Test Report

FCC ID: PJIL21C0FAL0

Test Report

Download: PDF
FCCID_1970278

                                                                www.etl.re.kt
@—Testing Laboratory




                                      Electromagnetic Emission
           FCC ME ASUREMENT REP ORT
               CERTIFICATION OF COMPLIANCE
                                 FCC Part 15 Certification Measurement

  PRODUCT                                  LCD MONITOR
  MODELITYPE NO                            L21COFALO / NONE
  FCC ID                                   PJIL21COFALO
  MULTIPLE MODEL                           P227D, P227DS, P227DL, P227DT, P227DU, P227DV
  BRAND NAME                              +HYUNDAI
  APPLICANT                                HYUNDAI IBT CORP
                                           106, Apogongdan—gil, Gimcheon—si,
                                          Gyeongsangbuk—do, 740—862, Korea
                                          Attn.: Yoon Suk Lee / Manager
  MANUFACTURER                             HYUNDAI IBT CORP
                                           106, Apogongdan—gil, Gimcheon—si,
                                          Gyeongsangbuk—do, 740—862, Korea
  FCC CLASSIFICATION                      Class B Personal computers and peripherals
  RULE PART(S)                             FCC Part 15 Subpart B & ICES—003 Issue 4
  TEST PROCEDURE                          ANSI C63.4—2003
  TEST REPORT No.                          ETLE130417.0397
  DATES OF TEST                            May 02, 2013 to May 03, 2013
  REPORT ISSUE DATE                       May 16, 2013
  TEST LABORATORY                          ETL Inc. (FCC Designation Number: KROO22, IC OATS Number: 6473B—1)

 This LCD MONITOR, Model L21COFALO has been tested in accordance with the measurement procedures
 specified in ANSI €63.4—2003 at the ETL/EMC Test Laboratory and has been shown to be complied with the
 electromagnetic radiated emission limits specified in FCC Rule Part15 Subpart B & ICES—003 Issue 4:
 1 attest to the accuracy of data. All measurement herein was performed by me or was made under my
 supervision and is correct to the best of my knowledge and belief. | assume full responsibilty for the
 completeness of these measurements and vouch for the qualifications of all persons taking them.
 The results of testing in this report apply to the product/system which was tested only. Other similar
 equipment will not necessarily produce the same results due to production tolerance and measurement
 uncertainties



              Prepared by:%?                                                     Reviewed by: U#
              Jeong Hwan, Pyo (Test Engineer)                                    Hyung Min, Choi (Chief Engineer)
              May 16, 2013                                                       May 16, 2013

                                                               ETL Inc.
                            #371—51, Gasan—dong, Geumcheon—gu, Seoul, 153—803, Korea
                                          Tel: 82—2—858—0786 Fax: 82—2—858—0788
                                           The test report merely corresponds to the test sample(s)
                       This report shall not be reproduced, in whole or in part without the written approval of ETL Inc.


                                          FCC TEST REPORT                                                         FCC ID: PJIL21C0FAL0




                                                         Table of Contents



       FCC Measurement Report

              1. Introduction
              2. Product Information
              3. Description of Tests
              4. Test Condition
              5. Test Results
                  5.1 Summary of Test Results
                  5.2 Conducted Emissions Measurement
                  5.3 Radiated Emissions Measurement
              6. Sample Calculation
              7. List of test Equipment used for Measurement


       Appendix B. Test Setup Photographs
       Appendix C. External Photographs
       Appendix D. Internal Photographs




                                           Report no. ETLE130417.0397, Page 2 of 19
Head Office: # 371-51 Gasan-dong, Geumcheon-gu, Seoul, 153-803, Korea Tel : 82-2-858-0786   Fax : 82-2-858-0788
                                                                                                                           ETLQP-21-F22-0


                                          FCC TEST REPORT                                                         FCC ID: PJIL21C0FAL0




FCC MEASUREMENT REPORT
Scope – Measurement and determination of electromagnetic emission(EME) of radio frequency devices
including intentional radiators and/or unintentional radiators for compliance with the technical rules and
regulations of the U.S Federal Communications Commission(FCC)

General Information



          Applicant Name : HYUNDAI IBT CORP.

          Address                  : 106, Apogongdan-gil, Gimcheon-si,

                                     Gyeongsangbuk-do, 740-862, Korea

          Attention                : Yoon Suk Lee / Manager



            EUT Type :                      LCD MONITOR

            Model Number :                  L21C0FAL0

            S/N :                           -

            Frequency Range :               X-tal  14.318 MHz; F/MEMORY clock  85 kHz;

                                             LVDS clock  74.250 MHz

            Rule Part(s) :                  FCC Part 15 Subpart B & ICES-003 Issue 4

            Test Procedure :                ANSI C63.4-2003

            FCC Classification :            Class B Personal computers and peripherals

            Dates of Tests :                May 02, 2013 to May 03, 2013

            Place of Tests :                ETL Inc. Testing Lab. (FCC Designation Number : KR0022)

                                             Radiated Emission test;
                                             #499-1, Sagot-ri, Seosin-myeon, Hwaseong-si,
                                             Gyeonggi-do, 445-882, Korea

                                             Conducted Emission test;
                                             ETL Inc. Testing Lab. (FCC Designation Number : KR0022)
                                             371-51, Gasan-dong, Geumcheon-gu, Seoul, 153-803, Korea

            Test Report No. :               ETLE130417.0397




                                           Report no. ETLE130417.0397, Page 3 of 19
Head Office: # 371-51 Gasan-dong, Geumcheon-gu, Seoul, 153-803, Korea Tel : 82-2-858-0786   Fax : 82-2-858-0788
                                                                                                                           ETLQP-21-F22-0


                                          FCC TEST REPORT                                                         FCC ID: PJIL21C0FAL0




1. INTRODUCTION
 The measurement tests for radiated and conducted emission test were conducted at the ETL Inc. The site is
constructed in conformance with the requirements of the ANSI C63.4-2003 and CISPR Publication 16. The ETL
has site descriptions on file with the FCC for 3 m and 10 m site configurations. Detailed description of test
facility was found to be in compliance with the requirements of Section 2.948 FCC Rules according to the ANSI
C63.4-2003 and registered to the Federal Communications Commission (FCC Designation Number : KR0022).

The measurement procedure described in American National Standard for Method of Measurement of Radio-
Noise Emission from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz (ANSI
C63.4-2003) was used in determining radiated and conducted emissions from the HYUNDAI IBT CORP., Model:
L21C0FAL0.




                                           Report no. ETLE130417.0397, Page 4 of 19
Head Office: # 371-51 Gasan-dong, Geumcheon-gu, Seoul, 153-803, Korea Tel : 82-2-858-0786   Fax : 82-2-858-0788
                                                                                                                           ETLQP-21-F22-0


                                          FCC TEST REPORT                                                              FCC ID: PJIL21C0FAL0




2. PRODUCT INFORMATION
2.1 Equipment Description

  The Equipment Under Test (EUT) is the LCD MONITOR (model: L21C0FAL0).

  The model L21C0FAL0 is basic model that was tested.

  The model differences are same with below table;

      Model name                 DVI               VGA             Speaker              USB               Lift stand     Tilt stand

    L21C0FAL0                     O                  O                 O                    O                  O             O

    P227D                         O                  O                 X                    X                  X             O

    P227DS                        O                  O                 O                    X                  X             O

    P227DL                        O                  O                 X                    X                  O             X

    P227DT                        O                  O                 O                    X                  O             X

    P227DU                        O                  O                 O                    O                  O             X

    P227DV                        O                  O                 X                    O                  O             X

  * O: Existence, X: Non-existence




                                           Report no. ETLE130417.0397, Page 5 of 19
Head Office: # 371-51 Gasan-dong, Geumcheon-gu, Seoul, 153-803, Korea Tel : 82-2-858-0786       Fax : 82-2-858-0788
                                                                                                                                 ETLQP-21-F22-0


                                          FCC TEST REPORT                                                         FCC ID: PJIL21C0FAL0




2.2 General Specification

                               Item                                                         Specification

                         Visible Screen Area                       476.64 mm (H) x 268.11 mm (V) (21.5 Inch)

                         Pixel Pitch                               0.248 mm (H) x 0.248 mm (V)

                         Recommended Resolution                    1 920 x 1 080 @ 60 Hz

                         Maximum Visible Angle                     170°/170° (H/V)
    LCD
                         Displayed Color                           16.7 M

                         Brightness                                250 cd/m2

                         Contrast Ratio                            1 000:1

                         Response Time                             5 msec

                         Horizontal Frequency                      30 kHz – 80 kHz

                         Vertical Frequency                        60 kHz – 75 kHz
    Input Signal
                         Video Signal                              Analog VGA, DVI

                         Connector                                 DVI-I, AUDIO, USB

                         Power Consumption                         < 25 W (Typ.)

    Power                Stand by Power                            < 0.5 W

                         Input Power                               AC 100 V – 240 V; 50 Hz/60 Hz; 2.0 A

    Multimedia Speakers                                            1Wx2

                                                                   Temperature: (25 ± 15) ℃
                         Operation
    Operating                                                      Humidity: (50 ± 30) % (non-condensing)
    Environment                                                    Temperature: (20 ± 30) ℃
                         Storage
                                                                   Humidity: (50 ± 40) % (non-condensing)




                                           Report no. ETLE130417.0397, Page 6 of 19
Head Office: # 371-51 Gasan-dong, Geumcheon-gu, Seoul, 153-803, Korea Tel : 82-2-858-0786   Fax : 82-2-858-0788
                                                                                                                           ETLQP-21-F22-0


                                          FCC TEST REPORT                                                         FCC ID: PJIL21C0FAL0




3. DESCRIPTION OF TESTS
3.1 Conducted Emission Measurement
 Conducted emissions measurements were made in accordance with section 11, "Measurement of Information
Technology Equipment" of ANSI C63.4-2003. The measurements were performed over the frequency range of
0.15 MHz to 30 MHz using a 50 Ω/50 μH LISN as the input transducer to a Spectrum Analyzer or a Test
Receiver. The measurements were made with the detector set for "Peak" amplitude within a bandwidth of 9 kHz
or for "quasi-peak" within a bandwidth of 9 kHz.


  The line-conducted emission test is conducted inside a shielded anechoic chamber room with 1 m x 1.5 m x
0.8 m wooden table which is placed 40 cm away from the vertical wall and 1.5 m away from the side wall of the
chamber room. Two LISN are bonded to the shielded room. The EUT is powered from the LISN and the support
equipment is powered from the other LISN. Power to the LISNs are filtered by a noise cut power line filters. All
electrical cables are shielded by braided tinned steel tubing with inner  1.2 cm. If the EUT is a DC-powered
device, power will be derived from the source power supply it normally will be powered from and these supply
lines will be connected to the LISN. Non-inductive bundling to a 1 m length shortened all interconnecting cables
more than 1 m. Sufficient time for the EUT, support equipment, and test equipment was allowed in order for
them to warm up to their normal operating condition. The RF output of the LISN was connected to the EMI Test
Receiver to determine the frequency producing the maximum emission from the EUT. The frequency producing
the maximum level was reexamined using to set Quasi-Peak mode by manual, after scanned by automatic Peak
mode from 0.15 MHz to 30 MHz. The bandwidth of the spectrum analyzer was set to 9 kHz. The EUT, support
equipment, and interconnecting cables were arranged and manipulated to maximize each emission.


 Photographs of the worst-case emission can be seen in photographs of conducted emission test setup in
Appendix B.




                                           Report no. ETLE130417.0397, Page 7 of 19
Head Office: # 371-51 Gasan-dong, Geumcheon-gu, Seoul, 153-803, Korea Tel : 82-2-858-0786   Fax : 82-2-858-0788
                                                                                                                           ETLQP-21-F22-0


                                          FCC TEST REPORT                                                         FCC ID: PJIL21C0FAL0




3.2 Radiated Emission Measurement
 Radiated emission measurements were made in accordance with section 11, "Measurement of Information
Technology Equipment" of ANSI C63.4-2003. The measurements were performed over the frequency range of
30 MHz to 40 GHz (or 5th harmonic of the highest frequency) in using antenna as the input transducer to a
spectrum analyzer or a field intensity meter. The measurements below 1 GHz were made with the detector set
for "Quasi-peak" within a bandwidth of 120 kHz. The measurements above 1 GHz were made with the detector
set for "Peak and Average" within a bandwidth of 1 MHz.


 Preliminary measurements were made at 3 m using broadband antennas, and spectrum analyzer to
determined the frequency producing the maximum emission in shielded room. Appropriate precaution was taken
to ensure that all emission from the EUT were maximized and investigated. The system configuration, mode of
operation, turntable azimuth and height with respect to the antenna were noted for each frequency found. The
spectrum was scanned from 30 MHz to 1 000 MHz using Log-Bicon antenna. Above 1 GHz, linearly polarized
double ridge horn antennas were used. Final measurements were made open site at 3 m. The test equipment
was placed on a wooden turn-table. Sufficient time for the EUT, support equipment, and test equipment was
allowed in order for them to warm up to their normal operating condition. Each frequency found during pre-scan
measurements was re-examined by manual. The detector function was set to CISPR Quasi-peak mode and the
bandwidth of the receiver was set to 120 kHz or 1 MHz depending on the frequency of type of signal. The EUT,
support equipment and interconnecting cables were re-configured to the set-up producing the maximum
emission for the frequency and were placed on top of a 0.8 m high nonmetallic 1 m x 1.5 m table. The EUT,
support equipment, and interconnecting cables were re-arranged and manipulated to maximize each emission.
The turntable containing the system was rotated; the antenna height was varied 1 m to 4 m and stopped at the
azimuth or height producing the maximum emission. Each emission was maximized by: varying the mode of
operation to the EUT and/or support equipment and changing the polarity of the antenna, whichever determined
the worst-case emission.


 Photographs of the worst-case emission can be seen in Photographs of the worst-case emission test setup
can be seen in Appendix B.




                                           Report no. ETLE130417.0397, Page 8 of 19
Head Office: # 371-51 Gasan-dong, Geumcheon-gu, Seoul, 153-803, Korea Tel : 82-2-858-0786   Fax : 82-2-858-0788
                                                                                                                           ETLQP-21-F22-0


                                          FCC TEST REPORT                                                            FCC ID: PJIL21C0FAL0




4. TEST CONDITION
4.1 Test Configuration
 The device was configured for testing in a typical fashion (as a customer would normally use it). During the
 tests, the EUT and the supported equipments were installed to meet FCC requirement and operated in a
 manner and which tends to maximize its emission level in a typical application.


4.2 EUT operation
The equipment under test was operated during the measurement under following conditions:

                                                Conditions                                                           Remark

     Standby mode
         The EUT was connected as user’s guide. And during the executed test
                                                                                                            VGA mode & USB mode *
         program for EMI program with "H" pattern display on monitor.
         The EUT was connected as user’s guide. And during the executed test
                                                                                                            DVI mode & USB mode
         program for EMI program with "H" pattern display on monitor.

  * The worst case was investigated for emission test.


4.3 Support Equipment Used

           Description                  Model Name                  Serial No.                    Manufacturer                 FCC

    PC                               D08M                      6GPJXBX                      Dell Inc.                    DoC
                                                                                            Shenzhen Jiayewang
    Keyboard                         IGK-5300                  NONE                                                      -
                                                                                            Technology Co.,Ltd.
                                                                                            Tonzo Industrial Co.,
    Mouse                            MO-2100                   NONE                                                      DoC
                                                                                            Ltd.
    USB Drive (4 GB)                 SUM-BSY4G                 NONE                         Samsung Electronics          -




                                           Report no. ETLE130417.0397, Page 9 of 19
Head Office: # 371-51 Gasan-dong, Geumcheon-gu, Seoul, 153-803, Korea Tel : 82-2-858-0786      Fax : 82-2-858-0788
                                                                                                                               ETLQP-21-F22-0


                                          FCC TEST REPORT                                                                  FCC ID: PJIL21C0FAL0




4.4 Type of Cables Used

                                                                                                                                   Used
       Device from                 Device to              Type of I/O port           Length[m]             Type of shield
                                                                                                                                ferrite core
            EUT                         PC                        VGA                       1.5                Shielded               O

            EUT                         PC                         DVI                      1.5                Shielded               O

            EUT                         PC                   PC Audio In                    1.5                Shielded               O

            EUT                         PC                        USB                       1.2                Shielded               X

            EUT                    USB Drive                      USB                        -                         -              -

            EUT                  Power socket                  AC Input                     1.2              Unshielded               X

             PC                     Keyboard                      USB                       1.2                Shielded               X

             PC                      Mouse                        USB                       1.2                Shielded               X

             PC                  Power socket                  AC Input                     1.2              Unshielded               X




                                          Report no. ETLE130417.0397, Page 10 of 19
Head Office: # 371-51 Gasan-dong, Geumcheon-gu, Seoul, 153-803, Korea Tel : 82-2-858-0786        Fax : 82-2-858-0788
                                                                                                                                    ETLQP-21-F22-0


                                          FCC TEST REPORT                                                         FCC ID: PJIL21C0FAL0




4.5 The setup drawing(s)



               USB Drive




                       EUT                               PC




                                      Keyboard                   Mouse




                          : Signal line
                          : Power line
                          : Adapter




                                          Report no. ETLE130417.0397, Page 11 of 19
Head Office: # 371-51 Gasan-dong, Geumcheon-gu, Seoul, 153-803, Korea Tel : 82-2-858-0786   Fax : 82-2-858-0788
                                                                                                                           ETLQP-21-F22-0


                                          FCC TEST REPORT                                                         FCC ID: PJIL21C0FAL0




5. TEST RESULTS
5.1 Summary of Test Results
The measurement results were obtained with the EUT tested in the conditions described in this report. Detailed
measurement data and plots showing the maximum emission of the EUT are reported.


     FCC Rule                               Measurement Required                                                  Result

      15.107(a)            Conducted Emission Measurement                                          Passed by       6.60 dB


      15.109(a)            Radiated Emission Measurement (Below 1 GHz)                             Passed by       9.30 dB


      15.109(a)            Radiated Emission Measurement (Above 1 GHz)                             N/A *

* The highest frequency of the internal sources of the EUT is less than 108 MHz. This test was measurement made
up to 1 GHz according to the section 15.33 of FCC Part 15.

The data collected shows that the HYUNDAI IBT CORP. / LCD MONITOR / L21C0FAL0 complied with technical
requirements of above rules part 15.107(a) and 15.109(a) Class B Limits.

The equipment is not modified anything, mechanical or circuits to improve EMI status during a measurement.
No EMI suppression device(s) was added and/or modified during testing.




                                          Report no. ETLE130417.0397, Page 12 of 19
Head Office: # 371-51 Gasan-dong, Geumcheon-gu, Seoul, 153-803, Korea Tel : 82-2-858-0786   Fax : 82-2-858-0788
                                                                                                                             ETLQP-21-F22-0


                                          FCC TEST REPORT                                                         FCC ID: PJIL21C0FAL0




5.2 Conducted Emissions Measurement
5.2.1 Conducted Emissions Data

      EUT                                 LCD MONITOR / L21C0FAL0 (S/N: N/A)
      Limit apply to                      FCC Part 15.107(a) Class B
      Test Date                           May 03, 2013
                                          The EUT was connected as user’s guide. And during the executed test
      Operating Condition                 program for EMI program with "H" pattern display on monitor.
                                          (Worst case: VGA mode & USB mode)
      Result                              Passed by 6.60 dB

                                               Conducted Emission Test Data

      The following data and graph shows the highest levels of conducted emissions on both polarizations of
      hot and neutral line.
      Detector mode: CISPR Quasi-Peak mode (6 dB Bandwidth: 9 kHz)

      NOTES:
                  1.    Please see the measured data and graph in next page.
                  2.    The c.f value was included the antenna factor and cable loss.
                  3.    Result value = Reading + c.f
                  4.    Margin = Limit - Result
                  5.    Measurement were performed at the AC Power Inlet in the frequency band of 150 kHz ~ 30 MHz
                        according to the FCC Part 15.107(a) Class B.
                  6.    If the average limit is met when using a Quasi-peak detector receiver, the EUT shall be
                        deemed to meet both limits and measurement with the average detector receiver is
                        unnecessary.




                                          Report no. ETLE130417.0397, Page 13 of 19
Head Office: # 371-51 Gasan-dong, Geumcheon-gu, Seoul, 153-803, Korea Tel : 82-2-858-0786   Fax : 82-2-858-0788
                                                                                                                           ETLQP-21-F22-0


                                          FCC TEST REPORT                                                         FCC ID: PJIL21C0FAL0



Line: HOT




                                          Report no. ETLE130417.0397, Page 14 of 19
Head Office: # 371-51 Gasan-dong, Geumcheon-gu, Seoul, 153-803, Korea Tel : 82-2-858-0786   Fax : 82-2-858-0788
                                                                                                                           ETLQP-21-F22-0


                                          FCC TEST REPORT                                                         FCC ID: PJIL21C0FAL0



Line: Neutral




                                          Report no. ETLE130417.0397, Page 15 of 19
Head Office: # 371-51 Gasan-dong, Geumcheon-gu, Seoul, 153-803, Korea Tel : 82-2-858-0786   Fax : 82-2-858-0788
                                                                                                                           ETLQP-21-F22-0


                                          FCC TEST REPORT                                                             FCC ID: PJIL21C0FAL0



5.3 Radiated Emissions Measurement
5.3.1 Radiated Emissions Data

- Below 1 GHz

     EUT                                 LCD MONITOR / L21C0FAL0 (S/N: N/A)
     Limit apply to                      FCC Part 15.109(a) Class B
     Test Date                           May 02, 2013
                                         The EUT was connected as user’s guide. And during the executed test
     Operating Condition                 program for EMI program with "H" pattern display on monitor.
                                         (Worst case: VGA mode & USB mode)
     Result                              Passed by 9.30 dB

                                                 Radiated Emission Test Data
   The following table shows the highest levels of radiated emissions on both polarizations of horizontal and vertical.
    Detector mode: CISPR Quasi-Peak mode (6 dB Bandwidth: 120 kHz)


      Frequency           Reading        Polarization Ant. Factor Cable Loss  Result      Limit                              Margin
        [MHz]             [dB(μV)]        (*H/**V)      [dB/m]     [dB(μV)] [dB(μV/m)] [dB(μV/m)]                             [dB]

          40.90             17.01               V              11.91             1.38          30.30              40.00       9.70

          53.18             17.06               V              12.21             1.43          30.70              40.00       9.30

         120.67             18.24               V              11.30             1.86          31.40              43.50       12.10

         177.94             13.85               V              11.69             2.16          27.70              43.50       15.80

         296.53             11.51              H               13.21             2.68          27.40              46.00       18.60

     NOTES:
                  1.    * H : Horizontal polarization , ** V : Vertical polarization
                  2.    Result = Reading + Antenna factor + Cable loss
                  3.    Margin value = Limit - Result
                  4.    The measurement was performed for the frequency range 30 MHz ~ 1 000 MHz according to
                        the FCC Part 15.109(a) Class B.
                  5.    The highest frequency of the internal sources of the EUT is less than 108 MHz. This test was
                        measurement made up to 1 GHz according to the section 15.33 of FCC Part 15.




                                          Report no. ETLE130417.0397, Page 16 of 19
Head Office: # 371-51 Gasan-dong, Geumcheon-gu, Seoul, 153-803, Korea Tel : 82-2-858-0786   Fax : 82-2-858-0788
                                                                                                                               ETLQP-21-F22-0


                                          FCC TEST REPORT                                                         FCC ID: PJIL21C0FAL0




                                                                                                                       : Limit




  Quasi-peak




                                          Report no. ETLE130417.0397, Page 17 of 19
Head Office: # 371-51 Gasan-dong, Geumcheon-gu, Seoul, 153-803, Korea Tel : 82-2-858-0786   Fax : 82-2-858-0788
                                                                                                                           ETLQP-21-F22-0


                                          FCC TEST REPORT                                                         FCC ID: PJIL21C0FAL0




6. SAMPLE CALCULATION
   Sample Field Strength Calculation

      The field strength is calculated by adding the Antenna Factor and Cable Factor.
      The basic equation with a sample calculation is as follows:

           FS = RA + AF + CF - PA

           Where FS = Field Strength
                 RA = Receiver Amplitude
                 AF = Antenna Factor
                 CF = Cable Attenuation Factor
                 PA* = Preamplifier Factor

           * PA is only be used for the measuring frequency above 1 GHz.



            dB(μV) = 20 log10 (μV) : Equation
            dB(μV) = dBm + 107

   Example         : @ 53.18 MHz



                      Class B Limit             = 40.00 dB(μV/m)

                      Reading                   = 17.06 dB(μV)

                      Antenna Factor + Cable Loss                      = 12.21 + 1.43 = 13.64 dB(μV/m)

                                      Total                            = 30.70 dB(μV/m)

                      Margin                    = 40.00 – 30.70 = 9.30 dB

                                                = 9.30 dB below Limit




                                          Report no. ETLE130417.0397, Page 18 of 19
Head Office: # 371-51 Gasan-dong, Geumcheon-gu, Seoul, 153-803, Korea Tel : 82-2-858-0786   Fax : 82-2-858-0788
                                                                                                                           ETLQP-21-F22-0


                                          FCC TEST REPORT                                                         FCC ID: PJIL21C0FAL0




7. List of test equipments used for measurements
                                                                                                                               Cal. Due
             Test Equipment                          Model                      Mfg.               Serial No.     Cal. Date
                                                                                                                                Date

               EMI Test Receiver                    ESVS 10                     R&S               835165/001      13.03.18     14.03.18

               EMI Test Receiver                     ESPI3                      R&S                  100478       12.09.05     13.09.05

              Two-Line V-Network                    ENV216                      R&S               958599/106      13.03.19     14.03.19

                       LISN                          3816-2                    EMCO                   1002        12.09.05     13.09.05

              LogBicon Antenna                    VULB9160                 Schwarzbeck                3128        12.02.22     14.02.22

                    Turn-Table                     TT 1.35 SI                   SES                      -          N/A           N/A

                Antenna Master                       AM 4.5                     SES                      -          N/A           N/A




                                          Report no. ETLE130417.0397, Page 19 of 19
Head Office: # 371-51 Gasan-dong, Geumcheon-gu, Seoul, 153-803, Korea Tel : 82-2-858-0786   Fax : 82-2-858-0788
                                                                                                                              ETLQP-21-F22-0



Document Created: 2019-11-11 05:45:21
Document Modified: 2019-11-11 05:45:21

© 2024 FCC.report