit.
   4. Margin value = Emission Level – Limit value
   5. " * ": Fundamental frequency.




Report No.: RF180718D12-1                     Page No. 20 / 28                           Report Format Version: 6.1.1


Below 1GHz Data:
CHANNEL                     TX Channel 59            DETECTOR
                                                                              Quasi-Peak (QP)
FREQUENCY RANGE             9kHz ~ 1GHz              FUNCTION


                  ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M
                   EMISSION                             ANTENNA     TABLE        RAW         CORRECTION
        FREQ.                     LIMIT     MARGIN
NO.                 LEVEL                                HEIGHT     ANGLE       VALUE          FACTOR
        (MHz)                   (dBuV/m)     (dB)
                   (dBuV/m)                                (m)     (Degree)     (dBuV)          (dB/m)
  1      31.02       26.4 QP      40.0       -13.6        1.00 H     242         35.4             -9.0
  2     153.99       19.9 QP      43.5       -23.6        1.00 H     160         27.6             -7.7
  3     519.15       27.3 QP      46.0       -18.7        1.50 H      0          28.6             -1.3
  4     695.69       30.1 QP      46.0       -15.9        1.50 H     116         28.2              1.9
  5     843.08       32.3 QP      46.0       -13.7        1.50 H     42          27.8              4.5
  6     937.29       34.0 QP      46.0       -12.0        1.00 H     307         27.9              6.1
REMARKS:
   1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
   2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
   3. Margin value = Emission Level – Limit value
   4. The emission levels were very low against the limit of frequency range 9kHz~30MHz: the amplitude of
      spurious emissions attenuated more than 20 dB below the permissible value to be report.




Report No.: RF180718D12-1                     Page No. 21 / 28                          Report Format Version: 6.1.1


CHANNEL                     TX Channel 59            DETECTOR
                                                                              Quasi-Peak (QP)
FREQUENCY RANGE             9kHz ~ 1GHz              FUNCTION


                    ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M
                   EMISSION                             ANTENNA     TABLE        RAW         CORRECTION
        FREQ.                     LIMIT     MARGIN
NO.                 LEVEL                                HEIGHT     ANGLE       VALUE          FACTOR
        (MHz)                   (dBuV/m)     (dB)
                   (dBuV/m)                                (m)     (Degree)     (dBuV)          (dB/m)
  1      30.68       27.3 QP      40.0       -12.7        1.50 V     360         36.2             -8.9
  2     160.44       20.3 QP      43.5       -23.2        2.00 V     286         28.0             -7.7
  3     429.76       24.7 QP      46.0       -21.3        2.00 V     150         27.9             -3.2
  4     549.07       27.1 QP      46.0       -18.9        1.00 V     253         27.9             -0.8
  5     766.33       31.3 QP      46.0       -14.7        2.00 V     120         27.9              3.4
  6     932.61       33.7 QP      46.0       -12.3        1.00 V     125         27.7              6.0
REMARKS:
   1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
   2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
   3. Margin value = Emission Level – Limit value
   4. The emission levels were very low against the limit of frequency range 9kHz~30MHz: the amplitude of
      spurious emissions attenuated more than 20 dB below the permissible value to be report.




Report No.: RF180718D12-1                     Page No. 22 / 28                          Report Format Version: 6.1.1


4.2     Conducted Emission Measurement
4.2.1    Limits of Conducted Emission Measurement

                                                            Conducted Limit (dBuV)
        Frequency (MHz)
                                               Quasi-peak                               Average
          0.15 - 0.5                             66 - 56                                 56 - 46
          0.50 - 5.0                               56                                       46
          5.0 - 30.0                               60                                       50
  Note: 1. The lower limit shall apply at the transition frequencies.
        2. The limit decreases in line with the logarithm of the frequency in the range of 0.15 to 0.50MHz.


4.2.2 Test Instruments
DESCRIPTION &                                                         CALIBRATED            CALIBRATED
                             MODEL NO.           SERIAL NO.
 MANUFACTURER                                                         DATE                  UNTIL
Test Receiver
                             ESCS 30             847124/029           Nov. 01, 2017        Oct. 31, 2018
R&S
Line-Impedance
Stabilization Network (for
                             ESH3-Z5             848773/004           Nov. 15, 2017        Nov. 14, 2018
EUT)
R&S
Line-Impedance
Stabilization Network
                             ENV216              100072               June 04, 2018        June 03, 2019
(for Peripheral)
R&S
50 ohms Terminator           N/A                 EMC-04               Nov. 01, 2017        Oct. 31, 2018
RF Cable                     5D-FB               COCCAB-001           Sep. 29, 2017        Sep. 28, 2018
Fixed attenuator
                             STI02-2200-10       003                  Mar. 16, 2018        Mar. 15, 2019
EMCI
Software                     BVADT_Cond_
                                                 NA                   NA                   NA
BVADT                        V7.3.7.4

Note:
 1. The calibration interval of the above test instruments are 12 months and the calibrations are
    traceable to NML/ROC and NIST/USA.
 2. The test was performed in Conduction 1.
 3. Tested Date: Aug. 05, 2018




Report No.: RF180718D12-1                      Page No. 23 / 28                        Report Format Version: 6.1.1


                                                                                                                 uces
                                                                                                                 venitas



4.2.3     Test Procedures
  a.    The EUT was placed 0.4 meters from the conducting wall of the shielded room with EUT being
        connected to the power mains through a line impedance stabilization network (LISN). Other support
        units were connected to the power mains through another LISN. The two LISNs provide 50 ohm/ 50uH
        of coupling impedance for the measuring instrument.
  b.    Both lines of the power mains connected to the EUT were checked for maximum conducted
        interference.
  c.    The frequency range from 150kHz to 30MHz was searched. Emission levels under (Limit — 200B) was
        not recorded.

