TestReport.pdf

FCC ID: PJMCPR44

Test Report

Download: PDF
FCCID_2653029

                                                          TEST REPORT
                                                Test report no.: 1-9651/15-01-02

                  Testing laboratory                                                               Applicant
 CETECOM ICT Services GmbH                                                      FEIG ELECTRONIC GmbH
 Untertuerkheimer Strasse 6 – 10                                                Lange Str. 4
 66117 Saarbruecken / Germany                                                   35781 Weilburg-Waldhausen / GERMANY
 Phone:    + 49 681 5 98 - 0                                                    Phone:    +49 6471 31 09-0
 Fax:      + 49 681 5 98 - 9075                                                 Fax:      +49 6471 310-999
 Internet: http://www.cetecom.com                                               Contact: Bernhard Schüßler
 e-mail:   ict@cetecom.com                                                      e-mail:   bernhard.schuessler@feig.de
                                                                                Phone:    +49 6471 310-9435
 Accredited Testing Laboratory:
 The testing laboratory (area of testing) is accredited
 according to DIN EN ISO/IEC 17025 (2005) by the
 Deutsche Akkreditierungsstelle GmbH (DAkkS)                                                     Manufacturer
 The accreditation is valid for the scope of testing                            FEIG ELECTRONIC GmbH
 procedures as stated in the accreditation certificate with                     Lange Str. 4
 the registration number: D-PL-12076-01-00                                      35781 Weilburg-Waldhausen / GERMANY


                                                                Test standard/s
 47 CFR Part 15                Title 47 of the Code of Federal Regulations; Chapter I; Part 15 - Radio frequency
                               devices
 RSS - 210 Issue 8             Spectrum Management and Telecommunications Radio Standards Specification -
                               Licence-exempt Radio Apparatus (All Frequency Bands): Category I Equipment
 For further applied test standards please refer to section 3 of this test report.


                                                                         Test Item
 Kind of test item:           RF Reader Module
 Model name:                  ID CPR44
 FCC ID:                      PJMCPR44
 IC:                          6633A-CPR44
 Frequency:                   13.56 MHz
 Technology tested:           RFID
 Antenna:                     Integrated antenna
 Power supply:                5 V DC by power supply
 Temperature range:           -25°C to +70°C

This test report is electronically signed and valid without handwriting signature. For verification of the electronic signatures,
the public keys can be requested at the testing laboratory.


 Test report authorised:                                                      Test performed:
                                                                                                        cn=Christoph Schneider, o=CETECOM ICT
                               cn=Marco Bertolino, o=CETECOM ICT
                                                                                                        Services GmbH, ou=SND-120402,
                               Services GmbH, ou=BTL-100826,
                               email=marco.bertolino@cetecom.com, c=DE
                                                                                                        email=christoph.schneider@cetecom.com,
                               2015.06.17 15:51:11 +02'00'                                              c=DE
                                                                                                        2015.06.17 15:49:54 +02'00'

 Marco Bertolino                                                              Christoph Schneider
 Lab Manager                                                                  Testing Manager
 Radio Communications & EMC                                                   Radio Communications & EMC


                                                       Test report no.: 1-9651/15-01-02



1      Table of contents

1    Table of contents ............................................................................................................................................2
2    General information .......................................................................................................................................3
     2.1       Notes and disclaimer ..........................................................................................................................3
     2.2       Application details ...............................................................................................................................3
3    Test standard/s ...............................................................................................................................................3
4    Test environment ............................................................................................................................................4
5    Test item ..........................................................................................................................................................4
     5.1       Additional information ........................................................................................................................4
6    Test laboratories sub-contracted .................................................................................................................4
7    Description of the test setup .........................................................................................................................5
     7.1       Shielded semi anechoic chamber ......................................................................................................6
     7.2       Shielded full anechoic chamber.........................................................................................................7
     7.3       Conducted measurements normal and extreme conditions ...........................................................8
8    Summary of measurement results ...............................................................................................................9
9    Additional comments .....................................................................................................................................9
10      Measurement results ................................................................................................................................10
     10.1         Occupied bandwidth ......................................................................................................................10
     10.2         Field strength of the fundamental ................................................................................................12
     10.3         Field strength of the harmonics and spurious ...........................................................................13
     10.4         Frequency error .............................................................................................................................16
     10.5         Conducted limits ............................................................................................................................17
11      Observations .............................................................................................................................................19
Annex A           Document history ..........................................................................................................................20
Annex B           Further information ........................................................................................................................20
Annex C           Accreditation Certificate ...............................................................................................................21




