Part 15C Report

FCC ID: PPD-AR5BXB63

Test Report

Download: PDF
FCCID_1143380

                                                               RF - TEST REPORT




Report Number                                          : 68/760.9.130.01                                Date of Issue:               25 June 2009



Model                                                  : PC-81006N

Product Type                                           : Notebook

Applicant                                              : Wanlida Group Co., Ltd.

Address                                                : No. 618 Jiahe Road, Wanlida Industry Zone,

                                                           Xiamen Fujian, China 361006

Production Facility                                    : Wanlida Group Co., Ltd.

Address                                                : Wanlida Industry Zone, Nanjing, Fujian, China 363601




Test Result                                            :  Positive                    Negative



Total pages including
Appendices                                             : 18



Jiangsu TÜV Product Service Ltd. – Shenzhen Branch is a subcontractor to TÜV SÜD Product Service GmbH according to the principles outlined in ISO 17025.

Jiangsu TÜV Product Service Ltd. – Shenzhen Branch reports apply only to the specific samples tested under stated test conditions. Construction of the actual
test samples has been documented. It is the manufacturer's responsibility to assure that additional production units of this model are manufactured with identical
electrical and mechanical components. The manufacturer/importer is responsible to the Competent Authorities in Europe for any modifications made to the
production units which result in non-compliance to the relevant regulations. Jiangsu TÜV Product Service Ltd. – Shenzhen Branch shall have no liability for any
deductions, inferences or generalizations drawn by the client or others from Jiangsu TÜV Product Service Ltd. – Shenzhen Branch issued reports.

This report is the confidential property of the client. As a mutual protection to our clients, the public and ourselves, extracts from the test report shall not be
reproduced except in full without our written approval




Report Number: 68/760.9.130.01                                                                                                                      Page 1 of 18
                                                           Jiangsu TÜV Product Service Ltd. – Shenzhen Branch
6 floor, H Hall, Century Craftwork Culture Square, No. 4001, Fuqiang Road, Futian District, Shenzhen 518048, P. R. China, Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


1 Table of Contents


1      Table of Contents…………………………………………………………………….............. 2

2      Details about the Test Laboratory…………………………………………………………… 3

3      Description of the Equipment Under Test………...………………………………….……..                                                                                              4

4      Summary of Test Standards…………………...………………………………………….…. 5

5      Summary of Test Results….…………………...…………………………………………….                                                                                                        6

6      General Remarks……………………………………………………………………………...                                                                                                              7

7      Technical Requirements………………………………………………………………………                                                                                                            8
       7.1 Conducted Emission AC Power Port…………………………………….….……….                                                                                                    8
       7.2 Conducted Peak Power………………………………………………………….……                                                                                                            12
       7.3 Spurious Radiated Emissions………………………………………………….…..…                                                                                                      14

8      System Measurement Uncertainty……………………………………………………..……                                                                                                       18




Report Number: 68/760.9.130.01                                                                                                                    Page 2 of 18
                                                           Jiangsu TÜV Product Service Ltd. – Shenzhen Branch
6 floor, H Hall, Century Craftwork Culture Square, No. 4001, Fuqiang Road, Futian District, Shenzhen 518048, P. R. China, Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


2 Details about the Test Laboratory


Details about the Test Laboratory

Company name:                       Jiangsu TÜV Product Service Ltd. – Shenzhen Branch
                                    6th Floor, H Hall,
                                    Century Craftwork Culture Square,
                                    No. 4001, Fuqiang Road,
                                    Futian District 518048,
                                    Shenzhen,P.R.C.

Telephone:                          86 755 8828 6998
Fax:                                86 755 8828 5299


Company name:                       China Shenzhen Academy of Metrology and Quality Inspection,
                                    Metrology and Quality Inspection building,
                                    Central Section of LongZhu Road,
                                    Nan Shan,
                                    Shenzhen,

Telephone:                          86 755 2694 1599
Fax:                                86 755 2694 1545


Company name:                       Audix Technology (shenzhen) Co.,Ltd
                                    Block Shenzhen, Science & Industry Park,
                                    Nantou, Shenzhen,
                                    Guangdong,
                                    China

Telephone:                          86 755 2663 9496
Fax:                                86 755 2663 2877




Report Number: 68/760.9.130.01                                                                                                                    Page 3 of 18
                                                           Jiangsu TÜV Product Service Ltd. – Shenzhen Branch
6 floor, H Hall, Century Craftwork Culture Square, No. 4001, Fuqiang Road, Futian District, Shenzhen 518048, P. R. China, Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


3 Description of the Equipment Under Test


Description of the Equipment Under Test

Product:                                          Notebook

Model no.:                                        PC-81006N

Serial number:                                    NIL

Options and accessories:                          NIL

Rating:                                           DC 12V 3A, 36W
                                                  AC Adaptor:
                                                  Model: MPA-12030
                                                  Input: 100-240V ~ 50/60Hz 1A MAX
                                                  Output: +12V DC 3A
Antenna:                                          Integral antenna inside the EUT, NOT accessible by end user

RF Transmission
Frequency:                                        2400-2483.5MHz

Description of the EUT:                           NIL

Auxiliary Equipment and Cable Used during Test:

                   DESCRIPTION                     MANUFACTURER                        MODEL NO.(SHIELD)                         S/N(LENGTH)
                   LCD monitor                             Lenovo                               9227-AE1                            V1TDB38
                    Keyboard                               Lenovo                              SK-8825 (L)                          02553778
                      Mouse                                Lenovo                               MO28UOL                            4418011108
                   Headphone                                Ouyun                                 OH601                                ----
                  USB flash drive                          Kingston                           Data Traveller                           ----
                     SD card                               Kingston                            SD4/4GBFE                               ----
                    VGA cable                              Lenovo                                 Shield                             140cm
                  AC Power cable                           Lenovo                                Unshield                            180cm




Report Number: 68/760.9.130.01                                                                                                                    Page 4 of 18
                                                           Jiangsu TÜV Product Service Ltd. – Shenzhen Branch
6 floor, H Hall, Century Craftwork Culture Square, No. 4001, Fuqiang Road, Futian District, Shenzhen 518048, P. R. China, Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


4 Summary of Test Standards

                                                          Test Standards
FCC Part 15 Subpart C                        PART 15 - RADIO FREQUENCY DEVICES
                                             Subpart C - Intentional Radiators




Report Number: 68/760.9.130.01                                                                                                                    Page 5 of 18
                                                           Jiangsu TÜV Product Service Ltd. – Shenzhen Branch
6 floor, H Hall, Century Craftwork Culture Square, No. 4001, Fuqiang Road, Futian District, Shenzhen 518048, P. R. China, Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


5 Summary of Test Results


                                                            Technical Requirements
FCC Part 15 Subpart C
Test Condition                                                                                     Pages                   Test Result
                                                                                                                      Pass     Fail                          N/A
15.107 15.207 Conducted Emission AC Power Port                                                          8

15.247 (b) (1) Conducted peak output power                                                             12

15.247(d) 15.209 15.109 Spurious radiated emissions                                                    14




Report Number: 68/760.9.130.01                                                                                                                    Page 6 of 18
                                                           Jiangsu TÜV Product Service Ltd. – Shenzhen Branch
6 floor, H Hall, Century Craftwork Culture Square, No. 4001, Fuqiang Road, Futian District, Shenzhen 518048, P. R. China, Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


6 General Remarks

Remarks
This submittal(s) (test report) is intended for the Class 2 permissive change of 8.2.11 b/g
PCIExpress Minicard, Model No.: A5BXB63, FCC ID: PPD-AR5BXB63.

The product [PC-81006N] uses 2 provided hard disks: Model WD2500BEVT-22ZCT0 and
Model MHZ2160BH G2. The worse results are listed inside the report, which test with hard
disk MHZ2160BH G2.

SUMMARY:

All tests according to the regulations cited on page 5 were


 - Performed

 - Not Performed


The Equipment Under Test


 - Fulfills the general approval requirements.

 - Does not fulfill the general approval requirements.


Sample Received Date:                                        May 22 2009

Testing Start Date:                                          May 22 2009

Testing End Date:                                            Jun 10 2009


- Jiangsu TÜV Product Service Ltd. – Shenzhen Branch -

Reviewed by:                                                                              Prepared by:




______________________________________________                                            __________________________________________
                            Paul Yu                                                                                      Ken Li
                       EMC Project Manager                                                                          EMC Test Engineer




Report Number: 68/760.9.130.01                                                                                                                    Page 7 of 18
                                                           Jiangsu TÜV Product Service Ltd. – Shenzhen Branch
6 floor, H Hall, Century Craftwork Culture Square, No. 4001, Fuqiang Road, Futian District, Shenzhen 518048, P. R. China, Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


7 Technical Requirement

7.1 Conducted Emission

Test Method
1 The EUT was placed on a table, which is 0.8m above ground plane
2 The power line of the EUT is connected to the AC mains through a Artificial Mains Network
(A.M.N.).
3 Maximum procedure was performed to ensure EUT compliance
4 A EMI test receiver (R&S Test Receiver ESCS30) is used to test the emissions from both
sides of AC line

Limit


                                       Frequency                              QP Limit                           AV Limit
                                          MHz                                  dBμV                               dBμV
                                       0.150-0.500                             66-56*                             56-46*
                                         0.500-5                                 56                                 46
                                           5-30                                  60                                 50
                             Decreasing linearly with logarithm of the frequency




Report Number: 68/760.9.130.01                                                                                                                    Page 8 of 18
                                                           Jiangsu TÜV Product Service Ltd. – Shenzhen Branch
6 floor, H Hall, Century Craftwork Culture Square, No. 4001, Fuqiang Road, Futian District, Shenzhen 518048, P. R. China, Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Conducted Emission


                   Conducted Disturbance
                   EUT:                   M/N:PC-81006N
                   Op Cond:               WiFi Transmitting
                   Test Spec:             L
                   Comment:               AC 120V/60Hz




                    dBuV                Mkr : 194.00 kHz 45.9 dBuV
                   70




                   60                                                                                                                           ConQP_B




                   50                                                                                                                           ConAV_B




                   40




                   30




                   20




                   10




                    0
                         0.15                                        1                                                10                      30
                                                                                                                                              MHz




               Frequency                     Cable Loss                    Reading                QP Test result              QP Limit            Margin
                  MHz                           dB                          dBμV                      dBμV                     dBμV                 dB
                 0.202                                9.8                      34.9                    44.7                     63.5               18.8
                 0.270                                9.8                      26.5                    36.3                     61.1               24.8


               Frequency                     Cable Loss                    Reading                AV Test result               AV Limit           Margin
                  MHz                           dB                          dBμV                      dBμV                      dBμV                dB
                 0.202                                9.8                      22.3                    32.1                      53.5              21.4
                 0.270                                9.8                      12.6                    22.4                      51.1              28.7

Remark: Test Result= Reading + Cable Loss



Report Number: 68/760.9.130.01                                                                                                                    Page 9 of 18
                                                           Jiangsu TÜV Product Service Ltd. – Shenzhen Branch
6 floor, H Hall, Century Craftwork Culture Square, No. 4001, Fuqiang Road, Futian District, Shenzhen 518048, P. R. China, Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Conducted Emission


                   Conducted Disturbance
                   EUT:                   M/N:PC-81006N
                   Op Cond:               WiFi Transmitting
                   Test Spec:             N
                   Comment:               AC 120V/60Hz




                    dBuV                Mkr : 194.00 kHz 49.5 dBuV
                   70




                   60                                                                                                                           ConQP_B




                   50                                                                                                                           ConAV_B




                   40




                   30




                   20




                   10




                    0
                         0.15                                        1                                                10                      30
                                                                                                                                              MHz




               Frequency                     Cable Loss                    Reading                QP Test result              QP Limit            Margin
                  MHz                           dB                          dBμV                      dBμV                     dBμV                 dB
                 0.202                                9.8                      36.6                    46.4                     63.5               17.1
                 0.266                                9.8                      27.1                    36.9                     61.2               24.3

               Frequency                     Cable Loss                    Reading                AV Test result               AV Limit           Margin
                  MHz                           dB                          dBμV                      dBμV                      dBμV                dB
                 0.202                                9.8                      20.9                    30.7                      53.5              22.8
                 0.266                                9.8                      10.8                    20.6                      51.2              30.6

Remark: Test Result= Reading + Cable Loss



Report Number: 68/760.9.130.01                                                                                                                    Page 10 of 18
                                                           Jiangsu TÜV Product Service Ltd. – Shenzhen Branch
6 floor, H Hall, Century Craftwork Culture Square, No. 4001, Fuqiang Road, Futian District, Shenzhen 518048, P. R. China, Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Test Equipment List

Conducted Emission Test


        DESCRIPTION                            MANUFACTURER  MODEL NO.                                     SERIAL NO.                 CAL.DUE.DATE
         ESPI Test Receiver                    ROHDE&SCHWARZ    ESPI 3                                       100379                     2009-12-05
         TWO Line-V-NETW                       ROHDE&SCHWARZ   EZH3-Z5                                       100253                     2009-12-05




Report Number: 68/760.9.130.01                                                                                                                    Page 11 of 18
                                                           Jiangsu TÜV Product Service Ltd. – Shenzhen Branch
6 floor, H Hall, Century Craftwork Culture Square, No. 4001, Fuqiang Road, Futian District, Shenzhen 518048, P. R. China, Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


7.2 Conducted peak output power

Test Method
The transmitter output is connected to the Spectrum analyzer. The Spectrum analyzer is set to
the peak power detection.

Limits for conducted peak output power measurements


                                  Frequency Range                               Limit                               Limit
                                        MHz                                      W                                  dBm
                                     2400-2483                                   ≤1                                  ≤30



Conducted peak output power

                                                  IEEE 802.11g Modulation Test Result
                                                                           Conducted Peak
                                               Frequency                    Output Power                      Result
                                                  MHz                           dBm
                                              CH1 2412MHz                      16.01                           Pass
                                              CH2 2437MHz                      16.67                           Pass
                                              CH3 2462MHz                      17.52                           Pass

                                                  IEEE 802.11b Modulation Test Result
                                                                           Conducted Peak
                                               Frequency                    Output Power                      Result
                                                  MHz                           dBm
                                              CH1 2412MHz                      16.08                           Pass
                                              CH2 2437MHz                      17.05                           Pass
                                              CH3 2462MHz                      18.00                           Pass




Report Number: 68/760.9.130.01                                                                                                                    Page 12 of 18
                                                           Jiangsu TÜV Product Service Ltd. – Shenzhen Branch
6 floor, H Hall, Century Craftwork Culture Square, No. 4001, Fuqiang Road, Futian District, Shenzhen 518048, P. R. China, Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Test Equipment


Maximum transmit power Test


        DESCRIPTION                            MANUFACTURER                        MODEL NO.               SERIAL NO.                CAL.DUE.DATE
           Spectrum Analyzer                              Agilent                      E4446A                US44300459                   2010-05-10




Report Number: 68/760.9.130.01                                                                                                                    Page 13 of 18
                                                           Jiangsu TÜV Product Service Ltd. – Shenzhen Branch
6 floor, H Hall, Century Craftwork Culture Square, No. 4001, Fuqiang Road, Futian District, Shenzhen 518048, P. R. China, Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


7.3 Spurious radiated emissions

Test Method
1 The EUT is placed on a turntable, which is 0.8m above ground plane.
2 The turntable shall be rotated for 360 degrees to determine the position of maximum
emission level
3 EUT is set 3m away from the receiving antenna, which is varied from 1m to 4m to find out
the highest emissions.
4 Maximum procedure was performed on the six highest emissions to ensure EUT compliance.
5 each emission was to be maximized by changing the polarization of receiving antenna both
horizontal and vertical.

