report

FCC ID: PAXPMV107M

Test Report

Download: PDF
FCCID_612872

A-014-05-C                                                                                                Page 1 of 18
                                                                                                FCC ID: PAXPMV107M




               KANSAI ELECTRONIC INDUSTRY DEVELOPMENT CENTER
                 HEAD OFFICE                                                         IKOMA TESTING LABORATORY
              6-8-7   NISHITENMA                                                        12128 TAKAYAMA-CHO
      KITA-KU OSAKA 530-0047 JAPAN                                                IKOMA-CITY NARA 630-0101 JAPAN
                                                Corporate Juridical Person

                                                  TEST REPORT
     Report No.A-014-05-C                                                                      Date: 4 October 2005

     This test report is to certify that the tested device properly complies with the requirements of:

                           FCC Rules and Regulations Part 15 Subpart C Intentional Radiators.

     All the tests necessary to show compliance to the requirements were performed and these results met the
     specifications of requirement. The results of this report should not be construed to imply compliance of
     equipment other than that, which was tested. Unless the laboratory permission, this report should not be
     copied in part.

     1. Applicant
          Company Name                : Pacific Industrial Co., Ltd. TPMS DEPT.

             Mailing Address          : Godo-cho, Ampachi, GIFU, 503-2397

     2. Identification of Tested Device
           Type of Device          : Transmitter
           Kind of Equipment Authorization :    : DoC      : Certification     : Verification
           FCC ID                  : PAXPMV107M
           Device Name             : Tire Pressure Monitoring System Transmitter
           Trade Name              : PACIFIC
           Model Number            : PMV-107M
           Serial Number           : No.1          : Production      : Pre-production       : Prototype
           Date of Manufacture     : September 2005

     3. Test Items and Procedure
              : AC Power Line Conducted Emission Measurement
              : Radiated Emission Measurement
              : Emission Bandwidth Measurement

             Above all tests were performed under: ANSI C63.4 – 2003
                       : without deviation,  : with deviation (details are found inside of this report)

     4. Date of Test
           Receipt of Test Sample : 27 September 2005
           Condition of Test Sample :   : Damage is not found on the set.
                                        : Damage is found on the set. (Details are described in this report)
           Test Completed on        : 30 September 2005




                                                                               Seiichi Izumi
                                                                  General Manager / Ikoma Testing Laboratory




                                         KEC Ikoma Testing Laboratory    12128 Takayama-cho Ikoma-city Nara 630-0101 Japan


A-014-05-C                                                                                                                                     Page 2 of 18
                                                                                                                                     FCC ID: PAXPMV107M




                                                                          Table of Contents




      0.      LABORATORY ACCREDITATION AND MEASUREMENT UNCERTAINTY .........................3
           0.1. Laboratory Accreditation................................................................................................................3
           0.2. Measurement Uncertainty ..............................................................................................................3
      1.      CERTIFICATION OF THE COMPLIANCE ...................................................................................3
      2.      GENERAL INFORMATION ..............................................................................................................4
           2.1. Product Description........................................................................................................................4
           2.2. Description for Equipment Authorization ......................................................................................5
           2.3. Test Facility ....................................................................................................................................5
      3.      TESTED SYSTEM...............................................................................................................................6
           3.1. Test Mode.......................................................................................................................................6
           3.2. Characteristics of transmitting train ...............................................................................................6
           3.3. Characterization and condition of EUT System .............................................................................8
      4.      RADIATED EMISSION MEASUREMENT .....................................................................................9
           4.1. Test Procedure ................................................................................................................................9
           4.2. Test Results ..................................................................................................................................10
      5.      EMISSION BANDWIDTH MEASUREMENT...............................................................................16
           5.1. Test Configuration........................................................................................................................16
           5.2. Test Results ..................................................................................................................................16
      6.      USED TEST EQUIPMENTS AND CALIBRATION STATUS......................................................18




                                                       KEC Ikoma Testing Laboratory                  12128 Takayama-cho Ikoma-city Nara 630-0101 Japan


A-014-05-C                                                                                               Page 3 of 18
                                                                                               FCC ID: PAXPMV107M



    0.     LABORATORY ACCREDITATION AND MEASUREMENT UNCERTAINTY

    0.1.    Laboratory Accreditation

             KEC is accredited by the National Voluntary Laboratory Accreditation Program (NVLAP) for the specific
             scope of accreditation under Lab Code: 200207-0.

             When the test report concerns with the NVLAP accreditation test, the first page of the test report is signed
             by NVLAP Approved Signatory accompanied by the NVLAP logo.

             The report must not be used by the client to claim product endorsement by NVLAP or any agency of the
             U.S. Government.



    0.2.    Measurement Uncertainty

             The result of a measurement is only an approximation or estimate of the value of a specific quantity.
             And thus the measured is complete only when a statement of uncertainty is given.
             KEC quotes Measurement Uncertainty (U)
                           of +/- 4.9dB for Radiated Emissions
                           of +/- 2.2dB for Conducted Emissions



    1.     CERTIFICATION OF THE COMPLIANCE

             This test report is to certify that the tested device properly complies with the requirements of FCC Rules
             and Regulations Part 15 Subpart C Intentional Radiators.




                                        KEC Ikoma Testing Laboratory    12128 Takayama-cho Ikoma-city Nara 630-0101 Japan


A-014-05-C                                                                                              Page 4 of 18
                                                                                              FCC ID: PAXPMV107M



    2.     GENERAL INFORMATION

    2.1.    Product Description

             The PACIFIC Model No.: PMV-107M (referred to as the EUT in this report) is a Tire Pressure Monitoring
             System Transmitter for cars.


              1) Technical Specifications
                  Operating frequency range       : 314.98MHz
                  Type of antenna                 : Internal Antenna
                  Type of Emission                : F2D (FSK)
                  Frequency deviation             : 40kHz (Nominal)

              2) Contained Oscillators
                  SAW                             : 314.68MHz

              3) Rated Power Supply               : DC3V (Lithium battery)




                                         KEC Ikoma Testing Laboratory   12128 Takayama-cho Ikoma-city Nara 630-0101 Japan


A-014-05-C                                                                                             Page 5 of 18
                                                                                             FCC ID: PAXPMV107M



    2.2.   Description for Equipment Authorization


     (1) Type of device                         :     Intentional Radiators

     (2) Reference Rule and Specification       : FCC Rule Part 15 Subpart C, Section 15.231 Periodic
                                                  operation in the band 40.66 – 40.70MHz and above 70MHz
                                                     Section 15.207
                                                     Section 15.209
                                                     Section 15.231 (c)
                                                     Section 15.231 (e)

     (3) Kind of Equipment Authorization        :     DoC         Certification        Verification

     (4) Procedure of Application               :     Original Equipment          Modification

     (5) Highest Frequency used in the Device : 314.98MHz

     (6) Upper Frequency of Radiated Emission Measurement Range
                                             :    1000MHz         2000MHz            5000MHz
                                                  Tenth harmonics of the highest fundamental frequency




    2.3.   Test Facility


     All tests described in this report were performed by:

             Name:         KANSAI ELECTRONIC INDUSTRY DEVELOPMENT CENTER (KEC)
                           IKOMA TESTING LABORATORY
                           Open Area Test Site       No.1         No.4
                           Anechoic Chamber          No.1         No.3
                           Shielded Room             No.1         No.2      No.4          No.6
             Address:      12128, Takayama-cho Ikoma-city, Nara, 630-0101 Japan

     These test facilities have been filed with the FCC under the criteria of ANSI C63.4-2003.
     The KEC has been accredited by the NVLAP (Lab. Code: 200207-0) based on ISO/IEC 17025.
     Also the laboratory has been authorized by TUV Product Service (GER) and TUV Rheinland (GER)
     based on their criteria for testing laboratory (ISO/IEC 17025).
     EMC M.C. Anechoic Chamber No.3 has been filed with the Industry Canada under the criteria of
     RSS212, issue 1. (File number : IC4149-3)




                                       KEC Ikoma Testing Laboratory    12128 Takayama-cho Ikoma-city Nara 630-0101 Japan


A-014-05-C                                                                                             Page 6 of 18
                                                                                             FCC ID: PAXPMV107M



    3.     TESTED SYSTEM

    3.1.    Test Mode

             Continuously transmitted mode.

             [Note]
               The EUT was operated continuously in measurement. In the measurement of radiated emission.
               The EUT was placed horizontally or vertically on the test table.
               The data of operation modes that produce the maximum emission were reported at each frequency.



    3.2.    Characteristics of transmitting train

             The transmission of EUT is less than 1.0 second and the intervals are greater than 10 seconds.
             See plot figure 1 to 4.




                                              Figure 1. normal transmission




                                       KEC Ikoma Testing Laboratory    12128 Takayama-cho Ikoma-city Nara 630-0101 Japan


A-014-05-C                                                                         Page 7 of 18
                                                                         FCC ID: PAXPMV107M



    - Continued -




                      Figure 2. Alert status transmission 1




                      Figure 3. Alert status transmission 1




                    KEC Ikoma Testing Laboratory   12128 Takayama-cho Ikoma-city Nara 630-0101 Japan


A-014-05-C                                                                                           Page 8 of 18
                                                                                           FCC ID: PAXPMV107M



    - Continued -




                                            Figure 4. Transmission interval


    [Note]
      (1) In figure 3, the duration of each transmission is not greater than one second.
      (2) In figure 4, the silent period between transmissions shall be at least 30 times the duration of the
           transmission but in no case less than 10 seconds.




    3.3.   Characterization and condition of EUT System

                : normal,    : not normal (that is                                         )




                                      KEC Ikoma Testing Laboratory   12128 Takayama-cho Ikoma-city Nara 630-0101 Japan


A-014-05-C                                                                                              Page 9 of 18
                                                                                              FCC ID: PAXPMV107M



    4.     RADIATED EMISSION MEASUREMENT

    4.1.    Test Procedure


     (1)     Configure the EUT System in accordance with ANSI C63.4-2003 section 8.
                   : without deviation,     : with deviation (details are found below)
             See also the block diagram and the photographs of EUT System configuration in this report.
     (2)     If the EUT system is connected to a public power network, all power cords for the EUT System are
             connected the receptacle on the turntable.
     (3)     Warm up the EUT System.
     (4)     Activate the EUT System and run the prepared software for the test, if necessary.
     (5)     To find out the emissions of the EUT System, preliminary radiated measurement are performed at a
             closer distance than that specified for final radiated measurement using the spectrum analyzer (*1) and
             the broad band antenna.
             In the frequency above 1GHz, it is performed using the spectrum analyzer (*2) and the horn antenna.
     (6)     To find out an EUT System condition, which produces the maximum emission, the configuration of
             EUT System, the position of the cables, and the operation mode, are changed under normal usage of
             the EUT.
     (7)     The spectrums are scanned from 30MHz to the upper frequency of measurement range, and collect
             the six highest emissions minimum on the spectrum analyzer relative to the limits in the whole range.
     (8)     In final compliance test, the six highest emissions minimum, recorded above, are measured at the
             specified distance using the broad band antenna or the tuned dipole antenna and the test receiver (*3).
             In the frequency above 1GHz, the measurements are performed by the horn antenna and
                          the test receiver (*4).
                          the spectrum analyzer (*2) with pre-amplifier.

     [Note]
     (*1)     Spectrum Analyzer Set Up Conditions
                Frequency range          : 30 – 1000MHz
                Resolution bandwidth     : 100kHz
                Detector function        : Peak mode
     (*2)     Spectrum Analyzer Set Up Conditions
                Frequency range          : 1GHz – Upper frequency of measurement range
                Resolution bandwidth     : 1MHz
                Video bandwidth          : 1MHz
                Attenuator               : 10dB
                Detector function        : Peak mode
     (*3)     Test Receiver Set Up Conditions
                Detector function        : Quasi – Peak or Peak
                IF bandwidth             : 120kHz
     (*4)     Test Receiver Set Up Conditions
                Detector function        : Average
                IF bandwidth             : 1MHz




                                        KEC Ikoma Testing Laboratory    12128 Takayama-cho Ikoma-city Nara 630-0101 Japan


A-014-05-C                                                                                             Page 10 of 18
                                                                                             FCC ID: PAXPMV107M



