RF Exposure Info

FCC ID: PD98260NG

RF Exposure Info

Download: PDF
FCCID_3248480

                                                                                        Report No.: 1560147R-RFUSP02V00




                  RF Exposure Evaluation declaration



                       Product Name : Intel® Dual Band Wireless-AC 8260
                       Model No.             : 8260NGW
                       FCC ID                : PD98260NG, PD98260NGU




Applicant       : Intel Mobile Communications
Address         : 100 Center Point Circle, Suite 200 Columbia, South Carolina 29210 USA




                                Date of Receipt          : June 03, 2015

                                Date of Declaration : Oct. 20, 2016

                                Report No.               : 1560147R-RFUSP02V00




 The test results relate only to the samples tested.
 The test results shown in the test report are traceable to the national/international standard through the calibration report of
 the equipment and evaluated measurement uncertainty herein.
 This report must not be used to claim product endorsement by TAF or any agency of the government.
 The test report shall not be reproduced without the written approval of QuieTek Corporation.



                                                         Page: 1 of 4


                                                                  Report No.: 1560147R-RFUSP02V00




                                                      Issued Date: Oct. 20, 2016
                                                      Report No.: 1560147R-RFUSP02V00




Product Name        Intel® Dual Band Wireless-AC 8260

Applicant           Intel Mobile Communications

Address             100 Center Point Circle, Suite 200 Columbia, South Carolina 29210 USA

Manufacturer        Intel Mobile Communications

Model No.           8260NGW

FCC ID.             PD98260NG, PD98260NGU

EUT Rated Voltage   DC 3.3V (via Mini-PCI Express slot)

EUT Test Voltage    AC 120V/60Hz

Trade Name          Intel

Applicable Standard FCC 47 CFR 1.1310

Test Result         Complied




Documented By       :

                                      ( Senior Adm. Specialist / Jinn Chen )

Tested By           :

                                             ( Engineer / Nick Chen )

Approved By         :


                                            ( Director / Vincent Lin )




                                       Page: 2 of 4


                                                                            Report No.: 1560147R-RFUSP02V00




1.      RF Exposure Evaluation

1.1.    Limits

        According to FCC 1.1310: The criteria listed in the following table shall be used to evaluate the
        environment impact of human exposure to radio frequency (RF) radiation as specified in 1.1307(b)
        LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE)
        Frequency Range       Electric Field       Magnetic Field      Power Density        Average Time
                                                                                 2
        (MHz)                 Strength (V/m)       Strength (A/m)      (mW/cm )             (Minutes)
                                    (A) Limits for Occupational/ Control Exposures
               300-1500                  --                  --               F/300                  6
           1500-100,000                  --                  --                  5                   6
                              (B) Limits for General Population/ Uncontrolled Exposures
               300-1500                  --                  --               F/1500                 6
           1500-100,000                  --                  --                  1                   30
        F= Frequency in MHz


       Friis Formula
       Friis transmission formula: Pd = (Pout*G)/(4*pi*r2)


       Where
       Pd = power density in mW/cm2
       Pout = output power to antenna in mW
       G = gain of antenna in linear scale
       Pi = 3.1416
       R = distance between observation point and center of the radiator in cm


       Pd id the limit of MPE, 1 mW/cm2 . If we know the maximum gain of the antenna and the total power
       input to the antenna, through the calculation, we will know the distance r where the MPE limit is
       reached.



1.2.    Test Procedure

         Software provided by client enabled the EUT to transmit and receive data at lowest, middle and
         highest channel individually.
         The temperature and related humidity: 18℃and 78% RH.


                                                 Page: 3 of 4


                                                                          Report No.: 1560147R-RFUSP02V00




1.3.     Test Result of RF Exposure Evaluation

         Product       :     Intel® Dual Band Wireless-AC 8260
         Test Item     :     RF Exposure Evaluation
         Test Site     :     No.3 OATS


       For 2.4GHz:
        Operation Frequency Range      2412-2467MHz, 2422-2457MHz,
                                       2402-2480MHz
        Maximum Conducted output power 25.37dBm
        Antenna gain                   2.89dBi


       Output Power Into Antenna & RF Exposure Evaluation Distance:
           Output Power to Antenna (mW)                 Power Density at R = 20 cm (mW/cm2)
                     344.3499308                                     0.133269
        Power density is lower than the limit (1 mW/cm2).


        For 5GHz:
        Operation Frequency Range      5180-5240MHz, 5260-5320MHz,
                                       5500-5700MHz, 5745-5825MHz,
                                       5190-5230MHz, 5270-5310MHz,
                                       5510-5670MHz, 5755-5795MHz,
                                       5720 MHz, 5710MHz, 5210-5290MHz,
                                       5530-5690MHz, 5775MHz
        Maximum Conducted output power 21.71dBm
        Antenna gain                   4.41dBi


       Output Power Into Antenna & RF Exposure Evaluation Distance:
           Output Power to Antenna (mW)                 Power Density at R = 20 cm (mW/cm2)
                     148.2518085                                     0.081420
        Power density is lower than the limit (1 mW/cm2).




                                                  Page: 4 of 4



Document Created: 2016-12-14 11:16:53
Document Modified: 2016-12-14 11:16:53