                                                                          Page 2 of 21


                                       Test report no.: 1-9651/15-01-02



2     General information

2.1   Notes and disclaimer
The test results of this test report relate exclusively to the test item specified in this test report. CETECOM ICT
Services GmbH does not assume responsibility for any conclusions and generalizations drawn from the test
results with regard to other specimens or samples of the type of the equipment represented by the test item.
The test report may only be reproduced or published in full. Reproduction or publication of extracts from the report
requires the prior written approval of CETECOM ICT Services GmbH.
The testing service provided by CETECOM ICT Services GmbH has been rendered under the current "General
Terms and Conditions for CETECOM ICT Services GmbH".
CETECOM ICT Services GmbH will not be liable for any loss or damage resulting from false, inaccurate,
inappropriate or incomplete product information provided by the customer.
Under no circumstances does the CETECOM ICT Services GmbH test report include any endorsement or
warranty regarding the functionality, quality or performance of any other product or service provided.
Under no circumstances does the CETECOM ICT Services GmbH test report include or imply any product or
service warranties from CETECOM ICT Services GmbH, including, without limitation, any implied warranties of
merchantability, fitness for purpose, or non-infringement, all of which are expressly disclaimed by CETECOM ICT
Services GmbH.
All rights and remedies regarding vendor’s products and services for which CETECOM ICT Services GmbH has
prepared this test report shall be provided by the party offering such products or services and not by CETECOM
ICT Services GmbH.
In no case this test report can be considered as a Letter of Approval.

This test report is electronically signed and valid without handwritten signature. For verification of the electronic
signatures, the public keys can be requested at the testing laboratory.


2.2   Application details
Date of receipt of order:                2015-03-31
Date of receipt of test item:            2015-04-01
Start of test:                           2015-05-11
End of test:                             2015-05-13
Person(s) present during the test:       -/-


3     Test standard/s
 Test standard            Date                 Test standard description

 47 CFR Part 15           -/-                  Title 47 of the Code of Federal Regulations; Chapter I; Part 15 -
                                               Radio frequency devices
 RSS - 210 Issue 8        01.12.2010           Spectrum Management and Telecommunications Radio
                                               Standards Specification - Licence-exempt Radio Apparatus (All
                                               Frequency Bands): Category I Equipment
 RSS - Gen Issue 4        01.11.2014           Spectrum Management and Telecommunications Radio
                                               Standards Specifications - General Requirements and
                                               Information for the Certification of Radio Apparatus




                                                   Page 3 of 21


                                          Test report no.: 1-9651/15-01-02



4      Test environment
                                    Tnom       +22 °C during room temperature tests
          Temperature:              Tmax       +70 °C during high temperature tests
                                    Tmin       -25 °C during low temperature tests

    Relative humidity content:                 43 %

       Barometric pressure:                    not relevant for this kind of testing

                                    Vnom       5    V    DC by power supply
          Power supply:             Vmax       5.25 V
                                    Vmin       4.75 V


5      Test item

Kind of test item             :     RF Reader Module
PMN                           :     ID CPR44
HVIN                          :     ID CPR44
FVIN                          :     -/-
HMN                           :     -/-


S/N serial number             :     5299382
Hardware version              :     FE 670
Software version              :     03.95.00
Frequency band                :     13.56 MHz
Type of radio transmission :
                                    modulated carrier
Use of frequency spectrum :
Type of modulation            :     A1D
Number of channels            :     1
Antenna                       :     Integrated antenna
Power supply                  :     5 V DC by power supply
Temperature range             :     -25°C to +70°C



5.1    Additional information
The content of the following annexes is defined in the QA. It may be that not all of the listed annexes are
necessary for this report, thus some values in between may be missing.

Test setup- and EUT-photos are included in test report:            1-9651/15-01-01_AnnexB
                                                                   1-9651/15-01-01_AnnexD


6      Test laboratories sub-contracted
None




                                                      Page 4 of 21


                                              Test report no.: 1-9651/15-01-02



7           Description of the test setup
Typically, the calibrations of the test apparatus are commissioned to and performed by an accredited calibration
laboratory. The calibration intervals are determined in accordance with the DIN EN ISO/IEC 17025. In addition to
the external calibrations, the laboratory executes comparison measurements with other calibrated test systems
or effective verifications. Weekly chamber inspections and range calibrations are performed. Where possible, RF
generating and signalling equipment as well as measuring receivers and analysers are connected to an external
high-precision 10 MHz reference (GPS-based or rubidium frequency standard).

In order to simplify the identification of the equipment used at some special tests, some items of test equipment
and ancillaries can be provided with an identifier or number in the equipment list below (Lab/Item).



Agenda: Kind of Calibration

    k        calibration / calibrated                            EK      limited calibration
    ne       not required (k, ev, izw, zw not required)          zw      cyclical maintenance (external cyclical
                                                                         maintenance)
    ev       periodic self verification                          izw     internal cyclical maintenance
    Ve       long-term stability recognized                      g       blocked for accredited testing
    vlkI!    Attention: extended calibration interval
    NK!      Attention: not calibrated                           *)      next calibration ordered / currently in progress




                                                          Page 5 of 21


                                                Test report no.: 1-9651/15-01-02



7.1   Shielded semi anechoic chamber
The radiated measurements are performed in vertical and horizontal plane in the frequency range from 9 kHz to
1 GHz in semi-anechoic chambers. The EUT is positioned on a non-conductive support with a height of 0.80 m
above a conductive ground plane that covers the whole chamber. The receiving antennas are confirmed with
specifications ANSI C63. These antennas can be moved over the height range between 1.0 m and 4.0 m in order
to search for maximum field strength emitted from EUT. The measurement distances between EUT and receiving
antennas are indicated in the test setups for the various frequency ranges. For each measurement, the EUT is
rotated in all three axes until the maximum field strength is received. The wanted and unwanted emissions are
received by spectrum analysers where the detector modes and resolution bandwidths over various frequency
ranges are set according to requirement ANSI C63.




Equipment table:

      Lab /                                                                          INV. No     Kind of     Last        Next
No.           Equipment              Type              Manufact.        Serial No.
      Item                                                                           Cetecom     Calibration Calibration Calibration
1     n. a.   Anechoic chamber       FAC 3/5m          MWB / TDK        87400/02     300000996   ev
2     45      Switch-Unit            3488A             HP               2719A14505   300000368   g
              DC power supply,
3     50                             6032A             HP               2920A04466   300000580   ne
              60Vdc, 50A, 1200 W
4     50      EMI Test Receiver      ESCI 3            R&S              100083       300003312   k           26.01.2015   26.01.2016
              Analyzer-Reference-
                                                                        A3509 07/0
5     50      System (Harmonics      ARS 16/1          SPS                           300003314   Ve          11.02.2014   11.02.2016
                                                                        0205
              and Flicker)
6     50      Antenna Tower          Model 2175        ETS-Lindgren     64762        300003745   izw
              Positioning
7     50                             Model 2090        ETS-Lindgren     64672        300003746   izw
              Controller
              Turntable Interface-
8     50                             Model 105637      ETS-Lindgren     44583        300003747   izw
              Box
              TRILOG Broadband
9     50      Test-Antenna 30        VULB9163          Schwarzbeck      295          300003787   k           22.04.2014   22.04.2016
              MHz - 3 GHz
10    50      Spectrum-Analyzer      FSU26             R&S              200809       300003874   k           26.01.2015   26.01.2016
              Breitband
11    50      Doppelsteg-            BBHA9120 B        Schwarzbeck      188          300003896   k           10.06.2013   10.06.2015
              Hornantenne




                                                             Page 6 of 21


                                               Test report no.: 1-9651/15-01-02



7.2   Shielded full anechoic chamber




Equipment table:

      Lab /                                                                             INV. No     Kind of     Last        Next
No.           Equipment             Type              Manufact.            Serial No.
      Item                                                                              Cetecom     Calibration Calibration Calibration
1     n. a.   Anechoic chamber      FAC 3/5m          MWB / TDK            87400/02     300000996   ev
              DC power supply,
2     n. a.                         6032A             HP                   2818A03450   300001040   Ve          20.01.2015   20.01.2018
              60Vdc, 50A, 1200 W
              Active Loop Antenna
3     90                            6502              Kontron Psychotech   8905-2342    300000256   k           13.06.2013   13.06.2015
              10 kHz to 30 MHz
              MXE EMI Receiver
4     90                            N9038A            Agilent Technologies MY51210197   300004405   k           06.03.2015   06.03.2016
              20 Hz to 26,5 GHz
              4U RF Switch
5     90                            L4491A            Agilent Technologies MY50000037   300004509   ne
              Platform




                                                           Page 7 of 21


                                              Test report no.: 1-9651/15-01-02



7.3   Conducted measurements normal and extreme conditions




Equipment table:

      Lab /                                                                           INV. No     Kind of     Last        Next
No.           Equipment             Type             Manufact.           Serial No.
      Item                                                                            Cetecom     Calibration Calibration Calibration
              EMI Test Receiver 9
1     n. a.   kHz - 3 GHz incl.     ESPI3            R&S                 101713       300004059   k           23.01.2015   23.01.2016
              Preselector
              DC Power Supply 0
2     n. a.                         1108-32          Heiden Elektronik   001802       300001383   Ve          29.01.2014   29.01.2017
              – 32V
              Temperature Test
3     n. a.                         T-40/50          CTS GmbH            064023       300003540   Ve          26.09.2013   26.09.2015
              Chamber




                                                           Page 8 of 21


                                           Test report no.: 1-9651/15-01-02




8       Summary of measurement results

         ☒           No deviations from the technical specifications were ascertained
         ☐           There were deviations from the technical specifications ascertained
                     This test report is only a partial test report. The content and verdict of the performed test cases
         ☐           are listed below.

    TC Identifier                    Description                       Verdict           Date               Remark
                                     CFR Part 15
     RF-Testing                    RSS 210 Issue 8                    See table!     2015-06-17               -/-
                                   RSS Gen Issue 4

         Test
                                                Temperature      Power source
    specification           Test case                                         Pass Fail          NA    NP     Remark
                                                 conditions       conditions
       clause
      RSS Gen                                                                                                No pass /
       Issue 4
                       Occupied bandwidth         Nominal           Nominal         ☐      ☐     ☐     ☐ fail criteria

                       Field strength of the
    § 15.225 (a)
                           fundamental
                                                  Nominal           Nominal         ☒      ☐     ☐     ☐      complies

       § 15.209        Field strength of the
          &               harmonics and           Nominal           Nominal         ☒      ☐     ☐     ☐      complies
    § 15.225 (b-d)           spurious

                       Receiver spurious
      § 15.109        emissions and cabinet       Nominal           Nominal         ☐      ☐     ☒     ☐      complies
                            radiations

      §15.107
      §15.207
                         Conducted limits         Nominal           Nominal         ☒      ☐     ☐     ☐      complies

                                                  Normal &         Normal &
    § 15.225 (a)       Frequency tolerance         extreme          extreme         ☒      ☐     ☐     ☐      complies
                                                  conditions       conditions


Note: NA = Not Applicable; NP = Not Performed



9       Additional comments
Reference documents:                None

Special test descriptions:          None

Configuration descriptions:         None




                                                      Page 9 of 21


                                    Test report no.: 1-9651/15-01-02



10       Measurement results

10.1 Occupied bandwidth
Measurement:

The emission bandwidth (x dB) is defined as the frequency range between two points, one above and one
below the carrier frequency, at which the spectral density of the emission is attenuated x dB below the
maximum in-band spectral density of the modulated signal.

                                         Measurement parameters
 Detector:                                                Peak
 Resolution bandwidth:                                    1 % – 5 % of the occupied bandwidth
 Video bandwidth:                                         ≥ 3x RBW
 Trace mode:                                              Max hold
 Analyser function:                                       99 % power function



Limit:

                                                     IC
                                   for RSP-100 test report coversheet only



Result:

                                         99% emission bandwidth
                                                  910 kHz
               Measurement uncertainty                                        ± RBW




                                               Page 10 of 21


                                                 Test report no.: 1-9651/15-01-02



Plot:

Plot 1: 99 % emission bandwidth
                                                                            * RBW   10   kHz   Marker      1   [T1   ]
                                                                             VBW    30   kHz                      -2.19      dBm
                       Ref   10   dBm                Att   30    dB          SWT    50   ms           13.560000000           MHz

                       10                                                                      OBW910.000000000              kHz
                                                                                               Temp    1   [T1    OBW]
                       0                                                1                                        -32.65      dBm   A

                                                                                                      13.070000000           MHz
                1 PK
                                                                                               Temp    2   [T1    OBW]
                MAXH
                       -10                                                                                       -29.50      dBm
                                                                                                      13.980000000           MHz

                       -20


                                                                                    T2
                       -30                                  T1




                       -40


                                                                                                                                   3DB
                       -50



                       -60



                       -70



                       -80


                       -90

                       Center     13.56   MHz                     500   kHz/                                     Span    5   MHz




                Date: 11.MAY.2015               08:29:11




                                                                  Page 11 of 21


                                     Test report no.: 1-9651/15-01-02



10.2 Field strength of the fundamental
Measurement:

The maximum detected field strength for the carrier signal.

                                          Measurement parameters
 Detector:                                                       Quasi peak / peak (worst case)
 Resolution bandwidth:                                           120 kHz
 Video bandwidth:                                                ≥ 3x RBW
 Trace mode:                                                     Max hold



Limit:

                                                   FCC & IC
             Frequency                           Field strength                                           Measurement distance
               (MHz)                                 (µV/m)                                                       (m)
          13.553 to 13.567                    15,848 (84 dBµV/m)                                                   30



Recalculation:

                                          According to ANSI C63.10
          Frequency                                 Formula                                                    Correction value
                                                              𝑑nearfield                  𝑑𝑙𝑖𝑚𝑖𝑡
          13.56 MHz               FSlimit = FSmax −40 log (                ) − 20log⁡(                )            -21.76
                                                              𝑑𝑚𝑒𝑎𝑠𝑢𝑟𝑒                   𝑑𝑛𝑒𝑎𝑟𝑓𝑖𝑒𝑙𝑑




                                          According to ANSI C63.10

Result:

                                      Field strength of the fundamental
 Frequency                                                                         13.56 MHz
 Distance                                            @3m                                                        @ 30 m
 Measured / calculated value                  66.94 dBµV/m (peak)                                         45.18 dBµV/m (peak)
 Measurement uncertainty                                                                 ±3 dB




                                                 Page 12 of 21


                                     Test report no.: 1-9651/15-01-02



10.3 Field strength of the harmonics and spurious
Measurement:

The maximum detected field strength for the harmonics and spurious.

                                          Measurement parameters
                                                       Quasi peak / average or
 Detector:
                                                       peak (worst case – pre-scan)
                                                       F < 150 kHz: 200 Hz
 Resolution bandwidth:                                 150 kHz < F < 30 MHz: 9 kHz
                                                       30 MHz < F < 1 GHz: 120 kHz
                                                       F < 150 kHz: 1 kHz
 Video bandwidth:                                      150 kHz < F < 30 MHz: 100 kHz
                                                       30 MHz < F < 1 GHz: 300 kHz
 Trace mode:                                           Max hold



Limit:

                                                  FCC & IC
               Frequency                        Field strength                   Measurement distance
                  (MHz)                           (dBµV/m)                              (m)
             0.009 – 0.490                       2400/F(kHz)                            300
             0.490 – 1.705                      24000/F(kHz)                             30
               1.705 – 30                     30 (29.5 dBµV/m)                           30
                 30 – 88                       100 (40 dBµV/m)                            3
                88 – 216                      150 (43.5 dBµV/m)                           3
               216 – 960                       200 (46 dBµV/m)                            3

Note:      For a reduced measurement distance, please take a look at the limit line and the ANSI C63.10-2013
           sub clause 6.4 radiated emissions from unlicensed wireless devices below 30 MHz.



Result:

                                             Detected emissions
          Frequency                                      Resolution bandwidth
                                     Detector                                            Detected value
            (MHz)                                                (kHz)
                                                  See plot 3


                Measurement uncertainty                                         ±3 dB




                                                 Page 13 of 21


                                                            Test report no.: 1-9651/15-01-02



Plots:

Plot 1: 9 kHz – 30 MHz, magnetic emissions
         130
dBµV/m



         120




         110




         100




         90




         80




         70




         60




         50



                                                                                                                                                            - Class - QPeak
         40




         30




         20




         10




          0
               9kHz                                  100k                                                       1M                                    10M           30MHz
                                                                                       Frequency (MHz)




Plot 2: Spectrum mask (the limits are recalculated according to the ANSI C63.10-2013 sub clause 6.4)
                                                                                     RBW    9     kHz          Marker   1   [T1   ]
                                                                                     VBW    100          kHz                 66.42    dBµV
                               Ref    90   dBµV               Att   50   dB         * SWT   60       s               13.568000000         MHz

                               90    Offset   -35.3      dB


                                                                                                                                                A
                               80

                      1 QP *
                      CLRWR
                               70                                               1
                                                                                                                                                LVL



                               60


                               FCC15225
                               50



                               40


                                                                                                                                                6DB
                               30



                               20



                               10



                               0


                               -10

                               Center      13.56   MHz                    200   kHz/                                         Span     2   MHz




                      Date: 18.MAY.2015                  09:42:21




                                                                          Page 14 of 21


                                                  Test report no.: 1-9651/15-01-02




Plot 3: 30 MHz – 1 GHz, vertical and horizontal polarisation



                          60

                          55

                          50

                          45                                                                          F CC _ 1 0 m_ B

                          40
        Level in dBµV/m




                          35

                          30

                          25

                          20

                          15

                          10

                          5

                          0
                          30M        50 60     80 100M               200         300      400 500           8 0 0 1 ,0 5 G
                                                           F re q u e n c y in H z




Final_Result
   Frequency                    QuasiPeak      Limit     Margin      Meas.           Bandwidth    Height      Pol      Azimuth     Corr.
     (MHz)                      (dBµV/m)     (dBµV/m)     (dB)       Time              (kHz)       (cm)                 (deg)      (dB)
                                                                     (ms)
     40.689150                       27.46       30.00      2.54     1000.0             120.000     100.0     V              232    14.0
     81.362250                       22.19       30.00      7.81     1000.0             120.000     273.0     V              282     8.4
    352.564350                       31.91       36.00      4.09     1000.0             120.000     349.0     V              117    16.1
    406.796700                       28.97       36.00      7.03     1000.0             120.000     100.0     V                3    17.0
    420.347850                       27.65       36.00      8.35     1000.0             120.000     100.0     V                5    17.2
    474.600000                       32.95       36.00      3.05     1000.0             120.000     274.0     V               53    18.2




                                                             Page 15 of 21


                                    Test report no.: 1-9651/15-01-02



10.4 Frequency error
Measurement:

The maximum detected field strength for the spurious.

                                         Measurement parameters
 Detector:                                            Peak detector
 Resolution bandwidth:                                10 Hz / 100 Hz
 Video bandwidth:                                     > RBW
 Trace mode:                                          Max hold



Limit:

                                                    FCC
  The frequency tolerance of the carrier signal shall be maintained within +/- 0.01% of the operating
  frequency over a temperature variation of -20 degrees to +50 degrees C at normal supply voltage,
  and for a variation in the primary supply voltage from 85% to 115% of the rated supply voltage at a
                                temperature of 20 degrees C. (±1.356 kHz)



Result: Temperature variation

                                        Frequency tolerance
         Measured frequency
                                                Conditions                         Result
               (MHz)
            13.559812                    -20 °C & 100% voltage                    complies
            13.559846                    -10 °C & 100% voltage                    complies
            13.559857                     0 °C & 100% voltage                     complies
            13.559846                   +10 °C & 100% voltage                     complies
            13.559803                   +20 °C & 100% voltage                     complies
            13.559792                   +30 °C & 100% voltage                     complies
            13.559770                   +40 °C & 100% voltage                     complies
            13.559759                   +50 °C & 100% voltage                     complies
                        Measurement uncertainty                                    ± RBW



Result: Voltage variation

                                        Frequency tolerance
         Measured frequency
                                              Temperature                          Result
               (MHz)
            13.559802                    +20 °C & 85% voltage                     complies
            13.559803                   +20 °C & 100% voltage                     complies
            13.559803                   +20 °C & 115% voltage                     complies
                        Measurement uncertainty                                    ± RBW




                                               Page 16 of 21


                                     Test report no.: 1-9651/15-01-02



10.5 Conducted limits
Measurement:

Measurement of the conducted spurious emissions for an intentional radiator that is designed to be connected
to the public utility (AC) power line.

                                          Measurement parameters
                                                       Quasi peak / average or
 Detector:
                                                       peak (worst case – pre-scan)
                                                       F < 150 kHz:        200 Hz
 Resolution bandwidth:
                                                       F > 150 kHz:        9 kHz
                                                       F < 150 kHz:        1 kHz
 Video bandwidth:
                                                       F > 150 kHz:        100 kHz
 Trace mode:                                           Max hold



Limit:

                                                   FCC & IC
              Frequency                           Quasi-peak                            Average
                (MHz)                              (dBµV/m)                            (dBµV/m)
               0.15 – 0.5                          66 to 56*                           56 to 46*
                 0.5 – 5                              56                                  46
                5 – 30.0                              60                                  50




Result:

                                              Detected emissions
          Frequency                                       Resolution bandwidth
                                      Detector                                          Detected value
            (MHz)                                                 (kHz)
                            All detected peak emissions are below the average limit.




                                                Page 17 of 21


                                          Test report no.: 1-9651/15-01-02



Plots:

Plot 1: 150 kHz to 30 MHz, phase line


                                                            FCC                                                Premeasurement
                                                                                                               Average limit class B
                                                        Measurement                                            Quasi peak limit class B
                                                                                                               L_Peaks_fin
                                                         Phase line                                            Average level
                                                                                                               Quasi peak level




                               80.0




                               70.0




                               60.0




                               50.0
           Amplitude in dBµV




                               40.0




                               30.0




                               20.0




                               10.0




                                  0
                                 100.0K      1.0M                        10.0M                                               100.0M
                                                       Frequency in Hz
                                                                                 Project ID: 1-9651/15-01-02




Plot 2: 150 kHz to 30 MHz, neutral line


                                                            FCC                                                Premeasurement
                                                                                                               Average limit class B
                                                        Measurement                                            Quasi peak limit class B
                                                                                                               N_Peaks_fin
                                                         Neutral line                                          Average level
                                                                                                               Quasi peak level




                               80.0




                               70.0




                               60.0




                               50.0
           Amplitude in dBµV




                               40.0




                               30.0




                               20.0




                               10.0




                                  0
                                 100.0K      1.0M                        10.0M                                               100.0M
                                                       Frequency in Hz
                                                                                 Project ID: 1-9651/15-01-02




                                                    Page 18 of 21


                                    Test report no.: 1-9651/15-01-02



11    Observations
No observations except those reported with the single test cases have been made.




                                               Page 19 of 21


                                    Test report no.: 1-9651/15-01-02



Annex A         Document history

  Version                                 Applied changes              Date of release

                                            Initial release              2015-06-17




Annex B         Further information
Glossary

AVG        -   Average
DUT        -   Device under test
EMC        -   Electromagnetic Compatibility
EN         -   European Standard
EUT        -   Equipment under test
ETSI       -   European Telecommunications Standard Institute
FCC        -   Federal Communication Commission
FCC ID     -   Company Identifier at FCC
HW         -   Hardware
IC         -   Industry Canada
Inv. No.   -   Inventory number
N/A        -   Not applicable
PP         -   Positive peak
QP         -   Quasi peak
S/N        -   Serial number
SW         -   Software
PMN            Product marketing name
HMN            Host marketing name
HVIN           Hardware version identification number
FVIN           Firmware version identification number




                                               Page 20 of 21


                                          Test report no.: 1-9651/15-01-02



Annex C        Accreditation Certificate


              Front side of certificate                                Back side of certificate




Note:

The current certificate including annex is published on our website (see link below) or may be received
from CETECOM ICT Services on request.


http://www.cetecom.com/eu/de/cetecom-group/europa/deutschland-saarbruecken/akkreditierungen.html




                                                   Page 21 of 21



Document Created: 2015-06-17 15:51:11
Document Modified: 2015-06-17 15:51:11

© 2024 FCC.report