Test Report

FCC ID: PAGTR-026S

Test Report

Download: PDF
FCCID_3744222

                                             TEST REPORT
 Reference No.....................       : WTD18S0199520-1E

 FCC ID..............................    : PAGTR-026S

 Applicant..........................     : KAB Enterprise Co., Ltd.
                                             21F, -1, No.33, Sec. 1, Minsheng Rd., Banqiao Dist., New Taipei City
 Address............................     :
                                             220, Taiwan (R.O.C)
 Manufacturer....................        : Verdant Electronics(Dong Guan) Co., Ltd.
                                             Langxie Administrative District, Qiaotou, Dongguan City, Guang Dong
 Address............................     :
                                             Sheng, China
 Product..............................   : Remote Controller
 Model(s)........................        : TR-026S
 Standards.........................      : FCC CFR47 Part 15 Section 15.231:2017

 Date of Receipt sample....              : 2018-01-03

 Date of Test......................      : 2018-01-04 to 2018-01-18

 Date of Issue....................       : 2018-01-20
 Test Result.......................      : Pass


 Remarks:
 The results shown in this test report refer only to the sample(s) tested, this test report cannot be
 reproduced, except in full, without prior written permission of the company. The report would be invalid
 without specific stamp of test institute and the signatures of compiler and approver.

                                                Prepared By:
                                   Waltek Services (Shenzhen) Co., Ltd.
      Address: 1/F., Fukangtai Building, West Baima Road, Songgang Street, Baoan District, Shenzhen,
                                             Guangdong, China
                                          Test Site/Test Location:
                                   Waltek Services (Shenzhen) Co., Ltd.
      Address: 1/F., Fukangtai Building, West Baima Road, Songgang Street, Baoan District, Shenzhen,
                                             Guangdong, China
                                           Tel :+86-755-83551033
                                           Fax:+86-755-83552400

         Compiled by:                                                          Approved by:




         Robin Zhou /Test Engineer                                             Philo Zhong / Manager




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn                                      Page 1 of 20


Reference No.: WTD18S0199520-1E                         Page 2 of 20



1     Laboratories Introduction
     Waltek Services (Shenzhen) Co., Ltd is a professional third-party testing and certification
laboratory with multi-year product testing and certification experience, established strictly in accordance
with ISO/IEC 17025 requirements, and accredited by ILAC (International Laboratory Accreditation
Cooperation) member. A2LA (American Association for Laboratory Accreditation) of USA, Meanwhile,
Waltek has got recognition as registration and accreditation laboratory from EMSD (Electrical and
Mechanical Services Department), and American Energy star, FCC(The Federal Communications
Commission), CEC(California energy efficiency), IC(Industry Canada). It’s the strategic partner and data
recognition laboratory of international authoritative organizations, such as Intertek(ETL-SEMKO), TÜV
Rheinland, TÜV SÜD, etc.




     Waltek Services (Shenzhen) Co., Ltd is one of the largest and the most comprehensive third party
testing laboratory in China. Our test capability covered four large fields: safety test. Electro Magnetic
Compatibility (EMC), and energy performance, wireless radio. As a professional, comprehensive, justice
international test organization, we still keep the scientific and rigorous work attitude to help each client
satisfy the international standards and assist their product enter into globe market smoothly.




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTD18S0199520-1E                  Page 3 of 20




1.1 Test Facility
      A. Accreditations for Conformity Assessment (International)

      Country/Region       Accreditation Body          Scope                 Note
      USA                                              FCC ID \ DOC \ VOC    1
      Canada                                           IC ID \ VOC           2
      Japan                                            MIC-T \ MIC-R         -
                           A2LA
      Europe                                           EMCD \ RED            -
                           (Certificate No.: 4243.01)
      Taiwan                                           NCC                   -
      Hong Kong                                        OFCA                  -
      Australia                                        RCM                   -
      India                                            WPC                   -
      Thailand             International Services      NTC                   -
      Singapore                                        IDA                   -
      Note:
      1. FCC Designation No.: CN1201. Test Firm Registration No.: 523476.
      2. IC Canada Registration No.: 7760A

      A. TCBs and Notify Bodies Recognized Testing Laboratory.

      Recognized Testing Laboratory of …                Notify body number
      TUV Rheinland
      Intertek
                                                        Optional.
      TUV SUD
      SGS
      Phoenix Testlab GmbH                              0700
      Element Materials Technology Warwick Ltd          0891
      Timco Engineering, Inc.                           1177
      Eurofins Product Service GmbH                     0681




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTD18S0199520-1E                                                   Page 4 of 20



2     Contents
                                                                                                                                                              Page
     COVER PAGE ............................................................................................................................................ 1
1    LABORATORIES INTRODUCTION .............................................................................................................. 2
     1.1          TEST FACILITY ....................................................................................................................................... 3
2    CONTENTS ....................................................................................................................................................... 4
3    REPORT REVISION HISTORY ...................................................................................................................... 5
4    GENERAL INFORMATION ............................................................................................................................. 6
     4.1          GENERAL DESCRIPTION OF E.U.T........................................................................................................ 6
     4.2          DETAILS OF E.U.T. ................................................................................................................................ 6
     4.3          TEST MODE ........................................................................................................................................... 6
5    EQUIPMENT USED DURING TEST ............................................................................................................. 7
     5.1          EQUIPMENTS LIST ................................................................................................................................. 7
     5.2          MEASUREMENT UNCERTAINTY.............................................................................................................. 7
6    TEST SUMMARY ............................................................................................................................................. 8
7    RADIATED SPURIOUS EMISSIONS ............................................................................................................ 9
     7.1          EUT OPERATION ................................................................................................................................... 9
     7.2          TEST SETUP ........................................................................................................................................ 10
     7.3          SPECTRUM ANALYZER SETUP ............................................................................................................ 11
     7.4          TEST PROCEDURE ............................................................................................................................... 12
     7.5          SUMMARY OF TEST RESULTS ............................................................................................................. 13
8    PERIODIC OPERATION ............................................................................................................................... 14
9    EMISSION BANDWIDTH .............................................................................................................................. 18
     9.1          TEST PROCEDURE ............................................................................................................................... 18
     9.2          TEST RESULT ...................................................................................................................................... 18
10   ANTENNA REQUIREMENT ......................................................................................................................... 19
11   FCC ID: PAGTR-026S RF EXPOSURE REPORT .................................................................................... 20
12   PHOTOGRAPHS – MODEL TR-026S TEST SETUP PHOTOS ............................................................. 20
13   PHOTOGRAPHS - CONSTRUCTIONAL DETAILS ................................................................................. 20
     13.1         MODEL TR-026S - EXTERNAL PHOTOS ............................................................................................. 20
     13.2         MODEL TR-026S - INTERNAL PHOTOS .............................................................................................. 20




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTD18S0199520-1E                       Page 5 of 20



3       Report Revision History
                        Date of
                                                           Date of
    Test report No.     Receipt        Date of Test                   Purpose    Comment   Approved
                                                            Issue
                        sample

                                       2018-01-04 to
WTD18S0199520-1E      2018-01-03                         2018-01-20   original      -        Valid
                                        2018-01-18




 Waltek Services (Shenzhen) Co.,Ltd.
 http://www.waltek.com.cn


Reference No.: WTD18S0199520-1E                   Page 6 of 20



4     General Information
4.1 General Description of E.U.T.
      Product                     : Remote Controller
      Model(s)                    : TR-026S
      Model Difference            : N/A

      Type of Modulation          : ASK
      Frequency Range             : 433.92MHz
      Antenna installation        : PCB Printed Antenna

      Antenna Gain                : 0dBi

      Hardware Version            : REV.0

      Software Version            : REV.1


4.2 Details of E.U.T.

      Ratings:                    DC 12V, 23A by ALKALINE BATTERY


4.3 Test Mode
      All test mode(s) and condition(s) mentioned were considered and evaluated respectively by
      performing full tests, the worst data were recorded and reported.

                                   Test mode            Test channel
                                  Transmitting          433.92MHz




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


       Reference No.: WTD18S0199520-1E                     Page 7 of 20



       5       Equipment Used during Test
       5.1 Equipments List
3m Semi-anechoic Chamber for Radiation Emissions
                                                                                     Last Calibration Calibration Due
Item           Equipment            Manufacturer     Model No.      Serial No.
                                                                                           Date            Date
  1        Spectrum Analyzer            R&S            FSP30          100091             2017-04-29         2018-04-28
            Broad-band Horn
  2                                SCHWARZBECK      BBHA 9120 D           667            2017-04-09         2018-04-08
           Antenna(1-18GHz)
               Broadband            COMPLIANCE
  3                                                  PAP-1G18             2004           2017-04-13         2018-04-12
               Preamplifier          DIRECTION
              Coaxial Cable
  4                                     Top         1GHz-18GHz      EW02014-7            2017-04-13         2018-04-12
              (above 1GHz)
  5        Spectrum Analyzer            R&S            FSP40          100501             2017-10-20         2018-10-19
            Broad-band Horn                                        BBHA917065
  6                                SCHWARZBECK       BBHA 9170                           2017-10-25         2018-10-24
           Antenna(18-40GHz)                                           1
                Microwave
               Broadband
  7                                SCHWARZBECK        BBV 9721        100472             2017-10-25         2018-10-24
               Preamplifier
               (18-40GHz)
  8               Cable                 Top          18-40GHz               -            2017-10-25         2018-10-24
3m Semi-anechoic Chamber for Radiation Emissions
                                                                                       Last Calibration Calibration Due
Item           Equipment            Manufacturer     Model No.       Serial No
                                                                                             Date            Date
  1          Test Receiver              R&S             ESCI          101296             2017-04-13       2018-04-12
            Trilog Broadband
  2                                SCHWARZBECK       VULB9160       9160-3325            2017-04-13         2018-04-12
                 Antenna
  3        Active Loop Antenna      Beijing Dazhi    ZN30900A               -            2017-04-09         2018-04-08

  4             Amplifier             ANRITSU         MH648A          M43381             2017-04-13         2018-04-12

  5               Cable            HUBER+SUHNER         CBL2          525178             2017-04-13         2018-04-12
         Coaxial Cable
  6                                     Top         TYPE16(13M)             -            2017-09-12         2018-09-11
         (below 1GHz)
RF Conducted Testing
                                                                                       Last Calibration Calibration Due
Item           Equipment            Manufacturer     Model No.       Serial No.
                                                                                             Date            Date
  1        Spectrum Analyzer            R&S            FSP30          100091             2017-04-29       2018-04-28

       5.2 Measurement Uncertainty

                       Test Item              Frequency Range             Uncertainty              Note

                  Radiated Spurious            30MHz~1000MHz               5.03dB                    (1)
                     Emissions                 1000M~6000MHz               ± 5.47 dB                  (1)

              (1)This uncertainty represents an expanded uncertainty expressed at approximately the 95%
                confidence level using a coverage factor of k=2.


       Waltek Services (Shenzhen) Co.,Ltd.
       http://www.waltek.com.cn


Reference No.: WTD18S0199520-1E                 Page 8 of 20



6     Test Summary
                    Test Items                        Test Requirement                Result

              Conducted Emissions                           15.207                     N/A*
                                                           15.205(a)
           Radiated Spurious Emissions                      15.209                     Pass
                                                           15.231(a)

                Periodic Operation                         15.231(a)                  Pass

               Emission Bandwidth                          15.231(c)                  Pass

              Antenna Requirement                           15.203                    Pass

                  RF Exposure                            1.1307(b)(1)                 Pass
          Note: Pass=Compliance; NC=Not Compliance; NT=Not Tested; N/A=Not Applicable
      *: The EUT is only powered by battery, no need to evaluate AC Power Conducted Emission.




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTD18S0199520-1E                         Page 9 of 20



7     Radiated Spurious Emissions
      Test Requirement:                     FCC Part15 Paragraph 15.231(a), 15.209, 15.205
      Test Method:                          ANSI C63.10:2013
      Test Result:                          PASS
      Measurement Distance:                 3m
      Limit:
                                                                       Field Strength   Field Strength
          Fundamental         Field Strength        Field Strength
                                                                        of Spurious      of Spurious
           Frequency         of Fundamental        of Fundamental
                                                                         Emission         Emission
             (MHz)                (uV/m)              (dBuV/m)
                                                                           (uV/m)         (dBuV/m)
          44.66-40.70                2250                67                 225               47
               70-130                1250                62                 125               42
               130-174           1250 to 3750*       62 to 71.48*       125 to 375*      42 to 51.48*
               174-260               3750               71.48               375              51.48
               260-470       3750 to 12500*        71.48 to 81.94*     375 to 1250*     51.48 to 61.94*
           Above 470                12500               81.94              1250              61.94
       * linear interpolations

7.1 EUT Operation

     Operating Environment :
     Temperature:                       23.5 C
     Humidity:                          51.1 % RH
     Atmospheric Pressure:              101.2kPa
     EUT Operation :
     The test was performed in Transmitting mode, the test data were shown in the report.




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTD18S0199520-1E                   Page 10 of 20



7.2 Test Setup
      The radiated emission tests were performed in the 3m Semi- Anechoic Chamber test site, using the
      setup accordance with the ANSI C63.10:2013.

      The test setup for emission measurement below 30MHz.




              Semi-anechoic 3m Chamber
              Turn Table From 0°to 360°




                                                        3m
                              EUT


                            Turn Table
           0.8m




                                  PC              Spectrum            AMP          Combining
                                System            Analyzer                          Network



      The test setup for emission measurement from 30 MHz to 1 GHz.



              Semi-anechoic 3m Chamber
              Antenna Elevation Varies From 1 to 4 m
              Turn Table From 0°to 360°
                                                        3m


                              EUT


           0.8m             Turn Table




                                 PC              Spectrum             AMP         Combining
                               System            Analyzer                          Network




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTD18S0199520-1E                            Page 11 of 20




      The test setup for emission measurement above 1 GHz.




              Anechoic 3m Chamber
              Antenna Elevation Varies From 1 to 4 m
             Turn Table From 0°to 360°
                                                                   3m
                                EUT



           1.5m

                             Turn Table
                                                               Absorbers




                                   PC                     Spectrum                    AMP      Combining
                                 System                   Analyzer                              Network



7.3 Spectrum Analyzer Setup
          Below 30MHz
                         Sweep Speed .............................................. Auto
                         IF Bandwidth ................................................ 10kHz
                         Video Bandwidth.......................................... 10kHz
                         Resolution Bandwidth.................................. 10kHz
          30MHz ~ 1GHz
                         Sweep Speed .............................................. Auto
                         Detector ..................................................... PK
                         Resolution Bandwidth .................................. 100kHz
                         Video Bandwidth.......................................... 300kHz
          Above 1GHz
                         Sweep Speed .............................................. Auto
                         Detector ..................................................... PK
                         Resolution Bandwidth .................................. 1MHz
                         Video Bandwidth.......................................... 3MHz




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTD18S0199520-1E                      Page 12 of 20



7.4 Test Procedure

      1. The EUT is placed on a turntable. For below 1GHz, the EUT is 0.8m above ground plane;
      For above1GHz, the EUT is 1.5m above ground plane.
      2. The turntable shall be rotated for 360 degrees to determine the position of maximum emission
      level.
      3. EUT is set 3m away from the receiving antenna, which is moved from 1m to 4m to find out the
      maximum emissions. The spectrum was investigated from the lowest radio frequency signal
      generated in the device, without going below 9 kHz, up to the tenth harmonic of the highest
      fundamental frequency or to 40 GHz, whichever is lower.
      4. Maximum procedure was performed on the six highest emissions to ensure EUT compliance.
      5. And also, each emission was to be maximized by changing the polarization of receiving antenna
      both horizontal and vertical.
      6. Repeat above procedures until the measurements for all frequencies are complete.
      7. The radiation measurements are tested under 3-axes(X, Y, Z) position(X denotes lying on the
      table, Y denotes side stand and Z denotes vertical stand), After pre-test, It was found that the worse
      radiation emission was get at the X position. So the data shown was the X position only.




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTD18S0199520-1E                          Page 13 of 20



7.5 Summary of Test Results
      Test Frequency: 9 kHz~30 MHz

      The measurements were more than 20 dB below the limit and not reported.
      Test Frequency: 30MHz ~ 5GHz

                                        Test Channel: 433.92MHz
                                                                                            FCC Part
                Receiver     Turn         RX Antenna                       Corrected
                                                               Corrected                15.231/15.209/205
  Frequency     Reading      table                                         Amplitude
                                                                Factor
                 (PK)        Angle      Height      Polar                    (PK)        Limit      Margin

                                                                                        (dBμV/
     (MHz)       (dBμV)     Degree       (m)        (H/V)       (dB/m)     (dBμV/m)                  (dB)
                                                                                          m)

    433.92        93.43       106         1.1            H       -7.10      86.33       100.83      -14.50

    433.92        73.93       275         1.8            V       -7.10      66.83       100.83      -34.00

    867.84        36.61       233         2.0            H        1.19      37.80        80.83      -43.03

    867.84        42.32        42         1.2            V        1.19      43.51        80.83      -37.32

    1752.01       63.70       142         1.7            H       -13.94     49.76        74.00      -24.24

    1752.01       53.44       149         1.5            V       -13.94     39.50        74.00      -34.50

    4088.31       52.46       190         1.9            H       -7.41      45.05        74.00      -28.95

    4088.31       51.54       229         1.6            V       -7.41      44.13        74.00      -29.87

      AV = Peak +20Log10 (duty cycle) =PK+ (-10.56) [refer to section 8 for more detail]
                                                                             FCC Part 15.231/209/205
                                RX         Duty cycle         Calculated
   Frequency         PK
                              Antenna       Factor               AV
                                                                               Limit             Margin
                               Polar
     (MHz)       (dBμV/m)       (H/V)            (dB)          (dBμV/m)      (dBμV/m)             (dB)

     433.92        86.33            H           -10.56           75.77         80.83             -5.06

     433.92        66.83            V           -10.56           56.27         80.83             -24.56

     867.84        37.80            H           -10.56           27.24         60.83             -33.59

     867.84        43.51            V           -10.56           32.95         60.83             -27.88

    1752.01        49.76            H           -10.56           39.20         54.00             -14.80

    1752.01        39.50            V           -10.56           28.94         54.00             -25.06

    4088.31        45.05            H           -10.56           34.49         54.00             -19.51

    4088.31        44.13            V           -10.56           33.57         54.00             -20.43




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTD18S0199520-1E                       Page 14 of 20



8     Periodic Operation
      The duty cycle was determined by the following equation:
      To calculate the actual field intensity, The duty cycle correction factor in decibel is needed for later
      use and can be obtained from following conversion


      Duty Cycle(%)=Total On interval in a complete pulse train/ Length of a complete pulse train * %
      Duty Cycle Correction Factor(dB)=20 * Log10(Duty Cycle(%))


                  Total transmission time(ms)                 0.18*47+0.20*11*4+0.62*5*4=29.66

         Length of a complete transmission period(ms)                         100*

                        Duty Cycle(%)                                        29.66

               Duty Cycle Correction Factor(dB)                              -10.56

    (* Note: the transmitter operates for longer than 0.1 seconds, the measured field strength shall be
    determined from the average absolute voltage during a 0.1 second interval during which the field
    strength is at its maximum value. So the Length of a complete transmission period=100ms)
      Refer to the duty cycle plot (as below)




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTD18S0199520-1E       Page 15 of 20




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTD18S0199520-1E         Page 16 of 20



                                      Pulse 1




                                      Pulse 2




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTD18S0199520-1E                       Page 17 of 20



                                                  Pulse 3




FCC Part15.231 (a) (1) A manually operated transmitter shall employ a switch that will automatically
deactivate the transmitter within not more than 5 seconds of being released.
(2)A transmitter activated automatically shall cease transmission within 5 seconds after activation.




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTD18S0199520-1E                      Page 18 of 20



9     Emission Bandwidth
      Test Requirement:                 FCC Part15.231(c)
      Test Method:                      FCC Part15.231(c)
      Limit                             The bandwidth of the emission shall be no wider than 0.25% of the
                                        center frequency for devices operating above 70 MHz and below
                                        900 MHz. For devices operating above 900 MHz, the emission
                                         shall be no wider than 0.5% of the center frequency.

9.1 Test Procedure

      1. The transmitter output (antenna port) was connected to the spectrum analyzer.EUT and its
         simulators are placed on a table, let EUT working in test mode, then test it.
      2. The bandwidth of the fundamental frequency was measure by spectrum analyser with 10 kHz
        RBW and 30 kHz VBW. The 20 dB bandwidth was recorded.

9.2 Test Result
               Frequency      20dB Bandwidth               Limit
                                                                                   Result
                 (MHz)         Emission(KHz)               (KHz)
                433.92              55.95                1084.80                Compliance
              Limit=Center Frequency*0.25%
              Test Plot




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTD18S0199520-1E                     Page 19 of 20



10 Antenna Requirement
      An intentional radiator shall be designed to ensure that no antenna other than that furnished by the
      responsible party shall be used with the device. The use of a permanently attached antenna or of an
      antenna that uses a unique coupling to the intentional radiator shall be considered sufficient to
      comply with the provisions of this section. The manufacturer may design the unit so that a broken
      antenna can be replaced by the user, but the use of a standard antenna jack or electrical connector
      is prohibited. This requirement does not apply to carrier current devices or to devices operated
      under the provisions of §15.211, §15.213, §15.217, §15.219, or §15.221. Further, this requirement
      does not apply to intentional radiators that must be professionally installed, such as perimeter
      protection systems and some field disturbance sensors, or to other intentional radiators which, in
      accordance with §15.31(d), must be measured at the installation site. However, the installer shall be
      responsible for ensuring that the proper antenna is employed so that the limits in this part are not
      exceeded.

      For intentional device, according to FCC 47 CFR Section 15.203, an intentional radiator shall be
      designed to ensure that no antenna other than that furnished by the responsible party shall be used
      with the device.

      Result:
      The EUT has one PCB Printed Antenna, the gain is 0 dBi. meets the requirements of FCC 15.203.



                                                                          PCB Printed Antenna




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTD18S0199520-1E                   Page 20 of 20



11 FCC ID: PAGTR-026S RF Exposure Report
Note: Please refer to RF Exposure report: WTD18S0199520-2E.

12 Photographs – Model TR-026S Test Setup Photos
Note: Please refer to Photos: WTD18S0199520-3E.

13 Photographs - Constructional Details
13.1   Model TR-026S - External Photos

Note: Please refer to Photos: WTD18S0199520-3E.

13.2   Model TR-026S - Internal Photos

Note: Please refer to Photos: WTD18S0199520-3E.

                                      ======End of Report======