MPE

FCC ID: PIDAH4200

RF Exposure Info

Download: PDF
FCCID_4239347

Airspan Networks Inc.                                                           FCC ID: PIDAH4200




    Environmental evaluation and exposure limit according to FCC CFR 47part 1,
                             §1.1307, §1.1310



The transceiver is classified as fixed, the calculation was done to check a safe distance.

Limit for power density for general population/uncontrolled exposure is 1 mW/cm2 for 1500 -100000 MHz
frequency range.

The power density P (mW/cm2) = PT / 4 r2, where

PT is the transmitted power, which is equal to the peak transmitter output power
plus maximum antenna gain. The maximum equivalent isotropically radiated power EIRP is

                         PT = 36.9 dBm +9.5 dBi = 46.4 dBm = 43652 mW, where

36.9 dBm is the EUT maximum output power (per port),
9.5 dBi – antenna gain.


The minimum safe distance “r”, where RF exposure does not exceed FCC permissible limit, is

                          r = sqrt { PT / (Px4)} = sqrt {43652 / 12.56} = 59 cm.

A warning about a safe distance is contained in the user manual.




                                                                                             Page 1 of 1



Document Created: 2019-05-01 10:27:07
Document Modified: 2019-05-01 10:27:07

© 2024 FCC.report