MPE Calculation Yabby

FCC ID: POJDMLWAN915

RF Exposure Info

Download: PDF
FCCID_4235787

                                                            MPE CALCULATION
                                                        FCC ID: POJDMLWAN915


RF Exposure Requirements:                                                         47 CFR §1.1307(b)

RF Radiation Exposure Limits:                                                     47 CFR §1.1310

RF Radiation Exposure Guidelines:                                                 FCC OST/OET Bulletin Number 65

EUT Frequency Band: 900MHz                                                        902.3-914.9 MHz
Limits for General Population/Uncontrolled Exposure in the band of:               300 -1,500 MHz
Power Density Limit:                                                              f/1500 mW / cm2


Equation:          S = PG / 4πR2 or R = √PG / 4πS
          Where,   S = Power Density
                   P = Power Input to Antenna
                   G = Antenna Gain
                   R = distance to the center of radiated antenna
______________________________________________________________________________________________________________________
EUT: DM-LWAN-915
Host: Yabby LWAN 915
(900MHz Radio): Power = 18.73 dBm, Power density = 0.014 mW/ cm2


                        Conduc                  Tune-     Tolerance
                CH                 Antenna                                               Calculated
                           ted                   Up       Max Power     Measurement                   MPE Limit
               Freq                 Gain                                                    MPE                    Pass/F
   Type                  Power                  Toler       (dBm)       Distance (cm)                 (mW/cm2)
              (MHz)                 (dBi)                                                (mW/cm2)                    ail
                         (dBm)                  ance

  900MHz       902.3     18.73         -1       ±1dB         19.73           20             0.014        0.60      Pass




The Above Result had shown that the Device complied with MPE requirement.




Completed By: Gary Chou
SIEMIC, Inc
775 Montague Expressway, Milpitas, CA 95035
Phone: (408) 526-1188
Date: 02/21/2019