ID CPR74
RFID-Readermodul




                                    Modell      Artikel-Nr..
                              ID CPR74-4SCUSB   4607.000.00
                               ID CPR74-CUSB    4606.000.00




priliminary – public (B)
2016-09-26 – CPR74-Manual   M60610-0e.docx


OBID® classic-pro                                Installation                                           ID CPR74


                                                     Note
 Copyright 2016 by
         FEIG ELECTRONIC GmbH
         Lange Strasse 4
         D-35781 Weilburg
         Tel.: +49 6471 3109-0
         http://www.feig.de

With the edition of this document, all previous editions become void. Indications made in this manual may be
changed without previous notice.

The reproduction, distribution and utilization of this document as well as the communication of its contents to
others without express authorization is prohibited. Offenders will be held liable for the payment of damages.
All rights reserved in the event of the grant of a patent, utility model or design.

Composition of the information in this document has been done to the best of our knowledge. FEIG
ELECTRONIC GmbH does not guarantee the correctness and completeness of the details given in this
manual and may not be held liable for damages ensuing from incorrect or incomplete information. Since,
despite all our efforts, errors may not be completely avoided, we are always grateful for your useful tips.

The instructions given in this manual are based on advantageous boundary conditions. FEIG ELECTRONIC
GmbH does not give any guarantee promise for perfect function in cross environments and does not give
any guaranty for the functionality of the complete system which incorporates the subject of this document.

FEIG ELECTRONIC call explicit attention that devices which are subject of this document are not designed
with components and testing methods for a level of reliability suitable for use in or in connection with surgical
implants or as critical components in any life support systems whose failure to perform can reasonably be
expected to cause significant injury to a human. To avoid damage, injury, or death, the user or application
designer must take reasonably prudent steps to protect against system failures.

FEIG ELECTRONIC GmbH assumes no responsibility for the use of any information contained in this
document and makes no representation that they free of patent infringement. FEIG ELECTRONIC GmbH
does not convey any license under its patent rights nor the rights of others.


OBID® and OBID i-scan® is a registered trademark of FEIG ELECTRONIC GmbH.
All brand names, trademarks or logos are property of their respective owners.




FEIG ELECTRONIC GmbH                              Page 2 of 20                         CPR74-Manual M60610-
                                                                                                     0e.docx


OBID® classic-pro                                            Installation                                                         ID CPR74


                                                             Content

1. Safety Instructions / Warning - Read before start-up !                                                                                   4

2. Characterization ID CPR74                                                                                                                5
  2.1. Scope of delivery..................................................................................................................6
  2.2. Available Accessories .........................................................................................................6
  2.3. Available Software Tools, USB Driver and Firmware .......................................................6


3. Dimensions                                                                                                                               7

4. Installation and wiring                                                                                                                  8
  4.1. Connector X1, X2..................................................................................................................8
  4.2. Digital Outputs......................................................................................................................9
  4.3. Connection of an external Antenna ..................................................................................10
  4.4. SAM Slots............................................................................................................................11
      4.4.1. Installation of a SAM Card in a SAM Socket ................................................................12


5. Power supply                                                                                                                           13
  5.1. Power via USB Interface ....................................................................................................13
  5.2. Standby- / Wake-up-by-Card-Mode ...................................................................................13


6. Indicators / LEDs                                                                                                                      14

7. Installation notes                                                                                                                     15
  7.1. Metallic surroundings ........................................................................................................15
  7.2. EMC effects on cables .......................................................................................................15
  7.3. EMC effects from magnetic fields.....................................................................................16


8. Technical Data                                                                                                                         17

9. Approvals                                                                                                                              19
  9.1. Europa (CE).........................................................................................................................19
  9.2. USA (FCC) and Canada (IC)...............................................................................................20



FEIG ELECTRONIC GmbH                                          Page 3 of 20                                   CPR74-Manual M60610-
                                                                                                                           0e.docx


OBID® classic-pro                        Installation                                  ID CPR74



1. Safety Instructions / Warning - Read before start-up !
   The device may only be used for the intended purpose designed by for the
    manufacturer.

   The operation manual should be conveniently kept available at all times for each user.
   Unauthorised changes and the use of spare parts and additional devices which have not
    been sold or recommended by the manufacturer may cause fire, electric shocks or
    injuries. Such unauthorised measures shall exclude any liability by the manufacturer.

   The liability-prescriptions of the manufacturer in the issue valid at the time of purchase
    are valid for the device. The manufacturer shall not be held legally responsible for
    inaccuracies, errors, or omissions in the manual or automatically set parameters for a
    device or for an incorrect application of a device.

   Repairs may only be executed by the manufacturer.

   Installation, operation, and maintenance procedures should only be carried out by
    qualified personnel.
   Use of the device and its installation must be in accordance with national legal
    requirements and local electrical codes .
   When working on devices the valid safety regulations must be observed.

   Special advice for carriers of cardiac pacemakers:
    Although this device doesn't exceed the valid limits for electromagnetic fields you
    should keep a minimum distance of 25 cm between the device and your cardiac pace-
    maker and not stay in an immediate proximity of the device respective the antenna for
    some time.




FEIG ELECTRONIC GmbH                      Page 4 of 20                   CPR74-Manual M60610-
                                                                                       0e.docx


OBID® classic-pro                                Installation                                    ID CPR74



2. Characterization ID CPR74

The reader modules ID CPR74 are designed for data exchange (read and write) with passive tran-
sponder according ISO14443 type A and type B, ISO15693, ISO18000-3M3 and are capable for
communication with NFC devices (ISO18092). The small dimensions and the different available
interfaces (RS232-TTL or USB) make it suitable for an easy integration into terminals, housings
and other devices.
The following different types of reader modules are available:
                                     ID CPR74-4SCUSB               ID CPR74-CUSB

Dimensions L x B x H               50 mm x 68 mm x 10 mm       50 mm x 68 mm x 8 mm
Power supply                                        5 V DC ± 5 %
Antenna:
                        internal                                       
                       external                                        
SAM Socket                                  4                            -
Digital outputs                                            3
Interface
   RS232-TTL                                              
   USB full-speed (12Mbit/s)                              



The variant ID CPR74-4SCUSB is equipped with 4 sockets for Security Access Modules (SAM) in
the ID000 format. Because of the SAM current consumption the reader module is designed as
Self-Powered-Device and need a separate power supply. The voltage supply from a USB port is
not sufficient in this case.
Because of their high performance and a wide range of different configuration parameters the
reader modules ID CPR74 is suitable for a lot of applications like eTicketing, ePayment,
eDocument, eMobility and medical devices.
With the help of the integrated antenna multiplexer an external antenna can be used additional to
the internal antenna. In Scan Mode the reader can switch between both antenna automatically.
The implemented SoftCrypto and SAMCrypto high level functions offer a comfortable and fast in-
terface for the access to the encrypted data of an mifare Desfire, mifare Plus or mifare Ultralight
transponder.
The reader module with a corresponding external antenna is ready for a EMVCo Contactless Level
1 certification as well as a VDV-KA certification (corresponding to BSI TR-03105 Part 4) or in the
future CEN/TS 16794 approval.
The certification suitability need to be evaluate for each individual case because of the used ex-
ternal antenna and the installation situation.
The SAM Sockets have been approved according the EMVCo Contact Level 1 and they are eligi-
ble for the certification.




FEIG ELECTRONIC GmbH                              Page 5 of 20                        CPR74-Manual M60610-
                                                                                                    0e.docx


OBID® classic-pro                              Installation                                          ID CPR74



2.1. Scope of delivery
The delivery contains the following parts:

        1 x RFID-Reader module ID CPR74



2.2. Available Accessories
Tab. 1 Available Accessories and spare parts

       Part Number             Part name                                   Description

                                                     50 Ohm Antennae with U.FL-connector for the connection
       3674.000.00       ID ISC.ANT40/30-U.FL-A      on the ID CPR74

                                                     Dimensions: 40 mm x 30 mm

                                                     50 Ohm Antennae with U.FL-connector for the connection
       3673.000.00      ID ISC.ANT100/100-U.FL-A     on the ID CPR74

                                                     Dimensions: 100 mm x 100 mm

                                                     50 Ohm Antenna cable with U.FL connector on both sides
                                                     for the connection of an external antenna on the ID
       3540.000.00          ID ISC.ANT.C05-A         CPR74

                                                     Dimension : 500 mm; Color: black

                                                     USB-cable for the connection of the ID CPR74 on an ex-
       3541.000.00           ID CAB.USB-B            ternal host
                                                     Dimension: 2,75 m




2.3. Available Software Tools, USB Driver and Firmware
The USB driver and the test and configuration tool “ID CPRStart” are available on our Feig down-
load area:
http://www.feig.de/en/downloads-support.html
Username: CPR74
Password : FE900


For firmware updates we are providing a update tool “OBIDFirmwareUpdateTool” and a external
firmware xml-file.




FEIG ELECTRONIC GmbH                           Page 6 of 20                         CPR74-Manual M60610-
                                                                                                  0e.docx


OBID® classic-pro                         Installation                                   ID CPR74



3. Dimensions

The ID CPR74 reader module has been designed for the integration into terminals, printers or
handheld devices and so on.




                                 Figure 1: Dimension (Top View)




                                Figure 2: Dimension (Side View)




FEIG ELECTRONIC GmbH                       Page 7 of 20                    CPR74-Manual M60610-
                                                                                         0e.docx


OBID® classic-pro                           Installation                                     ID CPR74



4. Installation and wiring

4.1. Connector X1, X2
The reader can be connected to a RS232-TTL interface and the power supply by using the multi-
pin connector X1. The multi-pin connector X2 provide the connection for the USB interface. The
device with SAM Sockets is a self-powered USB device which requires a separate power supply.
The following figure 4 and the table shows the assignment of the pins X1 (7pol.) and X2 (5pol.) Typ
“JST PH” RM 2 mm (horizontal).



                                                           1
                                       X2
                                                           5
                                                           1

     Figure 3: Plug „JST PH“           X1
                                                           7



                                                           Figure 4: ID CPR74 - plug and connections


                           Tab. 2 Assignment of the pins on X1 and X2

                              X1
                                         Symbol                ID CPR74
                            Pin-No.
                               1          OUT1             Digital Output 1
                               2          OUT2             Digital Output 2
                               3          OUT3             Digital Output 3
                               4          GND*
                               5          RxD                  RS232-TTL
                               6           TxD                 RS232-TTL
                               7          VCC**            + 5 V DC  5 %
                              X2
                            Pin-No.
                               1        Shielding      USB-Cable Shielding
                               2          GND*
                               3       USB-D PLUS
                               4      USB-D MINUS
                               5          VCC**            + 5 V DC  5 %



* GND are connected internal directly
** VCC are connected internal directly. Feed-In VCC only at one pin! This is especially important if
the reader is connected to a USB port. Please take care!
FEIG ELECTRONIC GmbH                         Page 8 of 20                     CPR74-Manual M60610-
                                                                                            0e.docx


OBID® classic-pro                          Installation                                   ID CPR74


NOTICE:

 Only one host interface can be used at the same time. Using several host interfaces at
  the same time can force malfunctions.
 The reader has to supplied by a limited power supply (e.g. NEC Class 2/LPS power sup-
  ply) according IEC EN 60950-1 chapter 2.5, only
 Use only regulated power supply’s.

 The connection cable (RS232TTL, USB, VCC) should be as short as possible and must be
  shorter than 3 m to reduce the influence of noise.

 Reversing the polarity of the supply voltage may destroy the device.
 Supply voltages outside the specifications may destroy the device.

 If switching power supplies are used with the module, be sure that there is adequate fil-
  tering.

 Noise from the power supply can result in a reduction of the read/write range of the
  module.




4.2. Digital Outputs
The Figure 5 shows the circuit diagram of the digital outputs OUT1 – OUT3. The digital outputs are
intended for the connection of external LED’s.




                           Figure 5: Wiring of digital outputs OUT1...3




FEIG ELECTRONIC GmbH                        Page 9 of 20                    CPR74-Manual M60610-
                                                                                          0e.docx


OBID® classic-pro                            Installation                                         ID CPR74



4.3. Connection of an external Antenna

The ID CPR74 modules are equipped with an internal 50 -antenna and have an addi-
tionally connector for an external 50 -antenna.
In Scan mode it is possible to switch between the two antennas automatically. In the
ISOHost Mode the switching of the antenna can be performed by commands.
The use of the external antenna is configurable in the reader settings.
The connection of the external antenna is possible via the U.FL connector „ANT“. Optional
it is possible to integrate a 2-pin SMD connector (spacing 2,54 mm) on position X6.




                                                                                        X6:
                                                                                        Optionale
                                                                                        2 pol. SMD Stift-
                                                                                        leiste




                                                                                         ANT:
                                                                                         (U.FL)

                          Figure 6: Connection of an external antenna


The technical description and hints for building external 50 -antennas can be taken from
the application note N20901-#d-ID-B.pdf.



           Name                                Description


           ANT      Subminiature – Coaxial connector for an external 50 -antenna
            X6      Optional 2pin. connector for an external 50 -antenna



NOTICE:

   Only for use with 50  matched external antennas. The permanent usage of unmatched
    antennas can damage the reader electronic.

   The antenna output is neither permanent short circuit protected nor permanent no-load
    protected.

   The antenna cable should be no longer than 1m. The use of other cable length are pos-
    sible after consulting the manufacturer.


FEIG ELECTRONIC GmbH                          Page 10 of 20                         CPR74-Manual M60610-
                                                                                                  0e.docx


OBID® classic-pro                         Installation                                  ID CPR74



4.4. SAM Slots
Figure 7 shows the position of the 4 SAM slots (S1-4). Each SAM slot is designed for a ID000
formatted SAM Card.


NOTICE

   Wrong inserted SAM cards and forcefully opening or closing can damage the SAM slot.
    See chapter: 4.4.1. Installation of a SAM Card in a SAM




                            Figure 7: Position of the 4 SAM Sockets




FEIG ELECTRONIC GmbH                      Page 11 of 20                   CPR74-Manual M60610-
                                                                                        0e.docx


OBID® classic-pro                         Installation                                     ID CPR74



4.4.1. Installation of a SAM Card in a SAM Socket


The following step by step instruction shows the installation of a SAM Card into the SAM socket
S1.




1. Closed SAM socket without SAM card.           2. Push the latch to the right side and open the
                                                 cover carefully.




3. Put the SAM card into the cover. The contact 4. The SAM card must be pushed up against
plate face up and the beveled corner outside    the stop angle.




5. The SAM card must not be inserted with the    6. Close the top cover with carefully pressure to
beveled corner first.                            snap into place. Push the latch to the left side.




FEIG ELECTRONIC GmbH                       Page 12 of 20                    CPR74-Manual M60610-
                                                                                          0e.docx


OBID® classic-pro                         Installation                               ID CPR74



5. Power supply

The reader ID CPR74-SCUSB with 4 SAM slots is designed as a “Self-Powered USB Device” and
needs an additional 5 V DC power supply.
The power supply must meet the following specification:
+5 V DC ± 5 %
Ripple:
0...250 kHz < 10 mVpp
from 250 kHz < 0,1 mVpp


Note:

   On both device variants you need to take care that the voltage supply of the USB port is
    not connected in the case if an external power supply is connected.



5.1. Power via USB Interface
The reader ID CPR74-CUSB (without SAM-Sockets) can be optional powered via a High Powered
USB port (500mA).



5.2. Standby- / Wake-up-by-Card-Mode
The Standby mode or the Wake-up-by-Card function can be configured in the reader configura-
tion. See system manual „H60410-xe-ID-B.pdf“.


NOTICE:
 The reader can be set into the Standby mode or the Wake-up-by-Card mode with the
  command 0x64 System Reset, see system manual H60410-xe-ID-B. The command can be
  executed via the RS232-TTL interface only and not via the USB interface.




FEIG ELECTRONIC GmbH                       Page 13 of 20               CPR74-Manual M60610-
                                                                                     0e.docx


OBID® classic-pro                           Installation                                 ID CPR74



6. Indicators / LEDs
The reader modules has two LED indicators on board (green and red)
After power on or after a CPU Reset both LED’s starts blinking synchronously for about 2s.
While operation the LED’s signalizes the following operating status:
LED - green
        flashes:
                   Reader is ready for operation but has no host communication
        shine:
        Polling-Mode:
                 Reader is ready for work and has communication with the host.
        Scan-Mode:
               Reader is working in Scan-Mode.
LED - rot
        Communication with the Transponder (Tag detect).


Figure 8 shows the position of the green and red LED.




                            Figure 8: Position of the green and red LED




FEIG ELECTRONIC GmbH                        Page 14 of 20                  CPR74-Manual M60610-
                                                                                         0e.docx


OBID® classic-pro                            Installation                                      ID CPR74



7. Installation notes

Be aware of the following possible environmental factors when installing an ID CPR74 into another
device :

   Effects from nearby metal objects
     Detuning of the integrated antenna
     Impaired communication of the antenna’s magnetic field

   EMC effects on cables
     Impaired communication between reader and transponder

   EMC effects from magnetic fields
     Impaired communication between reader and transponder



7.1. Metallic surroundings
When installing an ID CPR74 into another device, be sure that there are no metal surfaces or ob-
jects in the direct vicinity of the reader if possible. These can detune the antenna and thus reduce
the magnetic field of the integrated antenna. This will in turn result in reduced read distances for
the reader.
The distance between the reader and a metal surface should be at least 3 cm. Note that
even other circuit boards may act like metal objects depending on how much copper they
contain.
If a metallic surrounding cannot be avoided, stable function should at least be ensured by keeping
the distance as great as possible.
The area between the antenna and transponder as well as the area on the other side of the tran-
sponder should also be kept clear of metal parts.
Since any change in the metallic environment will result in detuning of the integrated antenna and
therefore to impaired function, no moving metal parts, such as metallic fans, should be allowed in
the vicinity of the reader.



7.2. EMC effects on cables
In spite of the internal EMC filters inside the reader, high levels of noise on the supply voltage can
result in impairment of the communication between the reader and transponder.
When installing an ID CPR74 into another device, be sure therefore that a clean, noise-free power
supply is used.




FEIG ELECTRONIC GmbH                         Page 15 of 20                      CPR74-Manual M60610-
                                                                                              0e.docx


OBID® classic-pro                           Installation                                    ID CPR74



7.3. EMC effects from magnetic fields
The communication principle of RFID- Technology is based on the modulation of electromagnetic
fields. Alternating magnetic fields in the vicinity of the antenna can have a negative influence on
the reader function.
Sources of such magnetic interference fields include coils within a primary or secondary switching
power supply.
When determining the position of the reader and antenna within a device, check the device for any
possible sources of interference as described above. If necessary, use shielding to suppress such
interference.




FEIG ELECTRONIC GmbH                        Page 16 of 20                     CPR74-Manual M60610-
                                                                                            0e.docx


OBID® classic-pro                            Installation                                             ID CPR74



8. Technical Data

Tab. 3: Technical data

                                                                       ID CPR74

Weight                                                                approx. 20 g

                                 Operating             -25 °C up to +70 °C (-13 °F up to +158 °F)
Temperature Range
                                 Storage               -40 °C up to +85 °C (-40 °F up to +185 °F)

Humidity                                                       max. 95 % (not condensing)

MTBF                                                                   500 000 h

                                                                       +5 V DC ± 5 %
                                                                           Ripple:
Power Supply
                                                                  0...250 kHz < 10 mVpp
                                                                from 250 kHz < 0,1 mVpp

                                                                < 500 mA (without SAM)
Current Consumption
                                                               Standby-Mode/Sleep-Mode

                    USB                               Full-Speed (12 Mbit/s), Self-Powered Device
Interfaces
                    RS232-TTL                                     4 800 – 230 400 Baud

                                                      OBID® USB Driver, PC/SC-Driver (WHQL)
                                                          Windows® Server 2003 und 2008,
Driver                                              Windows® Vista 32/64 Bit, Windows® 7 32/64 Bit,
                                                     Windows® 8 32/64 Bit, Windows® 10 32/64 Bit,
                                                                    Windows® CE

Software Development Kits                       Windows®, Windows® CE and Linux (C++, .NET, JAVA)

                                                              3 digital outputs; max. 20 mA
I/Os
                                                                   2 LED’s (green, red)

                                                            ISO 14443-A/-B (106 … 848 kBit/s)
RFID Interface
                                                               ISO 15693, ISO 18000-3M3

Operating Frequency                                                    13,56 MHz

Output Power                                                            450 mW

Antenna Connection                                          U.FL-Socket for external antenna

                                                  ISO/IEC 14443-4, mifare® classic, mifare® UltraLight,
                                                  mifare® DESFire, mifare® PLUS, mifare® UltraLight C,
                                                            my-d® move, JewelTM, FeliCa.
Supported Transponder Types (contactless)        Tag-It HFI, Fujitsu MB89R11x, STM24LRx, STMLRI2k,
                                                              I-Code SLI/SLIX, I-Code ILT
                                                 NFC Devices in Card Emulation Mode (Tag Type 1…4),
                                                               NFC Peer-to-Peer (P2P)

                                                   4 SAM-Module (size ID000) according to ISO 7816
Contact Interface
                                                      T=0 and T=1 Protocol, Power Class A, B & C

Operating Modes                                        ISOHost Mode ( Polling Mode), Scan-Mode




FEIG ELECTRONIC GmbH                         Page 17 of 20                           CPR74-Manual M60610-
                                                                                                   0e.docx


OBID® classic-pro                         Installation                                            ID CPR74


                                 Europe                            EN 300 330

Radio Approval                   USA                          FCC 47 CFR Part 15
                                 Canada                            IC RSS-210
EMV                                                                EN 301 489

                                                                    EN 62368
Safety and Health
                                                                    EN 50364

                                                               WEEE - 2002/96/EC
Waste and Hazardous Substances
                                                               RoHS - 2011/65/EC

                                                    Tested according EMVCo Contact Level 1

Miscellaneous                              Certification suitability according EMVCo Contactless Level 1,
                                              VDV-KA,ITSO and in the future CEN/TS 16794 (see chap-
                                                          ter: 2. Characterization ID CPR74)




FEIG ELECTRONIC GmbH                      Page 18 of 20                          CPR74-Manual M60610-
                                                                                               0e.docx


OBID® classic-pro                            Installation                                       ID CPR74



9. Approvals

9.1. Europa (CE)
Hereby, FEIG ELECTRONIC GmbH declares that the radio equipment type ID CPR74 is in com-
pliance with Directive 2014/53/EU.


The full text of the EU declaration of conformity is available at the following internet address:

http://www.feig.de/en/downloads-support/declarations-of-conformity.html




                Performance Classification according to ETSI EN 301 489: Class 2




FEIG ELECTRONIC GmbH                          Page 19 of 20                     CPR74-Manual M60610-
                                                                                              0e.docx


OBID® classic-pro                               Installation                                           ID CPR74



9.2. USA (FCC) and Canada (IC)

  Product name:                                              ID CPR74

           FCC ID:                                         PJMCPR74
                  IC:                                     6633A-CPR74
                          This device complies with Part 15 of the FCC Rules and with
  Notice for USA
                          RSS-210 of Industry Canada.
   and Canada             Operation is subject to the following two conditions.
                          (1) this device may not cause harmful interference, and
                          (2) this device must accept any interference received,
                          including interference that may cause undesired operation.
                          Unauthorized modifications may void the authority granted under Federal
                          communications Commission Rules permitting the operation of this device.
                          This equipment has been tested and found to comply with the limits for a Class A
                          digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
                          provide reasonable protection against harmful interference when the equipment is
                          operated in a commercial environment. This equipment generates, uses, and can
                          radiate radio frequency energy and, if not installed and used in accordance with
                          the instruction manual, may cause harmful interference to radio communications.
                          Operation of this equipment in a residential area is likely to cause harmful
                          interference in which case the user will be required to correct the interference at
                          his own expense.

                          Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux
                          appareils radio exempts de licence. L'exploitation est autorisée aux deux condi-
                          tions suivantes :
                          (1) l'appareil ne doit pas produire de brouillage, et
                          (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi,
                          même si le brouillage est susceptible d'en compromettre le fonctionnement.

Warning: Changes or modification made to this equipment not expressly approved by
FEIG ELECTRONIC GmbH may void the FCC authorization to operate this equipment.




Installation with FCC / IC Approval:
FCC-/IC-NOTICE: To comply with FCC Part 15 Rules in the United States / with IC Radio Stand-
ards in Canada, the system must be professionally installed to ensure compliance with the Part 15
certification / IC certification. It is the responsibility of the operator and professional installer to en-
sure that only certified systems are deployed in the United States / Canada.




FEIG ELECTRONIC GmbH                            Page 20 of 20                         CPR74-Manual M60610-
                                                                                                    0e.docx



Document Created: 2016-09-26 15:06:24
Document Modified: 2016-09-26 15:06:24

© 2025 FCC.report
This site is not affiliated with or endorsed by the FCC