Users manual

FCC ID: PPQ-IMP002

Users Manual

Download: PDF
FCCID_1923324

specification: imp002
version 20130221




                        http://www.electricimp.com


electric imp, inc



1. Product description
1.1 General description
The imp is a complete wireless network node in a module. It is available both in a memory card form-factor (imp001) and
in a solder-down module form-factor (imp002). It works in conjunction with the imp service to allow easy connection of
any device to the internet.

1.2 Features
• 802.11 b/g/n WiFi
     • 20MHz 11n channels, 1 x 1
     • +16.75dBm max output power (802.11b)
     • -97dBm typical sensitivity (1Mbps)
     • Integrated antenna with 2.5dBi max gain
     • TX power
          • 802.11b 16.5dBm +/-1.5dBm
          • 802.11g 14.0dBm +/-1.5dBm
         • 802.11n 12.75dBm +/-1.5dBm
• 32-bit Cortex M3 processor
    • Robust embedded operating system with fail-safe firmware updates
    • Virtual machine for vendor firmware
• LED drive for red/green status LEDs
• Phototransistor input for our patent-pending BlinkUp technology to provide optical configuration
• 12 user selectable I/Os
    • GPIO, PWM, Analog input & output
    • SPI (2 channels), UART (4.5 channels), I2C (2 channels)
• Low power 6uA sleep mode
• FCC, CE, IC C-Tick certified




electric imp imp002 specification (confidential, not for distribution)                                                   2


electric imp, inc




2. imp terminology


        Term                                                        Description
                        The Application Programming Interface through which imp scripts may access hardware and
          API
                        cloud functions
                        Our patent-pending optical programming process for commissioning an imp using a smart
       BlinkUp
                        device (phone or tablet)
   Commissioning        Initializing an imp by associating it with a user account and WiFi credentials, usually via BlinkUp
     electric imp       http://electricimp.com/aboutus/ (lower case by brand convention)
                        The imp cloud service which provides for the connection and configuration of imps and gateway
       Planner
                        communication with other devices
     Registration       The process by which an imp card or module becomes associated with host hardware
        Server          The electric imp cloud service with which imps communicate
      Firmware          Vendor provided code that runs within the imp’s virtual machine
        Agent           Vendor provided code that runs within the imp service




electric imp imp002 specification (confidential, not for distribution)                                                        3


electric imp, inc



3. Pin assignments




4. Pin description


   Pin number           Pin name                                            Description
  1, 7, 13, 17, 23
                       GND1 to 15      Ground
    to 32 & 35
      18, 33               VDD         Power input
         2             OPTO_BIAS       Phototransistor power; connects to collector of phototransistor
                                       Phototransistor signal; connects to emitter of phototransistor, which is connected
         6              OPTO_IN
                                       to ground via a bias resistor (typically 100k)
         3            LED_GREEN        Green LED open-drain output (connect to cathode of LED)
         4              LED_RED        Red LED open-drain output (connect to cathode of LED)
                                       Active-high output for boost DCDC enable. Is driven high when the module
         5             POWER_EN        requires a 2.5-3.3v power supply, which is generally when WiFi is active. This pin
                                       has an internal pulldown.
         34                VREF        ADC reference voltage input. If unused, connect to VDD




electric imp imp002 specification (confidential, not for distribution)                                                      4


electric imp, inc



 8 to 12, 14 to 16
                        PIN1, 2, 5 to E I/O, please refer to Pin mux table
     & 19 to 22




5. Pin mux
In addition to acting as a GPIO, each pin on the imp002 can be configured to one of several specialized functions. While
pins may only have one function at a time, they may be reconfigured during run-time to change function as needed. For
example, a pin may first be configured as a DAC and then reconfigured as an ADC. Additionally, not all the pins in a
hardware function need to be assigned to that function. For example, pins 8 and 9 could be used as UART and pins 1
and 2 could be used as I2C.

All I/O pins are initially tri-stated.

The imp002 can be woken from low power sleep mode with a rising edge on PIN1. If this signal is pulsed, the minimum
pulse width is 20ms.


