Test Report_rev.pdf

FCC ID: PPQ-DIAL01

Test Report

Download: PDF
FCCID_4063011

                                                               FCC Test Report

                       Report No.: RF180718D12-2

                            FCC ID: PPQ-DIAL01

                       Test Model: DIAL01

                 Received Date: July 18, 2018

                         Test Date: Sep. 06 to Oct. 17, 2018

                     Issued Date: Oct. 26, 2018


                         Applicant: LITE-ON Technology Corp.

                          Address: Bldg. C, 90, Chien 1 Rd., Chung-Ho,New Taipei City,23585,Taiwan



                        Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch
                                   Hsin Chu Laboratory
                    Lab Address: E-2, No.1, Li Hsin 1st Road, Hsinchu Science Park, Hsinchu City 300,
                                 Taiwan R.O.C.
            Test Location: E-2, No.1, Li Hsin 1st Road, Hsinchu Science Park, Hsinchu City 300,
                           Taiwan R.O.C.
       FCC Registration /
                           723255 / TW2022
      Designation Number:




This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted
only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this
report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product
unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you
provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided,
however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific
mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification. The report
must not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies.

Report No.: RF180718D12-2                                            Page No. 1 / 23                                            Report Format Version: 6.1.1


                                                                   Table of Contents
Release Control Record .................................................................................................................................. 3
1         Certificate of Conformity ...................................................................................................................... 4
2         Summary of Test Results ..................................................................................................................... 5
    2.1      Measurement Uncertainty ................................................................................................................... 5
    2.2      Modification Record ............................................................................................................................ 5
3         General Information .............................................................................................................................. 6
    3.1      General Description of EUT ................................................................................................................ 6
    3.2      Description of Test Modes ................................................................................................................... 7
    3.2.1    Test Mode Applicability and Tested Channel Detail ............................................................................. 8
    3.3      Description of Support Units ............................................................................................................... 9
    3.3.1    Configuration of System under Test .................................................................................................... 9
    3.4      General Description of Applied Standards ........................................................................................ 10
4         Test Types and Results ....................................................................................................................... 11
    4.1      Radiated Emission and Bandedge Measurement .............................................................................. 11
    4.1.1    Limits of Radiated Emission and Bandedge Measurement ............................................................... 11
    4.1.2    Test Instruments ................................................................................................................................ 12
    4.1.3    Test Procedures ................................................................................................................................. 14
    4.1.4    Deviation from Test Standard ............................................................................................................ 14
    4.1.5    Test Setup .......................................................................................................................................... 15
    4.1.6    EUT Operating Conditions................................................................................................................. 16
    4.1.7    Test Results ....................................................................................................................................... 17
5         Pictures of Test Arrangements .......................................................................................................... 22
Appendix – Information on the Testing Laboratories ................................................................................ 23




Report No.: RF180718D12-2                                            Page No. 2 / 23                                             Report Format Version: 6.1.1


                                           Release Control Record


Issue No.              Description                                         Date Issued
RF180718D12-2          Original release.                                   Oct. 26, 2018




Report No.: RF180718D12-2                     Page No. 3 / 23       Report Format Version: 6.1.1


1    Certificate of Conformity


            Product: Norman Dial

              Brand:

        Test Model: DIAL01

    Sample Status: ENGINEERING SAMPLE

          Applicant: LITE-ON Technology Corp.

          Test Date: Sep. 06 to Oct. 17, 2018

         Standards: 47 CFR FCC Part 15, Subpart C (Section 15.249)
                        ANSI C63.10: 2013



The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd.,
Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data
evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts
of the measurements of the sample’s EMC characteristics under the conditions specified in this report.




      Prepared by :                                             ,   Date:       Oct. 26, 2018
                              Claire Kuan / Specialist




     Approved by :                                              ,   Date:       Oct. 26, 2018
                                 May Chen / Manager




Report No.: RF180718D12-2                     Page No. 4 / 23                        Report Format Version: 6.1.1


                                                                                                           Eooert
                                                                                                            venitas



2      Summary of Test Results


                               47 CFR FCC Part 15, Subpart C (SECTION 15.249)

        FCC
                                 Test Item                   Result                    Remarks
       Clause
       15.207        AC Power Conducted Emission                 NA     Power supply is DC 3V from battery
                   Radiated Emission Test
                   B    E     M
       15.209        .an.d dge Measurement                              Meet the requirement of limit.
                   Limit: 50dB less than the peak value                   Cl          .        me
        15.249     of fundamental frequency or meet          PASS       Minimum passing margin is
      15.249 (d)       u       faas q o Y         .                     —3.6dB at 2311.00MHz & 2331.00MHz.
                   radiated emission limit in section
                   15.209



2.1      Measurement Uncertainty

Where relevant, the following measurement uncertainty levels have been estimated for tests performed on
the EUT as specified in CISPR 16—4—2:



                    Measurement                                   Frequency             Expand(ESQl)Jr(]f? Py

            Radiated Emissions up to 1 GHz                   30MHz ~ 1GHz                       5.33 dB
                                                                 1GHz ~ 6GHz                    5.10 dB
           Radiated Emissions above 1 GHz                    6GHz ~ 18GHz                       4.85 dB
                                                             18GHz ~ 40GHz                      5.24 dB


2.2      Modification Record
There were no modifications required for compliance.




Report No.: RF180718D12—2                       Page No. 5/ 23                           Report Format Version: 6.1.1


3     General Information
3.1     General Description of EUT

 Product                      Norman Dial
 Brand
 Test Model                   DIAL01
 Status of EUT                ENGINEERING SAMPLE
 Power Supply Rating          3Vdc from lithium battery
 Modulation Type              GFSK
 Transfer Rate                1Mbps
 Operating Frequency          2415~2459MHz
 Number of Channel            3
 Antenna Type                 Refer to Note
 Antenna Connector            Refer to Note
 Accessory Device             NA
 Data Cable Supplied          NA
Note:
1. The antenna provided to the EUT, please refer to the following table:
                                     Antenna Gain         Frequency
     Brand            Model                                                Antenna Type    Connecter Type
                                         (dBi)           range(GHz)
    Unictron         AA055A               2.5             2.4-2.4835       Chip Antenna            NA
2. The above EUT information is declared by manufacturer and for more detailed features description,
   please refer to the manufacturer's specifications or user's manual.




Report No.: RF180718D12-2                     Page No. 6 / 23                       Report Format Version: 6.1.1


3.2   Description of Test Modes

3 channels are provided to this EUT:
          Channel                  Frequency                     Channel        Frequency
             15                    2415 MHz                        39           2439 MHz
             59                    2459 MHz




Report No.: RF180718D12-2                      Page No. 7 / 23             Report Format Version: 6.1.1


3.2.1     Test Mode Applicability and Tested Channel Detail

EUT CONFIGURE                         APPLICABLE TO
                                                                                               DESCRIPTION
     MODE
                         RE1G             RE<1G              PLC

          -                 √                 √                -                                      -

Where         RE1G: Radiated Emission above 1GHz & Bandedge Measurement             RE<1G: Radiated Emission below 1GHz
              PLC: Power Line Conducted Emission                                     APCM: Antenna Port Conducted Measurement

NOTE:     1. The EUT had been pre-tested on the positioned of each 3 axis. The worst case was found when positioned on X-plane for
             below 1GHz and Y-plane for above 1GHz.
NOTE:     2. No need to concern of Conducted Emission due to the EUT is powered by battery.


 Radiated Emission Test (Above 1GHz):

        Pre-Scan has been conducted to determine the worst-case mode from all possible combinations
        between available modulations, data rates and antenna ports (if EUT with antenna diversity
        architecture).
        Following channel(s) was (were) selected for the final test as listed below.
          AVAILABLE CHANNEL                             TESTED CHANNEL                               MODULATION TYPE
                 15 to 59                                    15, 39, 59                                       GFSK



 Radiated Emission Test (Below 1GHz):

        Pre-Scan has been conducted to determine the worst-case mode from all possible combinations
        between available modulations, data rates and antenna ports (if EUT with antenna diversity
        architecture).
        Following channel(s) was (were) selected for the final test as listed below.
          AVAILABLE CHANNEL                             TESTED CHANNEL                               MODULATION TYPE
                 15 to 59                                          15                                         GFSK




Test Condition:
 APPLICABLE TO              ENVIRONMENTAL CONDITIONS                      INPUT POWER                         TESTED BY
        RE1G                      25deg. C, 65%RH                            3Vdc                          Steven Chiang
        RE<1G                      25deg. C, 65%RH                            3Vdc                          Steven Chiang




Report No.: RF180718D12-2                               Page No. 8 / 23                                   Report Format Version: 6.1.1


                                                                                                              Eooert
                                                                                                               venitas



3.3      Description of Support Units


The EUT has been tested as an independent unit together with other necessary accessories or support units.
The following support units or accessories were used to form a representative test configuration during the
tests.
 ID          Product            Brand          Model No.             Serial No.   ECC ID             Remarks
 A.          Battery           Lithium          CR 2032                     NA      NA           Supplied by client
Note:
1. All power cords of the above support units are non—shielded (1.8m).




3.3.1     Configuration of System under Test




                                                                  EUT




                                                              (A) Battery*2




Report No.: RF180718D12—2                                  Page No. 9/ 23                  Report Format Version: 6.1.1


3.4   General Description of Applied Standards


The EUT is a RF Product. According to the specifications of the manufacturer, it must comply with the
requirements of the following standards:

FCC Part 15, Subpart C (15.249)
ANSI C63.10-2013


All test items have been performed and recorded as per the above standards.




Report No.: RF180718D12-2                     Page No. 10 / 23                       Report Format Version: 6.1.1


4       Test Types and Results
4.1     Radiated Emission and Bandedge Measurement
4.1.1    Limits of Radiated Emission and Bandedge Measurement


The field strength of emissions from intentional radiators operated within these frequency bands shall comply
with the following

             Fundamental                  Field Strength of Fundamental       Field Strength of Harmonics
              Frequency                          (millivolts/meter)                (microvolts/meter)

           902 ~ 928 MHz                                 50                                500
         2400 ~ 2483.5 MHz                               50                                500
          5725 ~ 5875 MHz                                50                                500
           24 ~ 24.25 GHz                               250                               2500


Emissions radiated outside of the specified frequency bands, except for harmonics, shall be attenuated by
at least 50 dB below the level of the fundamental or to the general radiated emission limits as below table,
whichever is the lesser attenuation

             Frequencies                           Field Strength              Measurement Distance
                (MHz)                            (microvolts/meter)                  (meters)

            0.009 ~ 0.490                           2400/F(kHz)                           300

            0.490 ~ 1.705                          24000/F(kHz)                            30
             1.705 ~ 30.0                                30                                30
                30 ~ 88                                 100                                 3
               88 ~ 216                                 150                                 3
              216 ~ 960                                 200                                 3
              Above 960                                 500                                 3
NOTE:
1.      The lower limit shall apply at the transition frequencies.
2.      Emission level (dBuV/m) = 20 log Emission level (uV/m).
3.      For frequencies above 1000MHz, the field strength limits are based on average detector, however, the
        peak field strength of any emission shall not exceed the maximum permitted average limits, specified
        above by more than 20dB under any condition of modulation.




Report No.: RF180718D12-2                        Page No. 11 / 23                      Report Format Version: 6.1.1


4.1.2 Test Instruments
For below 1GHz test:
DESCRIPTION &                                                                 CALIBRATED        CALIBRATED
                                  MODEL NO.                   SERIAL NO.
 MANUFACTURER                                                                 DATE               UNTIL
 Test Receiver
                                    N9038A                    MY54450088      July 05, 2018      July 04, 2019
 Keysight
 Pre-Amplifier
                                     EMC001340                 980142         Feb. 09, 2018 Feb. 08, 2019
 EMCI
                (*)
 Loop Antenna
                                     EM-6879                   264            Dec. 16, 2016 Dec. 15, 2018
 Electro-Metrics
 RF Cable                            NA                        LOOPCAB-001    Jan. 15, 2018      Jan. 14, 2019
 RF Cable                            NA                        LOOPCAB-002    Jan. 15, 2018      Jan. 14, 2019
 Pre-Amplifier
                                    ZFL-1000VH2B              AMP-ZFL-01      Nov. 09, 2017 Nov. 08, 2018
 Mini-Circuits
 Trilog Broadband Antenna
                                     VULB 9168                 9168-406       Nov. 29, 2017 Nov. 28, 2018
 SCHWARZBECK
 RF Cable                            8D                        966-4-1        Mar. 21, 2018 Mar. 20, 2019
 RF Cable                            8D                        966-4-2        Mar. 21, 2018 Mar. 20, 2019
 RF Cable                            8D                        966-4-3        Mar. 21, 2018 Mar. 20, 2019
 Fixed attenuator
                                     UNAT-5+                   PAD-3m-4-01    Oct. 03, 2017      Oct. 02, 2018
 Mini-Circuits
 Software                            ADT_Radiated_V8.7.08 NA                  NA                 NA
Note:
1. The calibration interval of the above test instruments is 12 months and the calibrations are
   traceable to NML/ROC and NIST/USA.
2. *The calibration interval of the above test instruments is 24 months and the calibrations are
   traceable to NML/ROC and NIST/USA.
3. The test was performed in 966 Chamber No. 4.
4. The CANADA Site Registration No. is 20331-2
5. Loop antenna was used for all emissions below 30 MHz.
6. Tested Date: Sep. 06, 2018




Report No.: RF180718D12-2                      Page No. 12 / 23                        Report Format Version: 6.1.1


For above 1GHz test:
DESCRIPTION &                                                                 CALIBRATED          CALIBRATED
                                  MODEL NO.                   SERIAL NO.
 MANUFACTURER                                                                 DATE                UNTIL
 Test Receiver
                                    N9038A                    MY54450088      July 05, 2018       July 04, 2019
 Keysight
 Horn_Antenna
                                    BBHA 9120D                9120D-783       Dec. 12, 2017       Dec. 11, 2018
 SCHWARZBECK
 Pre-Amplifier
                                    ZVA-183-S+                AMP-ZVA-03      May 10, 2018        May 09, 2019
 Mini-Circuits
 RF Cable                           EMC104-SM-SM-1200 160923                  Jan. 29, 2018       Jan. 28, 2019
 RF Cable                           EMC104-SM-SM-2000 150318                  Jan. 29, 2018       Jan. 28, 2019
 RF Cable                           EMC104-SM-SM-5000 150321                  Jan. 29, 2018       Jan. 28, 2019
 Pre-Amplifier
                                    EMC184045SE               980387          Jan. 29, 2018       Jan. 28, 2019
 EMCI
 Horn_Antenna
                                    BBHA 9170                 BBHA9170608 Dec. 14, 2017           Dec. 13, 2018
 SCHWARZBECK
 RF Cable                           EMC102-KM-KM-1200 160925                  Jan. 29, 2018       Jan. 28, 2019
 Software                           ADT_Radiated_V8.7.08 NA                   NA                  NA
 Boresight Antenna Tower &
 Turn Table                         MF-7802BS                 MF780208530 NA                      NA
 Max-Full
Note:
1. The calibration interval of the above test instruments is 12 months and the calibrations are
   traceable to NML/ROC and NIST/USA.
2. The test was performed in 966 Chamber No. 4.
3. The CANADA Site Registration No. is 20331-2
4. Loop antenna was used for all emissions below 30 MHz.
5. Tested Date: Oct. 17, 2018




Report No.: RF180718D12-2                      Page No. 13 / 23                         Report Format Version: 6.1.1


4.1.3 Test Procedures
For Radiated emission below 30MHz
 a. The EUT was placed on the top of a rotating table 0.8 meters above the ground at a 3 meter chamber
        room. The table was rotated 360 degrees to determine the position of the highest radiation.

     b. The EUT was set 3 meters away from the interference-receiving antenna, which was mounted on the top
        of a variable-height antenna tower.

     c. Parallel, perpendicular, and ground-parallel orientations of the antenna are set to make the
        measurement.

     d. For each suspected emission, the EUT was arranged to its worst case and the rotatable table was turned
        from 0 degrees to 360 degrees to find the maximum reading.

     e. The test-receiver system was set to Quasi-Peak Detect Function and Specified Bandwidth with
        Maximum Hold Mode.
NOTE:
     1. The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is 9kHz at frequency
        below 30MHz.

For Radiated emission above 30MHz
a. The EUT was placed on the top of a rotating table 0.8 meters (for 30MHz ~ 1GHz) / 1.5 meters (for above
    1GHz) above the ground at 3 meter chamber room for test. The table was rotated 360 degrees to
    determine the position of the highest radiation.
b.      The EUT was set 3 meters away from the interference-receiving antenna, which was mounted on the top
        of a variable-height antenna tower.
c.      The height of antenna is varied from one meter to four meters above the ground to determine the
        maximum value of the field strength. Both horizontal and vertical polarizations of the antenna are set to
        make the measurement.
d.      For each suspected emission, the EUT was arranged to its worst case and then the antenna was tuned
        to heights from 1 meter to 4 meters and the rotatable table was turned from 0 degrees to 360 degrees to
        find the maximum reading.
e.      The test-receiver system was set to quasi-peak detect function and specified bandwidth with maximum
        hold mode when the test frequency is below 1 GHz.
f.      The test-receiver system was set to peak and average detect function and specified bandwidth with
        maximum hold mode when the test frequency is above 1 GHz. If the peak reading value also meets
        average limit, measurement with the average detector is unnecessary.


