User Manual Reader

FCC ID: PJMLRU1002A

Users Manual

Download: PDF
FCCID_4433608

INSTALLATION



ID ISC.LRU1002 (EU: 4127.001.00; FCC: 4128.001.00)
UHF Long Range Reader




final – public (B)
2019-09-04 – M61110-5e-ID-B.docx


IDENTIFICATION                                      Installation                                 ID ISC.LRU1002


                                                    Note
 Copyright 2017-2019 by
         FEIG ELECTRONIC GmbH
         Lange Strasse 4
         D-35781 Weilburg
         Tel.: +49 6471 3109-0
         http://www.feig.de
With the edition of this document, all previous editions become void. Indications made in this manual may be
changed without previous notice.

Copying of this document, and giving it to others and the use or communication of the contents thereof are
forbidden without express authority. Offenders are liable to the payment of damages. All rights are reserved in
the event of the grant of a patent or the registration of a utility model or design.

Composition of the information in this document has been done to the best of our knowledge. FEIG
ELECTRONIC GmbH does not guarantee the correctness and completeness of the details given in this manual
and may not be held liable for damages ensuing from incorrect or incomplete information. Since, despite all
our efforts, errors may not be completely avoided, we are always grateful for your useful tips.
The instructions given in this manual are based on advantageous boundary conditions. FEIG ELECTRONIC
GmbH does not give any guarantee promise for perfect function in cross environments and does not give any
guaranty for the functionality of the complete system which incorporates the subject of this document.
FEIG ELECTRONIC call explicit attention that devices which are subject of this document are not designed
with components and testing methods for a level of reliability suitable for use in or in connection with surgical
implants or as critical components in any life support systems whose failure to perform can reasonably be
expected to cause significant injury to a human. To avoid damage, injury, or death, the user or application
designer must take reasonably prudent steps to protect against system failures.
FEIG ELECTRONIC GmbH assumes no responsibility for the use of any information contained in this docu-
ment and makes no representation that they free of patent infringement. FEIG ELECTRONIC GmbH does not
convey any license under its patent rights nor the rights of others.




FEIG ELECTRONIC GmbH                               Page 2 of 31                            M61110-5e-ID-B.docx


IDENTIFICATION                                                  Installation                                              ID ISC.LRU1002


                                                            Contents

1. Safety Instructions / Warning - Read before start-up !                                                                                  5

2. Performance Features of Reader Family ID ISC.LRU1002                                                                                    6

  2.1. Performance features ........................................................................................................ 6

  2.2. Available reader types....................................................................................................... 6


3. Installation                                                                                                                            7

4. Terminals                                                                                                                               8

  4.1. Antenna Connection ......................................................................................................... 9

  4.2. Power Supply................................................................................................................... 10
      4.2.1. Power Supply via connection X2 ................................................................................ 10

  4.3. Interfaces ......................................................................................................................... 11
      4.3.1. Ethernet Interface on connector X1 ............................................................................ 11
      4.3.2. USB Mini Interface on connector X3 .......................................................................... 11
            4.3.2.1. USB-Stick Service-Functions ......................................................................... 11
            4.3.2.2. Reading of Log and Service Data................................................................... 12
            4.3.2.3. Storing the reader configuration on a USB flash drive .................................... 12
            4.3.2.4. Copy the configuration onto the reader (Config-Cloning) ................................ 13
      4.3.3. RS232 Interface on connector X4 .............................................................................. 14
      4.3.4. Data-Clock Interface on connector X4 ........................................................................ 15

  4.4. Inputs and Outputs on connector X4 ............................................................................. 17
      4.4.1. 24 V DC voltage on connector X4 .............................................................................. 17
      4.4.2. Digital Inputs on connector X4 ................................................................................... 18
      4.4.3. Digital outputs on connector X4 ................................................................................. 19
      4.4.4. Relay output on connector X4 .................................................................................... 20


5. Operating and Display Elements                                                                                                         21

  5.1. Status LED ....................................................................................................................... 21

  5.2. Reset Push Button T1 ..................................................................................................... 22

  5.3. Reader Power Adjustment .............................................................................................. 23

FEIG ELECTRONIC GmbH                                           Page 3 of 31                                       M61110-5e-ID-B.docx


IDENTIFICATION                                                 Installation                                             ID ISC.LRU1002

      5.3.1. EU reader according to EN302 208............................................................................ 23
      5.3.2. FCC-Reader according to FCC 47 Part 15 ................................................................. 24


6. Technical Data                                                                                                                      25

7. Radio Approvals                                                                                                                     28

  7.1. Europe (CE)...................................................................................................................... 28

  7.2. USA (FCC) and Canada (IC) ............................................................................................ 29
      7.2.1. USA (FCC) and Canada (IC) warning notices ............................................................ 29
      7.2.2. Label Information ....................................................................................................... 30
      7.2.3. Installation with FCC / IC Approval ............................................................................. 30
      7.2.4. USA (FCC) and Canada (IC) approved antennas ...................................................... 30


ANNEX A - Accessories                                                                                                                  31




FEIG ELECTRONIC GmbH                                          Page 4 of 31                                     M61110-5e-ID-B.docx


IDENTIFICATION                                  Installation                              ID ISC.LRU1002


1. Safety Instructions / Warning - Read before start-up !

   The device may only be used for the intended purpose designed by for the manufacturer.
   The operation manual should be conveniently kept available at all times for each user.
   Unauthorized changes and the use of spare parts and additional devices which have not been
    sold or recommended by the manufacturer may cause fire, electric shocks or injuries. Such
    unauthorized measures shall exclude any liability by the manufacturer.
   The liability-prescriptions of the manufacturer in the issue valid at the time of purchase are valid
    for the device. The manufacturer shall not be held legally responsible for inaccuracies, errors,
    or omissions in the manual or automatically set parameters for a device or for an incorrect
    application of a device.
   Repairs may only be executed by the manufacturer.
   Installation, operation, and maintenance procedures should only be carried out by qualified
    personnel.
   Use of the device and its installation must be in accordance with national legal requirements and
    local electrical codes .
   When working on devices the valid safety regulations must be observed.
   This device is not suitable to be used in places where children are present. Prevent children
    access to the device.
   Equipment is intended for use only in restricted access area.
   Special advice for carriers of cardiac pacemakers:
    Although this device doesn't exceed the valid limits for electromagnetic fields you should keep a
    minimum distance of 34 cm between the device and your cardiac pacemaker and not stay in an
    immediate proximity of the device respective the antenna for some time.




FEIG ELECTRONIC GmbH                           Page 5 of 31                         M61110-5e-ID-B.docx


IDENTIFICATION                              Installation                           ID ISC.LRU1002


2. Performance Features of Reader Family ID ISC.LRU1002

2.1. Performance features

The reader has been developed for reading passive data carriers, so-called „Smart Labels“, using
an operating frequency in the UHF range. The output power is configurable in the range between
100 mW and 2 W. This allows read ranges of up to 12 m.



2.2. Available reader types
The following readers are available:


Table 1: Available Reader Types

Order Number      Reader type              Description

4127.001.00       ID ISC.LRU1002-EU        Device version for Europe

4128.001.00       ID ISC.LRU1002-FCC       Device version for North America

4861.000.00       ID ISC.LRU1002-MA        Device version for Morocco




FEIG ELECTRONIC GmbH                       Page 6 of 31                       M61110-5e-ID-B.docx


IDENTIFICATION                              Installation                           ID ISC.LRU1002


3. Installation

The Reader is designed for wall-mount, including outdoors. Outdoors the reader should be mounted
like shown in the picture below to ensure the watertightness of the device.
Holes for mounting on a wall with countersunk head screws are provided in the housing. The
maximum head screw diameter should not exceed 8,0 mm. The thread diameter is 5,3 mm (M5
screws). The screws must have a minimum length of 45 mm depending on the installation situation.
It is not necessary to open the reader housing for installation.




                                 Figure 1: Installation Drawing




FEIG ELECTRONIC GmbH                       Page 7 of 31                      M61110-5e-ID-B.docx


IDENTIFICATION                                       Installation                                     ID ISC.LRU1002


4. Terminals

On the lower side of the reader housing different connectors are positioned. Figure 2 shows the
arrangement of the connectors and Table 2: Connection terminals gives an overview on the available
interfaces and signals. Table 3: Push button function shows the available push buttons.




               X1         X2    X3           X4                              ANT 1 - 4       T1




                                      Figure 2: Connection Overview


Table 2: Connection terminals

            Connector      Description

             ANT 1-4       Connection of the external antennas (Impedance 50)

                X1         10/100Tbase network connection with RJ-45

                X2         Power supply 24VDC ± 20%

                X3         USB Mini Interface

                X4         Digital input, digital output, relay output and RS232 interface



Table 3: Push button function

               Push button        Description

                     T1           Internal push button for complete configuration reset




FEIG ELECTRONIC GmbH                                 Page 8 of 31                                 M61110-5e-ID-B.docx


IDENTIFICATION                                Installation                                 ID ISC.LRU1002


4.1. Antenna Connection
The external SMA antenna connectors are positioned on the lower side of the reader.
The maximum tightening torque for the SMA sockets is 0.45 Nm (4.0 lbf in).
For supplying a DC voltage to external components e.g. the UHF antenna multiplexer ID
ISC.ANT.UMUX, it is possible to enable a supply voltage (24 V DC / max. 500mA) on the antenna
cable. This need to be configured in the reader.




Table 4: External antenna connection

          Terminal                                    Description

          ANT 1 - 4               Connection for external antennas (input impedance 50)




                         Figure 3: External antenna connection ANT1-4




CAUTION:
Exceeding the tightening torque will destroy the plug.
The activation of the DC voltage on the antenna cable can damage the antennas from other
manufacturers. It is recommend to use high resistance UHF antennas. For any further ques-
tions please contact the technical support.




FEIG ELECTRONIC GmbH                          Page 9 of 31                            M61110-5e-ID-B.docx


IDENTIFICATION                                        Installation                                 ID ISC.LRU1002


4.2. Power Supply

4.2.1. Power Supply via connection X2
The supply voltage of 24 V DC has to be connected to Terminal X2.




                         Figure 4: Connector X2 Pin assignment for power supply




Table 5: Pin assignment for power supply

        Terminal          Abbreviation                           Description

        X2 / Pin 1            VDC             Supply voltage 24 V DC ±20 %

        X2 / Pin 2            GND             Ground – supply voltage




CAUTION:
The reader has to be supplied by a limited power supply according EN 62368-1 Chapter Q.1,
or with a NEC Class 2/LPS certified power supply.
Each reader has to be supplied by a separate external power supply.
Reversing the polarity of the supply voltage on X2 may destroy the device.
External wiring for the power supply must fulfil the following norms/validation procedure:
                     Conductor Cross-section                            Validation procedure

                     from 0,5 mm2 or bigger                   IEC 60332-1-2 and IEC 60332-1-3

                       smaller than 0,5 mm2                   IEC 60332-2-1 and IEC 60332-2-2




FEIG ELECTRONIC GmbH                                Page 10 of 31                              M61110-5e-ID-B.docx


IDENTIFICATION                                 Installation                              ID ISC.LRU1002


4.3. Interfaces

4.3.1. Ethernet Interface on connector X1
The Reader has an integrated 10 / 100 base-T network port for an RJ-45. Connection is made on
X1 and has an automatic “Crossover Detection” according to the 100BASE-T Standard.
With structured cabling STP CAT 5 cables should be used. This ensures a reliable operation at
10 Mbps or 100 Mbps.
The prerequisite for using TCP/IP protocol is that each device has a unique IP address on the net-
work. All Readers have a factory set IP address.
Table 6: Standard factory configuration of the Ethernet connection

                                 Network                       Address

                    IP-Adresse                             192.168.10.10
                    Subnet-Mask                               255.255.0.0

                    Port                                        10001

                    DHCP                                         OFF

NOTE:
The reader is equipped with a DHCP ready Ethernet Interface.



4.3.2. USB Mini Interface on connector X3
The reader is equipped with a USB on-the-go interface. This can either be used to connect the reader
to a host system or by means of a special on-the-go adaptor for connection of a USB memory stick
to the reader. In both cases the connection is carried out via terminal X3. The pinout is standardized.




                           Figure 5: USB-Interface for host communication


A standard shielded USB-cable can be used for connection of the reader to a host system. The
data rate is reduced to 12 Mbit (USB full speed).
NOTE:
The length of the USB-cable can have a max. of 5m (200 inch). It is not allowed to use longer
cables.

4.3.2.1. USB-Stick Service-Functions

FEIG ELECTRONIC GmbH                          Page 11 of 31                        M61110-5e-ID-B.docx


IDENTIFICATION                                Installation                            ID ISC.LRU1002

Via an optionally available USB On-The-Go adapter cable, the interface can be converted to a
USB host interface. The adapter cable allows the connection of a USB memory stick to the reader.
By means of the USB stick various service functions can be carried out e.g. the read-out of log and
service files and uploading of a configuration file.




                             Figure 6: USB On-The-Go adapter cable


4.3.2.2. Reading of Log and Service Data
After plug-in of the USB flash drive on the running ID ISC.LRU1002 the reader will generate a sub-
directory on the root directory of the USB flash drive. The name of the subdirectory is equal to the
Device-ID of the connected reader (see type plate of the reader). Within this subdirectory the
reader stores device information like firmware version and IP-address in the file INFO.LOG. If there
exist already such a file for the same reader the file will be updated with the information and the
current date and time.
Additionally the files ACTION.LOG and SERVICE.LOG will be generated and stored for service
purposes on the USB flash drive. The meaning of the CONFIG.INI will be described in the next
chapter.
After plug-in of the USB flash drive the green and red status LED of the ID ISC.LRU1002 are per-
manently lit as long as the USB flash drive is actively used by the reader. When the USB actions
are completed successfully, the red LED is switched off and the green LED starts flashing. The
USB flash drive can be removed after the red LED is switched off. If the USB actions failed the red
status LED starts flashing until the USB flash drive is removed.
NOTE:
       After plug-in of the USB flash drive the status LEDs of the reader shall be monitored.
       The USB flash drive shall only be removed from the reader if the USB actions have
        been completed and the flash drive is not in use anymore.
       The USB On-The-Go adapter cable may only be used in conjunction with a USB
        memory stick. When used for a PC connection, the reader can be destroyed!



4.3.2.3. Storing the reader configuration on a USB flash drive


FEIG ELECTRONIC GmbH                        Page 12 of 31                       M61110-5e-ID-B.docx


IDENTIFICATION                                  Installation                              ID ISC.LRU1002

While connecting the USB flash drive on a running reader, the reader will store the configuration as
a editable and readable CSV-file (CONFIG.INI) on the USB flash drive. This file will be stored in
the main directory for easy coping of the configuration (4.3.2.4. Copy the configuration onto the
reader (Config-Cloning)). Additionally the same file will be stored in the subdirectory named after
the according Device-ID (see type plate of the reader). Thereby it is possible to store several con-
figuration files on the same USB flash drive.
All not locked configuration pages (CFG pages) including the interface parameter will be copied from
the reader onto the USB flash drive. Password protected configuration pages will not be copied.
After plug-in of the USB flash drive the green and red status LED are permanently lit as long as the
USB flash drive is actively used by the reader. When the USB actions are completed successfully,
the red LED is switched off and the green LED starts flashing. The USB flash drive can be re-
moved after the red LED is switched off. If the USB actions failed the red status LED starts flashing
until the USB flash drive is removed.
Note:
If there exists already a configuration file CONFIG.INI on the main directory of the USB flash
drive, the old file will be overwritten by the new configuration file.
Configuration pages which are protected by a password (see CFG0) will be not stored on
the USB flash drive. No error message will appear.
After connecting the USB flash drive on the reader USB port, the reader LEDs should be ob-
served.
The USB flash drive shall only be removed from the reader if the USB actions have been
completed and the flash drive is not in use anymore.

4.3.2.4. Copy the configuration onto the reader (Config-Cloning)
In order to connecting the USB flash drive on the reader USB port and copy the configuration from
the USB flash drive onto the reader, it is necessary to switch off the reader before plug-in the USB
flash drive. After switching on the reader the boot process will look for a connected USB flash drive
and will copy the existing configuration file onto the reader.
It must be ensured that no configuration page (CFG page) is locked inside the reader. If configura-
tion pages are locked the configuration file will not be copied onto the reader. If single configuration
parameters in the configuration file were out of range and invalid the configuration file will not be
copied onto the reader as well.
After the copy process has been finished the green LED will start flashing and the red LED goes
off. After the red LED goes off the USB flash drive can be disconnected. If the USB actions failed
the red status LED starts flashing until the USB flash drive is removed.
Note:
Connecting an USB flash drive on a running reader will always overwrite an existing config-
uration file in the main directory on the USB flash drive (see 4.3.2.3. Storing the reader con-
figuration on a USB flash drive).




FEIG ELECTRONIC GmbH                          Page 13 of 31                         M61110-5e-ID-B.docx


IDENTIFICATION                              Installation                          ID ISC.LRU1002


4.3.3. RS232 Interface on connector X4
The RS232 interface is connected on X4. The transmission parameters can be configured by means
of software protocol.




                            Figure 7: RS232 interface pin-outs on X4


Table 7: Pin Assignment RS232 Interface
                       Pin Number
                                                   Pin Assignment
                     at Connector X4
                           1                        RS232 – RxD
                           2                        RS232 – TxD

                           3                               GND




       Figure 8: Wiring example for connecting the RS232 interface to a 9 pin D-SUB plug




FEIG ELECTRONIC GmbH                       Page 14 of 31                     M61110-5e-ID-B.docx


IDENTIFICATION                                 Installation                          ID ISC.LRU1002


4.3.4. Data-Clock Interface on connector X4

The connection of the data-clock interface takes place via the digital Outputs OUT1 and OUT2 at
connector X4. The wire for the clock (Data-0) needs to be connected to connector OUT1-E, the wire
for the data (Data-1) needs to be connected to connector OUT2-E.




                          Figure 9: Data-Clock Interface on connector X4


Table 8: Pin Assignment Data/Clock Interface
                        Pin Number
                                                      Pin Assignment
                      at Connector X4
                            7                          Clock / Data-0
                            8                                 Vcc

                            9                          Data / Data-1

                            10                                Vcc




NOTE:
The data-clock interface is only available in Scan-Mode.
The data-clock interface cannot be used to configure the reader.
The digital outputs OUT1 and OUT2 are not available, if the data-clock interface is activated.
The data as well as the clock need to be supplied with an external voltage. The output is
designed for max. 24 V DC / 20 mA.
For access control application it is possible to connect the reader parallel with two inputs of
a Wiegand controller. By that it is possible to control two traffic lanes (e.g. Entrance and Exit).
Please read the application note N61011-xe-ID-B for more details.




FEIG ELECTRONIC GmbH                        Page 15 of 31                      M61110-5e-ID-B.docx


IDENTIFICATION                              Installation                         ID ISC.LRU1002




              See Notes below for
                resistor values




                                    Figure 10: Wiring Example


NOTE:
Please consider possible limitations of the Wiegand Controller regarding the used supply
voltage.
The necessity of the external pull down resistor is depending on the inner circuit of the used
Wiegand Controller
In dependency on the inner circuit of the used Wiegand Controller it is necessary to use
external serial resistors to limit the current on the data and clock wires.




FEIG ELECTRONIC GmbH                       Page 16 of 31                   M61110-5e-ID-B.docx


IDENTIFICATION                                Installation                            ID ISC.LRU1002


4.4. Inputs and Outputs on connector X4

4.4.1. 24 V DC voltage on connector X4
A 24 V DC voltage can be received on Pin 4 of connector X4. It can be used e.g. to drive the digital
Inputs and Outputs of the reader.




                                    Figure 11: 24 V DC Voltage


Table 9: Pin Assignment 24 V DC Voltage
                        Pin Number                   Pin Assignment
                      at Connector X4
                            3                                GND
                            4                           24 V DC




CAUTION:
The maximum current is limited to 750 mA.




FEIG ELECTRONIC GmbH                         Page 17 of 31                      M61110-5e-ID-B.docx


IDENTIFICATION                                 Installation                               ID ISC.LRU1002


4.4.2. Digital Inputs on connector X4

The optocouplers on Terminal X4 are galvanically isolated from the Reader electronics and must
therefore be externally supplied.




                                 Figure 12: Digital inputs IN1 / IN2


Table 10: Pin Assignment digital Inputs IN1 / IN2
                        Pin Number                    Pin Assignment
                      at Connector X4
                            11                                IN1 -
                            12                             IN1 +

                            13                                IN2 -
                            14                             IN2 +




                Figure 13: Internal and external wiring of the digital inputs IN1 / IN2


NOTE:
The inputs are configured for a input voltage of 12 - 24 V DC and an input current of max. 20
mA.
Polarity reversal or overload on the input will destroy it.



FEIG ELECTRONIC GmbH                          Page 18 of 31                        M61110-5e-ID-B.docx


IDENTIFICATION                                  Installation                            ID ISC.LRU1002


4.4.3. Digital outputs on connector X4

The transistor connections, collector and emitter, of the optocoupler output are galvanically isolated
from the Reader electronics and are carried to the outside without any internal ancillary circuitry on
Terminal X4. The output must therefore be powered by an external power supply.




                                 Figure 14: Digital outputs OUT1 / OUT2


Table 11: Pin Assignment digital outputs OUT1 / OUT2
                        Pin Number                     Pin Assignment
                      at Connector X4
                             7                            OUT1-E
                             8                            OUT1-C

                             9                            OUT2-E

                            10                            OUT2-C




             Figure 15: Internal and external wiring of the digital outputs OUT1 / OUT2


CAUTION:
The output is configured for max. 24 V DC / 20 mA.
Polarity reversal or overload on the output will destroy it.
The output is intended for switching resistive loads only.


FEIG ELECTRONIC GmbH                           Page 19 of 31                      M61110-5e-ID-B.docx


IDENTIFICATION                                Installation                        ID ISC.LRU1002


4.4.4. Relay output on connector X4

There are 2 relay outputs (normally open) available on connector X4.




                                Figure 16: Relay outputs REL1 / REL2

Table 12: Pin Assignment Relay Outputs REL1 / REL2
                       Pin Number                    Pin Assignment
                     at Connector X4
                            5                           REL1-NO
                            6                          REL1-COM

                           15                           REL2-NO

                           16                          REL2-COM

CAUTION:
The relay outputs are configured for max. 24 V DC / 2 A constant load.
The switching current must not exceed 1A.
The relay outputs are intended for switching resistive loads only. If an inductive load is con-
nected, the relay contacts must be protected by means of an external protection circuit.




                          Figure 17: External wiring of the relay outputs




FEIG ELECTRONIC GmbH                         Page 20 of 31                  M61110-5e-ID-B.docx


IDENTIFICATION                                      Installation                                        ID ISC.LRU1002


5. Operating and Display Elements

5.1. Status LED
Table 13: Configuration of the LED

              Host
                                         Warning
          Communication                                                                  Antenna 1- 4


            RUN




       Green         Yellow     Red                                       Description

       FLASH           -        OFF          Normal Reader operation
       FLASH         FLASH      OFF          Reader receives a valid protocol from host
       FLASH           -            ON       RF Warning [0x84]
       FLASH                   FLASH         Hardware Warning; perform Reader Diagnostic [0x6E] for
        (alternat-     -        (alternat-
           ing)                    ing)       further information

     Firmware Update:
       FLASH         FLASH     FLASH         Firmware transfer from host to reader
                                               (Please do not switch off the reader or disconnect the interface cable)
              (light in sequence)
     Configurations-Reset:
       FLASH         FLASH     FLASH
                                             While T1 is pushed and hold for maximal 5 s
              (light in sequence)
                                             After T1 has been pushed and hold for 5 s complete con-
        ON            ON            ON
                                               figuration reset has been performed
     ANT 1 – 4:
                     Green                   HF Power switched on
                     Blue                    Transponder detected
                      Red                    Antenna impedance error (unequal 50 Ohm)




FEIG ELECTRONIC GmbH                              Page 21 of 31                                  M61110-5e-ID-B.docx


IDENTIFICATION                                Installation                             ID ISC.LRU1002


5.2. Reset Push Button T1
By means of the push button T1 a complete configuration reset can be performed. The push button
is positioned in the middle between the antenna connectors ANT3 and ANT4. Figure 18 shows the
position of the push button. It is located inside the reader housing. To press the reset button T1
you should use a paper clip.
To reset the reader back to factory default push the button for at least 5 s until the 3 status LED
(left side) are switched on continuously. After releasing the push button the reader performs a re-
start.
During a complete configuration reset all parameters of the reader will be reset back to factory de-
fault and need to be configured again.




                             Figure 18: Position of the reset button T1




FEIG ELECTRONIC GmbH                         Page 22 of 31                       M61110-5e-ID-B.docx


IDENTIFICATION                                            Installation                ID ISC.LRU1002


5.3. Reader Power Adjustment
To achieve the optimum reading performance it is necessary to set the reader output power to the
highest allowed value. This depends on the used reader type (EU / FCC) and the regulation in the
country were the reader is used.



