UM

FCC ID: PJMLRU3000

Users Manual

Download: PDF
FCCID_2177331

                                 Annex no. 5

 Functional Description /
      User Manual




Date: 2012-06-11                                                                                                  Vers. no. 1.12
m. dudde hochfrequenz-technik   Rottland 5a   D-51429 Bergisch Gladbach/ Germany   Tel: +49 2207-96890   Fax +49 2207-968920


INSTALLATION



ID ISC.LRU3000 / ID ISC.LRU3500
UHF Long Range Reader




final – public (B)
2013-10-28 – M21016-3e-ID-B


OBID i-scan ® UHF                                  Installation                            ID ISC.LRU3000/3500


                                                     Note
 Copyright 2013 by
         FEIG ELECTRONIC GmbH
         Lange Strasse 4
         D-35781 Weilburg
         Tel.: +49 6471 3109-0
         http://www.feig.de
With the edition of this document, all previous editions become void. Indications made in this manual may be
changed without previous notice.

Copying of this document, and giving it to others and the use or communication of the contents thereof are
forbidden without express authority. Offenders are liable to the payment of damages. All rights are reserved
in the event of the grant of a patent or the registration of a utility model or design.

Composition of the information in this document has been done to the best of our knowledge. FEIG
ELECTRONIC GmbH does not guarantee the correctness and completeness of the details given in this
manual and may not be held liable for damages ensuing from incorrect or incomplete information. Since,
despite all our efforts, errors may not be completely avoided, we are always grateful for your useful tips.
The instructions given in this manual are based on advantageous boundary conditions. FEIG ELECTRONIC
GmbH does not give any guarantee promise for perfect function in cross environments and does not give
any guaranty for the functionality of the complete system which incorporates the subject of this document.
FEIG ELECTRONIC call explicit attention that devices which are subject of this document are not designed
with components and testing methods for a level of reliability suitable for use in or in connection with surgical
implants or as critical components in any life support systems whose failure to perform can reasonably be
expected to cause significant injury to a human. To avoid damage, injury, or death, the user or application
designer must take reasonably prudent steps to protect against system failures.
Use Exclusion in Transportation Market: Devices which are subject of this document may NOT be sold,
used, leased, offer for sale, or otherwise transferred, exported, and imported by anyone in the Transportation
Market. “Transportation Market” means (i) Electronic Toll and Traffic Management (ETTM), (ii) Public Sector
Vehicle Registration, Inspection and Licensing Programs, (iii) Railroad Locomotive and Wagon tracking, (iv)
airport based ground transportation management systems (GTMS) and taxi dispatch, (v) revenue based
parking, and (vi) vehicle initiated mobile payment applications, where the RFID sticker/tag is initially attached
to the vehicle but not incorporated at the point of vehicle manufacture.
FEIG ELECTRONIC GmbH assumes no responsibility for the use of any information contained in this docu-
ment and makes no representation that they free of patent infringement. FEIG ELECTRONIC GmbH does
not convey any license under its patent rights nor the rights of others.
     ®                  ®
OBID and OBID i-scan are registered trademarks of FEIG ELECTRONIC GmbH.




FEIG ELECTRONIC GmbH                              Page 2 of 32                                   M21016-3e-ID-B


OBID i-scan ® UHF                              Installation                        ID ISC.LRU3000/3500


                  General information's regarding this document
• The sign "" indicates extensions or changes of this manual compared with the former issue.

• If bits within one byte are filled with "-", these bit spaces are reserved for future extensions or
   for internal testing- and manufacturing-functions. These bit spaces must not be changed, as this
   may cause faulty operation of the reader.
• The following figure formats are used:
   0...9:             for decimal figures
   0x00...0xFF:       for hexadecimal figures,
   b0...1             for binary figures.
• The hexadecimal value in brackets "[ ]" marks a control byte (command).




FEIG ELECTRONIC GmbH                          Page 3 of 32                               M21016-3e-ID-B


OBID i-scan ® UHF                                              Installation                                      ID ISC.LRU3000/3500


                                                            Contents

1. Safety Instructions / Warning - Read before start-up !                                                                                  6

2. Performance Features of Reader Family ID ISC.LRU3000                                                                                    7

  2.1. Performance features ........................................................................................................ 7

  2.2. Available Reader types ..................................................................................................... 7

  2.3. Available Accessories ....................................................................................................... 7


3. Installation                                                                                                                            8

4. Terminals                                                                                                                               9

  4.1. Antenna Connection ....................................................................................................... 10

  4.2. Power Supply................................................................................................................... 11
      4.2.1. Power Supply via connection X1 ................................................................................ 11
      4.2.2. Power Supply via Power over Ethernet (PoE) ............................................................ 12

