                        FCC TEST REPORT

                           REPORT NO.: RF920116R02
                            MODEL NO.: CU-108R


                            ACCORDING: FCC Guidelines for Human Exposure
                                       IEEE C95.1




                     APPLICANT: Inventec Appliances Corp.

                      ADDRESS: 37, Wu-Kung 5 Rd., Wu-Ku Industrial Park,
                               Wu-Ku Hsiang, Taipei Hsien, Taiwan, R.O.C




                     ISSUED BY: Advance Data Technology Corporation

                LAB LOCATION: 47 14th Lin, Chiapau Tsun, Linko, Taipei,
                              Taiwan, R.O.C.




                                                                Lab Code: 200102-0


                                                 0528
                                              ILAC MRA



ADT No.: 920116R02


FCC ID: POTCU-108R




          RF Exposure Measurement (Mobile Device)
1. Introduction

2.4 GHz frequency band is regarded specially as a dangerous band for its heating
harmfulness to the human body. That’s why microwave oven is operating in this
frequency band. The manufacturer whose product is working in this frequency band is
obligatory to prove the harmfulness of his product.
In this document, we try to prove the safety of radiation harmfulness to the human body
for our product. The limit for Maximum Permissible Exposure (MPE) specified in FCC
1.1310 is followed. The Gain of the antenna used in this product is measured in a Fully
Anechoic Chamber (FAC), and the maximum total power input to the antenna is
measured. Through the Friis transmission formula and the maximum gain of the antenna,
we can calculate the distance, away from the product, where the limit of MPE is reached.



2. Classification
The antenna of the product, under normal use condition, is at least 20cm away from the
body of the user. Warning statement for keeping 20cm separation distance and the
prohibition of operating next to a person has been printed on the users manual. So, this
product is classified as the mobile Device.


3. RF Exposure Limit

According to FCC 1.1310: The criteria listed in the following table shall be used to
evaluate the environmental impact of human exposure to radio-frequency (RF) radiation
as specified in 1.1307(b).




ADT No.: 920116R02


FCC ID: POTCU-108R




LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE)

   Frequency          Electric Field   Magnetic Field    Power Density    Average Time
     Range           Strength (V/m)    Strength (A/m)      (mW/cm2)         (minutes)
     (MHz)
                     (A)Limits For Occupational / Control Exposures
     30-300               61.4             0.163              1.0              6
   300-1500                …                …               F/300              6
 1500-100,000              …                …                 5                6
              (B)Limits For General Population / Uncontrolled Exposure
     30-300               27.5             0.073              0.2             30
   300-1500                …                …               F/1500            30
 1500-100,000              …                …                 1.0             30
F = Frequency in MHz

4. Friis Formula


Friis transmission formula : Pd = (Pout*G) / (4*pi*r2)


where
Pd = power density in mW/cm2
Pout = output power to antenna in mW
G = gain of antenna in linear scale
Pi = 3.1416
R = distance between observation point and center of the radiator in cm


Pd is the limit of MPE, 1 mW/cm2. If we know the maximum Gain of the antenna and the
total power input to the antenna, through the calculation, we will know the distance r
where the MPE limit is reached.

Ref. : David K. Cheng, Field and Wave Electromagnetics, Second Edition,
      Page 640, Eq. (11-133).

5. EUT Operating condition
The software provided by Manufacturer enabled the EUT to transmit and receive data at
lowest, middle and highest channel individually.




ADT No.: 920116R02


FCC ID: POTCU-108R




6. Test Results

6.1 Antenna Gain


The maximum Gain measured in Fully Anechoic Chamber is 1.5dBi or 1.41 (numeric).

6.2 Output Power Into Antenna & RF Exposure Distance :


                       CHANNEL            OUTPUT POWER MINIMUM ALLOWABLE
   CHANNEL            FREQUENCY            TO ANTENNA  DISTANCE ( R ) FROM
                         (MHz)                (mW)       SKIN (Centi-Meter)
        1                  2412                 26.303               1.719
        6                  2437                 27.669               1.764
        11                 2462                 26.485               1.725
The minimum allowable distance is very close to the enclosure of the antenna and is
very far away from the human being under normal use condition.




ADT No.: 920116R02



Document Created: 2003-01-30 10:15:53
Document Modified: 2003-01-30 10:15:53