Test Report JBP Revised

FCC ID: PD99260D2L

Test Report

Download: PDF
FCCID_4169676

                                   EMC Testreport
                              FCC 47 CFR PART 15 B (US)
 Produkte
 Products                      INCL. ICES-003 (Canada)
 Prüfbericht-Nr.:                                                                  Auftrags-Nr.:                                             Seite 1 von 29
                                      18121105.f01                                                            3001653257
 Test Report No.:                                                                  Order No.:                                                 Page 1 of 29
 Kunden-Referenz-Nr.:                                                              Auftragsdatum:
                                      4602437                                                                 December 13, 2018
 Client Reference No.:                                                             Order date:

 Auftraggeber:                        Intel Corporation SAS, Le Cargo B6 / 424 Rue de Goa, 06600 Antibes, France
 Client:

 Prüfgegenstand:
                                      Wireless Network Card
 Test item:
 Bezeichnung / Typ-Nr.:
                                      9260D2WL
 Identification / Type No.:
 Auftrags-Inhalt:
                                      Compliance with EMC Standards
 Order content:

 Prüfgrundlage:
 Test specification:                  47 CFR PART 15 (10-1-17 EDITION), Subpart 15B
                                      ICES-003 (Issue 6, January 2016)


Wareneingangsdatum:
                                      Dec. 18, 2018
Date of receipt:
Prüfmuster-Nr.:                       Engineering Sample
Test sample No.:
Prüfzeitraum:                         Jan 30, 2019 – Feb 6, 2019
Testing period:
Ort der Prüfung:
                                      Leek
Place of testing:
Prüflaboratorium:                     TÜV Rheinland Nederland
Testing laboratory:                   B.V. Leek Laboratory
Prüfergebnis*:
                                      Pass
Test result*:

Geprüft von / tested by:                                                           Kontrolliert von / reviewed by:


Feb 8, 2019        W. Brouwer Test Engineer EMC                                   Date             K.F. van der Molen, Senior expert EMC
Datum               Name / Stellung           Unterschrift                             Datum               Name / Stellung                   Unterschrift
Date                Name / Position           Signature                                Date                Name / Position                   Signature

Sonstiges / Other:                None




Zustand des Prüfgegenstandes be Anlieferung: 2                                         Prüfmuster vollständig und unbeschädigt
Condition of the test item at delivery: 2                                              Test item complete and undamaged
* Legende:     1 = sehr gut             2 = gut                3 = befriedigend                                4 = ausreichend         5 = mangelhaft
               P(ass) = entspricht o.g. Prüfgrundlage(n)       F(ail) = entspricht nicht o.g. Prüfgrundlage(n) N/A = nicht anwendbar   N/T/ = nicht getested

 Legend:       1 = very good           2 = good                3 = satisfactory                              4 = sufficient            5 = poor
               P(ass) = passed a.m.    Test specification(s)   F(ail) a.m. test specification(s)             N/A = not applicable      N/T = not tested

       Dieser Prüfbericht bezieht sich nur auf das o.g. Prüfmuster und darf ohne Genehmigung der Prüfstelle nicht
          auszugsweise vervielfältigt werden. Dieser Bericht berechtigt nicht zur Verwending eines Prüfzeichens.
   This test report only relates to the a.m. testsample. Without permission of the test center this test report is not permitted to be
 V04                           duplicated in extracts. This report does not entitle to carry any test mark


                      TÜV Rheinland Nederland B.V. . Eiberkamp 10 . 9351 VT Leek . Tel: + 31 88 8887888
                                         Mail: info@nl.tuv.com . Web: www.tuv.com


Produkte
Products


 Prufbericht-Nr: 18121105.f01                                                                      Seite 2 von 29
 Test report No: 18121105.f01                                                                       Page 2 of 29



                                      Liste der verwendenten Prüfmittel
                                         List of used test equipment

 Prüfmittel Nr. / ID-Nr.                             Prüfmittel                             Nächste Kalibrierung
 Equipment No. / ID-No.                            Test equipment                              Next calibration


                                          Verified List September, 2018
                                               Conducted emission
 A00726                    Rohde &      ESCS30            Measurement Receiver              1-11-2019
                           Schwarz
 A01978                    Rohde &      ESH3-Z2           Impulse Limiter                   27-6-2019
                           Schwarz
 A00051                    Rohde &      ESH3-Z2           Impulse Limiter                   16-11-2019
                           Schwarz
 A01980                    Rohde &      ESCS 30           Test Receiver                     28-6-2019
                           Schwarz
 A00022                    Emco         3725/2            LISN FCC 50 uH / 50 ohm           29-1-2020
 A00354                    Rohde &      ESH2-Z5           LISN- artificial Network          27-6-2019
                           Schwarz
 A00093                    COMTES       1415               Conducted Reference              4-6-2019
                           T                               Source 9kHz-50MHz
                                                 Radiated emission
 A00314                    Rohde &      ESCI              Measurement Receiver              13-4-2019
                           Schwarz                        (9kHz-3GHz)
 A00337                    R&S          FSV30             Signal Analyzer/Spectrum          21-6-2019
                                                          Analyzer
 A00077                    Chase        CBL6111B          Biconilog                         1-12-2019
 A00235                    Siepel       FCC               FCC Test Site Registration nr     15-3-2020
                                                          786213
 A00313                    Comtest                        Site registration filing Indus-   20-11-2020
                                                          try Canada
 A00436                    Siepel                         S-AR                              28-9-2020
 A00447                    Gigalink     APG0500           RF Cable S-AR                     7-2-2019
 A01982                    Rohde &      ESR7              EMI Test Receiver 7GHz            6-7-2019
                           Schwarz
 A00008                    Emco         3115              Guide ant. 1-18GHz                19-12-2020
 A00009                    Emco         3115              Guide ant. 1-18GHz                13-2-2019
 A00011                    Emco         3116              Guide ant. 18-40GHz               13-2-2019
 A00012                    Emco         3160-09           Gain horn 18-26.5GHz              13-2-2019
 A00209                    Emco         3160-09           Gain horn 18-26.5GHz              13-2-2019
 A00210                    Emco         3160-10           Gain horn 26.5-40GHz              13-2-2019
 A00339                    H&S          Sucotest          Cable RF S-AR >1G setup           13-7-2019
                                        18/Sucoflex 102
 A00340                    H&S          Sucotest          Cable RF                          12-7-2019
                                        18/Sucoflex 102
 A00341                    H&S          Sucotest          Cable RF                          12-7-2019
                                        18/Sucoflex 102




                                                                                                               Rev.:01


Produkte
Products


 Prufbericht-Nr: 18121105.f01                                       Seite 3 von 29
 Test report No: 18121105.f01                                        Page 3 of 29



 1   Produktdetails                Wireless Communication Card 9260D2WL
     Product details

 2   Maße / Gewicht                                << 50 gr
     Dimensions / Weight

 3   Bedienelemente                Built inside Extender, processed by laptop
     Operating elements

 4   Ausstattung / Zubehör      Extender card CRF CNV10 DB M2 PCB00651_01
     Equipment / Accessories

 5   Verwendete Materialien                    PCB/Components
     Used materials

 6   Sonstiges                         Tested in external Extender card
     Other

 7   This report concerns:          EMC Verification




                                                                                Rev.:01


Produkte
Products


 Prufbericht-Nr: 18121105.f01                                                                       Seite 4 von 29
 Test report No: 18121105.f01                                                                        Page 4 of 29




 Absatz
 Clause     Anforderungen – Prüfungen / Requirements - Tests
 1          47 CFR Part 15 (10-1-17 Edition) - 15.107(a)                  AC Power Line Conducted          P
            ICES-003 (Issue 6, January 2016) –                            Emissions                        F
            Section 6.1 Table 2                                                                            N/A
                                                                                                           N/T

 2          47 CFR Part 15 (10-1-17 Edition) - 15.109                     Radiated unwanted emissions      P
            ICES-003 (Issue 6, January 2016) –                                                             F
            Section 6.2.1 Table 5                                                                          N/A
                                                                                                           N/T




                                       Zusammenfassung der Prüfergebnisse
                                            Summary of test results
 Index     Prüfung                  Anwendbar     Prüfergebnis   Paragraf     Messungen un-      Kommentar
 Index     Test                      Applicable    Test result   Paragraph    ter Akkreditie-    Remark
                                                                               rung ausge-
                                                                                   führt
                                                                              under accredita-
                                                                                    tion
           Radiated emission
 Page 11                               Yes           Pass           3.1            Yes
             < 1000 MHz
           Radiated emission
 Page 15                               Yes           Pass           3.2            Yes
             > 1000 GHz
            Conducted emis-
 Page 23                               Yes           Pass           3.3            Yes
            sion AC/DC port




                                                                                                                 Rev.:01


Produkte
Products


    Prufbericht-Nr: 18121105.f01                                                                                                                        Seite 5 von 29
    Test report No: 18121105.f01                                                                                                                         Page 5 of 29