   Pin        GPIO              UART           I2C           SPI             DAC   ADC   PWM     Pulse Count      Wake
  PIN 1        Yes        U1-CTS, U3-TX      I1-SCL       SPI1-SCLK          Yes   Yes   Yes          Yes          Yes


  PIN 2        Yes        U1-RTS, U3-RX      I1-SDA       SPI2-MISO                Yes   Yes


  PIN 5        Yes              U2-TX                     SPI2-SCLK          Yes   Yes   Yes




electric imp imp002 specification (confidential, not for distribution)                                                     5


electric imp, inc



  PIN 6        Yes          U6-TX
  PIN 7        Yes          U2-RX                        SPI2-MOSI                 Yes   Yes
  PIN 8        Yes          U1-TX           I2-SCL       SPI1-MOSI                 Yes   Yes
  PIN 9        Yes          U1-RX           I2-SDA        SPI1-MSO                 Yes   Yes
  PIN A        Yes                                                                 Yes   Yes
  PIN B        Yes          U4-RX                                                  Yes   Yes
  PIN C        Yes                                                                       Yes
  PIN D        Yes          U1-RX
  PIN E        Yes          U6-RX




7. Electrical characteristics


          Parameter                            Condition                   Min           Typ   Max      Unit.
   Operating temperature                                                   -20                  55       ℃
      Operating voltage                                                   1.8[1]         3.0    3.6      V
                                  WiFi is off, processor sleep, RTC on,
          Sleep current                                                                  6               µA
                                            nvram preserved
                                       Normal operation, WiFi on            70           80    400[2]   mA
      Operating current
                                       Power-save mode enabled              2            5     400[2]   mA
            Pin drive              Maximum current drive on I/O pins                             4      mA
               VIL                     I/O input low level voltage        VSS-0.3              0.3VDD    V
               VIH                     I/O input high level voltage       0.7VDD                3.6      V
       LED current sink                                                                          8      mA
                                               Pins 1 to 9                               20              pF
      Load capacitance
                                              Pins 10 to 14                              5               pF


electric imp imp002 specification (confidential, not for distribution)                                          6


electric imp, inc



  I/O input leakage current                  VSS ≦ VIN ≦ VDD                                       4          µA


[1] WiFi requires 2.5v minimum for operation, but user code can run at 1.8v. The POWER_EN pin is driven to enable an
external boost converter that will provide 2.5v+ during WiFi usage.

[2] 400mA current is during worst-case TX events. These are a maximum of ~4.8ms long (802.11b 1Mbps)




8. Package outline


                                                   PCB dimensions




electric imp imp002 specification (confidential, not for distribution)                                                 7


electric imp, inc




                                 (all dimensions are in mm unless otherwise specified)




                                           Overall module dimensions




electric imp imp002 specification (confidential, not for distribution)                   8


electric imp, inc




                                 (all dimensions are in mm unless otherwise specified)




electric imp imp002 specification (confidential, not for distribution)                   9


electric imp, inc



9. Recommended footprint



              COU2




                                         PAU201                                                                              PAU2035
                                         PAU202                                                                              PAU2034
                                         PAU203                                                                              PAU2033
                                         PAU204                                                                              PAU2032
                                         PAU205                                                                              PAU2031
                                         PAU206                                                                              PAU2030
                                         PAU207                                                                              PAU2029
                                         PAU208                                                                              PAU2028
                                         PAU209                                                                              PAU2027
                                         PAU2010                                                                             PAU2026
                                         PAU2011                                                                             PAU2025
                                         PAU2012                                                                             PAU2024
                                         PAU2013
                                                    PAU2014 PAU2015 PAU2016 PAU2017 PAU2018 PAU2019 PAU2020 PAU2021 PAU202   PAU2023




                                 (all dimensions are in mm unless otherwise specified)




electric imp imp002 specification (confidential, not for distribution)                                                                 10


electric imp, inc




FCC Caution: To assure continued compliance, (example - use only shielded interface cables when connecting to
computer or peripheral devices). Any changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate this equipment.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device
may not cause harmful interference, and (2) this device must accept any interference received, including interference that
may cause undesired operation.




