Test Report

FCC ID: PH3DJ-175T

Test Report

Download: PDF
FCCID_990323

                            Engineering and Testing for EMC and Safety Compliance



                                       Accredited under A2LA Testing Certificate # 2653.01




                             FCC & IC Certification Report
                                         VHF FM Transceiver
                                           Model: DJ-175T

                                            FCC ID: PH3DJ-175T
                                             IC: 3070C-DJ175T

                                            Alinco Incorporated
                                            Electronics Division
                                            Shin-Dai Building 9F
                                    2-6, 1-Chome, Dojimahama, Kita-ku
                                           Osaka 530-0004 Japan

                                                 August 8, 2008

Standards Referenced for this Report
                                 Frequency Allocations and Radio Treaty Matters; General Rules and
Part 2: 2006
                                 Regulations
                                 Radio Frequency Devices; Scanning Receivers and Frequency Converters
Part 15.121: 2007
                                 Used with Scanning Receivers
                                 Standard Format Measurement/Technical Report Personal Computer and
ANSI C63.4-2007
                                 Peripherals
RSS-215; Issue 1
                                 Analogue Scanner Receivers
(Provisional)

Frequency Range (MHz)              Output Power (W)             Frequency Tolerance           Emission Designators
     136-173.995                         N/A                           N/A                          16K0F3E

                                          REPORT PREPARED BY:

                                     Test Engineer:          Daniel Baltzell
                               Administrative Writer:        Daniel Baltzell

                                        Rhein Tech Laboratories, Inc.

                                         Document Number: 2008118


This report may not be reproduced, except in full, without the full written approval of Rhein Tech Laboratories, Inc.
                          and Alinco Inc. The test results relate only to the item tested.


                                          360 Herndon Parkway, Suite 1400
                                                 Herndon, VA 20170
                                        Tel: 703-689-0368 Fax: 703-689-2056


Rhein Tech Laboratories, Inc.                                                                                                                     Client: Alinco, Inc.
360 Herndon Parkway                                                                                                                                 Model: DJ-175T
Suite 1400                                                                                                                                   Standards: FCC 15.121
Herndon, VA 20170                                                                                                                                      & IC RSS-215
http://www.rheintech.com                                                                                                                           Report: 2008118




                                                                      Table of Contents

1     General Information ........................................................................................................................ 5
    1.1    Modifications.................................................................................................................................................. 5
    1.2    Related Submittal(s)/Grant(s) ........................................................................................................................ 5
    1.3    Test Methodology .......................................................................................................................................... 5
    1.4    Test Facility.................................................................................................................................................... 5
2     System Test Configuration............................................................................................................. 6
    2.1    Justification .................................................................................................................................................... 6
    2.2    Exercising the EUT ........................................................................................................................................ 6
    2.3    Test System Details ....................................................................................................................................... 6
    2.4    Configuration of Tested System..................................................................................................................... 8
3     AC Conducted Emissions - FCC Rules and Regulations Part 15 §15.107(b): Conducted Limits
      .......................................................................................................................................................... 9
    3.1    Site and Test Description............................................................................................................................... 9
    3.2    Test Limits ..................................................................................................................................................... 9
    3.3    Conducted Emissions Test Data.................................................................................................................. 10
4     Radiated Emissions – FCC Rules and Regulations Part 15 §15.109(a): Radiated Emissions
      Limits; RSS-215 Section 7 - Receiver Spurious Emissions ........................................................13
    4.1    Test Methodology for Radiated Emissions Measurements .......................................................................... 13
    4.2    Radiated Emissions Data............................................................................................................................. 14
5     FCC Rules and Regulations Part 15 §15.121(b) - 38 dB Rejection Test .....................................15
    5.1    38 dB Rejection Test Data for Base Band (869.014-893.970 MHz)............................................................. 16
    5.2    38 dB Rejection Test Data for Mobile Band (824.04-848.970 MHz) ............................................................ 16
6     Conclusion......................................................................................................................................17




                                                                                                                                                        Page 2 of 52


Rhein Tech Laboratories, Inc.                                                                                                               Client: Alinco, Inc.
360 Herndon Parkway                                                                                                                           Model: DJ-175T
Suite 1400                                                                                                                             Standards: FCC 15.121
Herndon, VA 20170                                                                                                                                & IC RSS-215
http://www.rheintech.com                                                                                                                     Report: 2008118




                                                                      Table Index

Table 2-1:      Equipment Under Test (EUT)............................................................................................................... 7
Table 3-1:      Conducted Emissions Test Data – Mode RX, Neutral (EDC-165 NiMH Charger) .............................. 10
Table 3-2:      Conducted Emissions Test Data – Mode RX, Phase (EDC-165 NiMH Charger) ............................... 10
Table 3-3:      Conducted Emissions Test Data – Mode RX, Neutral (EDC-164 Li-Ion Charger) .............................. 11
Table 3-4:      Conducted Emissions Test Data – Mode RX, Phase (EDC-164 Li-Ion Charger) ............................... 11
Table 3-5:      Equipment Used for Testing............................................................................................................... 12
Table 4-1:      Radiated Emissions – Mode RX......................................................................................................... 14
Table 4-2:      Equipment Used for Testing............................................................................................................... 14
Table 5-1:      38 dB Rejection {Frequency Injected: 869.04 MHz} (Cellular Band) ................................................. 16
Table 5-2:      38 dB Rejection {Frequency Injected: 881.500 MHz} (Cellular Band) ............................................... 16
Table 5-3:      38 dB Rejection {Frequency Injected: 893.970 MHz} (Cellular Band) ............................................... 16
Table 5-4:      38 dB Rejection {Frequency Injected: 824. 04 MHz} (Mobile Band).................................................. 16
Table 5-5:      38 dB Rejection {Frequency Injected: 836.500 MHz} (Mobile Band)................................................. 16
Table 5-6:      38 dB Rejection {Frequency Injected: 848.970 MHz} (Mobile Band)................................................. 16
Table 5-7:      Equipment Used for Testing............................................................................................................... 17


                                                                   Appendix Index

Appendix A:         Agency Authorization Letter........................................................................................................... 18
Appendix B:         FCC Confidentiality Request Letter ............................................................................................... 19
Appendix C:         FCC Attestation Letter ................................................................................................................... 20
Appendix D:         RSS-215 Attestation Letter ............................................................................................................ 21
Appendix E:         IC Agent Authority and Listing Requirements Letters .................................................................... 22
Appendix F:          IC Confidentiality Request Letter .................................................................................................. 23
Appendix G:         Label & Location............................................................................................................................ 24
Appendix H:         Product Description ....................................................................................................................... 26
Appendix I:         Block Diagram ............................................................................................................................... 27
Appendix J:         Schematics .................................................................................................................................... 28
Appendix K:         Manual........................................................................................................................................... 29
Appendix L:         Test Configuration Photographs .................................................................................................... 30
Appendix M:         External Photographs .................................................................................................................... 35
Appendix N:          Internal Photographs..................................................................................................................... 43




                                                                                                                                                 Page 3 of 52


Rhein Tech Laboratories, Inc.                                                                                                           Client: Alinco, Inc.
360 Herndon Parkway                                                                                                                       Model: DJ-175T
Suite 1400                                                                                                                         Standards: FCC 15.121
Herndon, VA 20170                                                                                                                            & IC RSS-215
http://www.rheintech.com                                                                                                                 Report: 2008118




                                                             Photograph Index

Photograph 1:             FCC/IC ID and Warning Label Locations ............................................................................. 24
Photograph 2:             FCC & IC ID Label Sample .................................................................................................. 25
Photograph 3:             Radiated Emissions Test Configuration (Front View)........................................................... 30
Photograph 4:             Radiated Emissions Test Configuration (Rear View) ........................................................... 31
Photograph 5:             38 dB Rejection Test Configuration ..................................................................................... 32
Photograph 6:             Conducted AC Emissions Test Configuration (Front View).................................................. 33
Photograph 7:             Conducted AC Emissions Test Configuration (Rear View) .................................................. 34
Photograph 8:             Front View............................................................................................................................ 35
Photograph 9:             Back View ............................................................................................................................ 36
Photograph 10:            Right Side View.................................................................................................................... 37
Photograph 11:            Left Side View ...................................................................................................................... 38
Photograph 12:            Top View .............................................................................................................................. 39
Photograph 13:             Bottom View ........................................................................................................................ 40
Photograph 14:            Antenna................................................................................................................................ 41
Photograph 15:            EBP-71 Li-Ion Battery .......................................................................................................... 41
Photograph 16:            EBP-72 Ni-MH Battery ......................................................................................................... 42
Photograph 17:            Inside Back Chassis............................................................................................................. 43
Photograph 18:            Inside Front Cover ............................................................................................................... 44
Photograph 19:            PCB Mounted In Chassis ..................................................................................................... 45
Photograph 20:            Front of PCB with LCD......................................................................................................... 46
Photograph 21:            Front of PCB without LCD.................................................................................................... 47
Photograph 22:            Back of PCB with Shield ...................................................................................................... 48
Photograph 23:            Back of PCB without Shield ................................................................................................. 49




                                                                                                                                             Page 4 of 52


Rhein Tech Laboratories, Inc.                                                               Client: Alinco, Inc.
360 Herndon Parkway                                                                           Model: DJ-175T
Suite 1400                                                                             Standards: FCC 15.121
Herndon, VA 20170                                                                                & IC RSS-215
http://www.rheintech.com                                                                     Report: 2008118




1     General Information

The following application for certification of an analog scanning receiver is prepared on behalf of Alinco
Incorporated; Electronics Division, in accordance with the applicable portions of the FCC Rules and
Regulations Parts 2 and 15 and Industry Canada RSS-215. The Equipment Under Test (EUT) is Model
DJ-175T, FCC ID: PH3DJ-175T, IC: 3070C-DJ175T. The test results reported in this document relate
only to the item that was tested.