  4.3. Interfaces ......................................................................................................................... 13
      4.3.1. Ethernet Interface on connector X2 ............................................................................ 13
      4.3.2. USB Interface on connector X3 .................................................................................. 13
      4.3.3. USB Interface on connector X4 (WLAN) .................................................................... 13
      4.3.4. RS232 Interface on connector X6 .............................................................................. 14
      4.3.5. RS485 Interface on connector X6 .............................................................................. 15
            4.3.5.1. Address assignment of RS485 for bus operation ........................................... 16
      4.3.6. Data-Clock Interface on connector X5 ........................................................................ 16

  4.4. Digital Inputs on connector X5 ....................................................................................... 18

  4.5. Outputs on connector X5 ................................................................................................ 19
      4.5.1. Digital outputs on connector X5 ................................................................................. 19
      4.5.2. Relay outputs on connector X5 .................................................................................. 20


5. Operating and Display Elements                                                                                                         22

  5.1. Status LEDs ..................................................................................................................... 22


FEIG ELECTRONIC GmbH                                          Page 4 of 32                                               M21016-3e-ID-B


OBID i-scan ® UHF                                            Installation                                     ID ISC.LRU3000/3500

  5.2. Reset Push Buttons ........................................................................................................ 23

  5.3. Reader Power adjustment............................................................................................... 24
      5.3.1. EU-Reader according to EN302 208 .......................................................................... 24
      5.3.2. FCC-Reader according to FCC 47 Part 15 ................................................................. 25


6. Technical Data                                                                                                                      26

7. Radio Approvals                                                                                                                     29

  7.1. Europe (CE)...................................................................................................................... 29

  7.2. Declaration of Conformity (Directive 1999/5/EC - R&TTE) ............................................ 30

  7.3. USA (FCC) and Canada (IC) ............................................................................................ 31
      7.3.1. USA (FCC) and Canada (IC) warning notices ............................................................ 31
      7.3.2. Label Information ....................................................................................................... 32
      7.3.3. Installation with FCC / IC Approval ............................................................................. 32
      7.3.4. USA (FCC) and Canada (IC) approved antennas ...................................................... 32




FEIG ELECTRONIC GmbH                                         Page 5 of 32                                              M21016-3e-ID-B


OBID i-scan ® UHF                              Installation                        ID ISC.LRU3000/3500



1. Safety Instructions / Warning - Read before start-up !

•   The device may only be used for the intended purpose designed by for the manufacturer.
•   The operation manual should be conveniently kept available at all times for each user.
•   Unauthorized changes and the use of spare parts and additional devices which have not been
    sold or recommended by the manufacturer may cause fire, electric shocks or injuries. Such
    unauthorized measures shall exclude any liability by the manufacturer.
•   The liability-prescriptions of the manufacturer in the issue valid at the time of purchase are valid
    for the device. The manufacturer shall not be held legally responsible for inaccuracies, errors,
    or omissions in the manual or automatically set parameters for a device or for an incorrect
    application of a device.
•   Repairs may only be executed by the manufacturer.
•   Installation, operation, and maintenance procedures should only be carried out by qualified
    personnel.
•   Use of the device and its installation must be in accordance with national legal requirements
    and local electrical codes .
•   When working on devices the valid safety regulations must be observed.
•   When installing the device in areas covered under FCC 47 CFR Part 15 a minimum separation
    of 23 cm (9 inch) between antenna and the human body must be maintained.
•   Special advice for carriers of cardiac pacemakers:
    Although this device doesn't exceed the valid limits for electromagnetic fields you should keep
    a minimum distance of 25 cm between the device and your cardiac pacemaker and not stay in
    an immediate proximity of the device respective the antenna for some time.




FEIG ELECTRONIC GmbH                          Page 6 of 32                               M21016-3e-ID-B


OBID i-scan ® UHF                               Installation                           ID ISC.LRU3000/3500



2. Performance Features of Reader Family ID ISC.LRU3000

2.1. Performance features
The Reader has been developed for reading passive data carriers, so-called „Smart Labels“, using
an operating frequency in the UHF range.



2.2. Available Reader types
The following Readers are available:


Table 1: Available Reader Types

Reader type                       Description

ID ISC.LRU3500-EU                 Device version for Europe with PoE        (max. 4Watt)

ID ISC.LRU3000-EU                 Device version for Europe without PoE     (max. 2Watt)

ID ISC.LRU3500-FCC                Device version for USA with PoE           (max. 4Watt)

ID ISC.LRU3000-FCC                Device version for USA without PoE        (max. 2Watt)




2.3. Available Accessories
The following optional accessories are currently available:


Table 2: Optional Reader Accessories

Reader type                    Description

                                                           Protection cap for IP 64

                                                             Art.No.: 3558.000.00

ID ISC.LR.CSC-IP64 Connector
Sealing Cap




ID ISC.LRU3x00-MS Mounting                       Rail Mounting Set for ID ISC.LRU3000/3500
Rail Set                                                     Art.No.: 3831.000.00




FEIG ELECTRONIC GmbH                            Page 7 of 32                                 M21016-3e-ID-B


OBID i-scan ® UHF                              Installation                         ID ISC.LRU3000/3500



3. Installation

The Reader is designed for wall-mount, including outdoors. Holes for mounting on a wall are
provided in the housing.
It is not necessary to open the reader housing mounting.




                               261,3 (10.29)                                             68 (2.68)




                                                                     157,3 (6.19)
34 (1.34)
25,5 (1.00)




                                241,7 (9.52)




                                   Figure 1: Installation Drawing




FEIG ELECTRONIC GmbH                           Page 8 of 32                             M21016-3e-ID-B


OBID i-scan ® UHF                                       Installation                            ID ISC.LRU3000/3500



4. Terminals

On the lower side of the reader housing the different cable connectors are positioned. Figure 2:
Connection Overview shows the arrangement of the connectors and Table 3: Connection terminals
shows which connection for the different cables are used for. Table 4: Push button function shows
the available push buttons.




                          X1
                                                                  ANT1        ANT2   ANT3     ANT4

               X2                                 X5
                          X3
                                    X4                                   X6
                                                             T1               T2




                                          Figure 2: Connection Overview


Table 3: Connection terminals

            Connector          Description

             ANT 1-4           Connection of the external antennas (Impedance 50Ω)

                X1             Power supply 24VDC +-5%

                X2             10/100Tbase network connection with RJ-45 (with PoE)

                X3             USB interface for host communication

                X4             USB interface for WLAN-Sticks

                X5             Digital input and output and relay output

                X6             RS232 / 485 interface



Table 4: Push button function

               Push button            Description

                     T1               Internal push button for complete configuration reset

                     T2               External push button for CPU-Reset




FEIG ELECTRONIC GmbH                                   Page 9 of 32                                  M21016-3e-ID-B


OBID i-scan ® UHF                            Installation                            ID ISC.LRU3000/3500



4.1. Antenna Connection
The external SMA antenna connectors are positioned on the lower side of the reader.
The maximum tightening torque for the SMA sockets is 0.45 Nm (4.0 lbf in).


CAUTION:
Exceeding the tightening torque will destroy the plug.


Table 5: External antenna connection

         Terminal                                    Description

         ANT 1 - 4               Connection for external antennas (input impedance 50Ω)




           Figure 3: External antenna connection ANT1-4 and X1 for the power supply


CAUTION:
A direct connection of an antenna to an antenna output with activated DC Voltage (24 VDC,
500 mA) may damage the antenna.




FEIG ELECTRONIC GmbH                        Page 10 of 32                                 M21016-3e-ID-B


OBID i-scan ® UHF                           Installation               ID ISC.LRU3000/3500



4.2. Power Supply

4.2.1. Power Supply via connection X1
The supply voltage of 24 V DC has to be connected to Terminal X1.


Table 6: Pin assignment for power supply

       Terminal     Abbreviation                       Description

       X1 / Pin 1      VDC          Vcc – supply voltage 24VDC +-5%

       X1 / Pin 2      GND          Ground – supply voltage




                           Figure 4: Connection for the power supply


CAUTION:
The reader has to be supplied by a limited power supply (e.g. NEC Class 2/LPS power sup-
ply) according IEC EN 60950-1 chapter 2.5, only.
Reversing the polarity of the supply voltage may destroy the device.
Each reader has to be supplied by a separate external power supply.
An operation of an ID ISC.LRU3500 via an external power supply and Power over Ethernet
(PoE) at the same time is not recommended and can cause interferences during operation.




FEIG ELECTRONIC GmbH                       Page 11 of 32                   M21016-3e-ID-B


OBID i-scan ® UHF                             Installation                       ID ISC.LRU3000/3500



4.2.2. Power Supply via Power over Ethernet (PoE)
Optional the reader (only LRU3500) can be powered via the LAN connector on X2 with the use of a
PoE „Power over Ethernet“ power supply according to IEEE802.3at*, Class4 (30/25,5Watt). The
DC supply can be achieved via the free pin’s 4,5 and 7,8 (Midspan-Power). Also a “Phantom Pow-
ering” (Inline-Power) via the signal pin’s 1,2,3,and 6 is possible. Depending on the cable cross-
section the following cable distances can be used.
Table 7: Maximum cable length if PoE is used

            cable cross-section (CAT5...7)        Maximum cable length for PoE

                       0,4mm                                 ≈ 30m

                       0,6mm                                 ≈ 70m



* For detailed technical information regarding the 802.3at standard, please refer to the most
  recent edition of the corresponding IEEE specification.




                                  Figure 5: LAN and PoE connection
CAUTION:
Take care if PoE is used the maximum reader output power of the reader must be limited to
1Watt.
It must be ensured that the reader is supplied with 42,5 V DC (48 V DC – cable losses) at
least.
This functionality is only available with the reader models ID ISC.LRU3500-EU and ID
ISC.LRU3500-FCC.
An operation of an ID ISC.LRU3500 via an external power supply and Power over Ethernet
(PoE) at the same time is not recommended and can cause interferences during operation.
If Power over Ethernet is used WLAN is not available.



FEIG ELECTRONIC GmbH                         Page 12 of 32                            M21016-3e-ID-B


OBID i-scan ® UHF                            Installation                    ID ISC.LRU3000/3500



4.3. Interfaces

4.3.1. Ethernet Interface on connector X2
The Reader has an integrated 10 / 100 base-T network port for an RJ-45. Connection is made on
X2 and has an automatic “Crossover Detection” according to the 100BASE-T Standard.
With structured cabling CAT 5 cables should be used. This ensures a reliable operation at 10 Mbps
or 100 Mbps.
The prerequisite for using TCP/IP protocol is that each device has a unique address on the net-
work. All Readers have a factory set IP address.
Table 8: Standard factory configuration of the Ethernet connection

                                 Network                      Address

                    IP-Adresse                              192.168.10.10
                    Subnet-Mask                             255.255.255.0

                    Port                                       10001

                    DHCP                                        OFF




NOTE:
The reader is equipped with a DHCP ready Ethernet Interface.



4.3.2. USB Interface on connector X3
The USB socket on the board is terminal X3. The pinout is standardized. The data rate is reduced
to 12 Mbit (USB full speed). A standard USB-cable can be used.




                           Figure 6: USB-Interface for host communication


NOTE:
The length of the USB-cable can have a max. of 5m (20 inch). It is not allowed to use longer
cables.



4.3.3. USB Interface on connector X4 (WLAN)

FEIG ELECTRONIC GmbH                        Page 13 of 32                          M21016-3e-ID-B


OBID i-scan ® UHF                                    Installation                  ID ISC.LRU3000/3500

The USB-Port X4 can be used for a standard WLAN-USB-Stick




                            Figure 7: USB-Interface for external WLAN stick


NOTE:
WLAN shall not be used when the reader is powered via Power over Ethernet (PoE)


The following table gives an overview about successfully tested Wireless LAN Sticks
Table 9: Successfully tested WLAN Sticks

          Manufacturer        Description                           Model

          Buffalo             Wireless-N NFiniti High Power         WLI-UC-G300HP

          Buffalo             Wireless –N NFiniti                   WLI-UC-G300N

          Cisco / Linksys     Wireless Network USB Adapter          WUSB100

          Netgear             Wireless-G 54 USB Adapter             WG111 v3




4.3.4. RS232 Interface on connector X6
The RS232 interface is connected on X6. The transmission parameters can be configured by
means of software protocol.




                               Figure 8: RS232 interface pin-outs on X6




FEIG ELECTRONIC GmbH                                Page 14 of 32                      M21016-3e-ID-B


OBID i-scan ® UHF                               Installation                 ID ISC.LRU3000/3500




       Figure 9: Wiring example for connecting the RS232 interface RS485-Schnittstelle X6



4.3.5. RS485 Interface on connector X6
The connection of the RS485 interface take place via the X6 connector as well. The interface pa-
rameter can be configured via software protocols.




                  Figure 10: RS485 interface pin-outs on X6 (RS485-Interface):


Table 10: RS485 interface pin-outs

                 Abbreviation                          Description

                     GND        RS485 – GND

                      A-        RS485 – (A -)

                      B+        RS485 – (B +)




FEIG ELECTRONIC GmbH                        Page 15 of 32                         M21016-3e-ID-B


OBID i-scan ® UHF                              Installation                      ID ISC.LRU3000/3500



4.3.5.1. Address assignment of RS485 for bus operation
For bus operation the Reader can be assigned the required bus address via software.
The address is assigned by the host computer. The software is used to assign addresses “0”
through “254” to the Reader.
A potential termination of the interface bus can be configured by the software as well.


NOTE:
Since all Readers are factory set with address „0“, they must be connected and configured
one after the other.



4.3.6. Data-Clock Interface on connector X5
The connection of the data-clock interface take place via the digital Outputs OUT1 and OUT2 at
connector X5. The wire for the clock needs to be connected to connector OUT1-C, the wire for the
data needs to be connected to connector OUT2-C.




                              Clock / Data-0

                         Figure 11: Data-Clock Interface on connector X5


NOTE:

FEIG ELECTRONIC GmbH                        Page 16 of 32                                 M21016-3e-ID-B


OBID i-scan ® UHF                         Installation                     ID ISC.LRU3000/3500

The data-clock interface is only available in Scan-Mode.
The data-clock interface cannot be used to configure the reader.
The digital outputs OUT1 and OUT2 are not available, if the data-clock interface is activated.
The data as well as the clock need to be supplied with an external voltage. The output is
configured for max. 24 V DC / 30 mA.




                                  Figure 12: Wiring Example


NOTE:
Please consider possible limitations of the Wiegand Controller regarding the used supply
voltage.
In dependency on the inner circuit of the used Wiegand Controller it is necessary to use
external serial resistors to limit the current on the data and clock wires.
The necessity of the external pull down resistor is depending on the inner circuit of the
used Wiegand Controller




FEIG ELECTRONIC GmbH                     Page 17 of 32                           M21016-3e-ID-B


OBID i-scan ® UHF                             Installation                      ID ISC.LRU3000/3500



4.4. Digital Inputs on connector X5
The optocouplers on Terminal X5 are galvanically isolated from the Reader electronics and must
therefore be externally supplied.




                              Figure 13: Optocoupler pin-outs IN1 – IN5




             Figure 14: Internal and possible external wiring of the optocoupler inputs


Optocoupler input (X5/1-5):
The input LED associated with the optocoupler is connected internally to a series resistor of 500 Ω.
For supply voltages of greater than 10V the input current must be limited to max. 20 mA by means
of an additional series resistor (see Fehler! Verweisquelle konnte nicht gefunden werden.).
Table 11 shows the necessary external resistors for various external voltages Uext.




FEIG ELECTRONIC GmbH                        Page 18 of 32                             M21016-3e-ID-B


OBID i-scan ® UHF                                 Installation                          ID ISC.LRU3000/3500

Table 11: Required external series resistor Rext

                          External voltage Uext          Required external series resistor Rext

                                5 V ... 10 V                              ---

                               11 V ... 15 V                             270 Ω

                               16 V ... 20 V                             560 Ω

                               21 V ... 24 V                             820 Ω



NOTE:
The input is configured for a maximum input voltage of 5-10 V DC and an input current of
max. 20 mA.
Polarity reversal or overload on the input will destroy it.



4.5. Outputs on connector X5

4.5.1. Digital outputs on connector X5
Optocoupler output (X5/1-2):
The transistor connections, collector and emitter, of the optocoupler output are galvanically isolated
from the Reader electronics and are carried to the outside without any internal ancillary circuitry on
Terminal X5. The output must therefore be powered by an external power supply.




                               Figure 15: Optocoupler -Outputs OUT1-2




FEIG ELECTRONIC GmbH                           Page 19 of 32                                      M21016-3e-ID-B


OBID i-scan ® UHF                           Installation                      ID ISC.LRU3000/3500




        Figure 16: Internal and possible external wiring of the optocoupler-outputs OUT1-2


CAUTION:
The output is configured for max. 24 V DC / 30 mA.
Polarity reversal or overload on the output will destroy it.
The output is intended for switching resistive loads only.



4.5.2. Relay outputs on connector X5
There are 3 relay outputs available on connector X5.




                             Figure 17: Relay output pin-outs REL1-3




FEIG ELECTRONIC GmbH                       Page 20 of 32                            M21016-3e-ID-B


OBID i-scan ® UHF                           Installation                       ID ISC.LRU3000/3500

CAUTION:
The relay output is configured for max. 24 V DC / 2 A constant load.
The switching current must not exceed 1A.
The relay output is intended for switching resistive loads only. If an inductive load is con-
nected, the relay contacts must be protected by means of an external protection circuit.




               Figure 18: Internal and possible external wiring of the relay output




FEIG ELECTRONIC GmbH                       Page 21 of 32                              M21016-3e-ID-B


OBID i-scan ® UHF                                      Installation                                 ID ISC.LRU3000/3500



5. Operating and Display Elements

5.1. Status LEDs
Table 12: Configuration of the LEDs




                Host
                                                Warning
             Communication                                                                    ANT 1- 4

                                                            Input
               RUN
                                                           Output




      Green           Yellow       Red                                       Description

        ON             OFF          ON          Boot sequence (ca.10s) after power on
      FLASH            OFF         OFF          Normal Reader operation (without Host communication)
      FLASH           BLINKT       OFF          Reader receives a valid protocol from host
      FLASH            OFF          ON          RF Warning [0x84] (without host communication)
      FLASH                       FLASH         Firmware Activation necessary [0x17] /
       (alternat-      OFF         (alternat-
          ing)                        ing)        Wrong Firmware [0x18]

      FLASH                       FLASH
      (synchro-        OFF        (synchro-     RFC Hardware Error [0xF1]
        nous)                       nous)

                      FLASH       FLASH         Hardware Warning
       OFF            (synchro-   (synchro-
                        nous)       nous)        (ACC EEPROM Error / RFC not detected)

      FLASH            OFF        FLASH         USB Host Error
                                    (fast)

     Firmware Update:
      FLASH           FLASH       FLASH         Firmware transfer from host to reader
                                                  (Please do not switch off the reader or disconnect the interface cable)
             (light in sequence)
      FLASH           FLASH       FLASH         Firmware flash into EEPROM.
                                                  (Please do not switch off the reader or disconnect the interface cable)
                    synchronous


FEIG ELECTRONIC GmbH                                 Page 22 of 32                                         M21016-3e-ID-B


OBID i-scan ® UHF                             Installation                         ID ISC.LRU3000/3500




      Green       Yellow        Red                             Description

     Configurations-Reset:
      FLASH       FLASH       FLASH
                                        While T1 is pushed and hold for maximal 5s
             (light in sequence)
                                        After T1 has been pushed and hold for 5s. Configuration
        ON          ON             ON
                                          Reset has been finished.


