                    ADDENDUM TO RADIO FREQUENCY
                     EXPOSURE REPORT 93870-12A

                                                   FOR THE

                                         Device: DSRC Reader
                                          Model: M215-A2A


                                           Report No.: 93870-12B



                                         Date of issue: August 28, 2013


PREPARED FOR:                                           PREPARED BY:
Raytheon Company                                        EDDIE WONG
Bldg. 675-D241 Dist. Center                             CKC Laboratories, Inc.
1801 Hughes Drive                                       5046 Sierra Pines Drive
Fullerton CA 92834-3310                                 Mariposa, CA 95338


The test data contained in this report documents the observed testing parameters pertaining to and are
relevant for only the sample equipment tested in the agreed upon operational mode(s) and
configuration(s) as identified herein. Compliance assessment remains the client’s responsibility. This
report may not be used to claim product endorsement by A2LA or any government agencies. This test
report has been authorized for release under quality control from CKC Laboratories, Inc.




                                                   Steve Behm
                              Director of Quality Assurance & Engineering Services
                                             CKC Laboratories, Inc.




                                                  Page 1 of 8
                                             Report No: 93870-12B


Purpose:

To demonstrate compliance with United States, Canada and/or European Union RF Exposure requirements for
Portable equipment (devices used ≤20cm from the body) or Mobile equipment (devices used >20cm from the
body) with power output below exemption levels and Mobile equipment, where Maximum Permissible Exposure
(MPE) Calculations apply.

Addendum B: Distance changed from 26cm to 29.8 on page 7.

United States Compliance Requirements (1.1310):


                                       RF Exposure Evaluation Limits
                                     Occupational / Controlled Exposure
Frequency Range        Electric Field       Magnetic Field        Power Density              Averaging Time
(MHz)                  Strength (V/m)       Strength (A/m)        (mW/cm2)                   (minutes)
0.3-3.0                614                    1.63                   *(100)                  6
3.0-30                 1842/f                 4.89/f                 *(900/f2)               6
30-300                 61.4                   0.163                  1                       6
300-1500               ---                    ---                    f/300                   6
1500-100,000           ---                    ---                    5.0                     6


                                      RF Exposure Evaluation Limits
                                General Population / Uncontrolled Exposure
Frequency Range        Electric Field      Magnetic Field       Power Density                Averaging Time
(MHz)                  Strength (V/m)      Strength (A/m)       (mW/cm2)                     (minutes)
0.3-1.34               614                    1.63                   *(100)                  30
1.34-30                824/f                  2.19/f                 *(180/f2)               30
30-300                 27.5                   0.073                  0.2                     30
300-1500               ---                    ---                    f/1500                  30
1500-100,000           ---                    ---                    1.0                     30

* Plane wave equivalent power density
Limit is calculated based on the mid-band frequency used in the operating frequency range.

Exemption Level: Power output <60/fGHz (mW)




                                                  Page 2 of 8
                                             Report No: 93870-12B


Canadian Compliance Requirements (RSS-102):

                                       RF Exposure Evaluation Limits
                                    Occupational / Controlled Exposure:
Frequency Range       Electric Field        Magnetic Field       Power Density   Averaging Time
(MHz)                 Strength (V/m)        Strength (A/m)       (W/m2)          (minutes)
0.003-1.0             600                 4.9                    ---             6
1.0-10                600/f               4.9/f                  ---             6
10-30                 60                  4.9/f                  ---             6
30-300                60                  0.163                  10              6
300-1500              3.54 f0.5           0.0094*f0.5            f/3             6
1500-15,000           137                 0.364                  50              6
15,000-150,000        137                 0.364                  50              616000/f1.2

                                     RF Exposure Evaluation Limits
                               General Population / Uncontrolled Exposure
Frequency Range       Electric Field      Magnetic Field       Power Density     Averaging Time
(MHz)                 Strength (V/m)      Strength (A/m)       (W/m2)            (minutes)
0.003-1.0             280                 2.19                   ---             6
1.0-10                280/f               2.19/f                 ---             6
10-30                 28                  2.19/f                 ---             6
30-300                28                  0.073                  2               6
300-1500              1.585 * f0.5        0.0042 * f0.5          f/150           6
1500-15,000           61.4                0.163                  10              6
15,000-150,000        61.4                0.163                  10              616000/f1.2
*Power density limit applicable >100MHz


Exemption Level:
                      Maximum Output
Frequency Range (MHz) Power
                      (Conducted or EIRP)
0.003-1000            ≤ 200 mW
1000-2200             ≤ 100 mW
2200-3000             ≤ 20 mW
3000-6000             ≤ 10 mW




                                               Page 3 of 8
                                          Report No: 93870-12B


European Union Compliance Requirements (ICNIRP):

                                         RF Exposure Evaluation Limits
                                      Occupational / Controlled Exposure:
Frequency Range         Electric Field        Magnetic Field       Power Density   Averaging Time
(MHz)                   Strength (V/m)        Strength (A/m)       (W/m2)          (minutes)
0.00082-0.065           610                   24.4                   ---           6
0.065-1.0               610                   1.6/f                  ---
1.0-10                  610/f                 1.6/f                  ---           6
10-400                  61                    0.16                   10            6
400-2000                3.0 * f0.5            0.008 * f0.5           f/40          6
2000-300,000            137                   0.36                   50            6

                                       RF Exposure Evaluation Limits
                                 General Population / Uncontrolled Exposure
Frequency Range         Electric Field      Magnetic Field       Power Density     Averaging Time
(MHz)                   Strength (V/m)      Strength (A/m)       (W/m2)            (minutes)
0.003-0.150             87                    5.0                    ---           6
0.150-1.0               87                    0.73/f                 --            6
1.0-10                  87/f0.5               0.73/f                 ---           6
10-400                  28                    0.073                  2             6
400-2000                1.375 f0.5            0.0037*f0.5            f/200         6
2000-300,000            61                    0.16                   10            6
*Power density limit applicable >100MHz


                                          1
Exemption Level: Power output < 20mW




1
    May vary by product type
                                                   Page 4 of 8
                                              Report No: 93870-12B


Device and Antenna Operating Configuration:

     The EUT is placed on the test bench. RS232 port is connected to a support laptop. All other ports
     are left unpopulated for evaluation of RF signal at the antenna port.

     The spectrum analyzer is connected to Port 1 of the EUT. Port 1 thru Port 4 utilizes the same RF
     circuit.

     Digital attenuator set to : 9

     Freq: 905MHz, 915MHz, 925MHz
     Modulation: OOK.

     Measured Peak Power= 29.04dBm, 29.92dBm, 29.18dBm (0.80 W, 0.98W, 0.83W)

     Antenna to be used with this product:
     Sirit, single-element patch antenna , ANTENNA-024, Gain 15 dBi.
     Transcore, Universal Toll Antenna , AA3152       Gain: 14dBi
     European Antennas, flat Panel Antenna, FPA15-916H/1159, Gain 15.4dBi


     Frequency range of measurement = Fundamental
     Test environment conditions: 25°C, 45% Relative Humidity, 100kPa

     The EUT obtains 12V DC power from a support DC Power supply.
     Modification: 0.1uF capacitor added to the T/R control line C196.

     Center frequency was set to 905MHz, 915MHz and 925MHz. The licensee will adjust the transmit
     frequency according to appropriate frequency plan at the time of licensing.

Test Procedure:

     This equipment is evaluated in accordance with the guidelines set forth in OET Guide 65 & ANSI
     C95.1 for the US and Health Canada Safety Code 6 & RSS 102 for Canada.




                                                 Page 5 of 8
                                            Report No: 93870-12B


                                                   MPE Calculations

Applicability:
                                           X            General Population / Uncontrolled Exposure
      Limit Used
                                                        Occupational / Controlled Exposure
                                           Yes          United States
      RF Exposure Exemption                No           Canada
                                           No           Europe


Equipment operational details:

         Config          Operating          Measured             Antenna         Antenna Type /            EIRP
           #             Frequency         Output Power          Gain (dBi)       Configuration           (dBm)
                           (MHz)              (dBm)
             1              915               29.92                15.4               Outdoor             43.32

          Measurements based from EMC Test Report(s): 93870-7

MPE Calculation:
                                           EIRP
                         Power Density               Given: EIRP in mW or W and d in cm or m
                                           4d 2

                                US (1.1310)                    Canada (RSS-102)                      EU (ICNIRP)
Config       Distance       Power         Limit               Power        Limit                 Power         Limit
  #            (cm)        Density      (mW/cm2)             Density      (W/m2)                Density       (W/m2)
                          (mW/cm2)                           (W/m2)                             (W/m2)
  1              20          6.77              3.05           67.72             30.00                --           --


 Minimum Distance of Separation:

 Distance to meet these limits:

   Config #             Freq Range         EIRP             US            Canada                EU
                                           (mW)            (cm)                (m)              (m)
         1               905-925       34040.82           29.802              0.300




                                                        Page 6 of 8
                                                   Report No: 93870-12B


Summary:

Exemptions:
In the case the equipment meets compliance requirements by exemption the product is approved for use under
mobile or portable conditions without further testing under the condition that any additional collocation or
simultaneous transmission requirements (including necessary separation distances) have been met.

MPE Calculation Results:
It is assumed that the manufacturer shall design the equipment such that the minimum separation distance of
29.8cm or greater is met or that the manufacturer provides a protection guide (or installation instructions) to the
end user such that the antenna(s) may be installed in accordance with the manufacturer’s instructions in such a
manor to maintain the minimum separation distance.




                                                   Page 7 of 8
                                              Report No: 93870-12B


References

Federal Communications Commission Knowledge Database (KDB) Publication 447498, “What are the RF exposure
requirements and procedures for mobile and portable devices?” As in effect on the issue date of this report.
Federal Communications Commission Bulletin OET 65 Supplement C, “Evaluating Compliance with FCC Guidelines
for Human Exposure to Radiofrequency Electromagnetic Fields” June 2001
Title 47 Code of Federal Regulations, Part 1.1310, “Radiofrequency radiation exposure limits.” As in effect on the
issue date of this report.
Title 47 Code of Federal Regulations, Part 2.1091, “Radiofrequency radiation exposure evaluation: mobile devices.”
As in effect on the issue date of this report.


Health Canada Safety Code 6 Limits of Human Exposure to Radiofrequency Electromagnetic Energy in the
Frequency Range from 3 kHz to 300 GHz, 2009
Health Canada Safety Code 6 Technical Guide, 2009
Industry Canada RSS-102 Radio Frequency (RF) Exposure Compliance of Radiocommunication Apparatus (All
Frequency Bands) Issue 4, March 2010 (including update December, 2010)


International Commission on Non-Ionizing Radiation Protection. Guidelines for Limiting Exposure to Time-Varying
Electric, Magnetic, and Electromagnetic Fields (up to 300 GHz). Health Physics 74 (4): 494-522; 1998.
International Commission on Non-Ionizing Radiation Protection Statement on the "Guidelines for limiting
exposure to time-varying electric, magnetic and electromagnetic fields (up to 300 GHz). Health Physics 97(3):257-
259; 2009.
European Committee for Electrotechnical Standardization. European Normative, EN 50371 Assessment of the
compliance of low power electronic and electrical equipment with the basic restrictions related to human
exposure to electromagnetic fields (10 MHz to 300 GHz) 2002.




                                                  Page 8 of 8
                                             Report No: 93870-12B



Document Created: 2013-08-28 11:17:02
Document Modified: 2013-08-28 11:17:02

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC