test report

FCC ID: PAGTR-026A

Test Report

Download: PDF
FCCID_4285969

                                               TEST REPORT
 Reference No.....................       : WTD19S04027070W

 FCC ID..............................    : PAGTR-026A

 Applicant..........................     : KAB Enterprise Co., Ltd.
 Address............................     : 21F, -1, No.33, Sec. 1, Minsheng Rd., Banqiao Dist., New Taipei City
                                           220, Taiwan
 Manufacturer....................        :
                                           Verdant Electronics(Dong Guan) Co., Ltd.
 Address............................     : Langxie Administrative District, Qiaotou, Dongguan City, Guang Dong
                                           Sheng, China
 Product..............................   : Remote Controller
 Model(s)........................        : TR-026A
 Standards.........................      : FCC CFR47 Part 15 Section 15.231:2019

 Date of Receipt sample....              : 2019-04-26

 Date of Test......................      : 2019-04-27 to 2019-05-15
 Date of Issue....................       : 2019-05-16

 Test Result.......................      : Pass


 Remarks:
 The results shown in this test report refer only to the sample(s) tested, this test report cannot be
 reproduced, except in full, without prior written permission of the company. The report would be invalid
 without specific stamp of test institute and the signatures of compiler and approver.

                                                Prepared By:
                                   Waltek Services (Shenzhen) Co., Ltd.
      Address: 1/F., Fukangtai Building, West Baima Road, Songgang Street, Baoan District, Shenzhen,
                                             Guangdong, China
                                          Test Site/Test Location:
                                   Waltek Services (Shenzhen) Co., Ltd.
      Address: 1/F., Fukangtai Building, West Baima Road, Songgang Street, Baoan District, Shenzhen,
                                             Guangdong, China
                                           Tel :+86-755-83551033
                                           Fax:+86-755-83552400

         Compiled by:                                                        Approved by:




         Robin Zhou /Test Engineer                                           Philo Zhong / Manager




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn                                     Page 1 of 27


Reference No.: WTD19S04027070W                          Page 2 of 27



1     Laboratories Introduction
Waltek Services (Shenzhen) Co., Ltd is a professional third-party testing and certification laboratory
with multi-year product testing and certification experience, established strictly in accordance with
ISO/IEC 17025 requirements, and accredited by ILAC (International Laboratory Accreditation Cooperation)
member. A2LA (American Association for Laboratory Accreditation, the certification number is 4243.01) of
USA, CNAS (China National Accreditation Service for Conformity Assessment, the registration number is
L3110) of China.Meanwhile, Waltek has got recognition as registration and accreditation laboratory from
EMSD (Electrical and Mechanical Services Department), and American Energy star, FCC(The Federal
Communications Commission), CEC(California energy efficiency), ISED (Innovation, Science and
Economic Development Canada). It’s the strategic partner and data recognition laboratory of international
authoritative organizations, such as Intertek(ETL-SEMKO), TÜV Rheinland, TÜV SÜD, etc.




Waltek Services (Shenzhen) Co., Ltd is one of the largest and the most comprehensive third party testing
laboratory in China. Our test capability covered four large fields: safety test. ElectroMagnetic
Compatibility(EMC), and energy performance, wireless radio. As a professional, comprehensive, justice
international test organization, we still keep the scientific and rigorous work attitude to help each client
satisfy the international standards and assist their product enter into globe market smoothly.




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTD19S04027070W                    Page 3 of 27


1.1    Test Facility
      A. Accreditations for Conformity Assessment (International)
      Country/Region        Scope Covered By             Scope                Note
      USA                                                FCC ID \ DOC \ VOC   1
      Canada                                             IC ID \ VOC          2
      Japan                                              MIC-T \ MIC-R        -
      Europe                                             EMCD \ RED           -
      Taiwan                                             NCC                  -
                            ISO/IEC 17025
      Hong Kong                                          OFCA                 -
      Australia                                          RCM                  -
      India                                              WPC                  -
      Thailand                                           NTC                  -
      Singapore                                          IDA                  -
      Note:
      1.   FCC Designation No.: CN1201. Test Firm Registration No.: 523476.
      2.   ISED CAB identifier: CN0013

      B.TCBs and Notify Bodies Recognized Testing Laboratory.


      Recognized Testing Laboratory of …                 Notify body number
      TUV Rheinland
      Intertek
                                                         Optional.
      TUV SUD
      SGS
      Phoenix Testlab GmbH                               0700
      Element Materials Technology Warwick Ltd.          0891
      Timco Engineering, Inc.                            1177
      Eurofins Product Service GmbH                      0681




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTD19S04027070W                Page 4 of 27



2     Contents
                                                             Page
1    LABORATORIES INTRODUCTION                                  2
     1.1    TEST FACILITY                                       3
2    CONTENTS                                                   4
3    REVISION HISTORY                                           5
4    GENERAL INFORMATION                                        6
     4.1    GENERAL DESCRIPTION OF E.U.T.                       6
     4.2    DETAILS OF E.U.T.                                   6
     4.3    TEST MODE                                           6
5    EQUIPMENT USED DURING TEST                                 7
     5.1    EQUIPMENTS LIST                                     7
     5.2    MEASUREMENT UNCERTAINTY                             8
     5.3    SUBCONTRACTED                                       8
6    TEST SUMMARY                                               9
7    RADIATED SPURIOUS EMISSIONS                               10
     7.1    EUT OPERATION                                      10
     7.2    TEST SETUP                                         11
     7.3    SPECTRUM ANALYZER SETUP                            12
     7.4    TEST PROCEDURE                                     13
     7.5    SUMMARY OF TEST RESULTS                            14
8    PERIODIC OPERATION                                        15
9    EMISSION BANDWIDTH                                        19
     9.1    TEST PROCEDURE                                     19
     9.2    TEST RESULT                                        19
10   ANTENNA REQUIREMENT                                       20
11   PHOTOGRAPHS – MODEL TR-026A TEST SETUP PHOTOS             21
12   PHOTOGRAPHS - CONSTRUCTIONAL DETAILS                      23
     12.1   MODEL TR-026A - EXTERNAL PHOTOS                    23
     12.2   MODEL TR-026A - INTERNAL PHOTOS                    26




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTD19S04027070W                        Page 5 of 27


3       Revision History
                        Date of
                                                           Date of
    Test report No.     Receipt        Date of Test                   Purpose    Comment   Approved
                                                            Issue
                        sample

                                       2019-04-27 to
WTD19S04027070W       2019-04-26                         2019-05-16   original      -        Valid
                                        2019-05-15




 Waltek Services (Shenzhen) Co.,Ltd.
 http://www.waltek.com.cn


Reference No.: WTD19S04027070W                    Page 6 of 27



4     General Information
4.1 General Description of E.U.T.
      Product:                    Remote Controller
      Model(s):                   TR-026A
      Model Difference:           N/A

      Type of Modulation:         PCM
      Frequency Range:            433.99MHz
      Antenna installation:       PCB Printed Antenna

      Antenna Gain:               0dBi


4.2 Details of E.U.T.
      Ratings:                    DC 3V by CR2032 LITHIUM BATTERY


4.3 Test Mode
      All test mode(s) and condition(s) mentioned were considered and evaluated respectively by
      performing full tests, the worst data were recorded and reported.

                                   Test mode            Test channel
                                  Transmitting          433.99MHz




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


       Reference No.: WTD19S04027070W                  Page 7 of 27



       5       Equipment Used during Test
       5.1 Equipments List
3m Semi-anechoic Chamber for Radiation Emissions
                                                                                 Last
                                                                                            Calibration
Item           Equipment          Manufacturer     Model No.     Serial No.   Calibration
                                                                                             Due Date
                                                                                 Date

  1        Spectrum Analyzer          R&S           FSP30         100091      2019-04-07    2020-04-06

            Broad-band Horn
  2                              SCHWARZBECK      BBHA 9120 D         667     2018-05-18    2019-05-17
           Antenna(1-18GHz)

               Broadband          COMPLIANCE
  3                                                PAP-1G18           2004    2019-04-07    2020-04-06
               Preamplifier        DIRECTION

              Coaxial Cable
  4                                   Top         1GHz-18GHz    EW02014-7     2019-04-07    2020-04-06
              (above 1GHz)

  5        Spectrum Analyzer          R&S           FSP40         100501      2018-10-20    2019-10-19

            Broad-band Horn                                     BBHA917065
  6                              SCHWARZBECK      BBHA 9170                   2018-10-25    2019-10-24
           Antenna(18-40GHz)                                        1
                Microwave
               Broadband
  7                              SCHWARZBECK       BBV 9721       100472      2018-10-25    2019-10-24
               Preamplifier
               (18-40GHz)
  8               Cable               Top          18-40GHz            -      2018-10-25    2019-10-24
3m Semi-anechoic Chamber for Radiation Emissions
                                                                                 Last
                                                                                            Calibration
Item           Equipment          Manufacturer     Model No.     Serial No    Calibration
                                                                                             Due Date
                                                                                 Date

  1           Test Receiver           R&S            ESCI         101296      2019-04-07    2020-04-06

            Trilog Broadband
  2                              SCHWARZBECK       VULB9160      9160-3325    2019-04-07    2020-04-06
                 Antenna

  3        Active Loop Antenna    Beijing Dazhi    ZN30900A            -      2019-04-07    2020-04-06

  4             Amplifier          ANRITSU          MH648A        M43381      2019-04-07    2020-04-06

  5               Cable          HUBER+SUHNER        CBL2         525178      2019-04-07    2020-04-06
              Coaxial Cable                         TYPE16                    2018-09-12    2019-09-11
  6                                   Top                              -
              (below 1GHz)                           (13M)




       Waltek Services (Shenzhen) Co.,Ltd.
       http://www.waltek.com.cn


        Reference No.: WTD19S04027070W                          Page 8 of 27


RF Conducted Testing
                                                                                          Last
                                                                                                     Calibration
 Item          Equipment            Manufacturer          Model No.       Serial No.   Calibration
                                                                                                      Due Date
                                                                                          Date

  1.      Spectrum Analyzer               R&S                FSL6          100959      2018-09-12    2019-09-11

  2           Coaxial Cable               Top            10Hz-30GHz            -       2018-09-12    2019-09-11

  3      Antenna Connector*             Realacc             45RSm              -       2018-09-12    2019-09-11

                                                         GDCB-3G-N-
  4             DC Block                Gwave                      140307001       2018-09-12     2019-09-11
                                                         SMA
“*”: The temporary antenna connector is soldered on the PCB board in order to perform conducted tests and this
temporary antenna connector is listed in the equipment list.

        5.2    Measurement Uncertainty

              Parameter                                  Uncertainty
              Radio Frequency                            ± 1 x 10-6
              RF Power                                   ± 1.0 dB
              RF Power Density                           ± 2.2 dB
                                                         ± 5.03 dB (30M~1000MHz)
              Radiated Spurious Emissions test
                                                         ± 5.47 dB (1000M~25000MHz)
              Confidence interval:95%. Confidence factor:k=2

        5.3 Subcontracted
               Whether parts of tests for the product have been subcontracted to other labs:

                  Yes              No
               If Yes, list the related test items and lab information:

               Test Lab: N/A
               Lab address: N/A
               Test items: N/A




         Waltek Services (Shenzhen) Co.,Ltd.
         http://www.waltek.com.cn


Reference No.: WTD19S04027070W                  Page 9 of 27



6     Test Summary
                    Test Items                        Test Requirement                Result

              Conducted Emissions                           15.207                     N/A*
                                                           15.205(a)
           Radiated Spurious Emissions                      15.209                     Pass
                                                           15.231(a)

                Periodic Operation                         15.231(a)                  Pass

               Emission Bandwidth                          15.231(c)                  Pass

              Antenna Requirement                           15.203                    Pass
          Note: Pass=Compliance; NC=Not Compliance; NT=Not Tested; N/A=Not Applicable
      *: The EUT is only powered by battery, no need to evaluate AC Power Conducted Emission.




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTD19S04027070W                          Page 10 of 27



7     Radiated Spurious Emissions
      Test Requirement:                     FCC Part15 Paragraph 15.231(a), 15.209, 15.205
      Test Method:                          ANSI C63.10:2013
      Test Result:                          PASS
      Measurement Distance:                 3m
      Limit:
                                                                     Field Strength    Field Strength
          Fundamental         Field Strength        Field Strength
                                                                      of Spurious       of Spurious
           Frequency         of Fundamental        of Fundamental
                                                                       Emission          Emission
             (MHz)                (uV/m)              (dBuV/m)
                                                                         (uV/m)          (dBuV/m)
          44.66-40.70                2250                67                 225               47
               70-130                1250                62                 125               42
               130-174           1250 to 3750*       62 to 71.48*       125 to 375*     42 to 51.48*
               174-260               3750               71.48               375              51.48
               260-470       3750 to 12500*        71.48 to 81.94*      375 to 1250*   51.48 to 61.94*
           Above 470                12500               81.94              1250              61.94
       * linear interpolations

7.1 EUT Operation

     Operating Environment :
     Temperature:                       23.5 C
     Humidity:                          54.6% RH
     Atmospheric Pressure:              101.7kPa

     Test Voltage:                      DC 3V by Battery
     EUT Operation :
     The test was performed in Transmitting mode, the test data were shown in the report.




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTD19S04027070W                    Page 11 of 27



7.2 Test Setup
      The radiated emission tests were performed in the 3m Semi- Anechoic Chamber test site, using the
      setup accordance with the ANSI C63.10:2013.

      The test setup for emission measurement below 30MHz.




              Semi-anechoic 3m Chamber
              Turn Table From 0°to 360°




                                                        3m
                              EUT


                            Turn Table
           0.8m




                                  PC              Spectrum            AMP          Combining
                                System            Analyzer                          Network



      The test setup for emission measurement from 30 MHz to 1 GHz.



              Semi-anechoic 3m Chamber
              Antenna Elevation Varies From 1 to 4 m
              Turn Table From 0°to 360°
                                                        3m


                              EUT


           0.8m             Turn Table




                                 PC              Spectrum             AMP         Combining
                               System            Analyzer                          Network




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTD19S04027070W                             Page 12 of 27




      The test setup for emission measurement above 1 GHz.




              Anechoic 3m Chamber
              Antenna Elevation Varies From 1 to 4 m
             Turn Table From 0°to 360°
                                                                   3m
                                EUT



           1.5m

                             Turn Table
                                                               Absorbers




                                   PC                     Spectrum                    AMP      Combining
                                 System                   Analyzer                              Network



7.3 Spectrum Analyzer Setup
          Below 30MHz
                         Sweep Speed .............................................. Auto
                         IF Bandwidth ................................................ 10kHz
                         Video Bandwidth.......................................... 10kHz

                         Resolution Bandwidth.................................. 10kHz
          30MHz ~ 1GHz
                         Sweep Speed .............................................. Auto
                         Detector ..................................................... PK
                         Resolution Bandwidth .................................. 100kHz
                         Video Bandwidth.......................................... 300kHz

          Above 1GHz
                         Sweep Speed .............................................. Auto
                         Detector ..................................................... PK
                         Resolution Bandwidth .................................. 1MHz
                         Video Bandwidth.......................................... 3MHz




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTD19S04027070W                       Page 13 of 27



7.4 Test Procedure

      1. The EUT is placed on a turntable. For below 1GHz, the EUT is 0.8m above ground plane;
      For above1GHz, the EUT is 1.5m above ground plane.
      2. The turntable shall be rotated for 360 degrees to determine the position of maximum emission
      level.
      3. EUT is set 3m away from the receiving antenna, which is moved from 1m to 4m to find out the
      maximum emissions. The spectrum was investigated from the lowest radio frequency signal
      generated in the device, without going below 9 kHz, up to the tenth harmonic of the highest
      fundamental frequency or to 40 GHz, whichever is lower.
      4. Maximum procedure was performed on the six highest emissions to ensure EUT compliance.
      5. And also, each emission was to be maximized by changing the polarization of receiving antenna
      both horizontal and vertical.
      6. Repeat above procedures until the measurements for all frequencies are complete.
      7. The radiation measurements are tested under 3-axes(X, Y, Z) position(X denotes lying on the
      table, Y denotes side stand and Z denotes vertical stand), After pre-test, It was found that the worse
      radiation emission was get at the X position. So the data shown was the X position only.




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTD19S04027070W                           Page 14 of 27



7.5 Summary of Test Results
      Test Frequency: 9 kHz~30 MHz

      The measurements were more than 20 dB below the limit and not reported.
      Test Frequency: 30 MHz ~ 5 GHz

                                        Test Channel: 433.99MHz
                                                                                            FCC Part
                Receiver     Turn         RX Antenna                       Corrected
                                                               Corrected                15.231/15.209/205
  Frequency     Reading      table                                         Amplitude
                                                                Factor
                 (PK)        Angle      Height      Polar                    (PK)        Limit      Margin

                                                                                        (dBμV/
     (MHz)       (dBμV)     Degree       (m)        (H/V)       (dB/m)     (dBμV/m)                  (dB)
                                                                                          m)

    433.99        85.41       310         1.8            H       -7.08      78.33       100.83      -22.50

    433.99        67.68       247         1.5            V       -7.08      60.60       100.83      -40.23

    867.98        32.80       187         1.9            H        2.63      35.43        80.83      -45.40

    867.98        31.47       146         1.1            V        2.63      34.10        80.83      -46.73

    1300.63       61.12       195         1.5            H       -14.89     46.23        74.00      -27.77

    1300.63       56.87       347         1.3            V       -14.89     41.98        74.00      -32.02

    1750.04       51.65        76         1.9            H       -13.16     38.49        74.00      -35.51

    1750.04       61.96        39         1.4            V       -13.16     48.80        74.00      -25.20

      AV = Peak +20Log10 (duty cycle) =PK+ (-11.79) [refer to section 8 for more detail]
                                                                             FCC Part 15.231/209/205
                                RX         Duty cycle         Calculated
   Frequency         PK
                              Antenna       Factor               AV
                                                                               Limit             Margin
                               Polar
     (MHz)       (dBμV/m)       (H/V)            (dB)          (dBμV/m)      (dBμV/m)             (dB)

     433.99        78.33            H           -11.79           66.54         80.83             -14.29

     433.99        60.60            V           -11.79           48.81         80.83             -32.02

     867.98        35.43            H           -11.79           23.64         60.83             -37.19

     867.98        34.10            V           -11.79           22.31         60.83             -38.52

    1300.63        46.23            H           -11.79           34.44         54.00             -19.56

    1300.63        41.98            V           -11.79           30.19         54.00             -23.81

    1750.04        38.49            H           -11.79           26.70         54.00             -27.30

    1750.04        48.80            V           -11.79           37.01         54.00             -16.99




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTD19S04027070W                        Page 15 of 27



8     Periodic Operation
      The duty cycle was determined by the following equation:
      To calculate the actual field intensity, The duty cycle correction factor in decibel is needed for later
      use and can be obtained from following conversion


      Duty Cycle(%)=Total On interval in a complete pulse train/ Length of a complete pulse train * %
      Duty Cycle Correction Factor(dB)=20 * Log10(Duty Cycle(%))


                Total transmission time(ms)               0.18*47+(0.18*12+0.54*4)*4=25.74

        Length of a complete transmission period(ms)                        100.00*

                       Duty Cycle(%)                                         25.74

              Duty Cycle Correction Factor(dB)                               -11.79

    (* Note: the transmitter operates for longer than 0.1 seconds, the measured field strength shall be
    determined from the average absolute voltage during a 0.1 second interval during which the field
    strength is at its maximum value. So the Length of a complete transmission period=100ms)
      Refer to the duty cycle plot (as below)




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTD19S04027070W        Page 16 of 27




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTD19S04027070W          Page 17 of 27



                                      Pulse 1




                                      Pulse 2




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTD19S04027070W                        Page 18 of 27



                                                  Pulse 3




FCC Part15.231 (a) (1) A manually operated transmitter shall employ a switch that will automatically
deactivate the transmitter within not more than 5 seconds of being released.
(2)A transmitter activated automatically shall cease transmission within 5 seconds after activation.




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTD19S04027070W                       Page 19 of 27



9     Emission Bandwidth
      Test Requirement:                 FCC Part15.231(c)
      Test Method:                      FCC Part15.231(c)
      Limit                             The bandwidth of the emission shall be no wider than 0.25% of the
                                        center frequency for devices operating above 70 MHz and below
                                        900 MHz. For devices operating above 900 MHz, the emission
                                         shall be no wider than 0.5% of the center frequency.

9.1 Test Procedure

      1. The transmitter output (antenna port) was connected to the spectrum analyzer.EUT and its
         simulators are placed on a table, let EUT working in test mode, then test it.
      2. The bandwidth of the fundamental frequency was measure by spectrum analyser with 10 kHz
        RBW and 30 kHz VBW. The 20 dB bandwidth was recorded.

9.2 Test Result
     Frequency        20dB Bandwidth        99% Bandwidth                Limit
                                                                                           Result
       (MHz)           Emission(kHz)        Emission(kHz)                (kHz)
      433.99               53.40                 138.00                1084.98           Compliance
              Limit=Center Frequency*0.25%
              Test Plot




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTD19S04027070W                      Page 20 of 27



10 Antenna Requirement
      An intentional radiator shall be designed to ensure that no antenna other than that furnished by the
      responsible party shall be used with the device. The use of a permanently attached antenna or of an
      antenna that uses a unique coupling to the intentional radiator shall be considered sufficient to
      comply with the provisions of this section. The manufacturer may design the unit so that a broken
      antenna can be replaced by the user, but the use of a standard antenna jack or electrical connector
      is prohibited. This requirement does not apply to carrier current devices or to devices operated
      under the provisions of §15.211, §15.213, §15.217, §15.219, or §15.221. Further, this requirement
      does not apply to intentional radiators that must be professionally installed, such as perimeter
      protection systems and some field disturbance sensors, or to other intentional radiators which, in
      accordance with §15.31(d), must be measured at the installation site. However, the installer shall be
      responsible for ensuring that the proper antenna is employed so that the limits in this part are not
      exceeded.

      For intentional device, according to FCC 47 CFR Section 15.203, an intentional radiator shall be
      designed to ensure that no antenna other than that furnished by the responsible party shall be used
      with the device.

      Result:
      The EUT has one PCB Printed Antenna, the gain is 0 dBi. meets the requirements of FCC 15.203.



                                                                      PCB Printed Antenna




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTD19S04027070W                Page 21 of 27



11 Photographs – Model TR-026A Test Setup Photos
                                         Below 30MHz




                                      From 30MHz to 1GHz




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTD19S04027070W            Page 22 of 27



                                      Above 1GHz




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTD19S04027070W           Page 23 of 27


12 Photographs - Constructional Details
12.1   Model TR-026A - External Photos




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTD19S04027070W        Page 24 of 27




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTD19S04027070W        Page 25 of 27




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTD19S04027070W           Page 26 of 27


12.2   Model TR-026A - Internal Photos




                                                     PCB Printed Antenna




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTD19S04027070W                   Page 27 of 27




                                      ======End of Report======




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn



Document Created: 2019-05-21 10:07:36
Document Modified: 2019-05-21 10:07:36

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC