RF Exposure

FCC ID: PBR-SZG2ZBNCR1

RF Exposure Info

Download: PDF
FCCID_4394232

Produkte                                            www.tuv.com
Products
                               Reference Test Report No:                                           Seite 1 von 2
RF Exposure                    ULRTC568819300000048F 001                                            Page 1 of 2


1 RF Exposure Report
   1.1 RF Exposure Measurement
The limit for Maximum Permissible Exposure (MPE) specified in FCC 1.1310 and RSS 102, Issue 5, Section 2.5.2 is
followed. The gain of the antennas used in the product is extracted from the Antenna data sheets provided and also
the maximum total power input to the antenna is measured. Through the Friis transmission formula and the
maximum gain of the antenna, we can calculate the distance, away from the product, where the limit of MPE is
reached.
Although the Friis Transmission formula is far field assumption, the calculated result of that is an over-prediction for
near field power density. It is taken as worst case to specify the safety range.


   1.2 RF Exposure Limit
According to FCC 1.1310: The criteria listed in the following table shall be used to evaluate the environmental
impact of the human exposure to radio-frequency (RF) radiation as specified in 1.1307 (b) showed in Table 1. And
as per the RSS 102, Issue 5, Section 2.5.2 the MPE limits mentioned in Table 2.


                     Table 1: Limits for Maximum Permissible Exposure (MPE) as per FCC
              Frequency Range           Electric Field         Magnetic Field          Power Density
                     (MHz)              Strength (V/m)         Strength (A/m)             (mW/cm²)
                                   Limits for Occupational / controlled Exposures
                  300 - 1500                   --                     --                    F/300
                1500 – 100000                  --                     --                     5.0
                               Limits for General population / Uncontrolled Exposure
                  300 - 1500                   --                     --                   F/1500
                1500 – 100000                  --                     --                     1.0


F or ƒ = Frequency in MHz


                 Table 2: Limits for Maximum Permissible Exposure (MPE) as per ISED Canada
               Frequency Range           Electric Field        Magnetic Field          Power Density
                     (MHz)                (V/m rms)               (A/m rms)              (mW/cm²)
                                   Limits for Occupational / controlled Exposures
                   100-6000              15.60ƒ0.25             0.04138ƒ0.25               3.1950
                               Limits for General population / Uncontrolled Exposure
                   300-6000             3.142 ƒ0.3417         0.008335ƒ0.3417              0.5423
F or ƒ = Frequency in MHz


Produkte                                           www.tuv.com
Products
                                Reference Test Report No:                                    Seite 2 von 2
RF Exposure                     ULRTC568819300000048F 001                                     Page 2 of 2


       1.2.1      Friss Formula

       Friss Transmission Formula: Pd = (Pout * G) / (4*pi*r²)

       Where
       Pd = power density in mW/cm²
       Pout = output power to antenna in mW
       G = gain of antenna in linear scale
       Pi = 3.1416
       R = Distance between observation point and the center of radiator in cm

       If we know the maximum gain of the antenna and the total output power to the antenna, through
       calculation, we will know MPE value at distance 20cm.

       1.2.2      EUT Operation condition
       EUT was enabled to transmit and receive at lowest, middle and highest channels.

       1.2.3      Classification
       The antenna of this product, under normal use condition, is at least 20cm away from the body of the
       user. Warning statement to the user for keeping at least 20cm or more separation distance from the
       antenna should be included in the User manual. So, this device is classified as Mobile device.


       Note: ± 1 dB tune up value is considered for MPE calculation.
       Protocol: ZigBee.

Test Results

           Manufacturer has declared the tune-up value as ±1 dBm is considered in MPE calculation.

Antenna gain (G) : 3.27dBi = 2.12 (linear scale)


                         ZigBee             ZigBee            ZigBee             ZigBee
                                                                                                Sum
              Channel     (PBR-              (PBR-             (PBR-              (PBR-
             Frequency SZMDLNR1)          SZMDLNR1)        SZMDLM3BR1)        SZMDLM3BR1)
                           mW                 mW                 mW                 mW           mW
                2405       3.96               2.41              14.65              15.75        36.77
                2440       3.72               2.23              13.41              14.74        34.10
                2480       2.61               2.09              8.84               10.38        23.92
       Maxim um possible power value= 3.96 m W + 2.41 m W + 14.65 m W + 15.75 m W = 36.77 m W

                           Worst Case         Output Power        Power
                                             including tune-                     Limit
                          Output Power to                         Density
                                                 up (mW)                       (mW/cm²)
                          Antenna (mW)                           (mW/cm²)
                              36.7700            38.0289         0.016063        1.000



Document Created: 2019-08-06 17:52:20
Document Modified: 2019-08-06 17:52:20

© 2024 FCC.report