Table of contents
1     General test configuration. .................................................................................................................................... 7
    1.1      Tested system auxiliary details. .................................................................................................................... 8
    1.2      Test methodology. ........................................................................................................................................ 9
    1.3      Test facility. ................................................................................................................................................... 9
    1.4      Test conditions. ............................................................................................................................................. 9
2     System test configuration. .................................................................................................................................... 9
    2.1      Justification. .................................................................................................................................................. 9
    2.2      EUT mode of operation. ................................................................................................................................ 9
    2.3      Special accessories. ................................................................................................................................... 10
    2.4      Equipment modifications. ............................................................................................................................ 10
3     Test results Emission according to FCC CRF47 Part 15B ................................................................................. 11
    3.1      Enclosure Radiated Emission 30-1000 MHz .............................................................................................. 11
    3.2      Enclosure Radiated emission 1GHz – 30GHz ............................................................................................ 15
    3.3      AC Mains Conducted Emission 0.15-30 MHz ............................................................................................ 23




                                                                                                                                                                            Rev.:01


Produkte
Products


 Prufbericht-Nr: 18121105.f01                                                  Seite 6 von 29
 Test report No: 18121105.f01                                                   Page 6 of 29



                                                            Revisions
                                                            Revisions

   Revision               Datum             Anmerkung                   Verfasser
   Revision                Date             Remark                       Author
       00             Feb 11, 2019          First Release               W. Brouwer




 Note: Latest revision report will replace all previous reports




                                                                                           Rev.:01


Produkte
Products


 Prufbericht-Nr: 18121105.f01                                                               Seite 7 von 29
 Test report No: 18121105.f01                                                                Page 7 of 29



CONDITIONS FOR TESTING

1   General test configuration.




 Test item                     Wireless Communication Card
 Model                         9260D2WL
 Manufacturer                  Intel Corporation SAS, Le Cargo B6 / 424 Rue de Goa, 06600 Antibes, France
 Voltage input rating          Powered by extension board around 2-5 V DC
 Current input rating          n.a.

 Test software                 Intel ProSet
 Driver version                20.115.0.4
 Auxiliary Equipment           See drawing in 1.1

 Remarks                       EUT tested in external extension board




                                                List of used cables
     Number             Function              From               To           Length            Remarks
           1              AC                  Mains            Laptop            <3




                                                                                                            Rev.:01


 Produkte
 Products


  Prufbericht-Nr: 18121105.f01                                                                     Seite 8 von 29
  Test report No: 18121105.f01                                                                      Page 8 of 29



 1.1   Tested system auxiliary details.

 Details and an overview of the system and all of its components, as it has been tested, may be found below.

 Test item (EUT1)                : Wireless Communication Card
 Manufacturer                    : Intel Corporation SAS
 Brand mark                      : Intel
 Model                           : 9260D2WL
 Serial number                   : Engineering Sample
 Remark                          : Tested in Extender board

 Test item (AUX1)                : Extender Main and Card board
 Manufacturer                    : Intel Corporation SAS
 Brand mark                      : Intel
 Model                           : CRF CNVIO DB M2
 Serial number                   : PCB00651_01
 Remark                          : Used to have a functional EUT outside a PC or laptop

 Test item (AUX2)                : Laptop
 Manufacturer                    : Dell
 Brand mark                      : Dell
 Model                           : E5470
 Serial number                   : ---
 Remark                          : Used as Host for AUX 1

 Test item (AUX3)                : Mobile Phone
 Manufacturer                    : Samsung
 Brand mark                      : Samsung
 Model                           : Galaxy J7 (2016)
 Serial number                   : ---
 Remark                          : Used for BT communication

                               Blue ribbon cable enabling
                               data communication
                               between Aux 1 and Aux2
Power Supply
                      Aux2 laptop                        Aux1                          Power Supply
                                                         Extender
                                                         board with
                                                         EUT


                              USB cable enabling BT
                              data communication
                              between Aux 1 and Aux2

 120 VAC 60 Hz                                                            120 VAC 60 Hz

                                                       AUX3, used in
                                                       BT mode




                          Figure 1. Total set-up used during testing                                           Rev.:01


Produkte
Products


 Prufbericht-Nr: 18121105.f01                                                                         Seite 9 von 29
 Test report No: 18121105.f01                                                                          Page 9 of 29




1.2   Test methodology.

The test methodology used is based on the requirements of 47 CFR Part 15 (10-1-17 Edition), sections 15.31,
15.107 and 15.109 and ICES-003 Issue 6 (January 2016) Sections 6.1 and 6.2. The EUT was tested in horizontal
position only and is regarded as Table Top equipment.

The test methods, which have been used, are based on ANSI C63.4-2014.

Radiated emission tests were performed at a measurement distance of 3 meters.
The receivers are switching automatically to the right bandwidth in accordance with CISPR 16. This is implemented
in the receiver. The antenna factors are programmed in the test receiver. The receiver automatically calculates the
appropriate correction factor for the utilized antenna and also the appropriate antenna factor for the cable loss. The
total correction is automatically added to the measured value.

1.3   Test facility.

The Federal Communications Commission and Industry Canada has reviewed the technical characteristics of the
test facilities at TÜV Rheinland Nederland B.V., located at Eiberkamp 10, 9351 VT Leek, The Netherlands, and has
found these test facilities to be in compliance with the requirements of 47 CFR Part 15, section 2.948.

The description of the test facilities has been filed at the Office of the Federal Communications Commission under
registration number 786213. The facility has been added to the list of laboratories performing these test services for
the public on a fee basis.

The description of the test facilities has been filed to Industry Canada under registration number 2932G-2. The
facility has been added to the list of laboratories performing these test services for the public on a fee basis.


1.4   Test conditions.

Normal test conditions:

Temperature (*)           : +15°C to +35°C
Relative humidity(*)      : 20 % to 75 %
Supply voltage            : 120 Vac / 60 Hz

*When it was impracticable to carry out the tests under these conditions, a note to this effect stating the ambient
temperature and relative humidity during the tests are stated separately.


2     System test configuration.
2.1   Justification.

The system was configured for testing in a typical situation as a customer would normally use it. The test sample
was configured by the applicant to enable continuous transmit. A normal 2.4 and/or 5 GHz Internet Link has been
built-up to enable communication

The justification and manipulation of cables and equipment in order to simulate a worst-case behavior of the test
setup has been carried out as prescribed in ANSI C63.4-2014.

2.2   EUT mode of operation.

The unintentional radiator tests have been performed with a complete functioning EUT.


                                                                                                                      Rev.:01


Produkte
Products


 Prufbericht-Nr: 18121105.f01                                          Seite 10 von 29
 Test report No: 18121105.f01                                           Page 10 of 29




2.3   Special accessories.

No special accessories are used and/or needed to achieve compliance.

2.4   Equipment modifications.

No modifications have been made to the equipment.




                                                                                    Rev.:01


Produkte
Products


 Prufbericht-Nr: 18121105.f01                                                                          Seite 11 von 29
 Test report No: 18121105.f01                                                                           Page 11 of 29


3 Test results Emission according to FCC CRF47 Part 15B

3.1     Enclosure Radiated Emission 30-1000 MHz

3.1.1    Definition

Result of the measurements concerning radiated electromagnetic fields (electric component) emitted by the
total set-up of the EUT.


3.1.2    Basic standard

The test is performed according to FCC CRF 47 Part 15B § 15.109

3.1.3    Limit

FCC 15.109(a) and IC ICES-003 section 6.2
Except for Class A digital devices, the field strength of radiated emissions from an unintentional radiator shall
not exceed the field strength levels specified in the following table:

         Frequency                 Field strength               Field strength         Measurement distance
           (MHz)                     (μV/meter)                   (dBμV/m)                   (meters)
            30-88                        100                            40.0                       3
           88-216                        150                            43.5                       3
           216-960                       200                            46.0                       3
         Above 960                       500                            54.0                       3

                                           Table of Applicable Limits


3.1.4    Test procedures

ANSI C63.4-2014.

Before final measurements of radiated emissions were performed, the EUT was scanned to determine its
emission spectrum profile. The physical arrangement of the test system, the associated cabling and the EUT
orientation (X, Y, Z) were varied in order to ensure that maximum emission amplitudes were attained.
The spectrum was examined from 30MHz to 25 GHz, the fifth harmonic of the implemented WLAN module.
Final radiated emission measurements were made at 3 m distance.
At each frequency where a spurious emission was found, the EUT was rotated 360° and the antenna was
raised and lowered from 1 to 4 m in order to determine the emission’s maximum level. Measurements were
taken using both horizontal and vertical antenna polarizations.
The highest emission amplitudes relative to the appropriate limit were recorded in this report. Field strength
values of radiated emissions at frequencies not listed in the tables are more than 20 dB below the applicable
limit.

3.1.5    Test deviation

There is no deviation with the original standard


Produkte
Products


 Prufbericht-Nr: 18121105.f01                                                                     Seite 12 von 29
 Test report No: 18121105.f01                                                                      Page 12 of 29



3.1.6     Test results

                                               Test conditions
 Ambient temperature (0C)       22.5                          Relative humidity (%)     33.6
 Air pressure (hPa)             1020                          Test location             Leek
 Applied Standard(s)            47 CFR Part 15 (10-1-17
                                Edition), ICES-003, January
                                2016)
 Test engineer                  W. Brouwer                    Test result               Pass
 Test date                                                    Signature:
                                Feb 6 – Feb 7, 2019



3.1.6.1    Test results 2.4 GHz WiFi Mode
                                           Results and limits 2.4 GHz mode
  Frequency            Result        Antenna po-         Limit         Margin            Height           Angle
    (MHz)            (dBV/m)         larization      (dBV/m)                            (cm)            (deg)
     30.10              23.5           Vertical          40.0           16.5              99.7            224.8
     64.41              23.7           Vertical          40.0           16.3              99.6            211.1
    111.16              21.3           Vertical          43.5           22.2              99.7             78.1
    264.00              32.3          Horizontal         46.0           13.7             100.1            271.8
    330.96              23.7          Horizontal         46.0           22.3             100.3            271.2
    408.00              35.9          Horizontal         46.0           10.1              99.7            115.3

                         Table 1 Results Enclosure Radiated Emission 30.0 – 1000 MHz


3.1.6.2    Test results 5 GHz WiFi Mode and BT Mode
                                       Results and limits 5 GHz and BT mode
  Frequency            Result        Antenna po-        Limit        Margin              Height           Angle
    (MHz)            (dBV/m)         larization     (dBV/m)                             (cm)            (deg)
     31.98              25.2           Vertical         40.0           14.8               99.7            215.1
    111.93              21.4           Vertical         43.5           22.1               99.7             90.4
    168.00              27.1          Horizontal        43.5           16.4              118.5            244.3
    181.77              20.2           Vertical         43.5           23.3               99.6            209.1
    228.86              26.3          Horizontal        46.0           19.7               99.7            232.1
    408.00              39.0           Vertical         46.0            7.0               99.7            205.7

                         Table 2 Results Enclosure Radiated Emission 30.0 – 1000 MHz


Used Equipment
 A01982 A00029           A00235    A00313    A00447     A00466

Notes:

    1. Field strength values of radiated emissions at frequencies not listed in the table above are more than
       25 dB below the applicable limit.
    2. Measurement uncertainty is 5.1 dB.
    3. The EUT was tested in horizontal orientation only-it’s normal operation orientation, the measuring
       antenna was varied in horizontal and vertical orientations and also around its axis and height. The
       reported value is the worst case found at the reported frequency.
    4. A selection of Photos and Graphical Displays is provided on the next pages.
                                                                                                                Rev.:01


Produkte
Products


 Prufbericht-Nr: 18121105.f01                                                          Seite 13 von 29
 Test report No: 18121105.f01                                                           Page 13 of 29




3.1.6.3    Photograph test setup




                        Photo 1 Photograph test setup radiated emissions 30-1000 MHz




                                                                                                 Rev.:01


Produkte
Products


 Prufbericht-Nr: 18121105.f01                                                                            Seite 14 von 29
 Test report No: 18121105.f01                                                                             Page 14 of 29



3.1.6.4    Spectrum plot




          Plot 1: Pre-scan plot with peak detector. Radiated emissions from 30 MHz to 1000 MHz, 2.4GHz mode.




     Plot 2: Pre-scan plot with peak detector. Radiated emissions from 30 MHz to 1000 MHz, 5GHz and BT mode.
                                                                                                                   Rev.:01


Produkte
Products


 Prufbericht-Nr: 18121105.f01                                                               Seite 15 von 29
 Test report No: 18121105.f01                                                                Page 15 of 29



3.2      Enclosure Radiated emission 1GHz – 30GHz
3.2.1     2.4 GHz WiFi Mode

                                       Results and limits 2.4 GHz mode
  Frequency                     Peak Results                             Average Results
                   Horizontal       Vertical      Limit       Horizontal     Vertical       Limit
        (GHz)      (dBV/m)        (dBV/m)     (dBV/m)      (dBV/m)      (dBV/m)      (dBV/m)
         1.06         39.6           42.1          74.0         24.3           24.7         54.0
         1.32         40.1           42.8          74.0         26.3           28.7         54.0
         1.20         47.6           49.7          74.0         30.1           30.1         54.0
         3.06         50.1           49.6          74.0         35.5           35.6         54.0
         5.53         60.4           60.3          74.0         46.3           46.3         54.0
         5.89         62.4           62.4          74.0         48.5           48.5         54.0
         7.96         51.8           50.5          74.0         40.1           40.3         54.0
         8.42         51.9           51.6          74.0         39.2           38.8         54.0
         9.78         52.8           52.9          74.0         39.2           38.9         54.0
        11.49         60.8           59.7          74.0         48.7           49.3         54.0
        17.94         67.2           65.3          74.0         52.4           53.3         54.0
        19.27         51.7           51.5          74.0         41.2           41.5         54.0
        21.25         51.7           51.5          74.0         42.3           42.4         54.0
        23.46         50.2           51.2          74.0         40.8           40.9         54.0
        29.17         51.8           53.2          74.0         42.8           42.3         54.0
                  Table 3 Results Enclosure Radiated Emission 1 GHz – 30 GHz, 2.4GHz mode

3.2.2     5 GHz WiFi Mode and BT Mode

                                     Results and limits 5 GHz and BT mode
  Frequency                      Peak Results                            Average Results
                    Horizontal       Vertical      Limit      Horizontal       Vertical       Limit
        (GHz)        (dBV/m)       (dBV/m)     (dBV/m)      (dBV/m)       (dBV/m)     (dBV/m)
         1.03           38.1          38.3          74.0         24.3           24.3          54.0
         1.42           39.3          44.9          74.0         25.6           26.1          54.0
         1.60           41.6          43.9          74.0         27.1           27.1          54.0
         2.13           45.5          50.8          74.0         31.0           32.1          54.0
         3.00           49.0          51.1          74.0         35.1           35.2          54.0
         4.84           66.9          61.2          74.0         42.7           42.5          54.0
         5.89           64.3          62.5          74.0         48.6           48.6          54.0
         6.56           53.2          52.8          74.0         40.3           40.5          54.0
         7.44           53.5          51.5          74.0         38.7           39.0          54.0
         7.91           51.0          52.0          74.0         39.4           39.3          54.0
        11.49           59.9          60.9          74.0         48.2           48.0          54.0
        14.13           55.9          55.9          74.0         43.8           43.9          54.0
        17.98           65.5          65.8          74.0         53.5           53.5          54.0
        20.05           52.7          53.5          74.0         51.8           51.2          54.0
        21.23           52.8          52.6          74.0         52.7           52.1          54.0
        29.12           52.6          53.2          74.0         51.8           52.7          54.0
                Table 4 Results Enclosure Radiated Emission 1 GHz – 30 GHz, 5 GHz and BT mode




                                                                                                      Rev.:01


Produkte
Products


 Prufbericht-Nr: 18121105.f01                                                                      Seite 16 von 29
 Test report No: 18121105.f01                                                                       Page 16 of 29



Notes:

Field strength values of radiated emissions at frequencies not listed in the table above are more than 25 dB
below the applicable limit.
1.        Measurement uncertainty is +/- 5.13 dB
2.       The reported field strength values are the worst case values at the indicated frequency. The
         receiving antenna was varied in horizontal and vertical orientations and also in height (between 1m
         and 2m).
3.       A Peak and Average detector was used with a resolution bandwidth of 1MHz.

Used Equipment
 A01982    A00337      A00338     A00235     A00313     A00447     A00008




                                                                                                               Rev.:01


Produkte
Products


 Prufbericht-Nr: 18121105.f01                                                   Seite 17 von 29
 Test report No: 18121105.f01                                                    Page 17 of 29



Photograph test setup 1- 6 GHz




                             Photo 2: Photograph radiated emissions 1 – 6 GHz




                                                                                          Rev.:01


Produkte
Products


 Prufbericht-Nr: 18121105.f01                                                     Seite 18 von 29
 Test report No: 18121105.f01                                                      Page 18 of 29



3.2.3   test setup 6-18 GHz




                              Photo 3: Photograph radiated emissions 6 – 18 GHz




                                                                                            Rev.:01


Produkte
Products


 Prufbericht-Nr: 18121105.f01                                                   Seite 19 von 29
 Test report No: 18121105.f01                                                    Page 19 of 29



3.2.4   test setup 18-30 GHz




                           Photo 4: Photograph radiated emissions 18 – 30 GHz




                                                                                          Rev.:01


Produkte
Products


 Prufbericht-Nr: 18121105.f01                                                                          Seite 20 von 29
 Test report No: 18121105.f01                                                                           Page 20 of 29



3.2.5   Spectrum plot 2.4 GHz WiFi Mode




           Plot 3: Pre-scan plot with peak detector. Radiated emissions from 1 GHz – 6 GHz, 2.4 GHz mode


3.2.6   Spectrum plot 5 GHz WiFi Mode and BT Mode, 1 – 6 GHz




        Plot 4: Pre-scan plot with peak detector. Radiated emissions from 1 GHz – 6 GHz, 5 GHz and BT mode
                                                                                                                 Rev.:01