     Input / Output LED (yellow):
             Configurable LED.          Can display the status of a digital input or output


     ANT 1 – 4:
                   Green                HF Power switched on
                   Blue                 Tag-Detect
                    Red                 Antenna impedance error (> 50Ohm or <50Ohm)



5.2. Reset Push Buttons
Figure 19 shows the position of the reset push button’s T1 and T2.
At the right side of the connector X6 the push button T2 is positioned. With this push button a CPU-
Reset can be performed.

With the push button T1 within the reader housing on left side of X3 a complete con-
     figuration reset can be performed. For performing a reset you should use a pa-
     per clip and push the button T1 for at least 5 s until the 3 status LED’s (left
     side) are switched on continuously, see 5.1. Status LEDs
Table 12: Configuration of the LEDs
.



Table 12: Configuration of the LEDs




                          Figure 19: Position of the reset-switches T1 and T2

FEIG ELECTRONIC GmbH                         Page 23 of 32                               M21016-3e-ID-B


OBID i-scan ® UHF                                        Installation             ID ISC.LRU3000/3500


5.3. Reader Power adjustment
To achieve the optimum reading performance it is necessary to set the reader output power to the
highest allowed value. This depends on the used reader type (EU / FCC) and the regulation in the
country were the reader is used.



5.3.1. EU-Reader according to EN302 208
According to the standard EN302 208 the maximum radiated power is 2 W e.r.p. (Effective Radiat-
ed Power) in countries of the European Union. The in the reader configured output power Pout de-
pends on the antenna gain in dBi and the attenuation of the antenna cable. If a circular polarized
antenna is used the antenna gain [dBic] can be reduced by 3dB. At a linear polarized antenna the
maximum linear antenna gain [dBi] must be used.
                              POut = Perp - Antenna Gain + Cable loss + 2,1dB**
** Correction Factor to convert the radiated power from e.r.p to e.i.r.p.


For the calculation of the reader output power POut an Excel file „Calc-RF-Power.xls“ can be used.
Available from Feig Electronic GmbH.
Example:




   ** linear antenna = „0“, circular antenna = „1“
Figure 20: Calculation of the output power
In Figure 20 the allowed antenna power is shown for the use of the FEIG standard antenna
ANT.U600/270 –EU and a 6m long Belden H155 coaxial cable.




FEIG ELECTRONIC GmbH                                    Page 24 of 32                 M21016-3e-ID-B


OBID i-scan ® UHF                               Installation                        ID ISC.LRU3000/3500



5.3.2. FCC-Reader according to FCC 47 Part 15
According to the FCC approval, Title 47, Part15 the maximum output power of the reader is limited
to 1 W (30dBm). The maximum radiated power of the antenna should not increase more then 4 W
e.i.r.p. Due to these facts two different cases have to be considered:
If a linear polarized antenna is used which gain is less then 6 dBi (factor 4), or if a circular polarized
antenna is used which gain is less then 9dBic the reader can always be configured to an output
power of 1W.
                           Antenna Gain < 6dBi             →      Pout = 1 W
This would be the case if the FEIG standard antennas ANT.U170/170 -FCC (4dBic) or
ANT.U270/270 -FCC (8,7dBic) are used.
If an antenna is used which gain is more then 6dBi (9dBic) it is necessary to consider the antenna
gain and the attenuation of the antenna cable to calculate the right output power. If a circular polar-
ized antenna is used the antenna gain [G]=dBic can be reduced by 3dB. This is the case if the
FEIG standard antenna ANT.U600/270 -FCC is used. In this configuration the maximum output
power of the reader can be calculated in the following way.
             POut = 36 dBm (4 W e.i.r.p) – Antenna Gain (in dBi) + Cable Loss (in dB)
       POut = 36 dBm (4 W e.i.r.p) – Antenna Gain (in dBic) – 3 dB + Cable Loss (in dB)
The antenna gain of the circular polarized standard antenna ANT.U600/270 is 10,5 dBic. This
could be compared with a gain of 7,5 dBi of a linear polarized antenna (10,5 dBic – 3 dB).


Example 1:
         Antenna ANT.U600/270 and 2 m Belden H155 Coaxial Cable:
                  Pout= 36 dBm – 10,5 dBic + 3 dB + 0,6 dB
                  Pout= 36 dBm – 7,5 dBi + 0,6 dB
                  Pout= 29,1 dBm
                  Reader Configuration = 0,8 Watt
Example 2:
         Antenna ANT.U600/270 and 6m Belden H155 Coaxial Cable:
                  Pout= 36 dBm – 10,5 dBic + 3 dB + 1,8 dB
                  Pout= 36 dBm – 7,5 dBi + 1,8 dB
                  Pout= 30,3 dBm
                  Reader Configuration = 1,0 Watt


According to Example 2 it will only be necessary to adapt the output power of the reader when the
antenna ANT.U600/270 is used if the length of the antenna cable is less then 6m.


FEIG ELECTRONIC GmbH                          Page 25 of 32                                M21016-3e-ID-B


OBID i-scan ® UHF                Installation                       ID ISC.LRU3000/3500



6. Technical Data



MECHANICAL DATA


Housing                               Aluminum powder-coated
Dimension (W x H x D)                 261,3 mm x 157,3 mm x 68 mm)
                                      10.29 inch x 6.19 inch x 2.68 inch
Weight                                2,0 kg (4.4 lb)
Protection Class                      IP 53 (with protection cap IP64)
Colour                                RAL 9003 (Signal White)




ELECTRICAL DATA


Power Supply
• ID ISC.LRU3000                      24 V DC ± 5 % (Noise Ripple: max. 150 mV)
• ID ISC.LRU3500                      24 V DC ± 5 % (Noise Ripple: max. 150 mV)
                                      or Power over Ethernet (min. 42,5 V DC)
Power Consumption                     max. 35 W
Operating Frequency
• EU-Reader                           865 MHz to 868 MHz (EN 302208)
• FCC-Reader                          902 MHz to 928 MHz (FCC47 Part15)

RF-Power
• ID ISC.LRU3000                      300 mW to max. 2 W configurable
• ID ISC.LRU3500                      300 mW to max. 4 W configurable
                                       max. 1 W if powered via Power over Ethernet
Antenna Connection
• ID ISC.LRU3000                      4 x SMA female (50 Ω), internal Multiplexer
• ID ISC.LRU3500                      4 x SMA female (50 Ω), internal Multiplexer,
                                      optional a DC voltage of 24 V DC      / 500 mA
                                      can be activated at the antenna output
Outputs
• 2 x Optocoupler                     24 V DC       / 30 mA (galvanically isolated)
• 3 x Relay (1 x normal open)         24 V DC       / 1 A (switching current), (2A con-
                                      stant load)

FEIG ELECTRONIC GmbH            Page 26 of 32                              M21016-3e-ID-B


OBID i-scan ® UHF                                                      Installation                                           ID ISC.LRU3000/3500


Inputs
• 5 x Optocoupler                                                              max. 5-10 V DC                   / 20 mA

Interfaces                                                                     RS232, RS485, USB (full Speed), Ethernet,
                                                                               USB Host, Data-Clock




FUNCTIONAL PROPERTIES


Protocol Modes                                                                 FEIG ISO HOST Mode (Advanced Protocol
                                                                               Frame)
                                                                               Buffered Read Mode   Automatic Data
                                                                               Scan Mode            Buffering and
                                                                               Notification Mode    Filtering
Supported Transponder Types                                                    EPC Class 1 Generation 2
                                                                               ISO 18000-6-C (Upgrade Code required)
                                                                               further transponder types possible on demand
Optical Indicators                                                             8 LEDs for operating status and diagnostics
Operating System                                                               Linux (64 MB RAM, 256 MB Flash)
Further Features                                                               Anticollision
                                                                               RSSI
                                                                               Real Time Clock
                                                                               RF-Channel monitoring
                                                                               Antenna SWR monitoring
                                                                               Temperature Monitoring*




AMBIENT CONDITIONS


Temperature Range

• Operation                                                                    -25 °C to +55 °C
                                                                               -25 °C to +50 °C (only LRU3500 with PoE)
• Storage                                                                      -25 °C to +85 °C

Humidity                                                                       5 % to 95 % non-condensing



* Caution: Overheating of the device may result in performance losses. It is recommended to activate the RF of the reader only if there is a transponder in
the detection range of an antenna.




FEIG ELECTRONIC GmbH                                                 Page 27 of 32                                                     M21016-3e-ID-B


OBID i-scan ® UHF       Installation                    ID ISC.LRU3000/3500


Vibration                    EN 60068-2-6
                             10 Hz to 150 Hz: 0,075 mm / 1 g
Shock                        EN 60068-2-27
                             Acceleration 30 g


APPLICABLE STANDARDS


Radio Regulation

• Europe                     EN 302 208
• USA                        FCC 47 CFR Part 15
• Canada                     IC RSS-Gen, RSS-210

EMC                          EN 301 489
Safety
• Low Voltage                EN 60950
• Human Exposure             EN 50364




FEIG ELECTRONIC GmbH   Page 28 of 32                           M21016-3e-ID-B


OBID i-scan ® UHF                          Installation                     ID ISC.LRU3000/3500



7. Radio Approvals

7.1. Europe (CE)
When properly used this radio equipment conforms to the essential requirements of Article 3 and
the other relevant provisions of the R&TTE Directive 1999/5/EC of March 99.




