Report No.                      :      AL010174-001                                                          Date :             2009-04-21

Application No.                 :      LL202500(9)

Applicant                       :      Mattel Asia Pacific Sourcing Ltd.
                                       1301, South Tower, World Finance Center,
                                       Harbour City, Tsim Sha Tsui,
                                       Hong Kong.

Sample Description :                   One (1) submitted sample(s) stated to be Barbie® Corvette® & Doll
                                       of Model No. P3494
                                       Radio Frequency         : 27.145MHz Transmitter
                                       Rating                  : 1 x 9V size battery
                                       No. of submitted sample : Three (3) piece(s)


Date Received                   :      2009-03-13.


Test Period                     :      2009-03-14 to 2009-03-23.


Test Requested                  :      FCC Part 15 Certification.


Test Method                     :      47 CFR Part 15 (10-1-08 Edition)
                                       ANSI C63.4 – 2003


Test Result                     :      See attached sheet(s) from page 2 to 11.


Conclusion                      :      The submitted sample was found to comply with requirement of FCC Part 15
                                       Subpart C.


                                             For and on behalf of
                                             CMA Industrial Development Foundation Limited




Authorized Signature : ____________________________________________________
                                   Mr. Wong Lap-pong, Andrew
                                        Assistant Manager
                                        Electrical Division
                                                                                                                                                 Page 1 of 11
FCC ID: PIYP3494-09A2T

 This document is issued subject to CMA Testing standard TEARMS AND CONDITIONS, and shall not be reproduced except in full or with written approval by CMA Testing.
                                          CMA Industrial Development Foundation Limited
                                 Room 1302, Yan Hing Centre, 9-13 Wong Chuk Yeung St.., Fo Tan, Shatin, Hong Kong.
                        Tel: (852) 2698 8198 Fax: (852) 2695 4177 E-mail: info@cmatcl.com Web Site: http://www.cmatcl.com


                                                               TEST REPORT

Report No.                      :     AL010174-001                                                          Date :             2009-04-21



                                                                  Table of Contents


1      General Information.............................................................................................................................3
    1.1    General Description .....................................................................................................................3
    1.2    Location of the test site................................................................................................................4
    1.3    List of measuring equipment .......................................................................................................5
2      Description of the radiated emission test.............................................................................................6
    2.1    Test Procedure .............................................................................................................................6
    2.2    Test Result ...................................................................................................................................6
    2.3    Radiated Emission Measurement Data........................................................................................7
3      Description of the Line-conducted Test ..............................................................................................8
    3.1    Test Procedure .............................................................................................................................8
    3.2    Test Result ...................................................................................................................................8
    3.3    Graph and Table of Conducted Emission Measurement Data ....................................................8
4      Photograph...........................................................................................................................................9
    4.1    Photographs of the Test Setup for Radiated Emission and Conducted Emission .......................9
    4.2    Photographs of the External and Internal Configurations of the EUT ........................................9
5      Supplementary document ..................................................................................................................10
    5.1    Bandwidth..................................................................................................................................10
    5.2    Duty cycle ..................................................................................................................................10
    5.3    Transmission time......................................................................................................................10
6      Appendices ........................................................................................................................................11




                                                                                                                                                Page 2 of 11
FCC ID: PIYP3494-09A2T

This document is issued subject to CMA Testing standard TEARMS AND CONDITIONS, and shall not be reproduced except in full or with written approval by CMA Testing.
                                         CMA Industrial Development Foundation Limited
                                 Room 1302, Yan Hing Centre, 9-13 Wong Chuk Yeung St.., Fo Tan, Shatin, Hong Kong.
                        Tel: (852) 2698 8198 Fax: (852) 2695 4177 E-mail: info@cmatcl.com Web Site: http://www.cmatcl.com


                                                                TEST REPORT

Report No.                      :      AL010174-001                                                          Date :             2009-04-21


1        General Information

1.1      General Description

         The equipment under test (EUT) is a transmitter for Barbie® Corvette® & Doll. It operates at
         27.145MHz and the oscillation of radio control is generated by a crystal. The EUT is powered by
         1 x 9V size battery. There are two buttons on the EUT. When the forward or backward button is
         pressed, it will transmit different radio control signal to the receiver.