Limit


                     Frequency                         Field Strength                     Field Strength                           Detector
                        MHz                                 uV/m                             dBμV/m
                        30-88                                100                                40                                      QP
                       88-216                                150                               43.5                                     QP
                       216-960                               200                                46                                      QP
                      960-1000                               500                                54                                      QP
                     Above 1000                              500                                54                                      AV
                     Above 1000                             5000                                74                                      PK




Report Number: 68/760.9.130.01                                                                                                                    Page 14 of 18
                                                           Jiangsu TÜV Product Service Ltd. – Shenzhen Branch
6 floor, H Hall, Century Craftwork Culture Square, No. 4001, Fuqiang Road, Futian District, Shenzhen 518048, P. R. China, Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Spurious radiated emissions

IEEE 802.11g Modulation test result-2402MHz

                      Cable        Antenna          Reading            Emission                                                                            Result
  Frequency           Loss          Factor                              Level               Polarization             Limit              Detector
      MHz              dB           dB/m               dBuV            dBuV/m                                       dBμV/m
     80.055              1.4           9.6              25.1             36.1                 Horizontal             40.0                   QP              Pass
    188.082              2.2           10.3             20.0             32.5                  Vertical              43.5                   QP              Pass
   4804.000              3.8           33.3             18.4             55.5                 Horizontal              74                    PK              Pass
   4804.000              3.8           33.3              8.3             45.5                 Horizontal              54                    AV              Pass
   4804.000              3.8           33.3             17.3             54.4                  Vertical               74                    PK              Pass
   4804.000              3.8           33.3              8.8             45.9                  Vertical               54                    AV              Pass

Test Result-2437MHz

                     Cable        Antenna          Reading             Emission                                                                             Result
 Frequency           Loss          Factor                                Level               Polarization               Limit            Detector
    MHz               dB           dB/m               dBuV              dBuV/m                                         dBμV/m
  4874.000              3.9           33.3             21.3               58.5                 Horizontal                74                   PK             Pass
  4874.000              3.9           33.3             10.2               47.4                 Horizontal                54                   AV             Pass
  4874.000              3.9           33.3             19.0               56.2                  Vertical                 74                   PK             Pass
  4874.000              3.9           33.3              8.5               45.7                  Vertical                 54                   AV             Pass

Test Result-2462MHz

                      Cable        Antenna          Reading            Emission                                                                            Result
 Frequency            Loss          Factor                               Level               Polarization              Limit             Detector
    MHz                dB           dB/m              dBuV              dBuV/m                                        dBμV/m
  4924.000              3.9           33.3             21.6               58.8                 Horizontal               74                   PK             Pass
  4924.000              3.9           33.3             11.7               48.9                 Horizontal               54                   AV             Pass
  4924.000              3.9           33.3             20.3               57.5                  Vertical                74                   PK             Pass
  4924.000              3.9           33.3              9.3               46.5                  Vertical                54                   AV             Pass


Remark: Emission Level= Cable Loss(include amplifier factor) + Antenna Factor + Reading




Report Number: 68/760.9.130.01                                                                                                                    Page 15 of 18
                                                           Jiangsu TÜV Product Service Ltd. – Shenzhen Branch
6 floor, H Hall, Century Craftwork Culture Square, No. 4001, Fuqiang Road, Futian District, Shenzhen 518048, P. R. China, Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Spurious radiated emissions

IEEE 802.11b Modulation test result-2402MHz

                      Cable        Antenna          Reading            Emission                                                                            Result
  Frequency           Loss          Factor                              Level               Polarization             Limit              Detector
      MHz              dB           dB/m               dBuV            dBuV/m                                       dBμV/m
    164.332              2.2           10.1             22.3             34.6                 Horizontal             43.5                   QP              Pass
     72.168              1.2           5.3              27.2             33.7                  Vertical              40.0                   QP              Pass
   4804.000              3.8           33.3             18.2             55.3                 Horizontal              74                    PK              Pass
   4804.000              3.8           33.3              8.0             45.1                 Horizontal              54                    AV              Pass
   4804.000              3.8           33.3             16.5             53.6                  Vertical               74                    PK              Pass
   4804.000              3.8           33.3              7.4             44.5                  Vertical               54                    AV              Pass

Test Result-2437MHz

                     Cable        Antenna          Reading             Emission                                                                             Result
 Frequency           Loss          Factor                                Level               Polarization               Limit            Detector
    MHz               dB           dB/m               dBuV              dBuV/m                                         dBμV/m
  4874.000              3.9           33.3             18.9               56.1                 Horizontal                74                   PK             Pass
  4874.000              3.9           33.3              7.3               44.5                 Horizontal                54                   AV             Pass
  4874.000              3.9           33.3             17.8               55.0                  Vertical                 74                   PK             Pass
  4874.000              3.9           33.3              7.5               44.7                  Vertical                 54                   AV             Pass

Test Result-2462MHz

                      Cable        Antenna          Reading            Emission                                                                            Result
 Frequency            Loss          Factor                               Level               Polarization              Limit             Detector
    MHz                dB           dB/m              dBuV              dBuV/m                                        dBμV/m
  4924.000              3.9           33.3             20.6               57.8                 Horizontal               74                   PK             Pass
  4924.000              3.9           33.3              7.4               44.6                 Horizontal               54                   AV             Pass
  4924.000              3.9           33.3             19.5               56.7                  Vertical                74                   PK             Pass
  4924.000              3.9           33.3              6.5               43.7                  Vertical                54                   AV             Pass


Remark: Emission Level= Cable Loss(include amplifier factor) + Antenna Factor + Reading




Report Number: 68/760.9.130.01                                                                                                                    Page 16 of 18
                                                           Jiangsu TÜV Product Service Ltd. – Shenzhen Branch
6 floor, H Hall, Century Craftwork Culture Square, No. 4001, Fuqiang Road, Futian District, Shenzhen 518048, P. R. China, Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Test Equipment List


Spurious radiated emissions Test


        DESCRIPTION                            MANUFACTURER                        MODEL NO.               SERIAL NO.                CAL.DUE.DATE
                  Spectrum                                Agilent                      E4446A                US44300459                   2010-05-10
                    SG                                     HP                          83723B                US34490501                   2010-05-10
                    Amp                                    HP                           8449B                3008A02495                   2010-05-24
                  Antenna                                 EMCO                           3115                 9607-4877                   2010-05-27




Report Number: 68/760.9.130.01                                                                                                                    Page 17 of 18
                                                           Jiangsu TÜV Product Service Ltd. – Shenzhen Branch
6 floor, H Hall, Century Craftwork Culture Square, No. 4001, Fuqiang Road, Futian District, Shenzhen 518048, P. R. China, Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


8 System Measurement Uncertainty


For a 95% confidence level, the measurement expanded uncertainties for defined systems, in
accordance with the recommendations of ISO 17025 were:

                                                         System Measurement Uncertainty
                                           Items                                                                    Extended Uncertainty
                RE                             Field strength (dBμV/m)                                       U=4.6dB; k=2(30MHz-1GHz)
                CE                            Disturbance Voltage (dBμV)                                           U=3.3dB; k=2




Report Number: 68/760.9.130.01                                                                                                                    Page 18 of 18
                                                           Jiangsu TÜV Product Service Ltd. – Shenzhen Branch
6 floor, H Hall, Century Craftwork Culture Square, No. 4001, Fuqiang Road, Futian District, Shenzhen 518048, P. R. China, Tel. +86 755 8828 6998, Fax: +86 755 8828 5299



Document Created: 2009-07-13 07:28:29
Document Modified: 2009-07-13 07:28:29

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC