MPE

FCC ID: PODGMRS-45

RF Exposure Info

Download: PDF
FCCID_4421397

                        RF EXPOSURE EVALUATION

          1. TEST RESULT CERTIFICATION

Applicant              TYT Electronics Co., Ltd.
                       Block 39-1, Optoelectronics-information industry base, Nan'an,
Address
                       Quanzhou, Fujian, China.
manufacturer           TYT Electronics Co., Ltd.
                       Block 39-1, Optoelectronics-information industry base, Nan'an,
Address
                       Quanzhou, Fujian, China.
Factory                TYT Electronics Co., Ltd.
                       Block 39-1, Optoelectronics-information industry base, Nan'an,
Address
                       Quanzhou, Fujian, China.
Product Designation:   Analog Transceiver

Brand Name:            TYT

Test Model:            GMR45

FCC ID:                PODGMRS-45

Date of Test:          Aug. 12, 2019~Aug. 20, 2019


         2. TECHNICAL INFORMATION

         A major technical description of EUT is described as following:
Operation Frequency           GMRS: 462.5625MHz -462.7125MHz(5W)
                                    462.5500MHz -462.7250MHz(45W)
                                     467.5500MHz -467.7250MHz(45W)
Modulation                    FM
Antenna Designation           Detachable
Antenna type                  External antenna
Output power                  5W/45W
Antenna gain                  0dBi
Power Supply                  DC 13.8V

       Channel List:


CH. No             CH. Freq            Power      CH. No                   CH. Freq   Power
  1                462.5625                          13                    462.6750
  2                462.5875                          14                    462.7000   45W
  3                462.6125                          15                    462.7250
  4                462.6375              5W          16                    467.5500
  5                462.6625                          17                    467.5750
  6                462.6875                          18                    467.6000
  7                462.7125                          19                    467.6250
                                                                                      45W
  8                462.5500                          20                    467.6500
  9                462.5750                          21                    467.6750
 10                462.6000              45W         22                    467.7000
  11               462.6250                          23                    467.7250
 12                462.6500


  3. RF EXPOSURE MEASUREMENT
  3.1 INTRODUCTION
  Human exposure to RF emissions from mobile devices (47 CFR §2.1091) may be
  evaluated based on the MPE limits adopted by the FCC for electric and magnetic
  field strength and/or power density, as appropriate, since exposures are assumed
  to occur at distances of 20 cm or more from persons.

  The 1992 ANSI/IEEE standard (See Listed limit table) specifies a minimum
  separation distance of 20 cm for performing reliable field measurements to
  determine adherence to MPE limits.
  If the minimum separation distance between a transmitter and nearby persons
  is more than 20 cm under normal operating conditions, compliance with MPE
  limits may be determined at such distance from the transmitter. When applicable,
  operation instructions and prominent warning labels may be used to alert the
  exposed persons to maintain a specified distance from the transmitter or to limit
  their exposure durations and usage conditions to ensure compliance.


  3.2 FCC LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE)
  LIMITS FOR GENERAL POPULATION / UNCONTROLLED EXPOSURE
   Frequency                      Magnetic    Power     Averaging
                 E-field Strength                       Time
     Range                         Field     Density
                        (E) (V/m)                         |E|2, |H|2
      (MHz)                       Strength     (S)
                                            (mW/cm2)        or S
                                     (H)
                                   (A/m)                 (Minutes)

 0.3 -- 1.34             614              1.63             (100)*                30
 1.34 -- 30             824/f            2.19/f           (180/f2)*              30
 30 -- 300              27.5             0.073              0.2                  30
 300 -- 1500              --               --              f/1500                30
 1500 -- 100,000          --               --               1.0                  30


  *Note:

   1. f= Frequency in MHz * Plane-wave Equivalent Power Density
   2.The averaging time for General Population/Uncontrolled exposure to fixed
transmitters is not applicable for mobile and portable transmitters. See 47 CFR §§2.1091
and 2.1093 on source-based time-averaging requirement for mobile and portable
transmitters.


  4. CLASSIFICATION OF THE ASSESSMENT METHODS

  According to user manual, The antenna of the product, under normal use condition is

  at least 107.3 cm away from the body of the user. Warning statement to the user for

  keeping at least 107.3 cm separation distance and the prohibition of operating to a

  person has been printed on the user’s manual. So, this product under normal use is

  located on electromagnetic far field between the human body.
S=PG/4πR²
Where:
S=power density
P=power input to antenna

  G=power gain of the antenna in the direction of interest relative to an isotropic radiator
     R=distance to the center of radiation of the antenna


              5. EUT OPERATION CONDITION

              Make the EUT to transmit at channel 4 , channel 11 and channel 19 individually.



              6. TEST RESULTS
              Note: report the worst result in this part

              Antenna Gain=0 dBi (Numeric 1), π=3.141, Duty cycle=50%



Frequency        Output         Output          Correct        Power         Power Density       Result
                 Power          Power           Power         Density              Limit

  MHz             dBm            mW              mW          mW/cm2             mW/cm2          Pass/Fail

462.6250         46.49          44570           22285         0.3081             0.3084           Pass


            Note:
            1.The output power is refer to AGC02931190802FE10.
            2.Correct Power=Output Power*Duty cycle.
            3.According to the user manual, the minimum separate distance which used for MPE
              calculate is 107.3cm.



Document Created: 2019-08-30 09:25:20