RF Exposure

FCC ID: PPQ-CR8702N

RF Exposure Info

Download: PDF
FCCID_1484429

                                                                            Report No. 112045R-RFUSP42V01




          RF Exposure Evaluation declaration


                Product Name JukeBlox Networked Media Module
                Model No.    CR870-2N
                FCC ID       PPQ-CR8702N




Applicant Lite-On Technology Corp.
Address 4F, 90 ,Chien 1 Road,Chung-Ho,Taipei Hsien 235,Taiwan,R.O.C.




                      Date of Receipt             Feb. 01, 2010
                      Date of Declaration May. 23, 2011
                      Report No.                  112045R-RFUSP42V01




The declaration results relate only to the samples calculated.
The declaration shall not be reproduced except in full without the written approval of QuieTek Corporation.
This report must not be used to claim product endorsement by NVLAP any agency of the U.S. Government




                                             Page: 1 of 3


                                                                            Report No. 112045R-RFUSP42V01


1.      RF Exposure Evaluation

1.1.    Limits

        According to FCC 1.1310: The criteria listed in the following table shall be used to evaluate the
        environment impact of human exposure to radio frequency (RF) radiation as specified in 1.1307(b)
        LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE)
        Frequency Range       Electric Field       Magnetic Field      Power Density        Average Time
                                                                                 2
        (MHz)                 Strength (V/m)       Strength (A/m)      (mW/cm )             (Minutes)
                                    (A) Limits for Occupational/ Control Exposures
               300-1500                  --                    --             F/300                  6
           1500-100,000                  --                    --                5                   6
                              (B) Limits for General Population/ Uncontrolled Exposures
               300-1500                  --                    --             F/1500                 6
           1500-100,000                  --                    --                1                   30
        F= Frequency in MHz


       Friis Formula
       Friis transmission formula: Pd = (Pout*G)/(4*pi*r2)


       Where
       Pd = power density in mW/cm2
       Pout = output power to antenna in mW
       G = gain of antenna in linear scale
       Pi = 3.1416
       R = distance between observation point and center of the radiator in cm


       Pd id the limit of MPE, 1 mW/cm2 . If we know the maximum gain of the antenna and the total power
       input to the antenna, through the calculation, we will know the distance r where the MPE limit is
       reached.



1.2.    Test Procedure

         Software provided by client enabled the EUT to transmit and receive data at lowest, middle and
         highest channel individually.
         The temperature and related humidity: 18℃and 78% RH.




                                                Page: 2 of 3


                                                                        Report No. 112045R-RFUSP42V01




1.3.        Test Result of RF Exposure Evaluation

            Product        :    JukeBlox Networked Media Module
            Test Item      :    RF Exposure Evaluation
            Test Site      :    No.3 OATS

External Antenna Gain
Antenna Gain: The maximum Gain measured in fully anechoic chamber is 4.19 dBi in logarithm scale.
802.11b
Output Power Into Antenna & RF Exposure Evaluation Distance (4.19 dBi):
                                            Output Power to Antenna   Power Density at R = 20 cm
   Channel              Frequency (MHz)
                                                     (mW)                     (mW/cm2)
       1                    2412.00                 34.8337                    0.018186
       6                    2437.00                 36.3078                    0.018955
       11                   2462.00                 36.3915                    0.018999


802.11g
Output Power Into Antenna & RF Exposure Evaluation Distance (4.19 dBi):
                                            Output Power to Antenna   Power Density at R = 20 cm
   Channel              Frequency (MHz)
                                                     (mW)                     (mW/cm2)
       1                    2412.00                132.7394                    0.069300
       6                    2437.00                133.9677                    0.069941
       11                   2462.00                137.4042                    0.071735


The distance r (4th column) calculated from the Fries transmission formula is far shorter than 20 cm
separation requirement.




                                                Page: 3 of 3



Document Created: 2011-06-02 15:45:04
Document Modified: 2011-06-02 15:45:04