CBSD-SAS report

FCC ID: PIDAH4200

Test Report

Download: PDF
FCCID_4244493

DEKRA Certification, Inc.
405, Glenn Drive Suite 12
Sterling, Virginia, USA




                                                                                      Test report No:
                                                                                   NIE: 02297RCB.004


          Test report
          Citizen Broadband Radio Service Test report as per
          WINNForum Test Specification WINNF-TS-0122-V1.0.0
           Identification of item tested               AirHarmony 4200 3550-3700MHz (B48)


           Trademark                                   Not Provided


           Model and /or type reference                AirHarmony 4200, LTE-TDD Base Station, CBSD


           Other identification of the product         Not Provided

           Features                                    CBSD, Domain Proxy, LTE-TDD 48


           Manufacturer                                AIRSPAN NETWORK INC
                                                       777 YAMATO ROAD SUIT 310
                                                       BOCA RATON, FLORIDA – 33431
                                                       UNITE STATES OF AMERICA
           CBSD Final HW version                       C2
           CBSD Final SW version                       SR16.00
           Domain Proxy Final SW version               SR16.50
           Domain Proxy Final HW version               NA
           Test method requested, standard             WinnForum TEST SPECIFICATION WINNF-TS-0122-
                                                       V1.0.0

           Summary                                     IN COMPLIANCE


           Approved by (name / position & signature)   Bryan Mikesh, Chief Operating Officer, DEKRA
                                                       Certification Inc.




           Date of issue                               2019-03-28


           Report template No                          FDT08_21




Report No: (NIE)                                                                                        2019-03-28
02297RCB.004


DEKRA Certification, Inc.
405, Glenn Drive Suite 12
Sterling, Virginia, USA




    Index
    Competences and guarantees .................................................................................................... 3
    General conditions ...................................................................................................................... 3
    Uncertainty ................................................................................................................................. 4
    Data provided by the client.......................................................................................................... 4
    Usage of samples ....................................................................................................................... 4
    Identification of the client............................................................................................................. 4
    Testing period and place ............................................................................................................. 4
    Document history ........................................................................................................................ 4
    Remarks and comments ............................................................................................................. 4
    Testing verdicts........................................................................................................................... 5
    Summary .................................................................................................................................... 5
    Appendix A: Test Results ............................................................................................................ 6
    Appendix B: Test Systems ........................................................................................................ 11
    Test System Used..................................................................................................................... 12
    Appendix C: CBSD/ DP Supported Features ............................................................................ 13
    Supported Features .................................................................................................................. 14
    Appendix D: Reference Standards and Procedures .................................................................. 15




 Report No: (NIE)                                                     Page 2 of 16                                                            2019-03-28
 02297RCB.004


DEKRA Certification, Inc.
405, Glenn Drive Suite 12
Sterling, Virginia, USA



Competences and guarantees
    DEKRA Certification Inc. is a testing laboratory accredited by A2LA (The American Association for Laboratory
    Accreditation), to perform the tests indicated in the Certificate 2764.01.
    DEKRA Certification, Inc. is a CTIA authorized testing laboratory with lab code 20131104-01.
    DEKRA Certification, Inc. is a CBRS Alliance authorized test laboratory.
    DEKRA Certification, Inc. is a WInnForum Approved CBSD test laboratory.
    In order to assure the traceability to other national and international laboratories, DEKRA Certification, Inc. has
    a calibration and maintenance program for its measurement equipment.
    DEKRA Certification, Inc. guarantees the reliability of the data presented in this report, which is the result of the
    measurements and the tests performed to the item under test on the date and under the conditions stated on
    the report and, it is based on the knowledge and technical facilities available at DEKRA Certification, Inc. at the
    time of performance of the test.
    DEKRA Certification, Inc. is liable to the client for the maintenance of the confidentiality of all information related
    to the item under test and the results of the test.
    The results presented in this Test Report apply only to the particular item under test established in this
    document.
    IMPORTANT: No parts of this report may be reproduced or quoted out of context, in any form or by any means,
    except in full, without the previous written permission of DEKRA Testing and Certification.


General conditions
         1. This report is only referred to the item that has undergone the test.
         2. This report does not constitute or imply on its own an approval of the product by the Certification Bodies
            or competent Authorities.
         3. This document is only valid if complete; no partial reproduction can be made without previous written
            permission of DEKRA Testing and Certification.
         4. This test report cannot be used partially or in full for publicity and/or promotional purposes without
            previous written permission of DEKRA Testing and Certification and the Accreditation Bodies.




 Report No: (NIE)                                       Page 3 of 16                                            2019-03-28
 02297RCB.004


DEKRA Certification, Inc.
405, Glenn Drive Suite 12
Sterling, Virginia, USA




Uncertainty
    Uncertainty (factor k=2) was calculated according to the DEKRA Testing and Certification internal document
    PODT000.


Data provided by the client
    DEKRA declines any responsibility with respect to the information provided by the client and that may affect the
    validity of results.


Usage of samples
    Samples undergoing test have been selected by: Airspan Network, Inc.
    Sample M/01 is composed of the following elements:

       Control Nº                 Description                       Model           Serial Nº       Date of reception

        02297.004                      CBSD                      AirHarmony     D5EF17CE65D4           2018-12-10
                                                                     4200

             NA             Domain Proxy Software                  Netspan            NA               2018-12-10

         1. Sample M/01 has undergone the test(s) specified in subclause “Test method requested”.


Identification of the client
AIRSPAN NETWORK INC
777 YAMATO ROAD SUIT 310, BOCA RATON, FLORIDA – 33431
UNITE STATES OF AMERICA


Testing period and place
       Test Location          DEKRA Certification, Inc.
         Date (start)         2018-12-10
        Date (finish)         2018-12-12


Document history
    Report number               Date                                          Description

  02297RCB.004              2019-03-26        First release




Remarks and comments
1: The tests have been performed by the technical personnel: Indusha, Chitepu



 Report No: (NIE)                                             Page 4 of 16                                    2019-03-28
 02297RCB.004


DEKRA Certification, Inc.
405, Glenn Drive Suite 12
Sterling, Virginia, USA



Testing verdicts

                            Not applicable :                      N/A

                            Pass     :                            P

                            Fail     :                            F

                            Not measured :                        N/M




Summary

 Standard :                        WINNF-TS-0122
 Band :                            TDD 48
            Total                   PASS VERDICT
              32                            32




 Report No: (NIE)                                  Page 5 of 16         2019-03-28
 02297RCB.004


DEKRA Certification, Inc.
405, Glenn Drive Suite 12
Sterling, Virginia, USA




      Appendix A: Test Results




 Report No: (NIE)           Page 6 of 16   2019-03-28
 02297RCB.004


DEKRA Certification, Inc.
405, Glenn Drive Suite 12
Sterling, Virginia, USA


                                                                                                     CBSD      CBSD
   Test                                                                  Test               SAS                            DP SW
                  Ref           Name           Condition     Date                 Result              SW        HW
   Spec                                                                 sample             version                         Version
                                                                                                     Version   Version
  WINNF
                            Domain Proxy                                                             SR16.00
    -TS-     WINNF.FT.D                                                 02297.0
   0122-       .REG.2
                             Multi-Step         Normal     12/10/2018
                                                                          04
                                                                                  PASS     1.0.0.2               C2         SR16.50
                             registration
  V1.0.0


                            Domain Proxy
  WINNF
                              Single-Step                                                            SR16.00
    -TS-     WINNF.FT.D                                                 02297.0
   0122-       .REG.6
                            registration for    Normal     12/10/2018
                                                                          04
                                                                                  PASS     1.0.0.2               C2         SR16.50
                            CBSD with CPI
  V1.0.0
                              signed data



                            Domain Proxy
  WINNF                         Missing
    -TS-     WINNF.FT.D        Required                                 02297.0                      SR16.00
   0122-       .REG.9         parameters
                                                Normal     12/10/2018
                                                                          04
                                                                                  PASS     1.0.0.2               C2         SR16.50
  V1.0.0                    (responseCode
                                 102)


                            Domain Proxy
  WINNF
                                Pending                                                              SR16.00
    -TS-     WINNF.FT.D                                                 02297.0
   0122-      .REG.11
                              registration      Normal     12/10/2018
                                                                          04
                                                                                  PASS     1.0.0.2               C2         SR16.50
                            (responseCode
  V1.0.0
                                 200)


                            Domain Proxy
  WINNF
                                Invalid                                                              SR16.00
    -TS-     WINNF.FT.D                                                 02297.0
   0122-      .REG.13
                              parameters        Normal     12/10/2018
                                                                          04
                                                                                  PASS     1.0.0.2               C2         SR16.50
                            (responseCode
  V1.0.0
                                 103)


                            Domain Proxy
  WINNF
                              Blacklisted                                                            SR16.00
    -TS-     WINNF.FT.D                                                 02297.0
   0122-      .REG.15
                                CBSD            Normal     12/10/2018
                                                                          04
                                                                                  PASS     1.0.0.2               C2         SR16.50
                            (responseCode
  V1.0.0
                                 101)



                            Domain Proxy
  WINNF                      Unsupported
    -TS-     WINNF.FT.D     SAS protocol                                02297.0                      SR16.00
   0122-      .REG.17          version
                                                Normal     12/10/2018
                                                                          04
                                                                                  PASS     1.0.0.2               C2         SR16.50
  V1.0.0                    responseCode
                                100)



  WINNF                     Domain Proxy
    -TS-     WINNF.FT.D       Group Error                               02297.0                      SR16.00
   0122-      .REG.19       (responseCode
                                                Normal     12/10/2018
                                                                          04
                                                                                  PASS     1.0.0.2               C2         SR16.50
  V1.0.0                         201)


                              Unsuccessful
  WINNF                          Grant
    -TS-     WINNF.FT.D     responseCode=4                              02297.0                      SR16.00
   0122-       .GRA.1             00
                                                Normal     12/11/2018
                                                                          04
                                                                                  PASS     1.0.0.2               C2         SR16.50
  V1.0.0                    (INTERFEREN
                                  CE)




 Report No: (NIE)                                             Page 7 of 16                                               2019-03-28
 02297RCB.004


DEKRA Certification, Inc.
405, Glenn Drive Suite 12
Sterling, Virginia, USA


                                                                                                      CBSD      CBSD
   Test                                                                   Test               SAS                            DP SW
                  Ref            Name           Condition     Date                 Result              SW        HW
   Spec                                                                  sample             version                         Version
                                                                                                      Version   Version

                              Unsuccessful
  WINNF                           Grant
    -TS-      WINNF.FT.C    responseCode=4                               02297.0                      SR16.00
   0122-        .GRA.2             01
                                                 Normal     12/11/2018
                                                                           04
                                                                                   PASS     1.0.0.2               C2         SR16.50
  V1.0.0                        (GRANT
                              CONFLICT)



                             Domain Proxy
  WINNF
                                Heartbeat                                                             SR16.00
    -TS-     WINNF.FT.D                                                  02297.0
   0122-       .HBT.2
                              Success Case       Normal     12/11/2018
                                                                           04
                                                                                   PASS     1.0.0.2               C2         SR16.50
                             (first Heartbeat
  V1.0.0
                                Response)



  WINNF                        Heartbeat
    -TS-      WINNF.FT.C    responseCode=1                               02297.0                      SR16.00
   0122-        .HBT.3            05
                                                 Normal     12/11/2018
                                                                           04
                                                                                   PASS     1.0.0.2               C2         SR16.50
  V1.0.0                    (DEREGISTER)



                               Heartbeat
                            responseCode=5
  WINNF
                                   01                                                                 SR16.00
    -TS-      WINNF.FT.C                                                 02297.0
   0122-        .HBT.5
                            (SUSPENDED_          Normal     12/11/2018
                                                                           04
                                                                                   PASS     1.0.0.2               C2         SR16.50
                            GRANT) in First
  V1.0.0
                               Heartbeat
                                Response



                                Heartbeat
                            responseCode=5
  WINNF                            01
    -TS-      WINNF.FT.C    (SUSPENDED_                                  02297.0                      SR16.00
   0122-        .HBT.6        GRANT) in
                                                 Normal     12/11/2018
                                                                           04
                                                                                   PASS     1.0.0.2               C2         SR16.50
  V1.0.0                       Subsequent
                                Heartbeat
                                Response



  WINNF                        Heartbeat
    -TS-      WINNF.FT.C    responseCode=5                               02297.0                      SR16.00
   0122-        .HBT.7       02 (UNSYNC
                                                 Normal     12/11/2018
                                                                           04
                                                                                   PASS     1.0.0.2               C2         SR16.50
  V1.0.0                      OP PARAM)




                             Domain Proxy
  WINNF                        Heartbeat
    -TS-     WINNF.FT.D     responseCode=5                               02297.0                      SR16.00
   0122-       .HBT.8             00
                                                 Normal     12/11/2018
                                                                           04
                                                                                   PASS     1.0.0.2               C2         SR16.50
  V1.0.0                    (TEMINATED_
                                GRANT)



  WINNF
                                Heartbeat                                                             SR16.00
    -TS-      WINNF.FT.C                                                 02297.0
   0122-        .HBT.9
                            Response Absent      Normal     12/11/2018
                                                                           04
                                                                                   PASS     1.0.0.2               C2         SR16.50
                            (First Heartbeat)
  V1.0.0


  WINNF                        Heartbeat
    -TS-      WINNF.FT.C    Response Absent                              02297.0                      SR16.00
   0122-       .HBT.10        (Subsequent
                                                 Normal     12/11/2018
                                                                           04
                                                                                   PASS     1.0.0.2               C2         SR16.50
  V1.0.0                       Heartbeat)


 Report No: (NIE)                                              Page 8 of 16                                               2019-03-28
 02297RCB.004


DEKRA Certification, Inc.
405, Glenn Drive Suite 12
Sterling, Virginia, USA


                                                                                                     CBSD      CBSD
   Test                                                                  Test               SAS                            DP SW
                  Ref           Name           Condition     Date                 Result              SW        HW
   Spec                                                                 sample             version                         Version
                                                                                                     Version   Version

  WINNF                     Successful Grant
    -TS-      WINNF.FT.C      Renewal in                                02297.0                      SR16.00
   0122-       .HBT.11       Heartbeat Test
                                                Normal     12/11/2018
                                                                          04
                                                                                  PASS     1.0.0.2               C2         SR16.50
  V1.0.0                         Case


                             Domain Proxy
  WINNF                       Registration
    -TS-     WINNF.FT.D        Response                                 02297.0                      SR16.00
   0122-       .MES.2          contains
                                                Normal     12/10/2018
                                                                          04
                                                                                  PASS     1.0.0.2               C2         SR16.50
  V1.0.0                    measReportConfi
                                   g


  WINNF
                            Domain Proxy                                                             SR16.00
    -TS-     WINNF.FT.D                                                 02297.0
   0122-       .RLQ.2
                              Successful        Normal     12/10/2018
                                                                          04
                                                                                  PASS     1.0.0.2               C2         SR16.50
                            Relinquishment
  V1.0.0




                             Domain Proxy
  WINNF
                              Unsuccessful                                                           SR16.00
    -TS-     WINNF.FT.D                                                 02297.0
   0122-       .RLQ.4
                            Relinquishment,     Normal     12/10/2018
                                                                          04
                                                                                  PASS     1.0.0.2               C2         SR16.50
                            responseCode=1
  V1.0.0
                                  02




                             Domain Proxy
  WINNF
                              Unsuccessful                                                           SR16.00
    -TS-     WINNF.FT.D                                                 02297.0
   0122-       .RLQ.6
                            Relinquishment,     Normal     12/10/2018
                                                                          04
                                                                                  PASS     1.0.0.2               C2         SR16.50
                            responseCode=1
  V1.0.0
                                  03




  WINNF
                             Domain Proxy                                                            SR16.00
    -TS-     WINNF.FT.D                                                 02297.0
   0122-       .DRG.2
                              Successful        Normal     12/10/2018
                                                                          04
                                                                                  PASS     1.0.0.2               C2         SR16.50
                             Deregistration
  V1.0.0



  WINNF                      Domain Proxy
    -TS-     WINNF.FT.D      Deregistration                             02297.0                      SR16.00
   0122-       .DRG.4       responseCode=1
                                                Normal     12/10/2018
                                                                          04
                                                                                  PASS     1.0.0.2               C2         SR16.50
  V1.0.0                          02


  WINNF
                             Deregistration                                                          SR16.00
    -TS-      WINNF.FT.C                                                02297.0
   0122-        .DRG.5
                            responseCode=1      Normal     12/11/2018
                                                                          04
                                                                                  PASS     1.0.0.2               C2         SR16.50
                                  03
  V1.0.0


                            Successful TLS
  WINNF
                              connection                                                             SR16.00
    -TS-      WINNF.FT.C                                                02297.0
   0122-        .SCS.1
                             between UUT        Normal     12/12/2018
                                                                          04
                                                                                  PASS     1.0.0.2               C2         SR16.50
                             and SAS Test
  V1.0.0
                                Harness


  WINNF
                            TLS failure due                                                          SR16.00
    -TS-      WINNF.FT.C                                                02297.0
   0122-        .SCS.2
                              to revoked        Normal     12/12/2018
                                                                          04
                                                                                  PASS     1.0.0.2               C2         SR16.50
                              certificate
  V1.0.0


 Report No: (NIE)                                             Page 9 of 16                                               2019-03-28
 02297RCB.004


DEKRA Certification, Inc.
405, Glenn Drive Suite 12
Sterling, Virginia, USA


                                                                                                       CBSD      CBSD
   Test                                                                    Test               SAS                            DP SW
                  Ref            Name            Condition     Date                 Result              SW        HW
   Spec                                                                   sample             version                         Version
                                                                                                       Version   Version

  WINNF
                             TLS failure due                                                           SR16.00
    -TS-      WINNF.FT.C                                                  02297.0
   0122-        .SCS.3
                            to expired server     Normal     12/12/2018
                                                                            04
                                                                                    PASS     1.0.0.2               C2         SR16.50
                                certificate
  V1.0.0



                            TLS failure when
  WINNF                        SAS Test
    -TS-      WINNF.FT.C        Harness                                   02297.0                      SR16.00
   0122-        .SCS.4        certificate is
                                                  Normal     12/12/2018
                                                                            04
                                                                                    PASS     1.0.0.2               C2         SR16.50
  V1.0.0                        issue by
                             unknown CA




                            TLS failure when
  WINNF
                            certificate at the                                                         SR16.00
    -TS-      WINNF.FT.C                                                  02297.0
   0122-        .SCS.5
                               SAS Test           Normal     12/12/2018
                                                                            04
                                                                                    PASS     1.0.0.2               C2         SR16.50
                               Harness is
  V1.0.0
                               corrupted



  WINNF
                               UUT RF                                                                  SR16.00
    -TS-      WINNF.PT.C                                                  02297.0
   0122-         .HBT
                            Transmit Power        Normal     12/12/2018
                                                                            04
                                                                                    PASS     1.0.0.2               C2         SR16.50
                             Measurement
  V1.0.0




 Report No: (NIE)                                               Page 10 of 16                                              2019-03-28
 02297RCB.004


DEKRA Certification, Inc.
405, Glenn Drive Suite 12
Sterling, Virginia, USA




    Appendix B: Test Systems




 Report No: (NIE)           Page 11 of 16   2019-03-28
 02297RCB.004


DEKRA Certification, Inc.
405, Glenn Drive Suite 12
Sterling, Virginia, USA




Test System Used

                                                           Control
    Model                         Description                           Uncertainties
                                                           Number

    Dell
  Latitude,                                                   CTC-
                             Laptop with SAS harness                         NA
 Windows 7,                                                  5233-K
   64-bit

    EXA
                                 Signal Analyzer              0018           NA
   N9010A

    MXA
                                 Signal Analyzer              0382           NA
   N9020A

  HWg-STE
                            Ethernet SNMP Thermometer         1107           NA
   Plain

    DR-
  4X7S201-                      Shielded Chamber              0131           NA
     LH




 Report No: (NIE)                                       Page 12 of 16                   2019-03-28
 02297RCB.004


DEKRA Certification, Inc.
405, Glenn Drive Suite 12
Sterling, Virginia, USA




    Appendix C: CBSD/ DP Supported
    Features




 Report No: (NIE)           Page 13 of 16   2019-03-28
 02297RCB.004


DEKRA Certification, Inc.
405, Glenn Drive Suite 12
Sterling, Virginia, USA




Supported Features

   Condition                                            Feature Description                                          Supported


        C1                        Mandatory for UUT which supports multi-step registration message.                     Y



                        Mandatory for UUT which supports single-step registration with no CPI-signed data in the
        C2             registration message. By definition, this is a subset of Category A devices which determine      N
                                  all registration information, including location, without CPI intervention.


                      Mandatory for UUT which supports single-step registration containing CPI-signed data in the
        C3                                                                                                              Y
                                                       registration message.


                      Mandatory for UUT which supports RECEIVED_POWER_WITHOUT_GRANT measurement
        C4                                                                                                              Y
                                                          report type.


                        Mandatory for UUT which supports RECEIVED_POWER_WITH_GRANT measurement
        C5                                                                                                              N
                                                           report type.

                       Mandatory for UUT which supports parameter change being made at the UUT and prior to
        C6                                                                                                              N
                                                    sending a deregistration.




 Report No: (NIE)                                                  Page 14 of 16                                            2019-03-28
 02297RCB.004


DEKRA Certification, Inc.
405, Glenn Drive Suite 12
Sterling, Virginia, USA




      Appendix D: Reference Standards and
      Procedures




 Report No: (NIE)           Page 15 of 16   2019-03-28
 02297RCB.004


DEKRA Certification, Inc.
405, Glenn Drive Suite 12
Sterling, Virginia, USA




Reference Standards


         Test and Certification for Citizens Broadband Radio Service (CBRS);
         Conformance and Performance Test Technical Specification; CBSD/DP as           V1.0.0
         Unit Under Test (UUT) Working Document WINNF-TS-0122

Test Procedures


        PECB001_00: CBRS Alliance Certification Testing Based On WINN Forum CBRS CBSD
        Test Specification “WINNF-TS-0122”




 Report No: (NIE)                                 Page 16 of 16                                  2019-03-28
 02297RCB.004



Document Created: 2019-04-03 07:00:19
Document Modified: 2019-04-03 07:00:19

© 2024 FCC.report