 NOTE: The resolution bandwidth and video bandwidth of test receiver is 9kHz for quasi—peak detection (QP)
       and average detection (AV) at frequency 0.15MHz—30MHz.


4.2.4     Deviation from Test Standard

 No deviation.


4.2.5     Test Setup
                                        Vertical Ground
                                        Reference Plane                            / Test Receiver

                        ~at——ie~                                                         L___J
                                                                                      c o o o
                         40cm           EUT                                        E* 5 o o 0




                                                             80cm
                         LISN
                                   L1               L1                             L
                                                             \           N
                                                                        Horizont
                                                                                                  T
                                                                                 al Ground
                                                                        Refere         Plane
                                                                               nce

                          Note: 1.Support units were connected to second LISN.




 For the actual test configuration, please refer to the attached file (Test Setup Photo).


4.2.6     EUT Operating Conditions

Same as 4.1.6.




Report No.: RF180718D12—1                            Page No. 24 / 28                          Report Format Version: 6.1.1


4.2.7   Test Results
                                                                                   Quasi-Peak (QP) /
Phase                        Line (L)                       Detector Function
                                                                                   Average (AV)

                         Corr.    Reading Value       Emission Level           Limit               Margin
           Freq.
 No                     Factor       [dB (uV)]           [dB (uV)]          [dB (uV)]               (dB)
          [MHz]          (dB)      Q.P.     AV.        Q.P.     AV.       Q.P.       AV.       Q.P.        AV.
  1      0.15000        10.03     29.25    15.53      39.28    25.56     66.00     56.00      -26.72     -30.44
  2      0.18125        10.05     32.22     8.67      42.27    18.72     64.43     54.43      -22.16     -35.71
  3      0.81797        10.14     23.61     6.75      33.75    16.89     56.00     46.00      -22.25     -29.11
  4      1.92578        10.19     23.11    11.72      33.30    21.91     56.00     46.00      -22.70     -24.09
  5      2.94141        10.23     24.69    14.27      34.92    24.50     56.00     46.00      -21.08     -21.50
  6     10.50000        10.57     18.54    11.88      29.11    22.45     60.00     50.00      -30.89     -27.55

REMARKS:
               1. Q.P. and AV. are abbreviations of quasi-peak and average individually.
               2. The emission levels of other frequencies were very low against the limit.
               3. Margin value = Emission level - Limit value
               4. Correction factor = Insertion loss + Cable loss
               5. Emission Level = Correction Factor + Reading Value.




Report No.: RF180718D12-1                      Page No. 25 / 28                         Report Format Version: 6.1.1


                                                                                   Quasi-Peak (QP) /
Phase                        Neutral (N)                    Detector Function
                                                                                   Average (AV)

                         Corr.    Reading Value       Emission Level           Limit               Margin
           Freq.
 No                     Factor       [dB (uV)]           [dB (uV)]          [dB (uV)]               (dB)
         [MHz]           (dB)      Q.P.     AV.        Q.P.     AV.       Q.P.       AV.       Q.P.        AV.
  1     0.15000          9.94     40.44    16.46      50.38    26.40     66.00     56.00      -15.62     -29.60
  2     0.17734          9.95     36.37    18.31      46.32    28.26     64.61     54.61      -18.29     -26.35
  3     0.38828         10.00     17.24     2.65      27.24    12.65     58.10     48.10      -30.86     -35.45
  4     0.90391         10.03     20.43     6.93      30.46    16.96     56.00     46.00      -25.54     -29.04
  5     3.19141         10.11     24.44    14.47      34.55    24.58     56.00     46.00      -21.45     -21.42
  6     11.51953        10.47     18.39    11.06      28.86    21.53     60.00     50.00      -31.14     -28.47

REMARKS:
               1. Q.P. and AV. are abbreviations of quasi-peak and average individually.
               2. The emission levels of other frequencies were very low against the limit.
               3. Margin value = Emission level - Limit value
               4. Correction factor = Insertion loss + Cable loss
               5. Emission Level = Correction Factor + Reading Value.




Report No.: RF180718D12-1                      Page No. 26 / 28                         Report Format Version: 6.1.1


5    Pictures of Test Arrangements


 Please refer to the attached file (Test Setup Photo).




Report No.: RF180718D12-1                      Page No. 27 / 28   Report Format Version: 6.1.1


Appendix – Information on the Testing Laboratories


We, Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch, were founded in 1988 to
provide our best service in EMC, Radio, Telecom and Safety consultation. Our laboratories are FCC
recognized accredited test firms and accredited according to ISO/IEC 17025.

If you have any comments, please feel free to contact us at the following:

Linkou EMC/RF Lab                                     Hsin Chu EMC/RF/Telecom Lab
Tel: 886-2-26052180                                   Tel: 886-3-6668565
Fax: 886-2-26051924                                   Fax: 886-3-6668323


Hwa Ya EMC/RF/Safety Lab
Tel: 886-3-3183232
Fax: 886-3-3270892


Email: service.adt@tw.bureauveritas.com
Web Site: www.bureauveritas-adt.com

The address and road map of all our labs can be found in our web site also.



--- END ---




Report No.: RF180718D12-1                     Page No. 28 / 28                  Report Format Version: 6.1.1



Document Created: 2018-11-05 18:17:21
Document Modified: 2018-11-05 18:17:21

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC