MPE

FCC ID: PJ8-WIL6110

RF Exposure Info

Download: PDF
FCCID_1875357

REPORT NO: 12U14649-1C                                                        DATE: January 2, 2013
FCC ID: PJ8-WIL6110                                                           IC: 10579A-WIL86110


8. RF EXPOSURE

FCC RULES

§1.1310 The criteria listed in Table 1 shall be used to evaluate the environmental impact of
human exposure to radio-frequency (RF) radiation as specified in §1.1307(b), except in the case
of portable devices which shall be evaluated according to the provisions of §2.1093 of this
chapter.




                                         Page 36 of 42
UL CCS                                                                      FORM NO: CCSUP4701F
47173 BENICIA STREET, FREMONT, CA 94538, USA          TEL: (510) 771-1000      FAX: (510) 661-0888
   This report shall not be reproduced except in full, without the written approval of UL CCS.


REPORT NO: 12U14649-1C                                                        DATE: January 2, 2013
FCC ID: PJ8-WIL6110                                                           IC: 10579A-WIL86110


IC RULES

IC Safety Code 6, Section 2.2.1 (a) A person other than an RF and microwave exposed worker
shall not be exposed to electromagnetic radiation in a frequency band listed in Column 1 of
Table 5, if the field strength exceeds the value given in Column 2 or 3 of Table 5, when
averaged spatially and over time, or if the power density exceeds the value given in Column 4 of
Table 5, when averaged spatially and over time.




                                         Page 37 of 42
UL CCS                                                                      FORM NO: CCSUP4701F
47173 BENICIA STREET, FREMONT, CA 94538, USA          TEL: (510) 771-1000      FAX: (510) 661-0888
   This report shall not be reproduced except in full, without the written approval of UL CCS.


REPORT NO: 12U14649-1C                                                        DATE: January 2, 2013
FCC ID: PJ8-WIL6110                                                           IC: 10579A-WIL86110


CALCULATIONS



EIRP is converted to Power Density using the equation:

PD = EIRP / (4 * Pi * DS^2)

where:

PD = power density in W/m^2
EIRP = Equivalent Isotropic Radiated Power in W
DS = separation distance in m
Power density in units of W/m^2 is converted to units of mW/cm^2 by dividing by 10.


RESULTS



Channel 2
Average Average Separation Power      IC     Power     FCC
  EIRP    EIRP   Distance Density Limit      Density   Limit
 (dBm)     (W)     (cm)    (W/m^2) (W/m^2) (mW/cm^2) (mW/cm^2)
  25.3    0.339     20       0.67    10       0.07       1

Channel 3
Average Average Separation            Power         IC        Power             FCC

   EIRP      EIRP       Distance      Density Limit    Density   Limit
  (dBm)       (W)         (cm)       (W/m^2) (W/m^2) (mW/cm^2) (mW/cm^2)

   24.4      0.275         20          0.55         10          0.05              1




                                         Page 38 of 42
UL CCS                                                                      FORM NO: CCSUP4701F
47173 BENICIA STREET, FREMONT, CA 94538, USA          TEL: (510) 771-1000      FAX: (510) 661-0888
   This report shall not be reproduced except in full, without the written approval of UL CCS.



Document Created: 2019-09-24 10:09:26
Document Modified: 2019-09-24 10:09:26

© 2024 FCC.report