               Performance Classification according to ETSI EN 301 489: Class 2




FEIG ELECTRONIC GmbH                     Page 29 of 32                            M21016-3e-ID-B


OBID i-scan ® UHF                      Installation              ID ISC.LRU3000/3500



7.2. Declaration of Conformity (Directive 1999/5/EC - R&TTE)




                          Figure 21: Declaration of Conformity

FEIG ELECTRONIC GmbH                  Page 30 of 32                  M21016-3e-ID-B


OBID i-scan ® UHF                         Installation                         ID ISC.LRU3000/3500


7.3. USA (FCC) and Canada (IC)

7.3.1. USA (FCC) and Canada (IC) warning notices


      Product name:                            ID ISC.LRU3000-FCC
                                               ID ISC.LRU3500-FCC

      Reader name:                             ID ISC.LRU3000-FCC
                                               ID ISC.LRU3500-FCC

             FCC ID:                               PJMLRU3000
                 IC:                              6633A-LRU3000

 Notice for USA and     This device complies with Part 15 of the FCC Rules and with
      Canada            RSS-210 of Industry Canada.
                        Operation is subject to the following two conditions.
                        (1) this device may not cause harmful interference, and
                        (2) this device must accept any interference received,
                        including interference that may cause undesired operation.
                        Unauthorized modifications may void the authority granted under
                        Federal communications Commission Rules permitting the operation
                        of this device.
                        This equipment has been tested and found to comply with the limits for
                        a Class A digital device, pursuant to Part 15 of the FCC Rules. These
                        limits are designed to provide reasonable protection against harmful
                        interference when the equipment is operated in a commercial
                        environment. This equipment generates, uses, and can radiate radio
                        frequency energy and, if not installed and used in accordance with the
                        instruction manual, may cause harmful interference to radio
                        communications. Operation of this equipment in a residential area is
                        likely to cause harmful interference in which case the user will be
                        required to correct the interference at his own expense.
                        Le présent appareil est conforme aux CNR d'Industrie Canada appli-
                        cables aux appareils radio exempts de licence. L'exploitation est auto-
                        risée aux deux conditions suivantes :
                        (1) l'appareil ne doit pas produire de brouillage, et
                        (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique
                        subi, même si le brouillage est susceptible d'en compromettre le fonc-
                        tionnement.


Warning: Changes or modification made to this equipment not expressly approved by
FEIG ELECTRONIC GmbH may void the FCC authorization to operate this equipment.




FEIG ELECTRONIC GmbH                    Page 31 of 32                                M21016-3e-ID-B


OBID i-scan ® UHF                                Installation                          ID ISC.LRU3000/3500



7.3.2. Label Information
The following information must be placed at the outer side of the housing in which the reader is
mounted.

Contains FCC ID PJMLRU3000
Contains IC: 6633A-LRU3000



7.3.3. Installation with FCC / IC Approval
FCC-/IC-NOTICE: To comply with FCC Part 15 Rules in the United States / with IC Radio Stand-
ards in Canada, the system must be professionally installed to ensure compliance with the Part 15
certification / IC certification. It is the responsibility of the operator and professional installer to en-
sure that only certified systems are deployed in the United States / Canada.




7.3.4. USA (FCC) and Canada (IC) approved antennas
This radio transmitter (identify the device by certification number, or model number if Category II)
has been approved by Industry Canada to operate with the antenna types listed below with maxi-
mum permission gain and required antenna impedance for each antenna type indicated. Antenna
types, not included in this list, having a gain greater than the maximum gain indicated for that type,
are strictly prohibited for use with this device
Le présent émetteur radio (identifier le dispositif par son numéro de certification ou son numéro de
modèle s’il fait partie du matériel de catégorie I) a été approuvé par Industrie Canada pour fonc-
tionner avec les types d’antenne ’énoncé ci-dessus et ayant un gain admissible maximal et
l’impédance requise pour chaque type d’antenne. Les types d’antenne non inclus dans cette liste,
ou dont le gain est supérieur au gain maximal indiqué, sont strictement interdits pour l’exploitation
de l’émetteur
Following antennas are approved by FCC according FCC Part 15 and IC Canada according
RS210
    •   ID ISC.ANT.U170/170-FCC (4.0 dBic)
    •   ID ISC.ANT.U270/270-FCC (9.0 dBic)
    •   ID ISC.ANT.U600/270-FCC (10,5 dBic)




FEIG ELECTRONIC GmbH                            Page 32 of 32                                M21016-3e-ID-B



Document Created: 2013-10-29 11:50:57
Document Modified: 2013-10-29 11:50:57

© 2025 FCC.report
This site is not affiliated with or endorsed by the FCC