         The antenna is permanently attached in EUT and the radio output power is unable to adjust.

         The brief circuit description is listed as follows:

           -      Q1, Q2 and associated circuit act as an encoder.
           -      Q3, Y1 and associated circuit act as an oscillator.




                                                                                                                                                 Page 3 of 11
FCC ID: PIYP3494-09A2T

 This document is issued subject to CMA Testing standard TEARMS AND CONDITIONS, and shall not be reproduced except in full or with written approval by CMA Testing.
                                          CMA Industrial Development Foundation Limited
                                 Room 1302, Yan Hing Centre, 9-13 Wong Chuk Yeung St.., Fo Tan, Shatin, Hong Kong.
                        Tel: (852) 2698 8198 Fax: (852) 2695 4177 E-mail: info@cmatcl.com Web Site: http://www.cmatcl.com


                                                                TEST REPORT

Report No.                      :      AL010174-001                                                          Date :             2009-04-21


1.2      Location of the test site

Radiated emissions measurements are investigated and taken pursuant to the procedures of ANSI C63.4 –
2003. A Semi-Anechoic Chamber Testing Site is set up for investigation and located at:



                                                       Ground Floor, Yan Hing Centre,
                                                       9 – 13 Wong Chuk Yeung Street,
                                                               Fo Tan, Shatin,
                                                               New Territories,
                                                                Hong Kong.


Conducted emissions measurements are investigated and also taken pursuant to the procedures of ANSI
C63.4 – 2003. A shielded room is located at :

                                                        Ground Floor, Yan Hing Centre,
                                                       9 – 13 Wong Chuk Yeung Street,
                                                                     Fo Tan, Shatin,
                                                                     New Territories,
                                                                        Hong Kong.




                                                                                                                                                 Page 4 of 11
FCC ID: PIYP3494-09A2T

 This document is issued subject to CMA Testing standard TEARMS AND CONDITIONS, and shall not be reproduced except in full or with written approval by CMA Testing.
                                          CMA Industrial Development Foundation Limited
                                 Room 1302, Yan Hing Centre, 9-13 Wong Chuk Yeung St.., Fo Tan, Shatin, Hong Kong.
                        Tel: (852) 2698 8198 Fax: (852) 2695 4177 E-mail: info@cmatcl.com Web Site: http://www.cmatcl.com


                                                                TEST REPORT

Report No.                      :      AL010174-001                                                          Date :             2009-04-21


1.3      List of measuring equipment

              Equipment                        Manufacturer                  Model No.                  Serial No.             Calibration Due Date
       EMI Test Receiver                              R&S                        ESCI                     100152                 2009 December 02
           Bilog Antenna                           Schaffner                 CBL6112B                       2718                   2010 August 04
           Loop Antenna                             EMCO                          6502                  00056620                      2009 July 18




                                                                                                                                                 Page 5 of 11
FCC ID: PIYP3494-09A2T

 This document is issued subject to CMA Testing standard TEARMS AND CONDITIONS, and shall not be reproduced except in full or with written approval by CMA Testing.
                                          CMA Industrial Development Foundation Limited
                                 Room 1302, Yan Hing Centre, 9-13 Wong Chuk Yeung St.., Fo Tan, Shatin, Hong Kong.
                        Tel: (852) 2698 8198 Fax: (852) 2695 4177 E-mail: info@cmatcl.com Web Site: http://www.cmatcl.com


                                                                TEST REPORT

Report No.                      :      AL010174-001                                                          Date :             2009-04-21


2        Description of the radiated emission test

2.1      Test Procedure

         Radiated emissions measurements are investigated and taken pursuant to the procedures of ANSI
         C63.4 – 2003.

         The equipment under test (EUT) was placed on a non-conductive turntable with dimensions of
         1.5m x 1m and 0.8m high above the ground. 3m from the EUT, a broadband antenna mounting on
         the mast received the signal strength. The turntable was rotated to maximize the emission level.
         The antenna was then moving along the mast from 1m up to 4m until no more higher value was
         found. Both horizontal and vertical polarization of the antenna were placed and investigated.

         For below 30MHz, a loop antenna with its vertical plane is placed 3m from the EUT and rotated
         about its vertical axis for maximum response at each azimuth about the EUT. And the centre of the
         loop shall be 1 m above the ground.

         The device was rotated through three orthogonal axes to determine which attitude and
         configuration produce the highest emission during measurement.


2.2      Test Result

         Peak Detector data was measured unless otherwise stated.

         “#” means emissions appearing within the restricted bands shall follow the requirement of section
         15.205.

         The frequencies from fundamental up to the tenth harmonics were investigated, and emissions
         more 20dB below limit were not reported. Thus, those highest emissions were presented in next
         page (section 2.3)

         It was found that the EUT meet the FCC requirement.




                                                                                                                                                 Page 6 of 11
FCC ID: PIYP3494-09A2T

 This document is issued subject to CMA Testing standard TEARMS AND CONDITIONS, and shall not be reproduced except in full or with written approval by CMA Testing.
                                          CMA Industrial Development Foundation Limited
                                 Room 1302, Yan Hing Centre, 9-13 Wong Chuk Yeung St.., Fo Tan, Shatin, Hong Kong.
                        Tel: (852) 2698 8198 Fax: (852) 2695 4177 E-mail: info@cmatcl.com Web Site: http://www.cmatcl.com


                                                                TEST REPORT

Report No.                      :      AL010174-001                                                          Date :             2009-04-21


2.3      Radiated Emission Measurement Data


                                                                  Radiated emission

                                                                        pursuant to

                                              the requirement of FCC Part 15 subpart C



  Frequency             Polarity         Reading at Antenna and                      Average             Field              Limit at 3m             Margin
    (MHz)                (H/V)              3m      Cable factor                      Factor            Strength            (dBµV/m)                 (dB)
                                         (dBµV/m)      (dB)                            (dB)            (dBµV/m)
      27.145                V               66.2        9.2                             -5.4              70.0                    80.0                -10.0
   #135.713                 H                14.8                   12.6                   -                27.4                  43.5                -16.1
   #244.236                 H                18.4                   10.3                   -                28.7                  46.0                -17.3
   #271.356                 H                15.3                   14.1                   -                29.4                  46.0                -16.6
      298.482               H                15.7                   14.1                   -                29.8                  46.0                -16.2
   #325.611                 H                17.4                   15.9                   -                33.3                  46.0                -12.7
      352.735               H                19.8                   15.9                   -                35.7                  46.0                -10.3
      379.872               H                20.2                   15.9                   -                36.1                  46.0                 -9.9
      434.244               H                14.7                   19.4                   -                34.1                  46.0                -11.9
      461.376               H                13.5                   19.4                   -                32.9                  46.0                -13.1




                                                                                                                                                 Page 7 of 11
FCC ID: PIYP3494-09A2T

 This document is issued subject to CMA Testing standard TEARMS AND CONDITIONS, and shall not be reproduced except in full or with written approval by CMA Testing.
                                          CMA Industrial Development Foundation Limited
                                 Room 1302, Yan Hing Centre, 9-13 Wong Chuk Yeung St.., Fo Tan, Shatin, Hong Kong.
                        Tel: (852) 2698 8198 Fax: (852) 2695 4177 E-mail: info@cmatcl.com Web Site: http://www.cmatcl.com


                                                                TEST REPORT

Report No.                      :      AL010174-001                                                          Date :             2009-04-21


3        Description of the Line-conducted Test

3.1      Test Procedure

         Conducted emissions measurements are investigated and also taken pursuant to the procedures of
         ANSI C63.4 – 2003. The EUT was setup as described in the procedures, and both lines were
         measured.

3.2      Test Result

         No measurement is required as the EUT is a battery-operated product.

3.3      Graph and Table of Conducted Emission Measurement Data

         Not Applicable




                                                                                                                                                 Page 8 of 11
FCC ID: PIYP3494-09A2T

 This document is issued subject to CMA Testing standard TEARMS AND CONDITIONS, and shall not be reproduced except in full or with written approval by CMA Testing.
                                          CMA Industrial Development Foundation Limited
                                 Room 1302, Yan Hing Centre, 9-13 Wong Chuk Yeung St.., Fo Tan, Shatin, Hong Kong.
                        Tel: (852) 2698 8198 Fax: (852) 2695 4177 E-mail: info@cmatcl.com Web Site: http://www.cmatcl.com


                                                                TEST REPORT

Report No.                      :      AL010174-001                                                          Date :             2009-04-21


4        Photograph

4.1      Photographs of the Test Setup for Radiated Emission and Conducted Emission

         For electronic filing, the photos are saved with filename TSup1.jpg to TSup2.jpg.