Produkte
Products


 Prufbericht-Nr: 18121105.f01                                                                            Seite 21 von 29
 Test report No: 18121105.f01                                                                             Page 21 of 29



3.2.7      Spectrum plot 2.4 GHz WiFi Mode, 6 – 18 GHz




          Plot 5: Pre-scan plot with peak detector. Radiated emissions from 6 GHz – 18 GHz, 2.4 GHz WIFI mode


3.2.8      Spectrum plot 5 GHz WiFi Mode and BT Mode, 6 – 18 GHz




        Plot 6: Pre-scan plot with peak detector. Radiated emissions from 6 GHz – 18 GHz, 5 GHz WIFI and BT mode
                                                                                                                   Rev.:01


Produkte
Products


 Prufbericht-Nr: 18121105.f01                                                                           Seite 22 von 29
 Test report No: 18121105.f01                                                                            Page 22 of 29



3.2.9   Spectrum plot 2.4 GHz WiFi Mode , 18 – 30 GHz




        Plot 7: Pre-scan plot with peak detector. Radiated emissions from 18 GHz - 30 GHz, 2.4 GHz WIFI mode



3.2.10 Spectrum plot 5 GHz WiFi Mode and BT Mode, 18 – 30 GHz




    Plot 8: Pre-scan plot with peak detector. Radiated emissions from 18 GHz – 30 GHz, 5 GHz WIFI and BT mode

                                                                                                                  Rev.:01


Produkte
Products


 Prufbericht-Nr: 18121105.f01                                                                    Seite 23 von 29
 Test report No: 18121105.f01                                                                     Page 23 of 29



3.3 AC Mains Conducted Emission 0.15-30 MHz
3.3.1   Definition

Result of the measurements concerning the disturbance voltage level at the power input port emitted by the
total set-up of the EUT.

3.3.2   Basic standard

The test is performed according to FCC CRF 47 Part 15B § 15.107

3.3.3   Limit

                                   Limit                    Limit
   Frequency (MHz)
                             Quasi-peak(dBV)          Average(dBV)
        0.15 - 0.50             66.0 – 56.0            56.0 – 46.0
         0.50 - 5.0                56.0                      46.0
        5.0 – 30.0                 60.0                      50.0

3.3.4   Test procedures

Requirements: 15.107 (a) Except for Class A digital devices, for equipment that is designed to be connected
to the public utility (AC) power line, the radio frequency voltage that is conducted back onto the AC power
line on any frequency or frequencies within the band 150 kHz to 30 MHz shall not exceed the limits in the
following table, as measured using a 50 μH/50 ohms line impedance stabilization network (LISN).
Compliance with the provisions of this paragraph shall be based on the measurement of the radio frequency
voltage between each power line and ground at the power terminal. The lower limit applies at the band
edges.
Test procedure according to ANSI C63.4-2014: Each phase and neutral of the AC power line were measured
with respect to ground. Measurements were performed using a 50 µH / 50 Ω LISN. The frequency range
from 150kHz to 30MHz was searched. The six highest EUT emissions relative to the limit were noted. The
EUT is regarded as floor standing equipment and no isolating plane was used since the EUT is already
provided with isolating material (of max 12mm height) underneath. The EUT was positioned at least 40cm
from a vertical ground reference plane and at least 80cm from the LISN.

3.3.5 Test deviation
There is no deviation with the original standard

3.3.6   Test results
                                               Test conditions
 Ambient temperature
                            21.5                      Relative humidity (%)     30.2
 (0C)
 Air pressure (hPa)         950-1050                  Test location             Leek
                            47 CFR Part 15 (10-1-
 Applied Standard(s)        17 Edition), ICES-003,
                            January 2016)
 Test engineer              W. Brouwer                Test result               Pass

 Test date                  Feb 1, 2019               Signature




                                                                                                              Rev.:01


Produkte
Products


 Prufbericht-Nr: 18121105.f01                                                             Seite 24 von 29
 Test report No: 18121105.f01                                                              Page 24 of 29



3.3.6.1    Results 2.4 GHz WiFi Mode

                                     Results and limits Neutral
     Frequency                Quasi peak detector                      Average detector
       (MHz)            Result       Limit        Margin        Result       Limit        Margin
          0.19           41.2         64.0         22.9          23.4        54.0          30.7
          0.27           33.8         61.1         27.3          21.0        51.1          30.1
          0.48           29.0         56.3         27.4          18.1        46.3          28.3
          3.16           31.6         56.0         24.4          26.5        46.0          19.5
          3.52           30.7         56.0         25.4          24.1        46.0          21.9
                          Table 5 Results Conducted Emission 0.15 - 30 MHz

                                       Results and limits L1
     Frequency                Quasi peak detector                      Average detector
       (MHz)            Result       Limit        Margin        Result       Limit        Margin
          0.19           38.6         64.0         25.5          21.7        54.0          32.4
          0.27           33.7         61.1         27.5          20.7        51.1          30.5
          0.48           28.6         56.3         27.7          17.5        46.3          28.8
          3.16           33.5         56.0         22.5          27.8        46.0          18.2
          3.52           31.1         56.0         24.9          25.0        46.0          21.0
                          Table 6 Results Conducted Emission 0.15 - 30 MHz




                                                                                                    Rev.:01


Produkte
Products


 Prufbericht-Nr: 18121105.f01                                                                        Seite 25 von 29
 Test report No: 18121105.f01                                                                         Page 25 of 29




3.3.6.2    Results 5 GHz WiFi Mode and BT Mode

                                          Results and limits Neutral
     Frequency                     Quasi peak detector                            Average detector
       (MHz)                Result       Limit        Margin        Result             Limit         Margin
          0.15               42.0         66.0         24.0          30.0              56.0           26.0
          0.25               34.1         61.8         27.7          22.7              51.8           29.1
          0.47               30.5         56.5         26.0          18.0              46.5           28.6
          2.21               26.1         56.0         29.9          18.6              46.0           27.4
          3.08               29.0         56.0         27.0          22.4              46.0           23.6
          3.54               30.3         56.0         25.7          22.4              46.0           23.6
                              Table 7 Results Conducted Emission 0.15 - 30 MHz

                                            Results and limits L1
     Frequency                     Quasi peak detector                            Average detector
       (MHz)                Result       Limit        Margin        Result             Limit         Margin
          0.15               41.9         66.0         24.1          26.9              56.0           29.1
          0.25               34.2         61.8         27.6          22.9              51.8           28.9
          0.47               30.5         56.5         26.0          17.2              46.5           29.4
          2.21               28.6         56.0         27.4          22.4              46.0           23.6
          3.08               32.5         56.0         23.5          25.2              46.0           20.9
          3.54               33.4         56.0         22.6          24.8              46.0           21.2
                              Table 8 Results Conducted Emission 0.15 - 30 MHz

The results of the AC power line conducted emission tests, carried out in accordance with 47 CFR Part 15
section 15.107 and ICES-003 Section 6.1, at the 120 Volts AC mains connection terminals of Aux2 of the
system, are depicted in Table 5 -8. Maximum values were recorded. The system is tested as in whole, so
with all equipment as shown in Figure 1 in place and functioning. Being the worst case situation.

Notes:

    1.     Measurement uncertainty is 3.2dB
    2.     The resolution bandwidth used was 9 kHz.
    3.     The six highest values relative to the applicable limits were noted.
    4.     Photo and Graphical Display is provided on the next page.

Used Equipment
 A00726 A01978           A00022     A00354      A00093




                                                                                                               Rev.:01


Produkte
Products


 Prufbericht-Nr: 18121105.f01                                                     Seite 26 von 29
 Test report No: 18121105.f01                                                      Page 26 of 29



3.3.6.3    Photograph test setup




                            Photo 5: Photograph conducted emissions 0.15-30 MHz




                                                                                            Rev.:01


Produkte
Products


 Prufbericht-Nr: 18121105.f01                                                                            Seite 27 von 29
 Test report No: 18121105.f01                                                                             Page 27 of 29




3.3.6.4    Spectrum plot 2.4 GHz Mode




          Plot 9: Pre-scan plot with peak detector. Conducted emissions from 0.15 - 30 MHz, 2.4 GHz WIFI mode




                                                                                                                   Rev.:01


Produkte
Products


 Prufbericht-Nr: 18121105.f01                                                                         Seite 28 von 29
 Test report No: 18121105.f01                                                                          Page 28 of 29



3.3.6.5    Spectrum plot 5 GHz Mode and BT Mode




    Plot 10: Pre-scan plot with peak detector. Conducted emissions from 0.15 - 30 MHz, 5 GHz WIFI and BT mode




                                                                                                                Rev.:01


Produkte
Products


 Prufbericht-Nr: 18121105.f01                           Seite 29 von 29
 Test report No: 18121105.f01                            Page 29 of 29




                           END OF THIS EMC TESTREPORT




                                                                  Rev.:01



Document Created: 2019-02-15 09:38:35
Document Modified: 2019-02-15 09:38:35

© 2025 FCC.report
This site is not affiliated with or endorsed by the FCC