Note:
1. The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is 120kHz for
    Quasi-peak detection (QP) at frequency below 1GHz.
2.      The resolution bandwidth of test receiver/spectrum analyzer is 1 MHz and the video bandwidth is 3 MHz
        for Peak detection (PK) at frequency above 1GHz.
3.      The resolution bandwidth of test receiver/spectrum analyzer is 1 MHz and the video bandwidth is 3 MHz
        for Average detection (AV) at frequency above 1GHz.
4.      All modes of operation were investigated and the worst-case emissions are reported.


4.1.4      Deviation from Test Standard

     No deviation.


Report No.: RF180718D12-2                         Page No. 14 / 23                        Report Format Version: 6.1.1


4.1.5   Test Setup

 For Radiated emission below 30MHz


                                                                    1m
            EUT&                       3m
            Support Units

                              Turn Table

               80cm


                                     Ground Plane
                                     Test Receiver




 For Radiated emission 30MHz to 1GHz

                                                       Ant. Tower
                                                                     1-4m
                                                                     Variable
                                           3m
                                            10m
              EUT&
              Support Units

                                  Turn Table

                  80cm


                                       Ground Plane

                                       Test Receiver




Report No.: RF180718D12-2               Page No. 15 / 23                 Report Format Version: 6.1.1


 For Radiated emission above 1GHz



                                                                   Ant. Tower         1-4m
                                                                                      Variable
               EUT&                              3m
               Support Units

                                       Turn Table
                                                       Absorber

                  150cm


                                              Ground Plane
                                              Test Receiver




 For the actual test configuration, please refer to the attached file (Test Setup Photo).




4.1.6   EUT Operating Conditions

Controlling software (Console Port use”Test command”) has been activated to set the EUT on specific status.




Report No.: RF180718D12-2                       Page No. 16 / 23                            Report Format Version: 6.1.1


                                                                                                                     Eooert
                                                                                                                      venitas




4.1.7    Test Results
Above 1GHz Data :

CHANNEL                       TX Channel 15                      DETECTOR               Peak (PK)

FREQUENCY RANGE |1GHz ~ 25GHz                                    FUNCTION               Average (AV)

                      ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M
                       EMISSION                                    ANTENNA   TABLE         RAW          CORRECTION
NO.      I(:':E'(:)     LEVEL     (d;llljllvl;rm)   MI(\:BG)IN     HEIGHT     ANGLE       VALUE            FACTOR
                       (dBuV/m)                                      (m)     (Degree)     (dBuV)            (dB/m)
  1      2332.00        57.6 PK       74.0            16.4          117 H       12          59.6             —2.0
 2       2332.00        47.9 AV       54.0            —6.1          1.17 H      12          49.9             2.0
 3       2400.00        56.7 PK       74.0            17.3          1.17 H      12          58.9             2.2
 4       2400.00        44.5 AV       54.0            —9.5          1.17 H      12          46.7             —2.2
 5      *2415.00        93.1 PK      114.0            —20.9         1.17 H      12          95.5             —2.4
 6      *2415.00        72.4 AV       94.0            —21.6         1.17 H      12          74.8             —2.4
 7       4830.00        42.6 PK       74.0            —81.4         2.80 H      12          40.8             1.8
 8       4830.00        82.1 AV       54.0            —21.9         2.80 H      12          30.3             1.8
 9       7245.00        44.3 PK       74.0            —29.7         1.25 H     295          36.3             8.0
 10      7245.00        33.3 AV       54.0            —20.7         1.25 H     295          25.3             8.0
                       ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M
                       EMISSION                                    ANTENNA   TABLE         RAW          CORRECTION
NO.      I(:':E'(:)     LEVEL     (d;llljllvl;rm)   MI(\:BG)IN     HEIGHT     ANGLE       VALUE            FACTOR
                       (dBuV/m)                                      (m)     (Degree)     (dBuV)            (dB/m)
  1      2332.00        58.3 PK       74.0            15.7          1.24 V     294          60.3             2.0
 2       2332.00        50.1 AV       54.0            39            1.24 V     294          52.1             2.0
 3       2400.00        57.0 PK       74.0            —17.0         1.24 V     294          59.2             —2.2
 4       2400.00        45.4 AV       54.0            86            1.24 V     294          47.6             2.2
 5      *2415.00        94.0 PK      114.0            20.0          1.24 V     294          96.4             —2.4
 6      *2415.00        73.2 AV       94.0            —20.8         1.24 V     294          75.6             —2.4
 7       4830.00        46.0 PK       74.0            —28.0         1.19 V     305          44.2             1.8
 8       4830.00        35.5 AV       54.0            —18.5         1.19 V     305          39.7             1.8
 9       7245.00        44.2 PK       74.0            —29.8         1.18 V     305          36.2             8.0
 10      7245.00        33.8 AV       54.0            —20.2         1.18 V     305          25.8             8.0
REMARKS:
      1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
      2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) — Pre—Amplifier Factor(dB)
      3. The other emission levels were very low against the limit.
      4. Margin value = Emission Level — Limit value
      5. " * ": Fundamental frequency.