4.2      Photographs of the External and Internal Configurations of the EUT

         For electronic filing, the photos are saved with filename ExPho1.jpg to ExPho2.jpg and InPho1.jpg
         to InPho2.jpg.




                                                                                                                                                 Page 9 of 11
FCC ID: PIYP3494-09A2T

 This document is issued subject to CMA Testing standard TEARMS AND CONDITIONS, and shall not be reproduced except in full or with written approval by CMA Testing.
                                          CMA Industrial Development Foundation Limited
                                 Room 1302, Yan Hing Centre, 9-13 Wong Chuk Yeung St.., Fo Tan, Shatin, Hong Kong.
                        Tel: (852) 2698 8198 Fax: (852) 2695 4177 E-mail: info@cmatcl.com Web Site: http://www.cmatcl.com


                                                                TEST REPORT

Report No.                      :      AL010174-001                                                          Date :             2009-04-21


5        Supplementary document

         The following document were submitted by applicant, and for electronic filing, the document are
         saved with the following filenames:

                                 Document                                                                   Filename
                             ID Label/Location                                                             LabelSmp.jpg
                              Block Diagram                                                                 BlkDia.pdf
                            Schematic Diagram                                                               Schem.pdf
                               Users Manual                                                                UserMan.pdf
                           Operational Description                                                          OpDes.pdf

5.1      Bandwidth

         The plot on saved in TestRpt2.pdf shows the fundamental emission is confined in the specified
         band. It also shows that the band edge met the 15.209 requirement at 26.9599 and 27.2801 MHz.


5.2      Duty cycle

         The duty cycle is simply the on-time divided by the period:

         The duration of one cycle                             =      1.13ms

         Effective period of the cycle                         =      0.61ms

         Duty Cycle                                            =      0.61ms / 1.13ms
                                                               =      0.54

         Therefore, the average factor is found by 20 log10 0.54 = -5.4dB



5.3      Transmission time

         Not Applicable




                                                                                                                                               Page 10 of 11
FCC ID: PIYP3494-09A2T

 This document is issued subject to CMA Testing standard TEARMS AND CONDITIONS, and shall not be reproduced except in full or with written approval by CMA Testing.
                                          CMA Industrial Development Foundation Limited
                                 Room 1302, Yan Hing Centre, 9-13 Wong Chuk Yeung St.., Fo Tan, Shatin, Hong Kong.
                        Tel: (852) 2698 8198 Fax: (852) 2695 4177 E-mail: info@cmatcl.com Web Site: http://www.cmatcl.com


                                                               TEST REPORT

Report No.                     :      AL010174-001                                                          Date :             2009-04-21


6       Appendices

          A1.          Photos of the set-up of Radiated Emissions                                     1            page
          A2.          Photos of External Configurations                                              1            page
          A3.          Photos of Internal Configurations                                              1            page
          A4.          ID Label/Location                                                              1            page
          A5.          Bandwidth Plot                                                                 1            page
          A6.          Average Factor                                                                 1            page
          A7.          Block Diagram                                                                  1            page
          A8.          Schematics Diagram                                                             1            page
          A9.          User Manual                                                                    3            pages
          A10.         Operation Description                                                          1            page


                                                           ***** End of Report *****




                                                                                                                                              Page 11 of 11
FCC ID: PIYP3494-09A2T

This document is issued subject to CMA Testing standard TEARMS AND CONDITIONS, and shall not be reproduced except in full or with written approval by CMA Testing.
                                         CMA Industrial Development Foundation Limited
                                Room 1302, Yan Hing Centre, 9-13 Wong Chuk Yeung St.., Fo Tan, Shatin, Hong Kong.
                       Tel: (852) 2698 8198 Fax: (852) 2695 4177 E-mail: info@cmatcl.com Web Site: http://www.cmatcl.com



Document Created: 2009-04-21 12:31:50
Document Modified: 2009-04-21 12:31:50

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC