Test Report Conducted Emission

FCC ID: PJMMWDBF

Test Report

Download: PDF
FCCID_286519

                                Conducted Emission Test 150 kHz - 30 MHz
                                   according to FCC Part 15 Subpart C
Model:                                                                  Mode:
MWD BF                                                                  - with supply voltage 24 V AC, 60 Hz
Serial no.:
---                                                                     TX + RX on

Applicant:
Feig Elektronik GmbH
Test site:
Shielded room, cabin no. 1
Tested on:
Linecord 24 V AC
Phase A
Date of test:                       Operator:
11/25/2002                          R. Heller
Test performed:                     File name:
automatically

Detector:                                                               Final results:
Peak / Final Results: QP                                                Selected by hand

dBµV                                                                                     Limit1: FCC C / QP       Limit2: FCC C / AV
 100



 90



 80



 70



 60



 50



 40



 30



 20



 10



 0
  0.15                                              1                                                       10                    30
                                                                                                                                 MHz
Result:                                                                 Project file:
Limit kept                                                              50602-20351                           Page        of   Pages
                Senton GmbH / EMI/EMC Laboratories / Aeussere Fruehlingsstrasse 45 / D-94315 Straubing / Tel. +49 9421 55220


                                Conducted Emission Test 150 kHz - 30 MHz
                                   according to FCC Part 15 Subpart C
Model:                                                                  Mode:
MWD BF                                                                  - with supply voltage 24 V AC, 60 Hz
Serial no.:
---                                                                     TX + RX on

Applicant:
Feig Elektronik GmbH
Test site:
Shielded room, cabin no. 1
Tested on:
Linecord 24 V AC
Phase A
Date of test:                       Operator:
11/25/2002                          R. Heller
Test performed:                     File name:
automatically

Detector:                                                               Final results:
Peak / Final Results: QP                                                Selected by hand

      Frequency                Reading               Correction factor                   Value         Limit               Limit
         MHz                    dBµV                       dB                            dBµV          dBµV              exceeded
          0.155                  50.7                                                    50.7           65.7
          0.207                  42.9                                                    42.9           63.3
          0.260                  45.6                                                    45.6           61.4
          0.315                  45.0                                                    45.0           59.8
          0.365                  42.2                                                    42.2           58.6
          0.520                  40.7                                                    40.7           56.0
          0.575                  37.2                                                    37.2           56.0
          0.730                  38.5                                                    38.5           56.0
          0.885                  37.8                                                    37.8           56.0
          1.146                  38.9                                                    38.9           56.0
          1.300                  38.2                                                    38.2           56.0
          1.354                  39.5                                                    39.5           56.0
          1.565                  37.4                                                    37.4           56.0




Result:                                                                 Project file:
Limit kept                                                              50602-20351                            Page       of   Pages
                Senton GmbH / EMI/EMC Laboratories / Aeussere Fruehlingsstrasse 45 / D-94315 Straubing / Tel. +49 9421 55220


                                Conducted Emission Test 150 kHz - 30 MHz
                                   according to FCC Part 15 Subpart C
Model:                                                                  Mode:
MWD BF                                                                  - with supply voltage 24 V AC, 60 Hz
Serial no.:
---                                                                     TX + RX on

Applicant:
Feig Elektronik GmbH
Test site:
Shielded room, cabin no. 1
Tested on:
Linecord 24 V AC
Phase A
Date of test:                       Operator:
11/25/2002                          R. Heller
Test performed:                     File name:
automatically

Detector:                                                               Final results:
Average / Final Results: AV                                             Selected by hand

dBµV                                                                                     Limit1: FCC C / QP       Limit2: FCC C / AV
 100



 90



 80



 70



 60



 50



 40



 30



 20



 10



 0
  0.15                                              1                                                       10                    30
                                                                                                                                 MHz
Result:                                                                 Project file:
Limit kept                                                              50602-20351                           Page        of   Pages
                Senton GmbH / EMI/EMC Laboratories / Aeussere Fruehlingsstrasse 45 / D-94315 Straubing / Tel. +49 9421 55220


                                Conducted Emission Test 150 kHz - 30 MHz
                                   according to FCC Part 15 Subpart C
Model:                                                                  Mode:
MWD BF                                                                  - with supply voltage 24 V AC, 60 Hz
Serial no.:
---                                                                     TX + RX on

Applicant:
Feig Elektronik GmbH
Test site:
Shielded room, cabin no. 1
Tested on:
Linecord 24 V AC
Phase A
Date of test:                       Operator:
11/25/2002                          R. Heller
Test performed:                     File name:
automatically

Detector:                                                               Final results:
Average / Final Results: AV                                             Selected by hand

      Frequency                Reading               Correction factor                   Value         Limit               Limit
         MHz                    dBµV                       dB                            dBµV          dBµV              exceeded
          0.155                  42.3                                                    42.3           55.7
          0.207                  30.9                                                    30.9           53.3
          0.260                  37.1                                                    37.1           51.4
          0.310                  36.0                                                    36.0           50.0
          0.365                  32.1                                                    32.1           48.6
          0.470                  30.6                                                    30.6           46.5
          0.625                  25.6                                                    25.6           46.0
          0.780                  26.4                                                    26.4           46.0
          0.940                  28.7                                                    28.7           46.0
          1.145                  32.4                                                    32.4           46.0
          1.355                  34.3                                                    34.3           46.0
          1.561                  34.0                                                    34.0           46.0
          1.770                  34.4                                                    34.4           46.0
          1.980                  33.0                                                    33.0           46.0
          2.395                  31.5                                                    31.5           46.0
          3.020                  29.0                                                    29.0           46.0
          3.645                  26.3                                                    26.3           46.0




Result:                                                                 Project file:
Limit kept                                                              50602-20351                            Page       of   Pages
                Senton GmbH / EMI/EMC Laboratories / Aeussere Fruehlingsstrasse 45 / D-94315 Straubing / Tel. +49 9421 55220


                                Conducted Emission Test 150 kHz - 30 MHz
                                   according to FCC Part 15 Subpart C
Model:                                                                  Mode:
MWD BF                                                                  - with supply voltage 24 V AC, 60 Hz
Serial no.:
---                                                                     TX + RX on

Applicant:
Feig Elektronik GmbH
Test site:
Shielded room, cabin no. 1
Tested on:
Linecord 24 V AC
Phase B
Date of test:                       Operator:
11/25/2002                          R. Heller
Test performed:                     File name:
automatically

Detector:                                                               Final results:
Peak / Final Results: QP                                                Selected by hand

dBµV                                                                                     Limit1: FCC C / QP       Limit2: FCC C / AV
 100



 90



 80



 70



 60



 50



 40



 30



 20



 10



 0
  0.15                                              1                                                       10                    30
                                                                                                                                 MHz
Result:                                                                 Project file:
Limit kept                                                              50602-20351                           Page        of   Pages
                Senton GmbH / EMI/EMC Laboratories / Aeussere Fruehlingsstrasse 45 / D-94315 Straubing / Tel. +49 9421 55220


                                Conducted Emission Test 150 kHz - 30 MHz
                                   according to FCC Part 15 Subpart C
Model:                                                                  Mode:
MWD BF                                                                  - with supply voltage 24 V AC, 60 Hz
Serial no.:
---                                                                     TX + RX on

Applicant:
Feig Elektronik GmbH
Test site:
Shielded room, cabin no. 1
Tested on:
Linecord 24 V AC
Phase B
Date of test:                       Operator:
11/25/2002                          R. Heller
Test performed:                     File name:
automatically

Detector:                                                               Final results:
Peak / Final Results: QP                                                Selected by hand

      Frequency                Reading               Correction factor                   Value         Limit               Limit
         MHz                    dBµV                       dB                            dBµV          dBµV              exceeded
          0.155                  50.8                                                    50.8           65.7
          0.208                  42.5                                                    42.5           63.3
          0.260                  45.6                                                    45.6           61.4
          0.310                  45.3                                                    45.3           60.0
          0.365                  42.4                                                    42.4           58.6
          0.470                  40.1                                                    40.1           56.5
          0.519                  40.9                                                    40.9           56.0
          0.675                  37.2                                                    37.2           56.0
          0.935                  37.8                                                    37.8           56.0
          1.145                  38.5                                                    38.5           56.0
          1.355                  38.5                                                    38.5           56.0
          1.510                  36.7                                                    36.7           56.0
          1.560                  37.2                                                    37.2           56.0




Result:                                                                 Project file:
Limit kept                                                              50602-20351                            Page       of   Pages
                Senton GmbH / EMI/EMC Laboratories / Aeussere Fruehlingsstrasse 45 / D-94315 Straubing / Tel. +49 9421 55220


                                Conducted Emission Test 150 kHz - 30 MHz
                                   according to FCC Part 15 Subpart C
Model:                                                                  Mode:
MWD BF                                                                  - with supply voltage 24 V AC, 60 Hz
Serial no.:
---                                                                     TX + RX on

Applicant:
Feig Elektronik GmbH
Test site:
Shielded room, cabin no. 1
Tested on:
Linecord 24 V AC
Phase B
Date of test:                       Operator:
11/25/2002                          R. Heller
Test performed:                     File name:
automatically

Detector:                                                               Final results:
Average / Final Results: AV                                             Selected by hand

dBµV                                                                                     Limit1: FCC C / QP       Limit2: FCC C / AV
 100



 90



 80



 70



 60



 50



 40



 30



 20



 10



 0
  0.15                                              1                                                       10                    30
                                                                                                                                 MHz
Result:                                                                 Project file:
Limit kept                                                              50602-20351                           Page        of   Pages
                Senton GmbH / EMI/EMC Laboratories / Aeussere Fruehlingsstrasse 45 / D-94315 Straubing / Tel. +49 9421 55220


                                Conducted Emission Test 150 kHz - 30 MHz
                                   according to FCC Part 15 Subpart C
Model:                                                                  Mode:
MWD BF                                                                  - with supply voltage 24 V AC, 60 Hz
Serial no.:
---                                                                     TX + RX on

Applicant:
Feig Elektronik GmbH
Test site:
Shielded room, cabin no. 1
Tested on:
Linecord 24 V AC
Phase B
Date of test:                       Operator:
11/25/2002                          R. Heller
Test performed:                     File name:
automatically

Detector:                                                               Final results:
Average / Final Results: AV                                             Selected by hand

      Frequency                Reading               Correction factor                   Value         Limit               Limit
         MHz                    dBµV                       dB                            dBµV          dBµV              exceeded
          0.155                  42.4                                                    42.4           55.7
          0.260                  37.3                                                    37.3           51.4
          0.310                  36.5                                                    36.5           50.0
          0.365                  32.6                                                    32.6           48.6
          0.470                  31.4                                                    31.4           46.5
          0.520                  30.7                                                    30.7           46.0
          0.675                  26.8                                                    26.8           46.0
          0.940                  27.3                                                    27.3           46.0
          1.145                  31.2                                                    31.2           46.0
          1.355                  33.1                                                    33.1           46.0
          1.563                  33.7                                                    33.7           46.0
          1.770                  33.6                                                    33.6           46.0
          1.980                  32.4                                                    32.4           46.0
          2.395                  31.1                                                    31.1           46.0
          3.020                  29.2                                                    29.2           46.0
          3.645                  27.1                                                    27.1           46.0




Result:                                                                 Project file:
Limit kept                                                              50602-20351                            Page       of   Pages
                Senton GmbH / EMI/EMC Laboratories / Aeussere Fruehlingsstrasse 45 / D-94315 Straubing / Tel. +49 9421 55220



Document Created: 2002-11-28 14:21:04
Document Modified: 2002-11-28 14:21:04

© 2025 FCC.report