UserManual.pdf

FCC ID: PJMCPR44

Users Manual

Download: PDF
FCCID_2653031

INSTALLATION


ID CPR44
ISO14443-A and -B RFID Reader




final - public (B)
ID CPR44 User Manual.doc


OBID® classic-pro                                   Installation                                     ID CPR44


                                                      Note

 Copyright 2010 - 2012 by
         FEIG ELECTRONIC GmbH
         Lange Strasse 4
         D-35781 Weilburg
         Tel.: +49 6471 3109-0
         http://www.feig.de

With the edition of this document, all previous editions become void. Indications made in this manual may be
changed without previous notice.

The reproduction, distribution and utilization of this document as well as the communication of its contents to
others without express authorization is prohibited. Offenders will be held liable for the payment of damages.
All rights reserved in the event of the grant of a patent, utility model or design.

Composition of the information in this document has been done to the best of our knowledge. FEIG
ELECTRONIC GmbH does not guarantee the correctness and completeness of the details given in this
manual and may not be held liable for damages ensuing from incorrect or incomplete information. Since,
despite all our efforts, errors may not be completely avoided, we are always grateful for your useful tips.

The instructions given in this manual are based on advantageous boundary conditions. FEIG ELECTRONIC
GmbH does not give any guarantee promise for perfect function in cross environments and does not give
any guaranty for the functionality of the complete system which incorporates the subject of this document.

FEIG ELECTRONIC call explicit attention that devices which are subject of this document are not designed
with components and testing methods for a level of reliability suitable for use in or in connection with surgical
implants or as critical components in any life support systems whose failure to perform can reasonably be
expected to cause significant injury to a human. To avoid damage, injury, or death, the user or application
designer must take reasonably prudent steps to protect against system failures.

FEIG ELECTRONIC GmbH assumes no responsibility for the use of any information contained in this
document and makes no representation that they free of patent infringement. FEIG ELECTRONIC GmbH
does not convey any license under its patent rights nor the rights of others.


     ®                   ®
OBID and OBID i-scan is a registered trademark of FEIG ELECTRONIC GmbH.
All brand names, trademarks or logos are property of their respective owners.




FEIG ELECTRONIC GmbH                             Page 2 of 16                   ID CPR44 User Manual.doc


OBID® classic-pro                                             Installation                                                    ID CPR44


                                                           Contents

1. Safety Instructions / Warning - Read before start-up !                                                                                 4

2. Characterization ID CPR44.0x-xx                                                                                                        5

3. Installation and wiring                                                                                                                6
  3.1. Dimensions ........................................................................................................................ 6
  3.2. Connection X1, X2 - Vcc and Interface ............................................................................. 7
  3.3. Digital Outputs ................................................................................................................... 8
  3.4. SAM Module ....................................................................................................................... 9
     3.4.1. Installation of a SAM Card.......................................................................................... 10
  3.5. Installation notes .............................................................................................................   11
     3.5.1. Metallic surroundings .................................................................................................       11
     3.5.2. EMC effects on cables ...............................................................................................         11
     3.5.3. EMC effects from magnetic fields ...............................................................................              12


4. Radio Approvals                                                                                                                        13
  4.1. Europe (CE) ...................................................................................................................... 13
  4.2. USA (FCC) and Canada (IC) ............................................................................................ 14


5. Technical Data                                                                                                                         15




FEIG ELECTRONIC GmbH                                         Page 3 of 16                          ID CPR44 User Manual.doc


OBID® classic-pro                          Installation                            ID CPR44



1. Safety Instructions / Warning - Read before start-up !

•   The device may only be used for the intended purpose designed by for the
    manufacturer.
•   The operation manual should be conveniently kept available at all times for each user.

•   Unauthorised changes and the use of spare parts and additional devices which have not
    been sold or recommended by the manufacturer may cause fire, electric shocks or
    injuries. Such unauthorised measures shall exclude any liability by the manufacturer.
•   The liability-prescriptions of the manufacturer in the issue valid at the time of purchase
    are valid for the device. The manufacturer shall not be held legally responsible for
    inaccuracies, errors, or omissions in the manual or automatically set parameters for a
    device or for an incorrect application of a device.

•   Repairs may only be executed by the manufacturer.
•   Installation, operation, and maintenance procedures should only be carried out by
    qualified personnel.
•   Use of the device and its installation must be in accordance with national legal
    requirements and local electrical codes .
•   When working on devices the valid safety regulations must be observed.

•   Special advice for carriers of cardiac pacemakers:
    Although this device doesn't exceed the valid limits for electromagnetic fields you
    should keep a minimum distance of 25 cm between the device and your cardiac pace-
    maker and not stay in an immediate proximity of the device respective the antenna for
    some time.




FEIG ELECTRONIC GmbH                    Page 4 of 16             ID CPR44 User Manual.doc


OBID® classic-pro                                      Installation                                    ID CPR44



2. Characterization ID CPR44

The reader modules ID CPR44 are designed for data exchange (read and write) with passive tran-
sponder according ISO14443 type A and type B and are capable for communication with NFC de-
vices (ISO18092) and supports the mifare classic security functions. The small dimensions and the
different available interfaces (RS232-TTL or USB) makes it suitable for an easy integration into
terminals, housings and other devices. If the device is connected to an USB host it works as a self-
powered device which requires a separate power supply.


The following different types are available:
                                        CPR44-4SCUSB




                                                                           CPR44-CUSB
Dimensions L x D x H (mm)          50 x 60 x 13,8                     50 x 60 x 7,3
Power supply                                              5 V / DC
SAM Socket                                4                                   -
Digital outputs                                              3
Interface
•   RS232-TTL
•   USB full-speed (12Mbit/s)



ID CPR44-4SCUSB
Reader module with internal antenna. The reader modules ID CPR44-4SCUSB are equipped with
4 sockets for Security Access Modules (SAM) in ID000 format.


ID CPR44-SCUSB
Reader module with internal antenna. The reader modules ID CPR44-SCUSB has no Security Ac-
cess Modules sockets.
Because of their high performance and a wide range of different configuration parameters the
reader modules ID CPR44 is suitable for a lot of applications like access control, ePayment,
eTicketing and public transport..
For further details about configuration parameters and commands please refer to the ID CPR44-
Family manual (H90700-xe-ID-B.pdf).




FEIG ELECTRONIC GmbH                                   Page 5 of 16                     ID CPR44 User Manual.doc


OBID® classic-pro                                      Installation                           ID CPR44



3. Installation and wiring


3.1. Dimensions
                7,5




                               7,2
                                                  ,5
                                               R1
                           1
         24,8

                  14




                       X2
                                                         J1
                           1
   50
   44




                                                          X6
                                                       ANT
                18




                       X1




                                                                  19,2
                       3                                              7,4                     *
                                     44
                                          60


                           Fig. 2 Top view                                     Fig. 1 Side view
                                                                               (* only types with SAM)




                                 Fig. 3 Button view. Types with SAM




FEIG ELECTRONIC GmbH                               Page 6 of 16             ID CPR44 User Manual.doc


OBID® classic-pro                             Installation                               ID CPR44



3.2. Connection X1, X2 - Vcc and Interface

The reader can be connected to a RS232-TTL interface and the power supply by using the multi-
pin connector X1. The multi-pin connector X2 provide the connection for the USB interface. The
device is a self-powered USB device which requires a separate power supply.
The following figure 5 and the table shows the assignment of the pins X1 (7pol.) and X2 (5pol.) Typ
“JST PH” RM 2 mm (horizontal).




   Fig. 4 Plug „JST PH“




                                                Fig. 5 Plug and connections



                        X1
                                   Symbol             ID CPR44
                      Pin-No.
                          1         OUT1            Digital Output 1
                          2         OUT2            Digital Output 2
                          3         OUT3            Digital Output 3
                          4         GND*
                          5         RxD               RS232-TTL
                          6         TxD               RS232-TTL
                          7        VCC**            + 5 V DC ± 5 %
                        X2
                      Pin-No.
                          1       Shielding       USB-Cable Shielding
                          2         GND*
                          3      USB-D PLUS
                          4     USB-D MINUS
                          5        VCC**            + 5 V DC ± 5 %

* GND are connected internal directly
** VCC are connected internal directly. Feed-In VCC only at one pin!



FEIG ELECTRONIC GmbH                          Page 7 of 16              ID CPR44 User Manual.doc


OBID® classic-pro                            Installation                               ID CPR44


NOTICE:
• The reader has to supplied by a limited power supply (e.g. NEC Class 2/LPS power sup-
  ply) according IEC EN 60950, only
• Use only regulated power supply’s.

• The connection cable (RS232TTL, USB, VCC) should be as short as possible and must be
  shorter than 3 m.
• Reversing the polarity of the supply voltage may destroy the device.
• Supply voltages outside the specifications may destroy the device.

• If switching power supplies are used with the module, be sure that there is adequate fil-
  tering.

• Noise from the power supply can result in a reduction of the read/write range of the
  module.



3.3. Digital Outputs

The Fig. 6 shows the circuit diagram of the digital outputs OUT1 – OUT3. The digital outputs are
intended for the connection of external LED’s.




                       Fig. 6 Wiring of digital outputs OUT1...3




FEIG ELECTRONIC GmbH                      Page 8 of 16              ID CPR44 User Manual.doc


OBID® classic-pro                           Installation                                ID CPR44



3.4. SAM Module

Fig. 8 shows the position of the 2 SAM connector (double stacked) X4 and X5. Each SAM con-
nector is designed for two ID000 formatted (SIM Karte) SAM modules.


NOTICE
•     The SAM connectors are designed only for occasional opening and closing cycles.
•     Wrong inserted SAM modules and forcefully opening or closing will damage the SAM
      connectors.




    Socket    Position   SAM Number
                top           3
     X4
              button          1
                top           4
     X5
              button          2




                                                           Fig. 7 Position der 4 SAM Module


                         Slot for SAM Card 3 and 4




                Slot for SAM Card 1 and 2




                                  Fig. 8 SAM Modul




FEIG ELECTRONIC GmbH                        Page 9 of 16              ID CPR44 User Manual.doc


OBID® classic-pro                             Installation                              ID CPR44



3.4.1. Installation of a SAM Card

The following step by step instruction shows the installation of the SAM Card 1 and 3 into the SAM
connector X4. The installation of the SAM Cards 2 and 4 in the socket X5 must be done in the
same way.




1. Unlatch the top cover at the front edge.        2. Push the cover of lower slot backwards and
                                                   open it




3. Put the SAM module 1 into the cover of the      4. Turn down the cover of the lower slot and
lower slot. The contact plate face down            push it forward till the cover is locked.




5. Place the SAM Cart 3 with the contact face at 6. Close the top cover with carefully pressure to
the top on the cover of the lower slot.          snap into place.



FEIG ELECTRONIC GmbH                      Page 10 of 16              ID CPR44 User Manual.doc


OBID® classic-pro                              Installation                                  ID CPR44



3.5. Installation notes

Be aware of the following possible environmental factors when installing an ID CPR44into another
device :
•   Effects from nearby metal objects
    ⇒ Detuning of the integrated antenna
    ⇒ Impaired communication of the antenna’s magnetic field
•   EMC effects on cables
    ⇒ Impaired communication between reader and transponder

•   EMC effects from magnetic fields
    ⇒ Impaired communication between reader and transponder



3.5.1. Metallic surroundings

When installing an ID CPR44into another device, be sure that there are no metal surfaces or ob-
jects in the direct vicinity of the reader if possible. These can detune the antenna and thus reduce
the magnetic field of the integrated antenna. This will in turn result in reduced read distances for
the reader.
The distance between the reader and a metal surface should be at least 3 cm. Note that
even other circuit boards may act like metal objects depending on how much copper they
contain.
If a metallic surrounding cannot be avoided, stable function should at least be ensured by keeping
the distance as great as possible.
The area between the antenna and transponder as well as the area on the other side of the tran-
sponder should also be kept clear of metal parts.
Since any change in the metallic environment will result in detuning of the integrated antenna and
therefore to impaired function, no moving metal parts, such as metallic fans, should be allowed in
the vicinity of the reader.



3.5.2. EMC effects on cables

In spite of the internal EMC filters inside the reader, high levels of noise on the supply voltage can
result in impairment of the communication between the reader and transponder.
When installing an ID CPR44 into another device, be sure therefore that a clean, noise-free power
supply is used.




FEIG ELECTRONIC GmbH                         Page 11 of 16                ID CPR44 User Manual.doc


OBID® classic-pro                            Installation                                ID CPR44



3.5.3. EMC effects from magnetic fields

The communication principle of RFID- Technology is based on the modulation of electromagnetic
fields. Alternating magnetic fields in the vicinity of the antenna can have a negative influence on
the reader function.
Sources of such magnetic interference fields include coils within a primary or secondary switching
power supply.
When determining the position of the reader and antenna within a device, check the device for any
possible sources of interference as described above. If necessary, use shielding to suppress such
interference.




FEIG ELECTRONIC GmbH                      Page 12 of 16               ID CPR44 User Manual.doc


OBID® classic-pro                          Installation                                ID CPR44



4. Radio Approvals


4.1. Europe (CE)



When used according to regulation, this radio equipment conforms with the basic requirements of
Article 3 and the other relevant provisions of the R&TTE Guideline 1999/EC dated March 99.




                 Equipment Classification according ETSI EN 300 330: Class 2




FEIG ELECTRONIC GmbH                      Page 13 of 16              ID CPR44 User Manual.doc


OBID® classic-pro                                Installation                                    ID CPR44




4.2. USA (FCC) and Canada (IC)

       Product name:                                          ID CPR44

                FCC ID:                                      PJMCPR44
                      IC:                                  6633A-CPR44

 Notice for USA and            This device complies with Part 15 of the FCC Rules and with
      Canada                   RSS-210 of Industry Canada.
                               Operation is subject to the following two conditions.
                               (1) this device may not cause harmful interference, and
                               (2) this device must accept any interference received,
                               including interference that may cause undesired operation.
                               Unauthorized modifications may void the authority granted under
                               Federal communications Commission Rules permitting the operation
                               of this device.
                               This equipment has been tested and found to comply with the limits for
                               a Class A digital device, pursuant to Part 15 of the FCC Rules. These
                               limits are designed to provide reasonable protection against harmful
                               interference when the equipment is operated in a commercial
                               environment. This equipment generates, uses, and can radiate radio
                               frequency energy and, if not installed and used in accordance with the
                               instruction manual, may cause harmful interference to radio
                               communications. Operation of this equipment in a residential area is
                               likely to cause harmful interference in which case the user will be
                               required to correct the interference at his own expense.
                               Le présent appareil est conforme aux CNR d'Industrie Canada appli-
                               cables aux appareils radio exempts de licence. L'exploitation est auto-
                               risée aux deux conditions suivantes :
                               (1) l'appareil ne doit pas produire de brouillage, et
                               (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique
                               subi, même si le brouillage est susceptible d'en compromettre le fonc-
                               tionnement.


Warning: Changes or modification made to this equipment not expressly approved by
FEIG ELECTRONIC GmbH may void the FCC authorization to operate this equipment.
Installation with FCC / IC Approval:
FCC-/IC-NOTICE: To comply with FCC Part 15 Rules in the United States / with IC Radio Stand-
ards in Canada, the system must be professionally installed to ensure compliance with the Part 15
certification / IC certification. It is the responsibility of the operator and professional installer to en-
sure that only certified systems are deployed in the United States / Canada.




FEIG ELECTRONIC GmbH                         Page 14 of 16                 ID CPR44 User Manual.doc


OBID® classic-pro                               Installation                                                ID CPR44



5. Technical Data



    Weight                                         approx 20 g

    Antenna                                        •   Internal (48 mm x 58 mm)

    Temperature Range                   Operating -25°C to +70°C
                                         Storage -40°C to +85°C

    Humidity                                       0 to 95 % not condensing

    Power Supply                                   •   5 V DC ± 5 %         Ripple:
                                                                   0...250 kHz < 10 mVpp
                                                                   up from 250 kHz < 0,1 mVpp
                                                                      1
    Current consumption                            typ. 300 mA

    RF Interface                                   ISO14443-A & ISO14443-B (Part 4 fully supported)
                                                   106, 212, 424, 847 kbit/s

    Supported Transponder                          mifare classic, mifare Ultralight, mifare Ultralight C,
    (reading and writing)                          mifare DESfire, mifare PLUS, Smart MX, my-d proxim-
                                                   ity, SLE44R35S, SLE55R, Jewel, SLE66CL,
                                                   ST19XR34, SRI4K, SRIX4K, SRI512, SR176, RF360,
                                                   etc.
                                                   NFC Type 1, 2 and Type 4 in card emulation mode

    Operating Frequency                            13.56 MHz

    RF Transmitting Power                          400 mW ± 2 dB

    Host-Interface                                 •   USB Full-Speed (12 Mbit/s)
                                                       Self-Powered Device
                                                   •   RS232-TTL (4.800 to 230.400 Baud)

    Digital Output                                 3 (Iout   high   max.: 5 mA / Iout   low   max.: 8 mA)

    Connector

                   VCC, RS232TTL, Digital Outputs: •   JST PH 7pin. (X1)
                                            USB: •     JST PH 5pin. (X2)

    Contact Interface (ISO7816)                    4 * SAM Socked for ID000 Format (SIM-Card)
    (only types with SAM)                          9600 to 375.000 bit/s
                                                   T=0 and T=1 Protocol
                                                   for 1,8 V; 3 V; 5 V Smartcards

    MTBF                                           500.000 h




1
    Current consumption of SAMs excluded
FEIG ELECTRONIC GmbH                           Page 15 of 16                        ID CPR44 User Manual.doc


OBID® classic-pro                   Installation                                  ID CPR44


USB Driver                            •   PC/SC Driver for Windows
                                      •
                                                       ®
                                          Native OBID USB Driver for Windows
                                      •
                                                   ®
                                          Windows CE for different platforms on request

Operating Modes                       Polling-Mode
                                            6
EEPROM (for Parameter)                1 * 10 write cycles

FLASH (for Firmware)                  (Firmware update in Application possible)


                                      Europe EN 300 330
Radio Approval                        USA FCC 47 CFR Part 15
                                      Canada IC RSS-Gen, RSS-210
EMC                                   EN 301 489

Safety and Health                     EN 60950

                                      EN 50364

Waste and Hazardous Substances        WEEE - 2002/96/EC

                                      RoHS - 2002/95/EC




FEIG ELECTRONIC GmbH             Page 16 of 16              ID CPR44 User Manual.doc



Document Created: 2015-04-08 12:22:43
Document Modified: 2015-04-08 12:22:43