All measurements contained in this application were conducted in accordance with ANSI C63.4 Methods
of Measurement of Radio Noise Emissions, 2007. The instrumentation utilized for the measurements
conforms to the ANSI C63.4 standard for EMI and Field Strength Instrumentation. Some accessories are
used to increase sensitivity and prevent overloading of the measuring instrument. Calibration checks are
performed regularly on the instruments, and all accessories including the high pass filter, preamplifier and
cables.

1.1     Modifications

No modifications were made during testing.

1.2     Related Submittal(s)/Grant(s)

This is an original certification submission.

1.3     Test Methodology

Radiated testing was performed according to the procedures in ANSI C63.4-2007. Radiated testing was
performed at an antenna-to-EUT distance of 3 meters.

1.4     Test Facility

The open area test site and conducted measurement facility used to collect the radiated data is located
on the parking lot of Rhein Tech Laboratories, 360 Herndon Parkway, Suite 1400, Herndon, Virginia
20170. This site has been fully described in a report, submitted to, and approved by the Federal
Communications Commission; to perform AC line conducted and radiated emissions testing (ANSI C63.4-
2007).




                                                                                              Page 5 of 52


Rhein Tech Laboratories, Inc.                                                                 Client: Alinco, Inc.
360 Herndon Parkway                                                                             Model: DJ-175T
Suite 1400                                                                               Standards: FCC 15.121
Herndon, VA 20170                                                                                  & IC RSS-215
http://www.rheintech.com                                                                       Report: 2008118




2     System Test Configuration

2.1     Justification

To complete the test configuration required by the FCC, the receiver was connected to an external
antenna, which receives a signal from a signal generator output. With the antenna installed, the receiver
indicator was used to determine optimal reception. The EUT’s intermediate frequencies (IF), local
oscillators (LO), crystal oscillators, and harmonics of each were investigated. Conducted emissions were
measured from the AC port of the charger. All modes were investigated and tested, including standby
mode and scanning mode. The final radiated data was taken with the EUT locked to a set frequency.

2.2     Exercising the EUT

The DJ-175T is a VHF FM transceiver designed to function at the following frequency range:
TX 144-147.995 MHz; RX 136-173.995 MHz. The transmitter portion of the transceiver is subject to the
FCC/IC amateur radio rules and was not tested. The following receiver frequencies were tested: 136,
154.4975, and 173.995 MHz. In order to activate the receiver circuitry, a signal was transmitted from a
signal generator. This allowed the EUT to function in its typical state throughout the course of all testing.

2.3     Test System Details

The test sample was received on August 7, 2008. The FCC Identifiers for all equipment, plus descriptions
of all cables used in the tested system, are shown in the table that follows.




                                                                                                Page 6 of 52


Rhein Tech Laboratories, Inc.                                                 Client: Alinco, Inc.
360 Herndon Parkway                                                             Model: DJ-175T
Suite 1400                                                               Standards: FCC 15.121
Herndon, VA 20170                                                                  & IC RSS-215
http://www.rheintech.com                                                       Report: 2008118




Table 2-1:           Equipment Under Test (EUT)
                                                                                           RTL
                                                   Serial
      Part           Manufacturer     Model                   FCC ID        Cable           Bar
                                                  Number
                                                                                           Code
 FCC VHF FM
                         Alinco      DJ-175T      M000403   PH3DJ-175T       N/A          18568
  Transceiver
7.4V 1200mAh
                         Alinco      EBP-71       004025       N/A           N/A          18522
 Li-Ion Battery
7.4V 1200mAh
                         Alinco      EBP-71         N/A        N/A           N/A          18523
 Li-Ion Battery
7.2V 700mAh
                         Alinco      EBP-72       004011       N/A           N/A          18524
Ni-MH Battery
7.2V 700mAh
                         Alinco      EBP-72       004012       N/A           N/A          18525
Ni-MH Battery
 Li-Ion Battery
                         Alinco      EDC-164      M000401      N/A           N/A          18526
    Charger
Ni-MH Battery
                         Alinco      EDC-165      M000403      N/A           N/A          18531
    Charger
                                                                           1.7m
 EDC-164 AC                          EDC-170
                         Alinco                     N/A        N/A       unshielded       18527
   Adapter                          YSU15120
                                                                           power
                                                                           1.7m
 EDC-165 AC                          EDC-146
                         Alinco                     N/A        N/A       unshielded       18532
   Adapter                          AD35-12002
                                                                           power
    Antenna              Alinco      EA0142         N/A        N/A          N/A           18540
    Antenna              Alinco      EA0142         N/A        N/A          N/A           18541
    Antenna              Alinco      EA0142         N/A        N/A          N/A           18542
    Antenna              Alinco      EA0142         N/A        N/A          N/A           18543




                                                                                Page 7 of 52


Rhein Tech Laboratories, Inc.                              Client: Alinco, Inc.
360 Herndon Parkway                                          Model: DJ-175T
Suite 1400                                            Standards: FCC 15.121
Herndon, VA 20170                                               & IC RSS-215
http://www.rheintech.com                                    Report: 2008118




2.4    Configuration of Tested System




                            Antenna input




                                             EUT
                                            DJ-175T




                                                             Page 8 of 52


Rhein Tech Laboratories, Inc.                                                           Client: Alinco, Inc.
360 Herndon Parkway                                                                       Model: DJ-175T
Suite 1400                                                                         Standards: FCC 15.121
Herndon, VA 20170                                                                            & IC RSS-215
http://www.rheintech.com                                                                 Report: 2008118




3     AC Conducted Emissions - FCC Rules and Regulations Part 15 §15.107(b): Conducted Limits

3.1     Site and Test Description

The power line conducted emissions measurements were performed in a Series 81 type shielded enclosure
manufactured by Rayproof. The EUT was assembled on a wooden table 80 centimeters high. Power was
fed to the EUT through a 50-ohm/50 microhenry Line Impedance Stabilization Network (LISN). The EUT
LISN was fed power through an A.C. filter box on the outside of the shielded enclosure. The filter box and
EUT LISN housing are bonded to the ground plane of the shielded enclosure. A second LISN, the peripheral
LISN, provides isolation for the EUT test peripherals. This peripheral LISN was also fed A.C. power. A
metal power outlet box, which is bonded to the ground plane and electrically connected to the peripheral
LISN, powers the EUT host peripherals.

The spectrum analyzer was connected to the A.C. line through an isolation transformer. The 50-ohm output
of the EUT LISN was connected to the spectrum analyzer input through a Solar 100 kHz high-pass filter. The
filter is used to prevent overload of the spectrum analyzer from noise below 100 kHz. Conducted emission
levels were measured on each current-carrying line with the spectrum analyzer operating in the CISPR
quasi-peak mode (or peak mode if applicable).

The analyzer's 6 dB bandwidth was set to 9 kHz. A video filter less than 10 times the resolution bandwidth is
not used. Average measurements are performed in linear mode using a 10 kHz resolution bandwidth, a 1 Hz
video bandwidth, and by increasing the sweep time in order to obtain a calibrated measurement. The emission
spectrum was scanned from 150 kHz to 30 MHz. The highest emission amplitudes relative to the appropriate
limits were measured and have been recorded.

3.2     Test Limits

                                    Class A Line Conducted Emissions
                                                             Limit (dBµV)
         Frequency (MHz)                       Quasi-Peak                          Average
            0.15 to 0.50                           79                                66
            0.50 to 30.0                           73                                60

                                    Class B Line Conducted Emissions
                                                             Limit (dBµV)
         Frequency (MHz)                       Quasi-Peak                          Average
            0.15 to 0.50                         66 to 56                          56 to 46
            0.50 to 5.00                           56                                46
           5.00 to 30.00                           60                                50




                                                                                          Page 9 of 52


Rhein Tech Laboratories, Inc.                                                               Client: Alinco, Inc.
360 Herndon Parkway                                                                           Model: DJ-175T
Suite 1400                                                                             Standards: FCC 15.121
Herndon, VA 20170                                                                                & IC RSS-215
http://www.rheintech.com                                                                     Report: 2008118




3.3    Conducted Emissions Test Data

Table 3-1:           Conducted Emissions Test Data – Mode RX, Neutral (EDC-165 NiMH Charger)
                                         Temperature: 76.7°F Humidity: 27%
                                             Site              FCC B      FCC B    FCC B    FCC B
Emission                        Analyzer              Emission
                  Test                    Correction             QP        QP        AV       AV         Pass/
Frequency                       Reading                 Level
                Detector                   Factor               Limit    Margin     Limit   Margin        Fail
  (MHz)                          (dBuV)                (dBuV)
                                             (dB)              (dBuV)    (dBuV)    (dBuV)   (dBuV)
   0.159           Pk            41.2        0.2       41.4      65.5    -24.1      55.5     -14.1       Pass
   0.310           Pk            37.9        0.2       38.1      60.0    -21.9      50.0     -11.9       Pass
   0.498           Pk            37.1        0.2       37.3      56.0    -18.7      46.0      -8.7       Pass
   0.560           Pk            35.9        0.2       36.1      56.0    -19.9      46.0      -9.9       Pass
   7.760           Pk            18.1        1.6       19.7      60.0    -40.3      50.0     -30.3       Pass
  18.970           Pk            17.8        2.5       20.3      60.0    -39.7      50.0     -29.7       Pass

Table 3-2:           Conducted Emissions Test Data – Mode RX, Phase (EDC-165 NiMH Charger)
                                         Temperature: 76.7°F Humidity: 27%
                                              Site              FCC B      FCC B   FCC B      FCC B
Emission                        Analyzer               Emission
                  Test                     Correction             QP        QP       AV         AV        Pass/
Frequency                       Reading                   Level
                Detector                    Factor               Limit    Margin    Limit     Margin       Fail
  (MHz)                          (dBuV)                  (dBuV)
                                              (dB)              (dBuV) (dBuV)      (dBuV)     (dBuV)
   0.162            Pk            40.7        0.2       40.9      65.4    -24.5     55.4       -14.5      Pass
   0.322            Pk            37.7        0.2       37.9      59.7    -21.8     49.7       -11.8      Pass
   0.496            Pk            36.3        0.2       36.5      56.1    -19.6     46.1        -9.6      Pass
   0.740            Pk            26.9        0.3       27.2      56.0    -28.8     46.0       -18.8      Pass
  13.480            Pk            17.0        2.2       19.2      60.0    -40.8     50.0       -30.8      Pass
  28.850            Pk            17.5        2.8       20.3      60.0    -39.7     50.0       -29.7      Pass




                                                                                              Page 10 of 52


Rhein Tech Laboratories, Inc.                                                               Client: Alinco, Inc.
360 Herndon Parkway                                                                           Model: DJ-175T
Suite 1400                                                                             Standards: FCC 15.121
Herndon, VA 20170                                                                                & IC RSS-215
http://www.rheintech.com                                                                     Report: 2008118




Table 3-3:           Conducted Emissions Test Data – Mode RX, Neutral (EDC-164 Li-Ion Charger)
                                         Temperature: 76.7°F Humidity: 27%
                                             Site              FCC B      FCC B    FCC B    FCC B
Emission                        Analyzer              Emission
                  Test                    Correction             QP        QP        AV       AV         Pass/
Frequency                       Reading                 Level
                Detector                   Factor               Limit    Margin     Limit   Margin        Fail
  (MHz)                          (dBuV)                (dBuV)
                                             (dB)              (dBuV)    (dBuV)    (dBuV)   (dBuV)
   0.179           Av            25.5        0.2       25.7      64.5    -38.8      54.5     -28.8       Pass
   0.179           Qp            50.8        0.2       51.0      64.5    -13.5      54.5      -3.5       Pass
   0.270           Av            18.6        0.2       18.8      61.1    -42.3      51.1     -32.3       Pass
   0.270           Qp            39.6        0.2       39.8      61.1    -21.3      51.1     -11.3       Pass
   0.361           Av            16.4        0.2       16.6      58.7    -42.1      48.7     -32.1       Pass
   0.361           Qp            35.3        0.2       35.5      58.7    -23.2      48.7     -13.2       Pass
   1.541           Av            14.5        0.8       15.3      56.0    -40.7      46.0     -30.7       Pass
   1.541           Qp            35.4        0.8       36.2      56.0    -19.8      46.0      -9.8       Pass
   2.670           Av            16.5        1.1       17.6      56.0    -38.4      46.0     -28.4       Pass
   2.670           Qp            37.4        1.1       38.5      56.0    -17.5      46.0      -7.5       Pass
  10.960           Pk            27.6        1.8       29.4      60.0    -30.6      50.0     -20.6       Pass

Table 3-4:           Conducted Emissions Test Data – Mode RX, Phase (EDC-164 Li-Ion Charger)
                                         Temperature: 76.7°F Humidity: 27%
                                              Site              FCC B      FCC B   FCC B      FCC B
Emission                        Analyzer               Emission
                  Test                     Correction             QP        QP       AV         AV        Pass/
Frequency                       Reading                   Level
                Detector                    Factor               Limit    Margin    Limit     Margin       Fail
  (MHz)                          (dBuV)                  (dBuV)
                                              (dB)              (dBuV) (dBuV)      (dBuV)     (dBuV)
   0.183            Av            20.1        0.2       20.3      64.3    -44.0     54.3       -34.0      Pass
   0.183            Qp            49.0        0.2       49.2      64.3    -15.1     54.3        -5.1      Pass
   0.275            Av            16.2        0.2       16.4      61.0    -44.6     51.0       -34.6      Pass
   0.275            Qp            37.5        0.2       37.7      61.0    -23.3     51.0       -13.3      Pass
   0.370            Av            17.0        0.2       17.2      58.5    -41.3     48.5       -31.3      Pass
   0.370            Qp            35.7        0.2       35.9      58.5    -22.6     48.5       -12.6      Pass
   1.097            Av            14.0        0.6       14.6      56.0    -41.4     46.0       -31.4      Pass
   1.097            Qp            33.0        0.6       33.6      56.0    -22.4     46.0       -12.4      Pass
   2.462            Av            17.0        1.1       18.1      56.0    -37.9     46.0       -27.9      Pass
   2.462            Qp            37.6        1.1       38.7      56.0    -17.3     46.0        -7.3      Pass
  11.680            Pk            27.4        2.0       29.4      60.0    -30.6     50.0       -20.6      Pass




                                                                                              Page 11 of 52


Rhein Tech Laboratories, Inc.                                                        Client: Alinco, Inc.
360 Herndon Parkway                                                                    Model: DJ-175T
Suite 1400                                                                      Standards: FCC 15.121
Herndon, VA 20170                                                                         & IC RSS-215
http://www.rheintech.com                                                              Report: 2008118




Table 3-5:           Equipment Used for Testing
  RTL                                                                                       Calibration
                  Manufacturer      Model                Part Type       Serial Number
 Asset #                                                                                       Date
 900896        Hewlett Packard     85662A            Display Section     2816A16471            4/2/09
                                                  HP Spectrum Analyzer
 900897        Hewlett Packard      8567A                                2727A00535            4/2/09
                                                    (10KHz-1.5GHz)
                                                   Quasi-Peak Adapter
 900901        Hewlett Packard     85650A                                3145A01599            4/2/09
                                                     (30 Hz-1 GHz)
 901082        AFJ International    LS16                16A LISN         16010020081           4/2/09


Test Personnel:



         Daniel W. Baltzell                                                 August 8, 2008
          Test Engineer                           Signature                  Date Of Test




                                                                                         Page 12 of 52


Rhein Tech Laboratories, Inc.                                                                     Client: Alinco, Inc.
360 Herndon Parkway                                                                                 Model: DJ-175T
Suite 1400                                                                                   Standards: FCC 15.121
Herndon, VA 20170                                                                                      & IC RSS-215
http://www.rheintech.com                                                                           Report: 2008118




4     Radiated Emissions – FCC Rules and Regulations Part 15 §15.109(a): Radiated Emissions Limits;
      RSS-215 Section 7 - Receiver Spurious Emissions

4.1     Test Methodology for Radiated Emissions Measurements

 Before final measurements of radiated emissions were made on the open-field three/ten meter range, the
 EUT was scanned indoors at one meter and three meter distances, in order to determine its emissions
 spectrum signature. The physical arrangement of the test system and associated cabling was varied in
 order to determine the effect on the EUT's emissions in amplitude, direction, and frequency. This process
 was repeated during final radiated emissions measurements on the open-field range, at each frequency, in
 order to ensure that maximum emission amplitudes were attained.

 Final radiated emissions measurements were made on the three meter, open-field test site. The EUT was
 placed on a nonconductive turntable approximately 80 centimeters above the ground plane. The spectrum
 was examined from 30 MHz to 1000 MHz using a spectrum analyzer, a quasi-peak adapter, and EMCO log
 periodic and biconical antenna. In order to gain sensitivity, a preamplifier was connected in series between
 the antenna and the input of the spectrum analyzer.

 At each frequency, the EUT was rotated 360 degrees, and the antenna was raised and lowered from one to
 four meters in order to determine the maximum emission levels. Measurements were taken using both
 horizontal and vertical antenna polarizations. The spectrum analyzer's 6 dB bandwidth was set to 120 kHz,
 and the analyzer was operated in the CISPR quasi-peak detection mode. No video filter less than 10 times
 the resolution bandwidth was used. The second harmonic of the highest LO was tested. The highest
 emission amplitudes relative to the appropriate limit were measured and recorded in this report.

 Note: Rhein Tech Laboratories, Inc. has implemented procedures to minimize errors that occur from test instruments,
 calibration, procedures, and test setups. Test instrument and calibration errors are documented from the manufacturer
 or calibration lab. Rhein Tech implements the following procedures to minimize errors that may occur: yearly as well
 as daily calibration methods, technician training, and emphasis to employees on avoiding error.




                                                                                                    Page 13 of 52


 Rhein Tech Laboratories, Inc.                                                                       Client: Alinco, Inc.
 360 Herndon Parkway                                                                                   Model: DJ-175T
 Suite 1400                                                                                     Standards: FCC 15.121
 Herndon, VA 20170                                                                                        & IC RSS-215
 http://www.rheintech.com                                                                             Report: 2008118




 4.2    Radiated Emissions Data

 Table 4-1:           Radiated Emissions – Mode RX
                                         Temperature: 78°F       Humidity: 38%
                                                                              Site
 Emission                  Antenna    Turntable   Antenna      Analyzer                Emission
                Test                                                      Correction                   Limit        Margin
Frequency                  Polarity    Azimuth     Height      Reading                   Level
              Detector                                                      Factor                   (dBuV/m)        (dB)
  (MHz)                     (H/V)       (deg)       (m)         (dBuV)                 (dBuV/m)
                                                                            (dB/m)
 48.226          Qp              H       0           1.0         34.8          -14.5     20.3           40.0         -19.7

130.200          Qp              V       0           1.0         33.9          -13.4     20.5           43.5         -23.0

144.671          Qp              H       0           1.0         33.3          -14.1     19.2           43.5         -24.3

148.300          Qp              V      180          1.0         32.3          -14.4     17.9           43.5         -25.6

246.600          Qp              H       0           1.0         31.1          -12.5     18.6           46.0         -27.4

313.456          Qp              V       0           1.0         31.1          -10.4     20.7           46.0         -25.3
 Notes: A low, middle, and high channel was checked for the receive band
 Limit/Distance: FCC B/3M


 Table 4-2:           Equipment Used for Testing
    RTL                                                                                    Serial            Calibration
                       Manufacturer          Model                 Part Type
   Asset #                                                                                Number                Date
                       Rhein Tech                          OATS 1 Preamplifier 40 dB
   900905                                 PR-1036                                          1006                 6/2/09
                       Laboratories                            (30 MHz–2 GHz)
                                                              Spectrum Analyzer
   900913           Hewlett Packard          8546A                                      3325A00159             4/15/09
                                                               (9 kHz-6.5 GHz)
                                                                Bi-Log Antenna
   901053           Schaffner Chase      CBL6112B                                          2648                12/20/08
                                                               (20 MHz-2 GHz)


 Test Personnel:



          Daniel W. Baltzell                                                              August 8, 2008
           Test Engineer                              Signature                            Date Of Test




                                                                                                       Page 14 of 52


Rhein Tech Laboratories, Inc.                                                               Client: Alinco, Inc.
360 Herndon Parkway                                                                           Model: DJ-175T
Suite 1400                                                                             Standards: FCC 15.121
Herndon, VA 20170                                                                                & IC RSS-215
http://www.rheintech.com                                                                     Report: 2008118




5   FCC Rules and Regulations Part 15 §15.121(b) - 38 dB Rejection Test

A signal generator was connected to the receiver under test, and the output of the receiver was connected to
an audio analyzer.

An FM signal was applied to the receiver antenna input with a 1 kHz tone modulated at 5 kHz deviation,
and adjusted with the audio analyzer to produce a 12 dB SINAD. This was done across the receiver
bands to determine a reference level. The reference level used was that with the highest sensitivity in all
of the bands.

The output of the signal generator was then adjusted to a level 136 dB above the reference level established,
and set to a low, medium, and high frequency in both the mobile and base cellular bands: the mobile band
being 824.04 MHz-848.97 MHz, and the base band being 869.04 MHz-893. 97 MHz. The squelch of the
receiver was then set to a minimum threshold level, and scanning begun from the lowest to the highest
channel. Whenever the receiver stopped and “un-squelched”, that frequency was noted as a response. After
all the frequencies of responses were noted, the signal generator was set to measure the sensitivity at each
of these response frequencies. This measurement was the reference sensitivity for the particular received
frequency measured. The audio analyzer measurement was used to measure the 12 dB SINAD, which is the
spurious value. The difference between the reference sensitivity and the spurious value is the rejection ratio
and must be at least 38 dB.


                  HP 8648C Signal
                      Generator           Antenna           Audio          HP 8903B Audio Analyzer
                     (1 kHz tone/         input             output
                 8 kHz FM deviation)




                                                      EUT




Frequencies used on the signal generator were 824.04, 836.50, and 848.97 MHz for the mobile band,
and 869.04, 881.50, and 893.97 MHz for the base band.

The DJ-175T unit reference level used was –79 dBm from the signal generator. The DJ-175T unit was
scanned on all specified operating frequency ranges, per manufacturer’s specifications. Signals that
were noted as responses were checked with the signal generator off. If they were still present, they were
determined to be ambient signals and removed from the response list.

No signals were detected for the 38 dB rejection test requirements.