       Version                                                  Change description
      20121217          updated mechanical drawings to reflect the smaller coax connector
      20130103          updated recommended footprint to have a cleaner look
      20130122          changed PIN 10 to 14 to PIN A to E
      20130218          added FCC caution statement
      20130219          added TX power in paragraph 1.2
      20310221          updated TX power values




electric imp imp002 specification (confidential, not for distribution)                                                  11


       FCC Warning



          Notice
          This device complies with Part 15 of the FCC Rules. Operation is subject to the
          following two conditions: (1) this device may not cause harmful interference and (2)
          this device must accept any interference received, including interference that may
          cause undesired operation.
          For P15B equipment
          This equipment has been tested and found to comply with the limits for a Class B
          digital device, pursuant to part 15 of the FCC rules. These limits are designed to
          provide reasonable protection against harmful interference in a residential installation.
          This equipment generates, uses and can radiate radio frequency energy and, if not
          installed and used in accordance with the instructions, may cause harmful interference
          to radio communications. However, there is no guarantee that interference will not
          occur in a particular installation. If this equipment does cause harmful interference to
          radio or television reception, which can be determined by turning the equipment off
          and on, the user is encouraged to try to correct the interference by one or more of the
          following measures:
          -Reorient or relocate the receiving antenna.
          -Increase the separation between the equipment and receiver.
          -Connect the equipment into an outlet on a circuit different from that to which the
          receiver is connected.
          -Consult the dealer or an experienced radio/TV technician for help.
           Information To Be Supplied to the End User by the OEM or Integrator
           The following regulatory and safety notices must be published in documentation supplied to
           the end user of the product or system incorporating an adapter in compliance with local
           regulations. Host system must be labeled with "Contains FCCID:PPQ-IMP002“, FCC ID
           displayed on label.

This device is to be used only for mobile and fixed application. In order to re-use the imp Module
FCC approvals the antenna(s) used for this transmitter must be installed to provide a separation
distance of at least 20 cm from all persons and must not be co-located or operating in conjunction
with any other antenna or transmitter. If antenna is installed with a separation distance of less than
20 cm from all persons or is co-located or operating in conjunction with any other antenna or transmitter
then additional FCC testing may be required. End-Users must be provided with transmitter operation
conditions for satisfying RF exposure compliance.

OEM integrators must ensure that the end user has no manual instructions to remove or install
the imp module. The EUT has two antenna types (External & PIFA antenna) that as below.
Antennas used for this OEM module must not exceed 2dBi gain for External Antenna, and 2.86dBi is
for PIFA one for mobile and fixed operating configurations.


  IC Warning
      Canada — Low-power license-exempt radio communication devices (RSS-210)
      a. Common information Operation is subject to the following two conditions:
      1. This device may not cause interference, and
      2. This device must accept any interference, including interference that may cause
      undesired operation of the device.
      b. Operation in 2.4 GHz band To prevent radio interference to the licensed service,
      this device is intended to be operated indoors and installation outdoors is subject to
      licensing.
      Canada - de faible puissance exempts de licence des appareils de communication
      radio (CNR-210)

        a. Informations communes
        Son fonctionnement est soumis aux deux conditions suivantes:
        1. Ce dispositif ne peut causer des interférences, et
        2. Ce dispositif doit accepter toute interférence, y compris les interférences qui
        peuvent causer un mauvais fonctionnement du dispositif.
        b. Le fonctionnement en bande de 2,4 GHz Pour prévenir les interférences
        radioélectriques aux services sous licence, cet appareil est destiné à être exploité à
        l'intérieur et à l'extérieur d'installation est soumise à licence.

       Information To Be Supplied to the End User by the OEM or Integrator
       Modular information form OEM
       Information to Be Supplied to the End User by the OEM or Integrator
       The following regulatory and safety notices must be published in documentation supplied to
       the end user of the product or system incorporating an adapter in compliance with local
       regulations.
       Host system must be labeled with "Contains IC: 4491A-IMP002 “
This device is to be used only for mobile and fixed application. In order to re-use the imp Module
IC approvals the antenna(s) used for this transmitter must be installed to provide a separation
distance of at least 20 cm from all persons and must not be co-located or operating in conjunction
with any other antenna or transmitter. If antenna is installed with a separation distance of less than
20 cm from all persons or is co-located or operating in conjunction with any other antenna or transmitter
then additional IC testing may be required. End-Users must be provided with transmitter operation
conditions for satisfying RF exposure compliance.
OEM integrators must ensure that the end user has no manual instructions to remove or install
the imp module. The EUT has two antenna types (External & PIFA antenna) that as below.
Antennas used for this OEM module must not exceed 2dBi gain for External Antenna, and 2.86dBi is
for PIFA one. Both are for mobile and fixed operating configurations.



Document Created: 2013-03-07 14:21:30
Document Modified: 2013-03-07 14:21:30

© 2025 FCC.report