Report No.: RF180718D12—2                              Page No. 17 / 23                            Report Format Version: 6.1.1


CHANNEL                     TX Channel 39            DETECTOR                 Peak (PK)
FREQUENCY RANGE             1GHz ~ 25GHz             FUNCTION                 Average (AV)


                  ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M
                   EMISSION                             ANTENNA     TABLE        RAW          CORRECTION
        FREQ.                     LIMIT     MARGIN
NO.                 LEVEL                                HEIGHT     ANGLE       VALUE           FACTOR
        (MHz)                   (dBuV/m)     (dB)
                   (dBuV/m)                                (m)     (Degree)     (dBuV)           (dB/m)
  1     2311.00      57.5 PK     74.0        -16.5        1.21 H     18           59.5             -2.0
  2     2311.00      48.1 AV     54.0         -5.9        1.21 H     18           50.1             -2.0
  3     2400.00      56.1 PK     74.0        -17.9        1.21 H     18           58.3             -2.2
  4     2400.00      43.9 AV     54.0        -10.1        1.21 H     18           46.1             -2.2
  5    *2439.00      92.3 PK     114.0       -21.7        1.21 H     18           94.9             -2.6
  6    *2439.00      71.6 AV     94.0        -22.4        1.21 H     18           74.2             -2.6
  7     2483.50      57.2 PK     74.0        -16.8        1.21 H     18           59.6             -2.4
  8     2483.50      45.8 AV     54.0         -8.2        1.21 H     18           48.2             -2.4
  9     4878.00      39.8 PK     74.0        -34.2        2.81 H      8           37.8              2.0
 10     4878.00      31.2 AV     54.0        -22.8        2.81 H      8           29.2              2.0
 11     7317.00      48.5 PK     74.0        -25.5        1.12 H     116          40.1              8.4
 12     7317.00      38.4 AV     54.0        -15.6        1.12 H     116          30.0              8.4
                    ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M
                   EMISSION                             ANTENNA     TABLE        RAW          CORRECTION
        FREQ.                     LIMIT     MARGIN
NO.                 LEVEL                                HEIGHT     ANGLE       VALUE           FACTOR
        (MHz)                   (dBuV/m)     (dB)
                   (dBuV/m)                                (m)     (Degree)     (dBuV)           (dB/m)
  1     2311.00      58.0 PK     74.0        -16.0        1.03 V     294          60.0             -2.0
  2     2311.00      50.4 AV     54.0         -3.6        1.03 V     294          52.4             -2.0
  3     2400.00      56.2 PK     74.0        -17.8        1.03 V     294          58.4             -2.2
  4     2400.00      43.9 AV     54.0        -10.1        1.03 V     294          46.1             -2.2
  5    *2439.00      93.4 PK     114.0       -20.6        1.03 V     294          96.0             -2.6
  6    *2439.00      72.5 AV     94.0        -21.5        1.03 V     294          75.1             -2.6
  7     2483.50      57.3 PK     74.0        -16.7        1.03 V     294          59.7             -2.4
  8     2483.50      46.1 AV     54.0         -7.9        1.03 V     294          48.5             -2.4
  9     4878.00      44.5 PK     74.0        -29.5        1.23 V     309          42.5              2.0
 10     4878.00      33.9 AV     54.0        -20.1        1.23 V     309          31.9              2.0
 11     7317.00      42.6 PK     74.0        -31.4        2.67 V     194          34.2              8.4
 12     7317.00      32.8 AV     54.0        -21.2        2.67 V     194          24.4              8.4
REMARKS:
   1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
   2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
   3. The other emission levels were very low against the limit.
   4. Margin value = Emission Level – Limit value
   5. " * ": Fundamental frequency.




Report No.: RF180718D12-2                     Page No. 18 / 23                           Report Format Version: 6.1.1


CHANNEL                     TX Channel 59            DETECTOR                 Peak (PK)
FREQUENCY RANGE             1GHz ~ 25GHz             FUNCTION                 Average (AV)


                  ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M
                   EMISSION                             ANTENNA     TABLE        RAW          CORRECTION
        FREQ.                     LIMIT     MARGIN
NO.                 LEVEL                                HEIGHT     ANGLE       VALUE           FACTOR
        (MHz)                   (dBuV/m)     (dB)
                   (dBuV/m)                                (m)     (Degree)     (dBuV)           (dB/m)
  1     2331.00      57.7 PK     74.0        -16.3        1.15 H     15           59.7             -2.0
  2     2331.00      48.2 AV     54.0         -5.8        1.15 H     15           50.2             -2.0
  3     2400.00      56.4 PK     74.0        -17.6        1.15 H     15           58.6             -2.2
  4     2400.00      44.0 AV     54.0        -10.0        1.15 H     15           46.2             -2.2
  5    *2459.00      92.0 PK     114.0       -22.0        1.15 H     15           94.6             -2.6
  6    *2459.00      71.1 AV     94.0        -22.9        1.15 H     15           73.7             -2.6
  7     2483.50      56.3 PK     74.0        -17.7        1.15 H     15           58.7             -2.4
  8     2483.50      43.6 AV     54.0        -10.4        1.15 H     15           46.0             -2.4
  9     4918.00      39.6 PK     74.0        -34.4        2.76 H     22           37.6              2.0
 10     4918.00      31.0 AV     54.0        -23.0        2.76 H     22           29.0              2.0
 11     7377.00      48.6 PK     74.0        -25.4        1.09 H     131          40.0              8.6
 12     7377.00      37.5 AV     54.0        -16.5        1.09 H     131          28.9              8.6
                    ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M
                   EMISSION                             ANTENNA     TABLE        RAW          CORRECTION
        FREQ.                     LIMIT     MARGIN
NO.                 LEVEL                                HEIGHT     ANGLE       VALUE           FACTOR
        (MHz)                   (dBuV/m)     (dB)
                   (dBuV/m)                                (m)     (Degree)     (dBuV)           (dB/m)
  1     2331.00      58.2 PK     74.0        -15.8        1.02 V     296          60.2             -2.0
  2     2331.00      50.4 AV     54.0         -3.6        1.02 V     296          52.4             -2.0
  3     2400.00      56.4 PK     74.0        -17.6        1.02 V     296          58.6             -2.2
  4     2400.00      44.1 AV     54.0         -9.9        1.02 V     296          46.3             -2.2
  5    *2459.00      93.1 PK     114.0       -20.9        1.02 V     296          95.7             -2.6
  6    *2459.00      72.4 AV     94.0        -21.6        1.02 V     296          75.0             -2.6
  7     2483.50      56.7 PK     74.0        -17.3        1.02 V     296          59.1             -2.4
  8     2483.50      44.4 AV     54.0         -9.6        1.02 V     296          46.8             -2.4
  9     4918.00      45.3 PK     74.0        -28.7        1.24 V     306          43.3              2.0
 10     4918.00      34.8 AV     54.0        -19.2        1.24 V     306          32.8              2.0
 11     7377.00      42.8 PK     74.0        -31.2        2.66 V     184          34.2              8.6
 12     7377.00      32.3 AV     54.0        -21.7        2.66 V     184          23.7              8.6
REMARKS:
   1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
   2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
   3. The other emission levels were very low against the limit.
   4. Margin value = Emission Level – Limit value
   5. " * ": Fundamental frequency.




