MPE prediction

FCC ID: PD92011BWLAN

RF Exposure Info

Download: PDF
FCCID_157387

              Prediction of MPE limit at a given distance

    Equation from page 18 of OET Bulletin 65, Edition 97-01
                    PG
             S =
                   4πR 2
    where:   S = power density
             P = power input to the antenna
             G = power gain of the antenna in the direction of interest relative to an isotropic radiator
             R = distance to the center of radiation of the antenna


     Maximum peak output power at antenna input terminal:      17.00 (dBm)
     Maximum peak output power at antenna input terminal: 50.11872 (mW)
                                        Antenna gain(typical):     5 (dBi)
                                     Maximum antenna gain: 3.162278 (numeric)
                                          Prediction distance:    20 (cm)
                                         Prediction frequency:  2400 (MHz)
  MPE limit for uncontrolled exposure at prediction frequency:     1 (mW/cm^2)

                      Power density at prediction frequency:     0.03153 (mW/cm^2)

                          Maximum allowable antenna gain:        20.0127 (dBi)

This prediction, along with the following photograph, demonstrate the following:

1) The power density levels at a distance of 20 cm. are well below the maximum levels allowed
   by the FCC regulations. At a distance of 5 cm. the power density levels are still below the
   maximum specified by the FCC regulations.
2) A minimum separation distance of 20 cm. can practically be maintained during normal use of
   the equipment.