Modular Request Letter

FCC ID: PPD-AR6103

Cover Letter(s)

Download: PDF
FCCID_1426239

Applicant/Grantee       Atheros Communications Inc.
FCC ID:                 PPD- AR6103
                                      Section 15.212 Modular Transmitters
Request for Modular Approval                     Request for Limited Modular Approval
                        Requirements                              EUT Conditions              Comply (Y/N)
                                    Single Modular Approval Requirements
  1      The radio elements of the modular            SiP package has a full                  Y
         transmitter must have their own              Metallic coating.
         shielding. The physical crystal and
         tuning capacitors may be located
         external to the shielded radio elements.
  2      The modular transmitter must have            All inputs to the modules               Y
         buffered modulation/data inputs (if such are buffered through logic
         inputs are provided) to ensure that the      or microprocessor inputs.
         module will comply with Part 15
         requirements under conditions of
         excessive data rates or over-modulation.
  3      The modular transmitter must have its        The transmitter has                     Y
         own power supply regulation.                 its own power supply
                                                      regulator.
  4      The modular transmitter must comply          Device complies with 15.203 &           Y
         with the antenna and transmission            15.204(c) via a permanent trace between
         system requirements of Sections 15.203, SiP antenna output and the U.FL
         15.204(b) and 15.204(c). The antenna         connector or integrated antenna.
         must either be permanently attached or
         employ a “unique” antenna coupler (at
         all connections between the module and
         the antenna, including the cable). The
         “professional installation” provision of
         Section 15.203 is not applicable to
         modules but can apply to limited
         modular approvals under paragraph (b)
         of this section.
  5      The modular transmitter must be tested       Device was tested outside               Y
         in a stand-alone configuration, i.e., the    the host for modular
         module must not be inside another            approval. Refer to setup
         device during testing for compliance         photos.
         with Part 15 requirements. Unless the
         transmitter module will be battery
         powered, it must comply with the AC
         line conducted requirements found in
         Section 15.207. AC or DC power lines
         and data input/output lines connected to
         the module must not contain ferrites,
         unless they will be marketed with the
         module (see Section 15.27(a)). The
         length of these lines shall be the length
         typical of actual use or, if that length is
         unknown, at least 10 centimeters to
         insure that there is no coupling between


        the case of the module and supporting
        equipment. Any accessories, peripherals,
        or support equipment connected to the
        module during testing shall be
        unmodified and commercially available
        (see Section 15.31(i)).
    6   The modular transmitter must be
        equipped with either a permanently                   SiP package is too small to affix
        affixed label or must be capable of                  label or readable text with FCCID.
        electronically displaying its FCC
        identification number.                               End Integrators are instructed to
        (A) If using a permanently affixed label, the
        modular transmitter must be labeled with its own     label host device with the required
        FCC identification number, and, if the FCC           text: Contains FCC ID: PPD-AR6103
        identification number is not visible when the        and to instruct where to find
        module is installed inside another device, then
                                                             the FCCID on the product.
        the outside of the device into which the module is
        installed must also display a label referring to
        the enclosed module. This exterior label can use
        wording such as the following: “Contains
        Transmitter Module
        FCC ID: XYZMODEL1” or “Contains FCC ID:
        XYZMODEL1.” Any similar wording
        that expresses the same meaning may be used.
        The Grantee may either provide such a label, an
        example of which must be included in the
        application for equipment
        authorization, or, must provide adequate
        instructions along with the module which explain
        this requirement. In the latter case, a copy of
        these instructions must be included in the
        application for equipment authorization.
        (B) If the modular transmitter uses an electronic
        display of the FCC identification number, the
        information must be readily accessible and
        visible on the modular transmitter or on the
        device in which it is installed. If the module is
        installed inside another device, then the outside
        of the device into which the module is installed
        must display a label referring to the enclosed
        module. This exterior label can use wording such
        as the following:
        “Contains FCC certified transmitter module(s).”
        Any similar wording that expresses the same
        meaning may be used. The user manual must
        include instructions on how to access the
        electronic display. A copyof these instructions
        must be included in the application for
        equipment authorization.
                                                                                                    Y
        The modular transmitter must comply
7       with requirements that
        ordinarily apply to a complete                               Refer to “Instuctions to OEM
        transmitter and the manufacturer must                        Integrators”.
        provide adequate inst ructions along with
        the module to explain any such
        requirements. A copy of these
        instructions must be included in the


          application for equipment authorization.
   8      The modular transmitter must comply        Transmitter meets                          Y
          with any applicable RF exposure            RF Exposure requirements.
          requirements in its final configuration.   of Refer to submitted test reports.

                                                       .
A limited modular approval may be granted for single or split modular transmitters that do not comply with
all of the above requirements, e.g., shielding, minimum signaling amplitude, buffered modulation/data inputs, or
power supply regulation, if the manufacturer can demonstrate by alternative means in the application for
equipment authorization that the modular transmitter meets all the applicable Part 15 requirements under the
operating conditions in which the transmitter will be used. Limited modular approval also may be granted in
those instances where compliance with RF exposure rules is demonstrated only for particular product
configurations. The applicant for certification must state how control of the end product into which the module
will be installed will be maintained such that full compliance of the end product is always ensured.



Document Created: 2011-01-12 10:38:50