    4.2.   Test Results



                                                                       Measurement Distance        : 3m       : 10m
                    Antenna Conversion       Meter Reading        Maximum        Limit        Margin
       Measured
                     Factor    Factor    Horizontal    Vertical     Field    Peak    Average   for
       Frequency
                       (*1)      (*2)   Polarization Polarization Strength                    Limit
         (MHz)       (dB/m)      (dB)     (dBµV)       (dBµV)     (dBµV/m) (dBµV/m) (dBµV/m) (dB)
      [ Peak Detector Measurement ]
      [ Fundamental ]
            314.94        20.9        -         60.4         54.1       81.3   87.7      67.7      6.4

      [ Harmonics ]
           629.89         26.9           -         22.9         22.6           49.8       67.7       47.7       17.9
           945.00         31.3           -         11.7          9.0           43.0       67.7       47.7       24.7

      [ Average Detector Measurement ]
      [ Fundamental ]
           314.94        20.9      -16.7           60.4         54.1           64.6          -       67.7        3.1

      [ Harmonics ]
           629.89         26.9       -16.7         22.9         22.6           33.1          -       47.7       14.6
           945.00         31.3       -16.7         11.7          9.0           26.3          -       47.7       21.4


      [Note]
        The restrict band data below 1GHz, see the figure 5.
        30 – 1000MHz spectrum chart.




                                      KEC Ikoma Testing Laboratory     12128 Takayama-cho Ikoma-city Nara 630-0101 Japan


A-014-05-C                                                                                          Page 11 of 18
                                                                                          FCC ID: PAXPMV107M



    - Continued -



      Restricted Band Above 1GHz
       Measured Antenna Conversion         Meter Reading        Maximum        Limit        Margin
      Frequency Factor         Factor  Horizontal    Vertical     Field    Peak    Average   for
                       (*1)     (*2)  Polarization Polarization                             Limit
        ( MHz )     ( dB/m )    (dB)    (dBµV)       (dBµV)     (dBµV/m) (dBµV/m) (dBµV/m) ( dB )
      [ Peak Detector Measurement ]
      [ Harmonics ]
          1259.75        -12.6    -          64.2         61.7       51.6    74.0      54.0    22.4
          1574.76        -12.2    -          65.8         61.0       53.6    74.0      54.0    20.4
          1889.55        -10.7    -          60.2         55.5       49.5    74.0      54.0    24.5
          2204.06        -10.4    -          59.7         57.8       49.3    74.0      54.0    24.7
          2519.63         -9.9    -          53.4         49.4       43.5    74.0      54.0    30.5
          2834.57         -9.3    -          50.3         49.4       41.0    74.0      54.0    33.0
          3149.71         -8.6    -         <46.0        <46.0      <37.4    74.0      54.0  >36.6

      [ Average Detector Measurement ]
      [ Harmonics ]
         1259.75       -12.6                   64.2          61.7        51.6        -           54.0        2.4
         1574.76       -12.2      -16.7        65.8          61.0        36.9        -           54.0       17.1
         1889.55       -10.7      -16.7        60.2          55.5        32.8        -           54.0       21.2
         2204.06       -10.4      -16.7        59.7          57.8        32.6        -           54.0       21.4
         2519.63        -9.9      -16.7        53.4          49.4        26.8        -           54.0       27.2
         2834.57        -9.3      -16.7        50.3          49.4        24.3        -           54.0       29.7
         3149.71        -8.6      -16.7       <46.0         <46.0       <20.7        -           54.0      >33.3




                                    KEC Ikoma Testing Laboratory    12128 Takayama-cho Ikoma-city Nara 630-0101 Japan


A-014-05-C                                                                                            Page 12 of 18
                                                                                            FCC ID: PAXPMV107M



    Test data in Graph




                                       Figure 5. 30 – 1000MHz spectrum chart



    [Note]
      This spectrum chart is the result of Exploratory radiated emission measurement by using the spectrum analyzer.
      The result of Final radiated emission measurement is shown in the table of previous page.




                                      KEC Ikoma Testing Laboratory    12128 Takayama-cho Ikoma-city Nara 630-0101 Japan


A-014-05-C                                                                                           Page 13 of 18
                                                                                           FCC ID: PAXPMV107M



    - Continued -



         [Remark]
           (*1) : Antenna Factor includes the cable loss, above 1GHz, antenna factor includes
                  both of the cable loss and pre-amplifier gain.
           (*2) : Conversion Factor, See figure 6 and 7 (the picture of spectrum analyzer)
                  and See Page 14, Calculation of Conversion Factor (Peak detector to Average).
           (*3) : If the measurement value with the peak detector meets the average limits, the
                  measurement with average detector is omitted.
                  In FCC rule, the limit of measurement of radiated emission above 1GHz is regulated on the
                  average value. Therefore, the average value above 1GHz was determined by using a reduced
                  the video bandwidth of spectrum analyzer to obtain the average value in this case spectrum
                  analyzer set up condition.
                      Resolution Bandwidth   : 1MHz
                      Video Bandwidth        : 30Hz
                      Detector function      : Peak detector
         [Note]
           (1) * mark in Measured Frequency       : Measured with the tuned dipole antenna.
                No mark in Measured Frequency : Measured with the broadband antenna.
           (2) All emission not reported were less than 10dBµV at meter reading.

         [Calculation method]
             Maximum Field Strength (dBµV/m)
              = Meter Reading (at maximum level of Horizontal or Vertical) (dBµV) + Antenna Factor (dB/m)

         [Calculation of Limit (Average detector)]
           Fundamental
              L = 20log (16.667 × F – 2833.333) Where, L: Limit [dBµV/m], F: Frequency [MHz]
              L = 67.7 [dBµV/m] at F=314.95[MHz]

             Spurious Emission
               L = 67.7 – 20 = 47.7 [dBµV/m]
               Above 1000 MHz, the limit is replaced at 54 dBµV/m.


        [Environment]
             Temperature: 23 °C                  Humidity: 60 %


        [Tested Date / Tester]
          29 September 2005                      Signature
                                                                          Hironobu Matsuyama




                                      KEC Ikoma Testing Laboratory   12128 Takayama-cho Ikoma-city Nara 630-0101 Japan


A-014-05-C                                                                                            Page 14 of 18
                                                                                            FCC ID: PAXPMV107M



    - Continued -



     [Calculation of Conversion Factor (Peak detector to Average)]
        In accordance with ANSI C63.4-2003 section 13.1.4.2, The EUT's transmitting pulse modulated emissions,
        therefore the average level of emissions are found by measuring peak level of the emission and correcting
        them with the duty cycle.


       From Figure 6.
         The value of the sum of the pulse widths in one period   : 14.5 [msec]
         The length of the period                                 : 100.0 [msec]

          As the EUT pulse train exceeds 100ms, calculate the duty cycle by averaging the sum of the pulse widths
          over the width with the highest average value.


          Then, Conversion Factor PEAK to AVERAGE is calculated as follows.

          Conversion Factor                                                        14.5 [msec]
                                (dB) = 20 Log ( Duty cycle ) = 20 Log
        PEAK to AVERAGE                                                            100.0 [msec]
                                      = -16.7 (dB)
                                                                                                   n
                                   The value of the sum of the pulse widths in one period         ∑t
                                                                                                  n =1
                                                                                                         n
                    Duty cycle =
                                                      The length of period (T)



    [Sample Calculation at conversion Peak to Average]
        Field Strength (dBµV/m)
          = Meter Reading (at Maximum level of horizontal or vertical) (dBµV)
             + Antenna Factor (dB/m) + Conversion Factor (dB)




                                       KEC Ikoma Testing Laboratory   12128 Takayama-cho Ikoma-city Nara 630-0101 Japan


A-014-05-C                                                                         Page 15 of 18
                                                                         FCC ID: PAXPMV107M



    - Continued -




                                     Figure 6




                                     Figure 7




                    KEC Ikoma Testing Laboratory   12128 Takayama-cho Ikoma-city Nara 630-0101 Japan


A-014-05-C                                                                                             Page 16 of 18
                                                                                             FCC ID: PAXPMV107M



    5.     EMISSION BANDWIDTH MEASUREMENT

    5.1.    Test Configuration




                                             Receiving Antenna
                                                                       Spectrum
                                 EUT
                                                                       Analyzer




                                                                               GP- IB




                                                                       Recording

                                                                       Device(PC)




    5.2.    Test Results

               Measured emission bandwidth = 450kHz
               See next Figure 8 (the picture of spectrum analyzer)

           [Note]
             Emission Bandwidth was determined at the points 20dB down from the modulated carrier.
               Spectrum Analyzer Setting:
                                 Center Frequency         = 315.00MHz
                                 Frequency Span           = 200kHz/div.
                                 Resolution Bandwidth     = 100kHz
                                 Video Bandwidth          = 100kHz
                                 Sweep Time               = 5m sec
                                 Trace Mode               : MAX. HOLD


           [Environment]
              Temperature: 25°C                     Humidity: 54%

           [Calculation of Limit]
              Limit of Emission bandwidth = 315.00 MHz × 0.25% = 787.50kHz


           [Tested Date / Tester]
              30 September 2005                     Signature
                                                                            Hironobu Matsuyama




                                        KEC Ikoma Testing Laboratory   12128 Takayama-cho Ikoma-city Nara 630-0101 Japan


A-014-05-C                                                                         Page 17 of 18
                                                                         FCC ID: PAXPMV107M



    - Continued -




                                     Figure 8




                    KEC Ikoma Testing Laboratory   12128 Takayama-cho Ikoma-city Nara 630-0101 Japan


A-014-05-C                                                                                             Page 18 of 18
                                                                                             FCC ID: PAXPMV107M



    6.    USED TEST EQUIPMENTS AND CALIBRATION STATUS

                                                                                 KEC       Test
                                                                                                     Last      Next
         Equipment     Manufacturer      Model No.         Specifications       Control    Item
                                                                                                     Cal.      Cal.
                                                                                  No.       (*)
     Test              Rohde &         ESHS10           Frequency Range         FS-83       N/A    2005/2     2006/2
     Receiver          Schwarz                           9kHz – 30MHz
                                       ESVS10           Frequency Range         FS-66        2     2005/3     2006/3
                                                         20MHz – 1.0GHz
     Spectrum          Hewlett         8564E            Frequency Range         SA-39       2,3    2005/4     2006/4
     Analyzer          Packard                           30Hz – 40GHz
     Pre-amplifier     Hewlett         8449B            Frequency Range         AM-52        2     2005/2     2006/2
                       Packard                           1GHz – 26.5GHz
     Biconical         Schwarzbeck     BBA9106          Frequency Range         AN-180       2     2005/2     2006/2
     Antenna                                             30MHz – 300MHz
     Log-              Schwarzbeck     UHALP9108A       Frequency Range         AN-215       2     2005/2     2006/2
     Periodic                                            300MHz – 1GHz
     Antenna
     Tuned             Kyoritsu        KBA-511AS        Frequency Range         AN-135       2     2005/2     2007/2
     Dipole                                              25MHz – 500MHz
     Antenna                           KBA-611S         Frequency Range         AN-137       2     2005/2     2007/2
                                                         500MHz – 1GHz
     Horn              Raven           92888-2          Frequency Range         AN-211       2     2003/9     2005/9
     Antenna                                             1GHz – 2GHz
                                       91889-2          Frequency Range         AN-212       2     2003/9     2005/9
                                                         2GHz – 5GHz
     LISN              Kyoritsu        KNW-407          Frequency Range         FL-107      N/A    2005/7     2006/7
     for EUT                                             150kHz – 30MHz
     LISN for          Kyoritsu        KNW-242          Frequency Range         FL-110      N/A    2005/7     2006/7
     Peripheral                                          10kHz – 30MHz

     [Note]
              Test Item (*):      1: Conducted Emission Measurement
                                  2: Radiated Emission Measurement
                                  3: Bandwidth Measurement
                                  N/A: Not Applicable

     The overall program of calibration and verification of equipment is designed and operated so as to ensure
     that measurements made by KEC are traceable to national standards of measurement or equivalent abroad.




                                        KEC Ikoma Testing Laboratory   12128 Takayama-cho Ikoma-city Nara 630-0101 Japan



Document Created: 2005-10-11 15:59:57
Document Modified: 2005-10-11 15:59:57

© 2024 FCC.report