Report No.: RF180718D12-2                     Page No. 19 / 23                           Report Format Version: 6.1.1


Below 1GHz Data:
CHANNEL                     TX Channel 15            DETECTOR
                                                                              Quasi-Peak (QP)
FREQUENCY RANGE             9kHz ~ 1GHz              FUNCTION


                  ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M
                   EMISSION                             ANTENNA     TABLE        RAW         CORRECTION
        FREQ.                     LIMIT     MARGIN
NO.                 LEVEL                                HEIGHT     ANGLE       VALUE          FACTOR
        (MHz)                   (dBuV/m)     (dB)
                   (dBuV/m)                                (m)     (Degree)     (dBuV)          (dB/m)
  1      33.61       20.1 QP      40.0       -19.9        1.00 H     152         29.0             -8.9
  2     149.72       20.0 QP      43.5       -23.5        1.00 H     72          27.6             -7.6
  3     591.44       27.5 QP      46.0       -18.5        2.00 H     206         27.0              0.5
  4     723.38       29.6 QP      46.0       -16.4        1.50 H     286         27.4              2.2
  5     863.18       33.1 QP      46.0       -12.9        2.00 H     192         28.5              4.6
  6     954.58       34.8 QP      46.0       -11.2        1.50 H     17          28.8              6.0
REMARKS:
   1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
   2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
   3. Margin value = Emission Level – Limit value
   4. The emission levels were very low against the limit of frequency range 9kHz~30MHz: the amplitude of
      spurious emissions attenuated more than 20 dB below the permissible value to be report.




Report No.: RF180718D12-2                     Page No. 20 / 23                          Report Format Version: 6.1.1


CHANNEL                     TX Channel 15            DETECTOR
                                                                              Quasi-Peak (QP)
FREQUENCY RANGE             9kHz ~ 1GHz              FUNCTION


                    ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M
                   EMISSION                             ANTENNA     TABLE        RAW         CORRECTION
        FREQ.                     LIMIT     MARGIN
NO.                 LEVEL                                HEIGHT     ANGLE       VALUE          FACTOR
        (MHz)                   (dBuV/m)     (dB)
                   (dBuV/m)                                (m)     (Degree)     (dBuV)          (dB/m)
  1      39.55       22.2 QP      40.0       -17.8        1.00 V     201         30.5             -8.3
  2     109.93       20.2 QP      43.5       -23.3        1.50 V     231         31.0            -10.8
  3     142.67       20.2 QP      43.5       -23.3        2.00 V     202         28.2             -8.0
  4     628.78       29.9 QP      46.0       -16.1        1.50 V     360         28.6              1.3
  5     802.29       32.1 QP      46.0       -13.9        2.00 V     111         28.3              3.8
  6     937.63       34.1 QP      46.0       -11.9        1.00 V     137         28.0              6.1
REMARKS:
   1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
   2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
   3. Margin value = Emission Level – Limit value
   4. The emission levels were very low against the limit of frequency range 9kHz~30MHz: the amplitude of
      spurious emissions attenuated more than 20 dB below the permissible value to be report.




Report No.: RF180718D12-2                     Page No. 21 / 23                          Report Format Version: 6.1.1


5    Pictures of Test Arrangements


 Please refer to the attached file (Test Setup Photo).




Report No.: RF180718D12-2                      Page No. 22 / 23   Report Format Version: 6.1.1


Appendix – Information on the Testing Laboratories


We, Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch, were founded in 1988 to
provide our best service in EMC, Radio, Telecom and Safety consultation. Our laboratories are FCC
recognized accredited test firms and accredited according to ISO/IEC 17025.

If you have any comments, please feel free to contact us at the following:

Linkou EMC/RF Lab                                      Hsin Chu EMC/RF/Telecom Lab
Tel: 886-2-26052180                                    Tel: 886-3-6668565
Fax: 886-2-26051924                                    Fax: 886-3-6668323


Hwa Ya EMC/RF/Safety Lab
Tel: 886-3-3183232
Fax: 886-3-3270892


Email: service.adt@tw.bureauveritas.com
Web Site: www.bureauveritas-adt.com

The address and road map of all our labs can be found in our web site also.



--- END ---




Report No.: RF180718D12-2                      Page No. 23 / 23                  Report Format Version: 6.1.1



Document Created: 2019-03-27 09:47:54
Document Modified: 2019-03-27 09:47:54

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC