1. Introduction

In this document, we try to prove the safety of radiation harmfulness to the human body
for our product. The limit for Maximum Permissible Exposure (MPE) specified in FCC
1.1310 is followed. The Gain of the antenna used in this product is measured in a Fully
Anechoic Chamber (FAC) calibrated for antenna measurement in ADT, and also the
maximum total power input to the antenna is measured. Through the Friis transmission
formula and the maximum gain of the antenna, we can calculate the distance, away from
the product, where the limit of MPE is reached.
Although the Friis transmission formula is a far field assumption, the calculated result of
that is an over-prediction for near field power density. We will take that as the worst case
to specify the safety range.


2. RF Exposure Limit

According to FCC 1.1310: The criteria listed in the following table shall be used to
evaluate the environmental impact of human exposure to radio-frequency (RF) radiation
as specified in 1.1307(b)

LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE)

   Frequency        Electric Field    Magnetic Field    Power Density      Average Time
     Range         Strength (V/m)     Strength (A/m)      (mW/cm2)           (minutes)
     (MHz)
                   (A)Limits For Occupational / Control Exposures
   300-1500               …                 …                F/300                6
 1500-100,000             …                 …                  5                  6
             (B)Limits For General Population / Uncontrolled Exposure
   300-1500               …                 …               F/1500                6
 1500-100,000             …                 …                 1.0                30
F = Frequency in MHz




                                             2
Report No: SA950522L12


 FCC ID: PANBT333R




3. Friis Formula


Friis transmission formula: Pd = (Pout*G) / (4*pi*r2)


where
Pd = power density in mW/cm2
Pout = output power to antenna in mW
G = gain of antenna in linear scale
Pi = 3.1416
R = distance between observation point and center of the radiator in cm


If we know the maximum Gain of the antenna and the total power input to the antenna,
through the calculation, we will know the MPE value at distance 20cm.

Ref.: David K. Cheng, Field and Wave Electromagnetics, Second Edition,
      Page 640, Eq. (11-133).



4 EUT Operating condition
The software provided by Manufacturer enabled the EUT to transmit and receive data at
lowest, middle and highest channel individually.




                                             3
Report No: SA950522L12


 FCC ID: PANBT333R




5 Conclusion

No Evaluation Required if power is below this threshold:

               F(GHz)             mW
            Low 2.402
                                 24.58
            High 2.480

Maximum measured transmitter power:

                  Pout (dBm)              Pout (mW)
           Conducted Power   6.19           4.159
             EIRP Power      7.95           6.237
          *Note: The antenna is PCB antenna with 1.76dBi gain

     Threshold for no SAR evaluation is 24.58mW
     Transmitter power is 6.237mW

     Conclusion: No SAR evaluation required since Transmitter Pout is below FCC threshold