id cpr44 user manual-01

FCC ID: PJMCPR44

Users Manual

Download: PDF
FCCID_3382186

INSTALLATION


ID CPR44
ISO14443-A and -B RFID Reader




final - public (B)
ID CPR44 User Manual-01.doc


OBID® classic-pro                                  Installation                                      ID CPR44


                                                     Note

 Copyright 2010 - 2012 by
         FEIG ELECTRONIC GmbH
         Lange Strasse 4
         D-35781 Weilburg
         Tel.: +49 6471 3109-0
         http://www.feig.de

With the edition of this document, all previous editions become void. Indications made in this manual may be
changed without previous notice.

The reproduction, distribution and utilization of this document as well as the communication of its contents to
others without express authorization is prohibited. Offenders will be held liable for the payment of damages.
All rights reserved in the event of the grant of a patent, utility model or design.

Composition of the information in this document has been done to the best of our knowledge. FEIG
ELECTRONIC GmbH does not guarantee the correctness and completeness of the details given in this
manual and may not be held liable for damages ensuing from incorrect or incomplete information. Since,
despite all our efforts, errors may not be completely avoided, we are always grateful for your useful tips.

The instructions given in this manual are based on advantageous boundary conditions. FEIG ELECTRONIC
GmbH does not give any guarantee promise for perfect function in cross environments and does not give
any guaranty for the functionality of the complete system which incorporates the subject of this document.

FEIG ELECTRONIC call explicit attention that devices which are subject of this document are not designed
with components and testing methods for a level of reliability suitable for use in or in connection with surgical
implants or as critical components in any life support systems whose failure to perform can reasonably be
expected to cause significant injury to a human. To avoid damage, injury, or death, the user or application
designer must take reasonably prudent steps to protect against system failures.

FEIG ELECTRONIC GmbH assumes no responsibility for the use of any information contained in this
document and makes no representation that they free of patent infringement. FEIG ELECTRONIC GmbH
does not convey any license under its patent rights nor the rights of others.


OBID® and OBID i-scan® is a registered trademark of FEIG ELECTRONIC GmbH.
All brand names, trademarks or logos are property of their respective owners.




FEIG ELECTRONIC GmbH                            Page 2 of 16                       ID CPR44 User Manual-
                                                                                                  01.doc


OBID® classic-pro                                              Installation                                                     ID CPR44


                                                            Contents

1. Safety Instructions / Warning - Read before start-up !                                                                                   4

2. Characterization ID CPR44.0x-xx                                                                                                          5

3. Installation and wiring                                                                                                                  6
  3.1. Dimensions ...........................................................................................................................6
  3.2. Connection X1, X2 - Vcc and Interface ...............................................................................7
  3.3. Digital Outputs......................................................................................................................8
  3.4. SAM Module ..........................................................................................................................9
     3.4.1. Installation of a SAM Card ............................................................................................10
  3.5. Installation notes ................................................................................................................11
     3.5.1. Metallic surroundings ....................................................................................................11
     3.5.2. EMC effects on cables ..................................................................................................11
     3.5.3. EMC effects from magnetic fields .................................................................................12


4. Radio Approvals                                                                                                                        13
  4.1. Europe (CE).........................................................................................................................13
  4.2. USA (FCC) and Canada (IC)...............................................................................................14


5. Technical Data                                                                                                                         15




FEIG ELECTRONIC GmbH                                          Page 3 of 16                                ID CPR44 User Manual-
                                                                                                                         01.doc


OBID® classic-pro                          Installation                                ID CPR44



1. Safety Instructions / Warning - Read before start-up !

   The device may only be used for the intended purpose designed by for the
    manufacturer.

   The operation manual should be conveniently kept available at all times for each user.
   Unauthorised changes and the use of spare parts and additional devices which have not
    been sold or recommended by the manufacturer may cause fire, electric shocks or
    injuries. Such unauthorised measures shall exclude any liability by the manufacturer.

   The liability-prescriptions of the manufacturer in the issue valid at the time of purchase
    are valid for the device. The manufacturer shall not be held legally responsible for
    inaccuracies, errors, or omissions in the manual or automatically set parameters for a
    device or for an incorrect application of a device.

   Repairs may only be executed by the manufacturer.

   Installation, operation, and maintenance procedures should only be carried out by
    qualified personnel.
   Use of the device and its installation must be in accordance with national legal
    requirements and local electrical codes .
   When working on devices the valid safety regulations must be observed.

   Special advice for carriers of cardiac pacemakers:
    Although this device doesn't exceed the valid limits for electromagnetic fields you
    should keep a minimum distance of 25 cm between the device and your cardiac pace-
    maker and not stay in an immediate proximity of the device respective the antenna for
    some time.




FEIG ELECTRONIC GmbH                    Page 4 of 16                 ID CPR44 User Manual-
                                                                                    01.doc


OBID® classic-pro                                      Installation                                 ID CPR44



2. Characterization ID CPR44

The reader modules ID CPR44 are designed for data exchange (read and write) with passive tran-
sponder according ISO14443 type A and type B and are capable for communication with NFC de-
vices (ISO18092) and supports the mifare classic security functions. The small dimensions and the
different available interfaces (RS232-TTL or USB) makes it suitable for an easy integration into
terminals, housings and other devices. If the device is connected to an USB host it works as a self-
powered device which requires a separate power supply.


The following different types are available:
                                        CPR44-4SCUSB




                                                                           CPR44-CUSB
Dimensions L x D x H (mm)          50 x 60 x 13,8                     50 x 60 x 7,3
Power supply                                              5 V / DC
SAM Socket                                4                                   -
Digital outputs                                              3
Interface
   RS232-TTL                                                
   USB full-speed (12Mbit/s)                                



ID CPR44-4SCUSB
Reader module with internal antenna. The reader modules ID CPR44-4SCUSB are equipped with
4 sockets for Security Access Modules (SAM) in ID000 format.


ID CPR44-SCUSB
Reader module with internal antenna. The reader modules ID CPR44-SCUSB has no Security Ac-
cess Modules sockets.
Because of their high performance and a wide range of different configuration parameters the
reader modules ID CPR44 is suitable for a lot of applications like access control, ePayment,
eTicketing and public transport..
For further details about configuration parameters and commands please refer to the ID CPR44-
Family manual (H90700-xe-ID-B.pdf).




FEIG ELECTRONIC GmbH                                   Page 5 of 16                     ID CPR44 User Manual-
                                                                                                       01.doc


OBID® classic-pro                                     Installation                        ID CPR44



3. Installation and wiring


3.1. Dimensions
                7,5




                               7,2
                                                 ,5
                                               R1
                           1
         24,8

                  14




                       X2
                                                        J1
                           1
   50
   44




                                                        X6
                                                      ANT
                18




                       X1




                                                                 19,2
                       3                                             7,4                  *
                                     44
                                          60

                           Fig. 2 Top view                                 Fig. 1 Side view
                                                                           (* only types with SAM)




                                 Fig. 3 Button view. Types with SAM




FEIG ELECTRONIC GmbH                              Page 6 of 16             ID CPR44 User Manual-
                                                                                          01.doc


OBID® classic-pro                             Installation                               ID CPR44



3.2. Connection X1, X2 - Vcc and Interface

The reader can be connected to a RS232-TTL interface and the power supply by using the multi-
pin connector X1. The multi-pin connector X2 provide the connection for the USB interface. The
device is a self-powered USB device which requires a separate power supply.
The following figure 5 and the table shows the assignment of the pins X1 (7pol.) and X2 (5pol.) Typ
“JST PH” RM 2 mm (horizontal).




   Fig. 4 Plug „JST PH“




                                                Fig. 5 Plug and connections



                        X1
                                   Symbol             ID CPR44
                      Pin-No.
                          1         OUT1            Digital Output 1
                          2         OUT2            Digital Output 2
                          3         OUT3            Digital Output 3
                          4         GND*
                          5         RxD               RS232-TTL
                          6         TxD               RS232-TTL
                          7        VCC**            + 5 V DC  5 %
                        X2
                      Pin-No.
                          1       Shielding       USB-Cable Shielding
                          2         GND*
                          3      USB-D PLUS
                          4     USB-D MINUS
                          5        VCC**            + 5 V DC  5 %

* GND are connected internal directly
** VCC are connected internal directly. Feed-In VCC only at one pin!


FEIG ELECTRONIC GmbH                          Page 7 of 16                ID CPR44 User Manual-
                                                                                         01.doc


OBID® classic-pro                            Installation                               ID CPR44


NOTICE:

 The reader has to supplied by a limited power supply (e.g. NEC Class 2/LPS power sup-
  ply) according IEC EN 60950, only
 Use only regulated power supply’s.
 The connection cable (RS232TTL, USB, VCC) should be as short as possible and must be
  shorter than 3 m.

 Reversing the polarity of the supply voltage may destroy the device.
 Supply voltages outside the specifications may destroy the device.
 If switching power supplies are used with the module, be sure that there is adequate fil-
  tering.
 Noise from the power supply can result in a reduction of the read/write range of the
  module.



3.3. Digital Outputs

The Fig. 6 shows the circuit diagram of the digital outputs OUT1 – OUT3. The digital outputs are
intended for the connection of external LED’s.




                       Fig. 6 Wiring of digital outputs OUT1...3




FEIG ELECTRONIC GmbH                       Page 8 of 16                 ID CPR44 User Manual-
                                                                                       01.doc


OBID® classic-pro                           Installation                                ID CPR44



3.4. SAM Module

Fig. 8 shows the position of the 2 SAM connector (double stacked) X4 and X5. Each SAM con-
nector is designed for two ID000 formatted (SIM Karte) SAM modules.


NOTICE

     The SAM connectors are designed only for occasional opening and closing cycles.

     Wrong inserted SAM modules and forcefully opening or closing will damage the SAM
      connectors.




    Socket    Position   SAM Number
                top           3
     X4
              button          1
                top           4
     X5
              button          2




                                                           Fig. 7 Position der 4 SAM Module


                         Slot for SAM Card 3 and 4




                Slot for SAM Card 1 and 2




                                  Fig. 8 SAM Modul




FEIG ELECTRONIC GmbH                        Page 9 of 16                  ID CPR44 User Manual-
                                                                                         01.doc


OBID® classic-pro                             Installation                              ID CPR44



3.4.1. Installation of a SAM Card

The following step by step instruction shows the installation of the SAM Card 1 and 3 into the SAM
connector X4. The installation of the SAM Cards 2 and 4 in the socket X5 must be done in the
same way.




1. Unlatch the top cover at the front edge.        2. Push the cover of lower slot backwards and
                                                   open it




3. Put the SAM module 1 into the cover of the      4. Turn down the cover of the lower slot and
lower slot. The contact plate face down            push it forward till the cover is locked.




5. Place the SAM Cart 3 with the contact face at 6. Close the top cover with carefully pressure to
the top on the cover of the lower slot.          snap into place.


FEIG ELECTRONIC GmbH                      Page 10 of 16                  ID CPR44 User Manual-
                                                                                        01.doc


OBID® classic-pro       Installation               ID CPR44




FEIG ELECTRONIC GmbH   Page 11 of 16   ID CPR44 User Manual-
                                                      01.doc


OBID® classic-pro                              Installation                                 ID CPR44



3.5. Installation notes

Be aware of the following possible environmental factors when installing an ID CPR44into another
device :

   Effects from nearby metal objects
     Detuning of the integrated antenna
     Impaired communication of the antenna’s magnetic field

   EMC effects on cables
     Impaired communication between reader and transponder

   EMC effects from magnetic fields
     Impaired communication between reader and transponder



3.5.1. Metallic surroundings

When installing an ID CPR44into another device, be sure that there are no metal surfaces or ob-
jects in the direct vicinity of the reader if possible. These can detune the antenna and thus reduce
the magnetic field of the integrated antenna. This will in turn result in reduced read distances for
the reader.
The distance between the reader and a metal surface should be at least 3 cm. Note that
even other circuit boards may act like metal objects depending on how much copper they
contain.
If a metallic surrounding cannot be avoided, stable function should at least be ensured by keeping
the distance as great as possible.
The area between the antenna and transponder as well as the area on the other side of the tran-
sponder should also be kept clear of metal parts.
Since any change in the metallic environment will result in detuning of the integrated antenna and
therefore to impaired function, no moving metal parts, such as metallic fans, should be allowed in
the vicinity of the reader.



3.5.2. EMC effects on cables

In spite of the internal EMC filters inside the reader, high levels of noise on the supply voltage can
result in impairment of the communication between the reader and transponder.
When installing an ID CPR44 into another device, be sure therefore that a clean, noise-free power
supply is used.




FEIG ELECTRONIC GmbH                       Page 12 of 16                   ID CPR44 User Manual-
                                                                                          01.doc


OBID® classic-pro                            Installation                                  ID CPR44



3.5.3. EMC effects from magnetic fields

The communication principle of RFID- Technology is based on the modulation of electromagnetic
fields. Alternating magnetic fields in the vicinity of the antenna can have a negative influence on
the reader function.
Sources of such magnetic interference fields include coils within a primary or secondary switching
power supply.
When determining the position of the reader and antenna within a device, check the device for any
possible sources of interference as described above. If necessary, use shielding to suppress such
interference.




FEIG ELECTRONIC GmbH                        Page 13 of 16                   ID CPR44 User Manual-
                                                                                           01.doc


OBID® classic-pro                           Installation                              ID CPR44



4. Radio Approvals


4.1. Europe (CE)



When used according to regulation, this radio equipment conforms with the basic requirements of
Article 3 and the other relevant provisions of the R&TTE Guideline 1999/EC dated March 99.




                  Equipment Classification according ETSI EN 300 330: Class 2




FEIG ELECTRONIC GmbH                    Page 14 of 16                  ID CPR44 User Manual-
                                                                                      01.doc


OBID® classic-pro                                 Installation                                         ID CPR44




4.2. USA (FCC) and Canada (IC)

       Product name:                                            ID CPR44

                FCC ID:                                        PJMCPR44
                      IC:                                    6633A-CPR44
                               This device complies with Part 15 of the FCC Rules and with
 Notice for USA and
                               RSS-210 of Industry Canada.
      Canada
                               Operation is subject to the following two conditions.
                               (1) this device may not cause harmful interference, and
                               (2) this device must accept any interference received,
                               including interference that may cause undesired operation.
                               Unauthorized modifications may void the authority granted under Federal
                               communications Commission Rules permitting the operation of this device.
                               This equipment has been tested and found to comply with the limits for a
                               Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are
                               designed to provide reasonable protection against harmful interference when
                               the equipment is operated in a commercial environment. This equipment
                               generates, uses, and can radiate radio frequency energy and, if not installed
                               and used in accordance with the instruction manual, may cause harmful
                               interference to radio communications. Operation of this equipment in a
                               residential area is likely to cause harmful interference in which case the user
                               will be required to correct the interference at his own expense.

                               Le présent appareil est conforme aux CNR d'Industrie Canada applicables
                               aux appareils radio exempts de licence. L'exploitation est autorisée aux deux
                               conditions suivantes :
                               (1) l'appareil ne doit pas produire de brouillage, et
                               (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi,
                               même si le brouillage est susceptible d'en compromettre le fonctionnement.



Warning: Changes or modification made to this equipment not expressly approved by
FEIG ELECTRONIC GmbH may void the FCC authorization to operate this equipment.
Installation with FCC / IC Approval:
FCC-/IC-NOTICE: To comply with FCC Part 15 Rules in the United States / with IC Radio Stand-
ards in Canada, the system must be professionally installed to ensure compliance with the Part 15
certification / IC certification. It is the responsibility of the operator and professional installer to en-
sure that only certified systems are deployed in the United States / Canada.




FEIG ELECTRONIC GmbH                             Page 15 of 16                        ID CPR44 User Manual-
                                                                                                     01.doc


OBID® classic-pro                              Installation                                       ID CPR44



5. Technical Data



Weight                                           approx 20 g

Antenna                                             Internal (48 mm x 58 mm)

Temperature Range                      Operating -25°C to +70°C
                                        Storage -40°C to +85°C

Humidity                                         0 to 95 % not condensing

Power Supply                                      5 V DC  5 %        Ripple:
                                                               0...250 kHz < 10 mVpp
                                                               up from 250 kHz < 0,1 mVpp
                                                               1
Current consumption                              typ. 300 mA

RF Interface                                     ISO14443-A & ISO14443-B (Part 4 fully supported)
                                                 106, 212, 424, 847 kbit/s

Supported Transponder                            mifare classic, mifare Ultralight, mifare Ultralight C,
(reading and writing)                            mifare DESfire, mifare PLUS, Smart MX, my-d proxim-
                                                 ity, SLE44R35S, SLE55R, Jewel, SLE66CL,
                                                 ST19XR34, SRI4K, SRIX4K, SRI512, SR176, RF360,
                                                 etc.
                                                 NFC Type 1, 2 and Type 4 in card emulation mode

Operating Frequency                              13.56 MHz

RF Transmitting Power                            400 mW  2 dB

Host-Interface                                    USB Full-Speed (12 Mbit/s)
                                                     Self-Powered Device
                                                  RS232-TTL (4.800 to 230.400 Baud)

Digital Output                                   3 (Iout high max.: 5 mA / Iout low max.: 8 mA)

Connector
                VCC, RS232TTL, Digital Outputs:  JST PH 7pin. (X1)
                                           USB:  JST PH 5pin. (X2)

Contact Interface (ISO7816)                      4 * SAM Socked for ID000 Format (SIM-Card)
(only types with SAM)                            9600 to 375.000 bit/s
                                                 T=0 and T=1 Protocol
                                                 for 1,8 V; 3 V; 5 V Smartcards

MTBF                                             500.000 h




1
    Current consumption of SAMs excluded
FEIG ELECTRONIC GmbH                       Page 16 of 16                       ID CPR44 User Manual-
                                                                                              01.doc


OBID® classic-pro                 Installation                                  ID CPR44


USB Driver                             PC/SC Driver for Windows
                                       Native OBID® USB Driver for Windows
                                     Windows® CE for different platforms on request

Operating Modes                     Polling-Mode

EEPROM (for Parameter)              1 * 106 write cycles

FLASH (for Firmware)                (Firmware update in Application possible)


                                    Europe EN 300 330
Radio Approval                      USA FCC 47 CFR Part 15
                                    Canada IC RSS-Gen, RSS-210
EMC                                 EN 301 489

Safety and Health                   EN 60950
                                    EN 50364

Waste and Hazardous Substances      WEEE - 2002/96/EC
                                    RoHS - 2002/95/EC




FEIG ELECTRONIC GmbH             Page 17 of 17                   ID CPR44 User Manual-
                                                                                01.doc



Document Created: 2015-06-17 15:25:15
Document Modified: 2015-06-17 15:25:15

© 2024 FCC.report