RF Exposure SAR Report 3

FCC ID: PD9AX200D2L

RF Exposure Info

Download: PDF
FCCID_4251325

                                                                           Report Number: SAR.20190415



Appendix F – Phantom Calibration Data Sheets




© 2019 RF Exposure Lab, LLC                                                                     Page 241 of 243
This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.


Schmid & Partner Engineering AG
                                                                                    e        _2
Zeughausstrasse 43, 8004 Zurich, Switzerland
Phone +41 44 245 9700, Fax +41 44 245 9779
info@speag.com, http. //www.speag.com




Certificate of Conformity / First Article Inspection
 Item                             Oval Flat Phantom ELI 4.0
 Type No                          QD OVA 001 B
 Series No                        1003 and higher
 Manufacturer                     Untersee Composites
                                  Knebelstrasse 8
                                  CH—8268 Mannenbach, Switzerland

Tests
Complete tests were made on the prototype units QD OVA 001 AA 1001, QD OVA 001 AB 1002,
pre—series units QD OVA 001 BA 1003—1005 as weil as on the series units QD OVA 001 BB, 1006 ff.

 Test            Requirement                               Details                                Units tested
 Material        Compliant with the standard               Bottom plate:                          all
 thickness       requirements                              2.0mm +/— 0.2mm
 Material        Dielectric parameters for required        < 6 GHz: Rel. permittivity = 4         Material
 parameters      frequencies                               +/—1, Loss tangent < 0.05              sample
 Material        The material has been tested to be        DGBE based simulating                  Equivalent
 resistivity     compatible with the liquids defined in    liquids.                               phantoms,
                 the standards if handled and cleaned      Observe Technical Note for             Material
                 according to the instructions.            material compatibility.                sample
 Shape           Thickness of botom material,              Bottom elliptical 600 x 400 mm         Prototypes,
                 Internal dimensions,                      Depth 190 mm,                          Sample
                 Sagging                                   Shape is within tolerance for          testing
                 compatible with standards from            filling height up to 155 mm,
                 minimum frequency                         Eventual sagging is reduced or
                                                           eliminated by support via DUT

Standards
[1]    CENELEC EN 50361—2001, « Basic standard for the measurement of the Specific Absorption Rate
       related to human exposure to electromagnetic fields from mobile phones (300 MHz — 3 GHz) », July
       2001
[2]    IEEE 1528—2003, "Recommended Practice for Determining the Peak Spatial—Average Specific
       Absorption Rate (SAR) in the Human Head from Wireless Communications Devices: Measurement
       Techniques, December 2003
[3]    IEC 62209 — 1, "Specific Absorption Rate (SAR) in the frequency range of 300 MHz to 3 GHz —
       Measurement Procedure, Part 1: Hand—held mobile wireless communication devices", February
       2005
[4]    IEC 62209 —— 2, Draft, "Human Exposure to Radio Frequency Fields from Handheld and Body—
       Mounted Wireless Communication Devices — Human models, Instrumentation and Procedures —
       Part 2: Procedure to determing the Specific Absorption Rate (SAR) in the head and body for 30
       MHz to 6 GHz Handheld and Body—Mounted Devices used in close proximity to the Body.",
       February 2005
[8]    OET Bulletin 65, Supplement C, "Evaluating Compliance with FCC Guidelines for Human Exposure
       to Radiofrequency Electromagnetic Fields", Edition January 2001

Based on the tests above, we certify that this item is in compliance with the standards [1] to [5] if
operated according to the specific requirements and considering the thickness. The dimensions are fully
compliant with [4] from 30 MHz to 6 GHz. For the other standards, the minimum lower frequency limit is
limited due to the dimensional requirements ([1]: 450 MHz, [2]: 300 MHz, [3]: 800 MHz, [5]:; 375 MHz)
and possibly further by the dimensions of the DUT.        § P 8 @
                                                          Schmid&&Partner Engineering AG
Date           28.4.2008           Signature / Stamp      Zeughaugétrasse 43,8004 Zurich, Switzectand
                                                          Phone 441 44 245 9700, Fax +41,44,245 9779
                                                          info@gbeag.com; hitp//wwww.speag.com

Doc No   881 —QD OVA 001 B— D                                                                     Page         1 (1)


                                                                              Report Number: SAR.20190415


  Appendix G – Validation Summary

  Per FCC KDB 865664 D02 v01r02, SAR system validation status should be documented to
  confirm measurement accuracy. The SAR systems (including SAR probes, system components
  and software versions) used for this device were validated against its performance
  specifications prior to the SAR measurements. Reference dipoles were used with the required
  tissue equivalent media for system validation according to the procedures outlined in FCC KDB
  865664 D01 v01r04 and IEEE 1528-2013. Since SAR probe calibrations are frequency
  dependent, each probe calibration point was validated at a frequency within the valid frequency
  range of the probe calibration point using the system that normally operates with the probe for
  routine SAR measurements and according to the required tissue equivalent media.

  A tabulated summary of the system validation status including the validation date(s),
  measurement frequencies, SAR probes and tissue dielectric parameters has been included.

                                                    Table G-1
                                          SAR System Validation Summary
 SAR                                                                                    CW Validation             Modulation Validation
          Freq.               Probe   Probe     Probe Cal.    Cond.   Perm.
System              Date                                                      Sens-        Probe       Probe    Modulation    Duty
         (MHz)                 S/N    Type        Point        (σ)     (ɛr)                                                           PAR
   #                                                                          itivity    Linearity   Isotropy     Type       Factor



  2      2450     5/03/2018   3693    EX3DV4   2450   Body    1.98    52.59    Pass        Pass         Pass    OFDM/TDD     Pass     Pass

  2      5250     5/02/2018   3693    EX3DV4   5200   Body    5.33    48.88    Pass        Pass         Pass      OFDM        N/A     Pass
  2      5600     5/02/2018   3693    EX3DV4   5600   Body    5.75    48.31    Pass        Pass         Pass      OFDM        N/A     Pass
  2      5750     5/02/2018   3693    EX3DV4   5800   Body    5.96    48.16    Pass        Pass         Pass      OFDM        N/A     Pass
  3      2450     1/28/2019   3833    EX3DV4   2450   Body    1.97    52.53    Pass        Pass         Pass    OFDM/TDD     Pass     Pass
  3      5250     1/28/2019   3833    EX3DV4   5200   Body    5.30    48.93    Pass        Pass         Pass      OFDM        N/A     Pass
  3      5600     1/29/2019   3833    EX3DV4   5600   Body    5.79    48.33    Pass        Pass         Pass      OFDM        N/A     Pass
  3      5750     1/29/2019   3833    EX3DV4   5800   Body    5.97    48.13    Pass        Pass         Pass      OFDM        N/A     Pass
  3      2450     4/12/2019   7530    EX3DV4   2450   Body    1.96    52.64    Pass        Pass         Pass    OFDM/TDD     Pass     Pass
  3      5250     4/11/2019   7530    EX3DV4   5200   Body    5.40    48.88    Pass        Pass         Pass      OFDM        N/A     Pass
  3      5600     4/11/2019   7530    EX3DV4   5600   Body    5.80    48.36    Pass        Pass         Pass      OFDM        N/A     Pass
  3      5750     4/11/2019   7530    EX3DV4   5800   Body    5.99    48.14    Pass        Pass         Pass      OFDM        N/A     Pass




  © 2019 RF Exposure Lab, LLC                                                                           Page 243 of 243
  This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.



Document Created: 2019-04-25 17:53:59
Document Modified: 2019-04-25 17:53:59

© 2025 FCC.report
This site is not affiliated with or endorsed by the FCC