5.3.1. EU reader according to EN 302 208
According to the standard EN 302 208 the maximum radiated power is 2 W e.r.p. (Effective Radiated
Power) in countries of the European Union. The in the reader configured output power Pout depends
on the antenna gain in dBi and the attenuation of the antenna cable. If a circular polarized antenna
is used the antenna gain [dBic] can be reduced by 3dB. At a linear polarized antenna the maximum
linear antenna gain [dBi] must be used.
                              POut = Perp - Antenna Gain + Cable loss + 2,1dB**
** Correction Factor to convert the radiated power from e.r.p to e.i.r.p.


For the calculation of the reader output power POut an Excel file „Calc-RF-Power.xls“ can be used.
Available from Feig Electronic GmbH.
Example:




   ** linear antenna = „0“, circular antenna = „1“
                                    Figure 19: Calculation of the output power
In Figure 19 the allowed antenna power is shown for the use of the FEIG standard antenna
ANT.U600/270 –EU and a 6m long Belden H155 coaxial cable.




FEIG ELECTRONIC GmbH                                     Page 23 of 31            M61110-5e-ID-B.docx


IDENTIFICATION                                Installation                                       ID ISC.LRU1002


5.3.2. FCC Reader according to FCC 47 Part 15 and IC RSS-247, Issue 2
According to the FCC approval, Title 47, Part 15 and IC RSS-247, Issue 2 the maximum output
power of the reader is limited to 1 W (30dBm). The maximum radiated power of the antenna should
not increase more than 4 W e.i.r.p. Due to these facts the antenna ID ISC.ANT.U600/270-FCC (7,5
dBi) must be used with at least 5,0 m of cable type Belden H155 (0,3 dB/m) or at least 3,0 m of cable
type RG58 (0,5 dB/m).
The antenna ID ANT.U290/290-FCC must be used with at least 2,0 m of cable type Belden H155
(0,3 dB/m). The antenna ID ANT.U580/290-FCC must be used with at least 6,0 m of cable type
Belden H155 (0,3 dB/m).


                    Antenna Type                            Permitted Cable
               ID ISC.ANT.U600/270-FCC      Min. 5,0 m of cable type Belden H155 (0,3 dB/m) or
                                                 min. 3,0 m of cable type RG58 (0,5 dB/m)
               ID ISC.ANT.U270/270-FCC                             -/-

                 ID ANT.U290/290-FCC         min. 2,0 m of cable type Belden H155 (0,3 dB/m)

                 ID ANT.U580/290-FCC         min. 6,0 m of cable type Belden H155 (0,3 dB/m)




FEIG ELECTRONIC GmbH                         Page 24 of 31                             M61110-5e-ID-B.docx


IDENTIFICATION                                        Installation                                     ID ISC.LRU1002


6. Technical Data

MECHANICAL DATA


Housing                                                     Aluminum powder-coated
Dimension (W x H x D)                                       260 mm x 157 mm x 68 mm
                                                            10.2 inch x 6.2 inch x 2.7 inch
Weight                                                      1,8 kg (4.0 lb)
Protection Class                                            IP 53 (with protection cap IP64)
Colour                                                      RAL 9003 (Signal White)


ELECTRICAL DATA


Power Supply                                                24 V DC ± 20 % (Noise Ripple: max. 150 mV)
Current Consumption                                         max.     3,8 A
                                                            typ.*    1,0 A
                                                            *without the power consumption of an external connected
                                                            device, like a UHF –Multiplexer

Operating Frequency
 EU-Reader                                                 865 MHz to 868 MHz (EN 302 208)
 FCC-Reader                                                902 MHz to 928 MHz (FCC47 Part15)

RF-Power                                                    100 mW up to max. 2 W configurable
                                                            (Tolerance: max. ±3 dB)

Antenna Connection                                          4 x SMA female (50 ), internal Multiplexer,
                                                            configurable with 24 V DC     / max. 500 mA
                                                            on the antenna output
RF-Diagnostic                                               RF-Channel monitoring
                                                            Antenna SWR-monitoring
                                                            Internal Overheating control*
Outputs
 2 x Optocoupler                                           24 V DC          / 20 mA (galvanically isolated)
 2 x Relay (NOC)                                           24 V DC          / 1 A (switching current), (2A con-
                                                            stant load)
Inputs
 2 x Optocoupler                                           max. 12 - 24 V DC            / 20 mA
* Caution: Overheating of the device may result in performance losses. It is recommended to activate the RF of the
reader only if there is a transponder in the detection range of an antenna.



FEIG ELECTRONIC GmbH                                 Page 25 of 31                              M61110-5e-ID-B.docx


IDENTIFICATION                 Installation                           ID ISC.LRU1002


Interfaces                          RS232
                                    USB Mini (USB 2.0; Full Speed; On-The-Go)
                                    Ethernet (10/100 BASE-T; MDI/MDI-X cross
                                    over detection; IPv4)
                                    Wiegand (Scan Mode Schnittstelle)




FUNCTIONAL PROPERTIES


Protocol Modes                      FEIG ISO HOST Mode (Advanced Protocol
                                    Frame)
                                    Buffered Read Mode   Automatic Data
                                    Scan Mode            Buffering and
                                    Notification Mode    Filtering
Supported Transponder Types         EPC Class 1 Generation 2
                                    ISO 18000-6-C (Upgrade Code required)
                                    Further transponder types on request possible
Optical Indicators                  16 LEDs for analyze the operating status and
                                    the connected antennas
Further Features                    Anticollision
                                    Output of RSSI and Phase Angle
                                    RF-Channel monitoring
                                    Support of enciphered transponder communica-
                                    tion
                                    Secure key memory
                                    “Config Cloning“-function
                                    Real-time clock (Battery-buffered)




AMBIENT CONDITIONS


Temperature Range

 Operation                         -25 °C up to +55 °C
 Storage                           -25 °C up to +85 °C

Humidity                            5 % up to 95 % non-condensing
Vibration                           EN 60068-2-6
                                    10 Hz to 150 Hz: 0,075 mm / 1 g
Shock                               EN 60068-2-27
                                    Acceleration 30 g
FEIG ELECTRONIC GmbH          Page 26 of 31                     M61110-5e-ID-B.docx


IDENTIFICATION          Installation                   ID ISC.LRU1002


APPLICABLE STANDARDS


Radio Regulation
 Europe                     EN 302 208
 USA                        FCC 47 CFR Part 15
 Canada                     IC RSS-247, Issue 2

EMC                          EN 301 489
Safety

 Low Voltage                EN 62368-1
 Human Exposure             EN 50364




FEIG ELECTRONIC GmbH   Page 27 of 31               M61110-5e-ID-B.docx


IDENTIFICATION                                  Installation                              ID ISC.LRU1002


7. Radio Approvals

7.1. Europe (CE)
Hereby, FEIG ELECTRONIC GmbH declares that the radio equipment type ID ISC.LRU1002 is in
compliance with Directive 2014/53/EU.
The full text of the EU declaration of conformity is available at the following internet address:
http://www.feig.de/en/downloads-support/declarations-of-conformity.html




                Performance Classification according to ETSI EN 301 489: Class 2




FEIG ELECTRONIC GmbH                          Page 28 of 31                         M61110-5e-ID-B.docx


IDENTIFICATION                             Installation                                    ID ISC.LRU1002


7.2. USA (FCC) and Canada (IC)

7.2.1. USA (FCC) and Canada (IC) warning notices


      Product name:                              ID ISC.LRU1002-FCC

             FCC ID:                                 PJMLRU1002A
                 IC:                                6633A-LRU1002A
  Notice for USA and    This device complies with Part 15 of the FCC Rules and with
       Canada           RSS-210 of Industry Canada.
                        Operation is subject to the following two conditions.
                        (1) this device may not cause harmful interference, and
                        (2) this device must accept any interference received,
                        including interference that may cause undesired operation.
                        Unauthorized modifications may void the authority granted under Federal
                        communications Commission Rules permitting the operation of this device.
                        This equipment has been tested and found to comply with the limits for a
                        Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are
                        designed to provide reasonable protection against harmful interference when
                        the equipment is operated in a commercial environment. This equipment
                        generates, uses, and can radiate radio frequency energy and, if not installed
                        and used in accordance with the instruction manual, may cause harmful
                        interference to radio communications. Operation of this equipment in a
                        residential area is likely to cause harmful interference in which case the user
                        will be required to correct the interference at his own expense.
                        Le présent appareil est conforme aux CNR d'Industrie Canada applicables
                        aux appareils radio exempts de licence. L'exploitation est autorisée aux deux
                        conditions suivantes :
                        (1) l'appareil ne doit pas produire de brouillage, et
                        (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi,
                        même si le brouillage est susceptible d'en compromettre le fonctionnement.



Warning:
Changes or modification made to this equipment not expressly approved by
FEIG ELECTRONIC GmbH may void the FCC authorization to operate this equipment.




FEIG ELECTRONIC GmbH                      Page 29 of 31                             M61110-5e-ID-B.docx


IDENTIFICATION                                  Installation                               ID ISC.LRU1002


7.2.2. Label Information
The following information must be placed at the outer side of the housing in which the reader is
mounted.

 Contains FCC ID PJMLRU1002A
 Contains IC: 6633A-LRU1002A
7.2.3. Installation with FCC / IC Approval
FCC-/IC-NOTICE: To comply with FCC Part 15 Rules in the United States / with IC Radio Standards
in Canada, the system must be professionally installed to ensure compliance with the Part 15 certi-
fication / IC certification. It is the responsibility of the operator and professional installer to ensure
that only certified systems are deployed in the United States / Canada.

7.2.4. USA (FCC) and Canada (IC) approved antennas
This radio transmitter (identify the device by certification number, or model number if Category II)
has been approved by Industry Canada to operate with the antenna types listed below with maximum
permission gain and required antenna impedance for each antenna type indicated. Antenna types,
not included in this list, having a gain greater than the maximum gain indicated for that type, are
strictly prohibited for use with this device.
The antennas used for this transmitter must be installed to provide a separation distance of at least
34 cm from all persons and must not be located or operating in conjunction with any other antenna
or transmitter, except as listed for this product's certification.
Le présent émetteur radio (identifier le dispositif par son numéro de certification ou son numéro de
modèle s’il fait partie du matériel de catégorie I) a été approuvé par Industrie Canada pour fonction-
ner avec les types d’antenne ’énoncé ci-dessus et ayant un gain admissible maximal et l’impédance
requise pour chaque type d’antenne. Les types d’antenne non inclus dans cette liste, ou dont le gain
est supérieur au gain maximal indiqué, sont strictement interdits pour l’exploitation de l’émetteur.
Les antennes utilisées pour cet émetteur doit être installé pour fournir une distance de séparation
d'au moins 34 cm de toutes les personnes et ne doit pas être situé ou opérant en conjonction avec
une autre antenne ou un autre émetteur, sauf dans les cas énumérés à la certification de ce produit.
Following antennas are approved by FCC according FCC Part 15 and IC Canada according RS210
      ID ISC.ANT.U270/270-FCC and ID ANT.U290/290-FCC (approx. 6 dBi)
      ID ISC.ANT.U600/270-FCC and ID ANT.U580/290-FCC (approx.. 8–9 dBi)


For operating conditions, see 5.3.2. FCC Reader according to FCC 47 Part 15 and IC RSS-247,
Issue 2.




FEIG ELECTRONIC GmbH                           Page 30 of 31                         M61110-5e-ID-B.docx


IDENTIFICATION                                     Installation                                   ID ISC.LRU1002


ANNEX A - Accessories

Following optional accessories are available:
     Order No.                Article              Description

                                                   Plastic Sealing Cap for Reader Connectors with Steel Conduit
                                                   Pipe Thread (PG) for ID ISC.LRU3x00 and ID ISC.LRU1002
                       ID ISC.LR.CSC-IP64
    3558.000.00
                      Connector Sealing Cap




                        ID ISC.LRU3x00-MS
    3831.000.00      DIN-RAIL mounting kit with    Mounting Rail Set for ID ISC.LRU3x00 and ID ISC.LRU1002
                         self-tapping screws
  EU: 3198.000.00                                  UHF Antenna for connection to UHF Reader, Connector: RG58
                       ID ISC.ANT.U600/270
                                                   coax cable 10 cm, plug SMA – female, 3dB beamwidth 65° x
  FCC: 3685.000.00          UHF Antenna
                                                   30°
  EU: 3199.000.00      ID ISC.ANT.U270/270         UHF Antenna for connection to UHF Reader, Connector: SMA
  FCC: 3686.000.00          UHF Antenna            – female, 3dB beamwidth 65° x 65°
                                                   UHF Antenna for connection to UHF Reader, Connector:
                       ID ISC.ANT.U170/170
  EU: 3200.000.00                                  RG316/U coax cable 10 cm, plug SMA – female, 3dB beam-
                            UHF Antenna
                                                   width 85° x 85°
                                                   Mounting Set for UHF Antenna ID ISC.ANT.U600/270. Suitable
                     ID ISC.ANT.U600/270-MS
    3308.000.00                                    for mounting on installation pipes with a diameter of up to 60
                     Mounting Set Antenna UHF
                                                   mm.
                                                   Mounting Set for UHF Antenna ID ISC.ANT.U270/270. Suitable
                     ID ISC.ANT.U270/270-MS
    3309.000.00                                    for mounting on installation pipes with a diameter of up to 60
                     Mounting Set Antenna UHF
                                                   mm.
                                                   Mounting Set for UHF Antenna ID ISC.ANT.U170/170. Suitable
                     ID ISC.ANT.U170/170-MS
    3310.000.00                                    for mounting on installation pipes with a diameter of up to 60
                     Mounting Set Antenna UHF
                                                   mm.
                       ID ISC.ANT.C2-A UHF         H155 Coax Cable for UHF Reader, Connection Plug SMA -
    1654.002.00
                         Antenna Cable 2m          male/male, Length: approx. 2 m

                       ID ISC.ANT.C6-A UHF         H155 Coax Cable for UHF Reader, Connection Plug SMA -
    1654.003.00
                         Antenna Cable 6m          male/male, Length: approx. 6 m
                                                   Power Supply Unit for ID ISC.LR/LRM2500/1002, ID
                           ID NET.24V-B
    2557.000.00                                    ISC.LRU/LRU3x00/1002. Versatile outlets available (EU, GB,
                         Power Supply Unit
                                                   US - not included).
                      ID CAB.NET.24V-B-EU          Cable with Continental European Plug for Power Supply Unit ID
    2558.000.00
                     Cable with European Plug      NET.24V-B

                      ID CAB.NET.24V-B-GB
    2559.000.00                                    Cable with GB Plug for Power Supply Unit ID NET.24V-B
                      Cable with GB/UK Plug

                      ID CAB.NET.24V-B-US
    2560.000.00                                    Cable with US Plug for Power Supply Unit ID NET.24V-B
                        Cable with US Plug
                        ID CPR.USB/OTG
    4104.000.00       USB Stick + On-The-Go        4 GB USB Flash Drive incl. USB On-The-Go Adapter Cable
                          Adapter Cable




FEIG ELECTRONIC GmbH                              Page 31 of 31                            M61110-5e-ID-B.docx



Document Created: 2019-09-04 14:13:39
Document Modified: 2019-09-04 14:13:39

© 2024 FCC.report