                                                                                              Page 15 of 52


Rhein Tech Laboratories, Inc.                                                              Client: Alinco, Inc.
360 Herndon Parkway                                                                          Model: DJ-175T
Suite 1400                                                                            Standards: FCC 15.121
Herndon, VA 20170                                                                               & IC RSS-215
http://www.rheintech.com                                                                    Report: 2008118




5.1    38 dB Rejection Test Data for Base Band (869.014-893.970 MHz)

Table 5-1:           38 dB Rejection {Frequency Injected: 869.04 MHz} (Cellular Band)
       Frequency Injected: 869.04 MHz                       Temperature: 74°F; Humidity: 38%
    Frequency             Level 12 dB                 Level 12 dB at
                                                                              Rejection             Margin
  Detected (MHz)    SINAD at 869.04 MHz            Frequency Detected
  No Frequencies
                                 N/A                      N/A                   N/A                   N/A
     Detected

Table 5-2:           38 dB Rejection {Frequency Injected: 881.500 MHz} (Cellular Band)
      Frequency Injected: 881.500 MHz                       Temperature: 74°F; Humidity: 38%
    Frequency             Level 12 dB                 Level 12 dB at
                                                                              Rejection             Margin
  Detected (MHz)     SINAD at 881.500 MHz          Frequency Detected
  No Frequencies
                                 N/A                      N/A                   N/A                   N/A
     Detected

Table 5-3:           38 dB Rejection {Frequency Injected: 893.970 MHz} (Cellular Band)
      Frequency Injected: 893.970 MHz                       Temperature: 74°F; Humidity: 38%
    Frequency             Level 12 dB                 Level 12 dB at
                                                                              Rejection             Margin
  Detected (MHz)     SINAD at 893.970 MHz          Frequency Detected
  No Frequencies
                                 N/A                      N/A                   N/A                   N/A
     Detected

5.2    38 dB Rejection Test Data for Mobile Band (824.04-848.970 MHz)

Table 5-4:           38 dB Rejection {Frequency Injected: 824. 04 MHz} (Mobile Band)
      Frequency Injected: 824.04 MHz                       Temperature: 74°F; Humidity: 38%
    Frequency            Level 12 dB                 Level 12 dB at
                                                                              Rejection             Margin
  Detected (MHz)    SINAD at 824.0136 MHz         Frequency Detected
  No Frequencies
                                N/A                      N/A                    N/A                   N/A
     Detected

Table 5-5:           38 dB Rejection {Frequency Injected: 836.500 MHz} (Mobile Band)
     Frequency Injected: 836.500 MHz                       Temperature: 74°F; Humidity: 38%
    Frequency            Level 12 dB                 Level 12 dB at
                                                                              Rejection             Margin
  Detected (MHz)    SINAD at 836.500 MHz          Frequency Detected
  No Frequencies
                                N/A                      N/A                    N/A                   N/A
     Detected

Table 5-6:           38 dB Rejection {Frequency Injected: 848.970 MHz} (Mobile Band)
     Frequency Injected: 848.970 MHz                       Temperature: 74°F; Humidity: 38%
    Frequency            Level 12 dB                 Level 12 dB at
                                                                              Rejection             Margin
  Detected (MHz)    SINAD at 848.970 MHz          Frequency Detected
  No Frequencies
                                N/A                      N/A                    N/A                   N/A
     Detected




                                                                                             Page 16 of 52


Rhein Tech Laboratories, Inc.                                                         Client: Alinco, Inc.
360 Herndon Parkway                                                                     Model: DJ-175T
Suite 1400                                                                       Standards: FCC 15.121
Herndon, VA 20170                                                                          & IC RSS-215
http://www.rheintech.com                                                               Report: 2008118




Table 5-7:           Equipment Used for Testing
     RTL                                                                      Serial        Calibration
                  Manufacturer      Model                Part Type
    Asset #                                                                  Number            Date
                                                     Signal Generator,
 900917         Hewlett Packard     8648C                                 3537A01741           9/5/08
                                                     100 kHz-3.2 GHz
 901067         Hewlett Packard    HP8903B            Audio Analyzer      2450A00135         10/17/08


Test Personnel:



          Daniel W. Baltzell                                                  August 7, 2008
           Test Engineer                          Signature                    Date Of Test




6     Conclusion

The data in this measurement report shows that the Alinco Incorporated Model DJ-175T, FCC ID:
PH3DJ-175T, IC: 3070C-DJ175T, complies with all applicable requirements of Parts 2 and 15.121 of the
FCC Rules and Industry Canada RSS-215, Issue 1.




                                                                                        Page 17 of 52



Document Created: 2008-08-25 11:56:40
Document Modified: 2008-08-25 11:56:40

© 2025 FCC.report