FCC TEST REPORT                                                                              Report No.: FR922534




                            FCC RADIO TEST REPORT

                                                 according to


                            47 CFR FCC Part 15 Subpart C § 15.231


         Equipment                : Remote Control
         Model No.                : TR-011
         Brand Name               : KAB
         Filing Type              : New Application
         Applicant                : KAB Enterprise Co., Ltd.
                                    21F-1, No. 33, Sec. 1, Ming Sheng Rd. Panchiao, Taipei
                                    Hsien, Taiwan, R.O.C.
         FCC ID                   : PAGTR-011
         Manufacturer             : Verdant Electronics (Dong Guan) Co., Ltd.
                                    Langxie Administrative District, Qiaotou Dongguan City,
                                    Guangdog China
         Received Date            : Feb. 26, 2009
         Final Test Date          : Feb. 27, 2009



  Statement
 The test result in this report refers exclusively to the presented test model / sample.
 Without written approval of SPORTON International Inc., the test report shall not be reproduced except in full.
 The measurements and test results shown in this test report were made in accordance with the procedures and
 found in compliance with the limit given in ANSI C63.4-2003 and 47 CFR FCC Part 15 Subpart C.
 The test equipment used to perform the test is calibrated and traceable to NML/ROC.




                                      SPORTON International Inc.

          6F, No. 106, Sec. 1, Hsin Tai Wu Rd., Hsi Chih, Taipei Hsien, Taiwan, R.O.C.


                                                                                           SPORTON International Inc.
                                                                                              Report Format Version: a


FCC TEST REPORT                                                                                                                                                                  Report No.: FR922534

                                                                                   Table of Contents
1. SUMMARY OF THE TEST RESULT ...................................................................................................................... 2
2. GENERAL INFORMATION..................................................................................................................................... 3
    2.1      Product Details ............................................................................................................................................................................................. 3
    2.2      Table for Carrier Frequencies ...................................................................................................................................................................... 3
    2.3      Table for Test Modes ................................................................................................................................................................................... 3
    2.4      Table for Testing Locations.......................................................................................................................................................................... 3
    2.5      Table for Supporting Units ........................................................................................................................................................................... 4
    2.6      Test Configurations ...................................................................................................................................................................................... 4

3. TEST RESULT ........................................................................................................................................................ 5
    3.1      AC Power Line Conducted Emissions Measurement ................................................................................................................................. 5
    3.2      Field Strength of Fundamental Emissions Measurement ........................................................................................................................... 8
    3.3      20dB Spectrum Bandwidth Measurement ................................................................................................................................................. 11
    3.4      Deactivating Time....................................................................................................................................................................................... 13
    3.5      Radiated Emissions Measurement ............................................................................................................................................................ 16
    3.6      Antenna Requirements............................................................................................................................................................................... 24

4. LIST OF MEASURING EQUIPMENTS ................................................................................................................. 25
5. TEST LOCATION.................................................................................................................................................. 26
6. TAF CERTIFICATE OF ACCREDITATION .......................................................................................................... 27
APPENDIX A. TEST PHOTOS ........................................................................................................................ A1 ~ A4
APPENDIX B. PHOTOGRAPHS OF EUT ....................................................................................................... B1 ~ B3




SPORTON International Inc.                                                                                                                                               Page No.               : i of ii
TEL : 886-2-2696-2468                                                                                                                                                    Issued Date            : Mar. 05, 2009
FAX : 886-2-2696-2255                                                                                                                                                    FCC ID                 : PAGTR-011


FCC TEST REPORT                                                                                 Report No.: FR922534



                                      History of This Test Report

      Original Issue Date: Mar. 05, 2009
      Report No.: FR922534
      ■ No additional attachment.
      □ Additional attachment were issued as following record:

        Attachment No.              Issue Date        Description

                                                      15.205(a) 15.209(a)

                                                      15.231(a) 15.231(e)




      Further, this requirement does not apply to intentional radiators that must be professionally installed.




SPORTON International Inc.                                                                 Page No.      : ii of ii
TEL : 886-2-2696-2468                                                                      Issued Date   : Mar. 05, 2009
FAX : 886-2-2696-2255                                                                      FCC ID        : PAGTR-011


FCC TEST REPORT                                                                              Report No.: FR922534




                 CERTIFICATE OF COMPLIANCE
                                                 according to


                             47 CFR FCC Part 15 Subpart C § 15.231


                  Equipment           : Remote Control
                  Model No.           : TR-011
                  Brand Name          : KAB
                  Applicant           : KAB Enterprise Co., Ltd.
                                        21F-1, No. 33, Sec. 1, Ming Sheng Rd. Panchiao,
                                        Taipei Hsien, Taiwan, R.O.C.



     Sporton International as requested by the applicant to evaluate the EMC performance of the product sample
     received on Feb. 26, 2009 would like to declare that the tested sample has been evaluated and found to be in
     compliance with the tested rule parts. The data recorded as well as the test configuration specified is true and
     accurate for showing the sample’s EMC nature.




     ____________________________
     Sam Lee / Supervisor
     Reviewed Data: Dec. 31, 2005




                                     SPORTON International Inc.
                6F, No.106, Sec. 1, Hsin Tai Wu Rd., Hsi Chih, Taipei Hsien, Taiwan, R.O.C.



SPORTON International Inc.                                                               Page No.      : 1 of 27
TEL : 886-2-2696-2468                                                                    Issued Date   : Mar. 05, 2009
FAX : 886-2-2696-2255                                                                    FCC ID        : PAGTR-011


FCC TEST REPORT                                                                          Report No.: FR922534


1. SUMMARY OF THE TEST RESULT


                                 Applied Standard: 47 CFR FCC Part 15 Subpart C
       Part       Rule Section                  Description of Test                Result        Under Limit
        3.1     15.207           AC Power Line Conducted Emissions                   -                  -
        3.2     15.231(b)        Field Strength of Fundamental Emissions          Complies          8.30 dB
        3.3     15.231(c)        20dB Spectrum Bandwidth                          Complies              -
        3.4     15.231(a)        Deactivating time                                Complies              -
        3.5     15.231(b)        Radiated Emissions                               Complies          6.81 dB
        3.6     15.231(b)        Band Edge Emissions                              Complies              -
        3.7     15.203           Antenna Requirements                             Complies              -


                             Test Items                           Uncertainty               Remark
      AC Power Line Conducted Emissions                          ±2.26dB        Confidence levels of 95%
      Field Strength of Fundamental Emissions                    ±3.72dB        Confidence levels of 95%
      20dB Spectrum Bandwidth                                    ±6.25×10-7     Confidence levels of 95%
      Radiated Emissions/ Band Edge Emissions                    ±3.72dB        Confidence levels of 95%




SPORTON International Inc.                                                         Page No.      : 2 of 27
TEL : 886-2-2696-2468                                                              Issued Date   : Mar. 05, 2009
FAX : 886-2-2696-2255                                                              FCC ID        : PAGTR-011


FCC TEST REPORT                                                                                    Report No.: FR922534


2. GENERAL INFORMATION
2.1 Product Details

                        Items                                                Description
        Power Type                             DC 12V Battery
        Modulation                             ASK
        Frequency Range                        314.91MHz
        Channel Number                         1
        Channel Band Width (99%)               90 kHz
        Max. Fundamental Field Strength        67.45 dBuV/m at 3m (Peak)
        Antenna                                Integrated Antenna

2.2 Table for Carrier Frequencies

            Freqeuncy Band                         Channel No.                                 Frequency
               314.91MHz                                1                                      314.91 MHz

2.3 Table for Test Modes

      The following table is a list of the test modes shown in this test report.
                                Test Items                                   Mode                         Channel
        AC Power Line Conducted Emissions                        N/A                              N/A
        Field Strength of Fundamental Emissions                  CTX                              1
        20dB Spectrum Bandwidth
        Deactivating Time                                        Normal Use                       1
        Radiated Emissions 9kHz~30MHz                            CTX                              1
        Radiated Emissions 9kHz~10th Harmonic
        Band Edge Emissions
      Note: CTX=continuously transmitting

2.4 Table for Testing Locations

         Test Site No.       Site Category         Location      FCC Reg. No.        IC File No.             VCCI Reg. No
         03CH02-HY                SAC              Hwa Ya            101377           IC 4088                       -
           TH01-HY           OVEN Room             Hwa Ya                -                 -                        -
      Open Area Test Site (OATS); Semi Anechoic Chamber (SAC); Fully Anechoic Chamber (FAC).




SPORTON International Inc.                                                                     Page No.       : 3 of 27
TEL : 886-2-2696-2468                                                                          Issued Date    : Mar. 05, 2009
FAX : 886-2-2696-2255                                                                          FCC ID         : PAGTR-011


FCC TEST REPORT                                         Report No.: FR922534


2.5 Table for Supporting Units

        The EUT was tested alone.

2.6 Test Configurations

2.6.1    Radiation Emissions Test Configuration
        For radiated emissions 9kHz~1GHz



                                            EUT




        For radiated emissions above 1GHz




                                              EUT




SPORTON International Inc.                          Page No.      : 4 of 27
TEL : 886-2-2696-2468                               Issued Date   : Mar. 05, 2009
FAX : 886-2-2696-2255                               FCC ID        : PAGTR-011


FCC TEST REPORT                                                                                    Report No.: FR922534


3. TEST RESULT
3.1 AC Power Line Conducted Emissions Measurement

3.1.1   Limit
         For a Low-power Radio-frequency Device which is designed to be connected to the AC power line, the radio
         frequency voltage that is conducted back onto the AC power line on any frequency or frequencies within the
         band 150 kHz to 30 MHz shall not exceed below limits table.
                   Frequency (MHz)                        QP Limit (dBuV)                      AV Limit (dBuV)
                        0.15~0.5                               66~56                                 56~46
                         0.5~5                                   56                                       46
                         5~30                                    60                                       50

3.1.2   Measuring Instruments and Setting
         Please refer to section 4 of equipments list in this report.The following table is the setting of the receiver.
          Receiver Parameters          Setting
          Attenuation                  10 dB
          Start Frequency              0.15 MHz
          Stop Frequency               30 MHz
          IF Bandwidth                 9 KHz

3.1.3   Test Procedures
         1.   Configure the EUT according to ANSI C63.4. The EUT or host of EUT has to be placed 0.4 meter far
              from the conducting wall of the shielding room and at least 80 centimeters from any other grounded
              conducting surface.
         2.   Connect EUT or host of EUT to the power mains through a line impedance stabilization network (LISN).
         3.   All the support units are connected to the other LISNs. The LISN should provide 50uH/50ohms coupling
              impedance.
         4.   The frequency range from 150 KHz to 30 MHz was searched.
         5.   Set the test-receiver system to Peak Detect Function and Specified Bandwidth with Maximum Hold
              Mode.
         6.   The measurement has to be done between each power line and ground at the power terminal.




SPORTON International Inc.                                                                     Page No.        : 5 of 27
TEL : 886-2-2696-2468                                                                          Issued Date     : Mar. 05, 2009
FAX : 886-2-2696-2255                                                                          FCC ID          : PAGTR-011


FCC TEST REPORT                                                                                 Report No.: FR922534


3.1.4   Test Setup Layout




        1.   Interconnecting cables that hang closer than 40 cm to the ground plane shall be folded back and forth in
             the center forming a bundle 30 to 40 cm long.
        2.   I/O cables that are not connected to a peripheral shall be bundled in the center. The end of the cable
             may be terminated, if required, using the correct terminating impedance. The overall length shall not
             exceed 1 m.
        3.   EUT connected to one LISN. Unused LISN measuring port connectors shall be terminated in 50 Ω. LISN
             can be placed on top of, or immediately beneath, reference ground plane.
             3.1 All other equipment powered from additional LISN(s).
             3.2 Multiple outlet strip can be used for multiple power cords of non-EUT equipment.
             3.3 LISN at least 80cm from nearest part of EUT chassis.
        4.   Cables of hand-operated devices, such as keyboards, mice, etc., shall be placed as for normal use.
        5.   Non-EUT components of EUT system being tested.
        6.   Rear of EUT, including peripherals, shall all be aligned and flush with rear of tabletop.
        7.   Rear of tabletop shall be 40 cm removed from a vertical conducting plane that is bonded to the ground
             plane.




SPORTON International Inc.                                                                  Page No.      : 6 of 27
TEL : 886-2-2696-2468                                                                       Issued Date   : Mar. 05, 2009
FAX : 886-2-2696-2255                                                                       FCC ID        : PAGTR-011


FCC TEST REPORT                                                                         Report No.: FR922534


3.1.5   Test Deviation
         There is no deviation with the original standard.

3.1.6   EUT Operation during Test
         N/A

3.1.7   Results of AC Power Line Conducted Emissions Measurement
         Based on the Comment FCC/TCB, the AC powerline conducted emission is not required for battery powered
         device.




SPORTON International Inc.                                                          Page No.      : 7 of 27
TEL : 886-2-2696-2468                                                               Issued Date   : Mar. 05, 2009
FAX : 886-2-2696-2255                                                               FCC ID        : PAGTR-011


FCC TEST REPORT                                                                                    Report No.: FR922534


3.2 Field Strength of Fundamental Emissions Measurement

3.2.1   Limit
         Devices complying with 47 CFR FCC Part 15 Subpart C, section 15.231(a). The field strength of emissions
         from intentional radiators at 3 meters operated under this Section shall not exceed the following:
                        Frequency Band (MHz)                         Fundamental Emissions Limit (uV/m) at 3m
                              40.66-40.70                                                  2250
                                 70-130                                                    1250
                                130-174                                               1250-3750(**)
                                174-260                                                    3750
                                260-470                                               3750-12500(**)
                               Above 470                                                  12500
         **1. Linear interpolations, the formulas for calculating the maximum permitted fundamental field strengths are
         as follows:
         (1) for the band 130 - 174 MHz, μV/m at 3 meters = 56.81818×(operating frequency, MHz) - 6136.3636;
         (2) for the band 260 - 470 MHz, μV/m at 3 meters = 41.6667×(operating frequency, MHz) - 7083.3333.
         So the field strength of emission limits have been calculated in below table.
                        Carrier Frequency (MHz)                     Fundamental Emissions Limit (dBuV/m) at 3m
                              314.91 MHz                                             75.62 (Average)
                              314.91 MHz                                               95.62 (Peak)

3.2.2   Measuring Instruments and Setting
         Please refer to section 4 of equipments list in this report.The following table is the setting of the receiver.
          Receiver Parameter              Setting
          Attenuation                     Auto
          Center Frequency                Fundamental Frequency
          RB                              120 kHz
          Detector                        Peak / Average




SPORTON International Inc.                                                                     Page No.      : 8 of 27
TEL : 886-2-2696-2468                                                                          Issued Date   : Mar. 05, 2009
FAX : 886-2-2696-2255                                                                          FCC ID        : PAGTR-011


FCC TEST REPORT                                                                                Report No.: FR922534


3.2.3   Test Procedures
         1.   Configure the EUT according to ANSI C63.4. The EUT was placed on the top of the turntable 0.8 meter
              above ground. The phase center of the receiving antenna mounted on the top of a height-variable
              antenna tower was placed 3 meters far away from the turntable.
         2.   Power on the EUT and all the supporting units. The turntable was rotated by 360 degrees to determine
              the position of the highest radiation.
         3.   The height of the broadband receiving antenna was varied between one meter and four meters above
              ground to find the maximum emissions field strength of both horizontal and vertical polarization.
         4.   For each suspected emissions, the antenna tower was scan (from 1 M to 4 M) and then the turntable
              was rotated (from 0 degree to 360 degrees) to find the maximum reading.
         5.   For Fundamental emissions, use the receiver to measure peak and average reading.
         6.   When the radiated emissions limits are expressed in terms of the average value of the emissions, and
              pulsed operation is employed, the measurement field strength shall be determined by averaging over
              one complete pulse train, including blanking intervals, as long as the pulse train does not exceed 0.1
              seconds. As an alternative (provided the transmitter operates for longer than 0.1 seconds) or in cases
              where the pulse train exceeds 0.1 seconds, the measured field strength shall be determined from the
              average absolute voltage during a 0.1 second interval during which the field strength is at its maximum
              value.



3.2.4   Test Setup Layout




3.2.5   Test Deviation
         There is no deviation with the original standard.

3.2.6   EUT Operation during Test
         The EUT was manually operated to be in transmitting mode.


SPORTON International Inc.                                                                 Page No.      : 9 of 27
TEL : 886-2-2696-2468                                                                      Issued Date   : Mar. 05, 2009
FAX : 886-2-2696-2255                                                                      FCC ID        : PAGTR-011


FCC TEST REPORT                                                                              Report No.: FR922534

3.2.7   Test Result of Field Strength of Fundamental Emissions

          Test date          Feb. 27, 2009                   Test Site No.       03CH02-HY
          Temperature        25.1℃                           Humidity            48.5%
          Test Engineer      Eddie                           Configurations      Channel 1




         Note:
         Emission level (dBuV/m) = 20 log Emission level (uV/m).
         Corrected Reading: Antenna Factor + Cable Loss + Read Level - Preamp Factor = Level.
         Receiving maximum fundamental emissions are Vertical Polarization / Horizontal Polarization.




SPORTON International Inc.                                                               Page No.      : 10 of 27
TEL : 886-2-2696-2468                                                                    Issued Date   : Mar. 05, 2009
FAX : 886-2-2696-2255                                                                    FCC ID        : PAGTR-011


FCC TEST REPORT                                                                                Report No.: FR922534


3.3 20dB Spectrum Bandwidth Measurement

3.3.1   Limit
         The bandwidth of the emissions shall be no wider than 0.25% of the center frequency for devices operating
         above 70 MHz and below 900 MHz. So the emission bandwidth limits have been calcuated in below table.
                        Fundamental Frequency                             20dB Bandwidth Limits (kHz)
                              314.91 MHz                                                790

3.3.2   Measuring Instruments and Setting
         Please refer to section 4 of equipments list in this report.The following table is the setting of the Spectrum
         Analyzer.
          Spectrum Parameters         Setting
          Attenuation                 Auto
          Span Frequency              > 20dB Bandwidth
          RB                          10 kHz
          VB                          10 kHz
          Detector                    Peak
          Trace                       Max Hold
          Sweep Time                  Auto

3.3.3   Test Procedures
         1.    The transmitter output (antenna port) was connected to the spectrum analyser in peak hold mode.
         2.    The resolution bandwidth of 10 kHz and the video bandwidth of 10 kHz were used.
         3.    Measured the spectrum width with power higher than 20dB below carrier.

3.3.4   Test Setup Layout




                                      Spectrum Analyzer

3.3.5   Test Deviation
         There is no deviation with the original standard.

3.3.6   EUT Operation during Test
         The EUT was manually operated to be in transmitting mode.




SPORTON International Inc.                                                                 Page No.      : 11 of 27
TEL : 886-2-2696-2468                                                                      Issued Date   : Mar. 05, 2009
FAX : 886-2-2696-2255                                                                      FCC ID        : PAGTR-011


FCC TEST REPORT                                                                                   Report No.: FR922534

3.3.7   Test Result of 20dB Spectrum Bandwidth

          Test date            Feb. 26, 2009                       Test Site No.      TH01-HY
          Temperature          25℃                                 Humidity           55%
          Test Engineer        Tom                                 Configurations     Channel 1


                                     20dB BW                99% OBW                 Limits
                Frequency                                                                               Test Result
                                      (kHz)                   (kHz)                 (MHz)
             314.91 MHz               46.40                   90.00                 0.79                   Complies


         20 dB/99% Bandwidth Plot on 314.91 MHz

                                                             * RBW 10 kHz      Delta 1 [T1 ]
                                                             * VBW 10 kHz                 -0.98 dB
                 Ref -20 dBm            * Att     0 dB       * SWT 20 ms           46.400000000 kHz
                 -20                                                           OBW 90.000000000
                                                                               Marker 1 [T1 ]
                                                                                                  kHz
                                                                                                        *
                                                                                         -81.46   dBm      A
                 -30
                                                                                  314.868200000   MHz
         1 PK
                                                                               Temp 1 [T1 OBW]
         VIEW
                 -40                                                                     -86.49   dBm
                                                                                  314.847800000   MHz
                                                                               Temp 2 [T1 OBW]
                 -50
                                                                                         -88.01   dBm
                                                                                  314.937800000   MHz
                 -60
                        D1 -61.67 dBm


                 -70


                                             1                     1
                 -80
                             D2 -81.67 dBm
                                    T1
                                                                              T2
                 -90



                 -100



                 -110
                                             F2
                                                                   F1
                 -120

                 Center 314.899 MHz                      20 kHz/                       Span 200 kHz




         Date: 26.FEB.2009         14:36:53




SPORTON International Inc.                                                                   Page No.          : 12 of 27
TEL : 886-2-2696-2468                                                                        Issued Date       : Mar. 05, 2009
FAX : 886-2-2696-2255                                                                        FCC ID            : PAGTR-011


FCC TEST REPORT                                                                                     Report No.: FR922534


3.4 Deactivating Time

3.4.1   Limit
         A manually operated transmitter shall employ a switch that will automatically deactivate the transmitter within
         not more than 5 seconds of being released.

3.4.2   Measuring Instruments and Setting
         Please refer to section 4 of equipments list in this report.The following table is the setting of the Spectrum
         Analyzer.
          Spectrum Parameters           Setting
          Attenuation                   Auto
          Span Frequency                0 MHz
          RB                            1000 kHz
          VB                            1000 kHz
          Detector                      Peak
          Trace                         Single Trigger
          Attenuation                   Auto

3.4.3   Test Procedures
         1.    The transmitter output (antenna port) was connected to the spectrum analyser
         2.    Set RBW of spectrum analyzer to 1000kHz and VBW to 1000kHz.
         3.    Use a video trigger with the trigger level set to enable triggering only on full pulses.
         4.    Sweep Time is more than one pulse time.
         5.    Set the center frequency on any frequency would be measure and set the frequency span to zero span.
         6.    Measure the maximum time duration of one single pulse.

3.4.4   Test Setup Layout




                                        Spectrum Analyzer

3.4.5   Test Deviation
         There is no deviation with the original standard.

3.4.6   EUT Operation during Test
         The EUT was manually operated to be in transmitting mode.




SPORTON International Inc.                                                                      Page No.      : 13 of 27
TEL : 886-2-2696-2468                                                                           Issued Date   : Mar. 05, 2009
FAX : 886-2-2696-2255                                                                           FCC ID        : PAGTR-011


FCC TEST REPORT                                                                             Report No.: FR922534

3.4.7   Deactivating Time

          Test date             Feb. 26, 2009                 Test Site No.     TH01-HY
          Temperature           25℃                           Humidity          55%
          Test Engineer         Tom                           Configurations    Channel 1




                                                          RBW 1 MHz       Delta 1 [T1 ]
                                                         * VBW 1 MHz                  0.79 dB
                  Ref -20 dBm           * Att   0 dB      SWT 10 s              320.000000 ms
                  -20                                                     Marker 1 [T1 ]
                                                                                    -86.16 dBm
                                                                                820.000000 ms       A
                  -30

         1 PK *
         VIEW
                  -40



                  -50



                  -60



                  -70



                  -80
                         1 1

                  -90



                  -100



                  -110


                  -120

                  Center 315 MHz                       1 s/




         Date: 26.FEB.2009         14:43:49


         Note: The EUT is deactivated immediately after being released.




SPORTON International Inc.                                                            Page No.          : 14 of 27
TEL : 886-2-2696-2468                                                                 Issued Date       : Mar. 05, 2009
FAX : 886-2-2696-2255                                                                 FCC ID            : PAGTR-011


FCC TEST REPORT                                                                                   Report No.: FR922534

3.4.8   Test Result of Operation Restriction




                                                                                                                    Declared by applicant

                                                                                                                                            Test performance
                                                                                                       Applicable




                                                                                                                                                               Passed
                                     Periodic Operation Restriction




          The transmitter is used for
              security or safety applications             other applications
          The transmitter is operated
              manually                                    automatically
          Periodic operation according to
              47 CFR FCC Part 15 Subpart C             15.231(a)
          Only control signals are sent and there is on continuous transmission.
          (1) A manually operated transmitter shall employ a switch that will automatically
          deactivate the transmitter within not more than 5 seconds of being released.
          (2) A transmitter activated automatically shall cease transmission within 5 seconds
          after activation.
          (3) Periodic transmissions at regular predetermined intervals are
              not permitted
              permitted with total transmission time of two seconds per hour or less (for
          polling or supervision transmission to determine system integrity of transmitters
          used in security or safety applications)
              47 CFR FCC Part 15 Subpart C 15.231(e)
          The device is provided with a means for automatically limiting operation so that the
          duration of each transmissions is not greater than one second and the silent period
          between transmissions is at least 30 times the duration of the transmission but in
          no case less than 10 seconds.
         Note: Result may be based on the applicant declaration (i.e. no test is performed). However, in this casethere
         is no vertification by the test laboratory.




SPORTON International Inc.                                                                    Page No.              : 15 of 27
TEL : 886-2-2696-2468                                                                         Issued Date           : Mar. 05, 2009
FAX : 886-2-2696-2255                                                                         FCC ID                : PAGTR-011


FCC TEST REPORT                                                                                Report No.: FR922534


3.5 Radiated Emissions Measurement

3.5.1   Limit
         Devices complying with 47 CFR FCC Part 15 Subpart C, section 15.231(a). The field strength of emissions
         from intentional radiators at 3 meters operated under this Section shall not exceed the following:
                          Frequency Band (MHz)                         Spurious Emissions Limit (up/m) at 3m
                               40.66-40.70                                               225
                                   70-130                                                125
                                   130-174                                           125-375(**)
                                   174-260                                               375
                                   260-470                                          375-1250(**)
                                  Above 470                                             1250
         **1. Linear interpolations, the formulas for calculating the maximum permitted fundamental field strengths are
         as follows:
         (1) for the band 130 - 174 MHz, μV/m at 3 meters = 56.81818×(operating frequency, MHz) - 6136.3636;
         (2) for the band 260 - 470 MHz, μV/m at 3 meters = 41.6667×(operating frequency, MHz) - 7083.3333.
         (3)The maximum permitted unwanted emissions level is 20 dB below the maximum permitted fundamental
         level. In addition field strength of any emissions which appear inside of the restriction band shall not exceed
         the general radiated emissions limits in Section 15.209(a).
                        Frequencies                    Field Strength                  Measurement Distance
                          (MHz)                      (micorvolts/meter)                        (meters)
                        0.009~0.490                     2400/F (KHz)                                300
                        0.490~1.705                     24000/F (KHz)                               30
                        1.705~30.0                            30                                    30
                          30~88                              100                                      3
                          88~216                             150                                      3
                         216~960                             200                                      3
                         Above 960                           500                                      3




SPORTON International Inc.                                                                 Page No.       : 16 of 27
TEL : 886-2-2696-2468                                                                      Issued Date    : Mar. 05, 2009
FAX : 886-2-2696-2255                                                                      FCC ID         : PAGTR-011


FCC TEST REPORT                                                                                Report No.: FR922534


3.5.2   Measuring Instruments and Setting
         Please refer to section 4 of equipments list in this report.The following table is the setting of spectrum
         analyzer and receiver.
          Spectrum Parameter                           Setting
          Attenuation                                  Auto
          Start Frequency                              1000 MHz
          Stop Frequency                               10th carrier harmonic
          RB / VB (emission in restricted band)        1MHz / 1MHz for Peak, 1 MHz / 10Hz for Average
          RB / VB (other emission)                     100KHz / 100KHz for peak


          Receiver Parameter                           Setting
          Attenuation                                  Auto
          Start ~ Stop Frequency                       9kHz~150kHz / RB 200Hz for QP
          Start ~ Stop Frequency                       150kHz~30MHz / RB 9kHz for QP
          Start ~ Stop Frequency                       30MHz~1000MHz / RB 120kHz for QP



3.5.3   Test Procedures
         1.   Configure the EUT according to ANSI C63.4. The EUT was placed on the top of the turntable 0.8 meter
              above ground. The phase center of the receiving antenna mounted on the top of a height-variable
              antenna tower was placed 3 meters far away from the turntable.
         2.   Power on the EUT and all the supporting units. The turntable was rotated by 360 degrees to determine
              the position of the highest radiation.
         3.   The height of the broadband receiving antenna was varied between one meter and four meters above
              ground to find the maximum emissions field strength of both horizontal and vertical polarization.
         4.   For each suspected emissions, the antenna tower was scan (from 1 M to 4 M) and then the turntable
              was rotated (from 0 degree to 360 degrees) to find the maximum reading.
         5.   Set the test-receiver system to Peak or CISPR quasi-peak Detect Function with specified bandwidth
              under Maximum Hold Mode.
         6.   For emissions above 1GHz, use 1MHz VBW and RBW for peak reading. Then 1MHz RBW and 10Hz
              VBW for average reading in spectrum analyzer.
         7.   When the radiated emissions limits are expressed in terms of the average value of the emissions, and
              pulsed operation is employed, the measurement field strength shall be determined by averaging over
              one complete pulse train, including blanking intervals, as long as the pulse train does not exceed 0.1
              seconds. As an alternative (provided the transmitter operates for longer than 0.1 seconds) or in cases
              where the pulse train exceeds 0.1 seconds, the measured field strength shall be determined from the
              average absolute voltage during a 0.1 second interval during which the field strength is at its maximum
              value.
SPORTON International Inc.                                                                 Page No.      : 17 of 27
TEL : 886-2-2696-2468                                                                      Issued Date   : Mar. 05, 2009
FAX : 886-2-2696-2255                                                                      FCC ID        : PAGTR-011


FCC TEST REPORT                                                                              Report No.: FR922534

         8.   If the emissions level of the EUT in peak mode was 3 dB lower than the average limit specified, then
              testing will be stopped and peak values of EUT will be reported, otherwise, the emissions which do not
              have 3 dB margin will be repeated one by one using the quasi-peak method for below 1GHz.
         9.   For testing above 1GHz, the emissions level of the EUT in peak mode was lower than average limit (that
              means the emissions level in peak mode also complies with the limit in average mode), then testing will
              be stopped and peak values of EUT will be reported, otherwise, the emissions will be measured in
              average mode again and reported.
         10. In case the emission is lower than 30MHz, loop antenna has to be used for measurement and the
              recorded data should be QP measured by receiver. High – Low scan is not required in this case.

3.5.4   Test Setup Layout
         For radiated emissions below 30MHz




         For radiated emissions above 30MHz




SPORTON International Inc.                                                               Page No.      : 18 of 27
TEL : 886-2-2696-2468                                                                    Issued Date   : Mar. 05, 2009
FAX : 886-2-2696-2255                                                                    FCC ID        : PAGTR-011


FCC TEST REPORT                                                                                   Report No.: FR922534


3.5.5   Test Deviation
         There is no deviation with the original standard.

3.5.6   EUT Operation during Test
         The EUT was manually operated to be in transmitting mode.

3.5.7   Results of Radiated Emissions (9kHz~30MHz)

          Test date            Feb. 27, 2009                   Test Site No.      03CH02-HY
          Temperature          25.1℃                           Humidity           48.5%
          Test Engineer        Eddie                           Configurations     Channel 1


                 Freq.                  Level                Over Limit          Limit Line                 Remark
                 (MHz)                 (dBuV)                  (dB)               (dBuV)
                    -                     -                      -                    -                     See Note
         Note:
         The amplitude of spurious emissions which are attenuated by more than 20 dB below the permissible value
         has no need to be reported.
         Distance extrapolation factor = 40 log (specific distance / test distance) (dB);
         Limit line = specific limits (dBuV) + distance extrapolation factor.




SPORTON International Inc.                                                                    Page No.       : 19 of 27
TEL : 886-2-2696-2468                                                                         Issued Date    : Mar. 05, 2009
FAX : 886-2-2696-2255                                                                         FCC ID         : PAGTR-011


FCC TEST REPORT                                                                 Report No.: FR922534


3.5.8   Results for Radiated Emissions (30MHz~10th Harmonic)

          Test date          Feb. 27, 2009     Test Site No.    03CH02-HY
          Temperature        25.1℃             Humidity         48.5%
          Test Engineer      Eddie             Configurations   Channel 1
         Horizontal




SPORTON International Inc.                                                  Page No.      : 20 of 27
TEL : 886-2-2696-2468                                                       Issued Date   : Mar. 05, 2009
FAX : 886-2-2696-2255                                                       FCC ID        : PAGTR-011


FCC TEST REPORT                                                                          Report No.: FR922534



         Vertical




         Note:
         The amplitude of spurious emissions which are attenuated by more than 20 dB below the permissible value
         has no need to be reported.
         Emission level (dBuV/m) = 20 log Emission level (uV/m).
         Corrected Reading: Antenna Factor + Cable Loss + Read Level - Preamp Factor = Level.




SPORTON International Inc.                                                           Page No.      : 21 of 27
TEL : 886-2-2696-2468                                                                Issued Date   : Mar. 05, 2009
FAX : 886-2-2696-2255                                                                FCC ID        : PAGTR-011


FCC TEST REPORT                                                                  Report No.: FR922534


3.5.9   Results for Radiated Emissions (1GHz~10th harmonic of highest frequency)

          Test date          Feb. 27, 2009      Test Site No.    03CH02-HY
          Temperature        25.1℃              Humidity         48.5%
          Test Engineer      Eddie              Configurations   Channel 1
         Horizontal




SPORTON International Inc.                                                   Page No.      : 22 of 27
TEL : 886-2-2696-2468                                                        Issued Date   : Mar. 05, 2009
FAX : 886-2-2696-2255                                                        FCC ID        : PAGTR-011


FCC TEST REPORT                                                                          Report No.: FR922534



         Vertical




         Note:
         The amplitude of spurious emissions which are attenuated by more than 20 dB below the permissible value
         has no need to be reported.
         Emission level (dBuV/m) = 20 log Emission level (uV/m).
         Corrected Reading: Antenna Factor + Cable Loss + Read Level - Preamp Factor = Level.




SPORTON International Inc.                                                           Page No.      : 23 of 27
TEL : 886-2-2696-2468                                                                Issued Date   : Mar. 05, 2009
FAX : 886-2-2696-2255                                                                FCC ID        : PAGTR-011


FCC TEST REPORT                                                                                 Report No.: FR922534

3.6 Antenna Requirements

3.6.1   Limit
         Except for special regulations, the Low-power Radio-frequency Devices must not be equipped with any
         jacket for installing an antenna with extension cable. An intentional radiator shall be designed to ensure that
         no antenna other than that furnished by the responsible party shall be used with the device. The use of a
         permanently attached antenna or of an antenna that uses a unique coupling to the intentional radiator shall
         be considered sufficient to comply with the provisions of this Section. The manufacturer may design the unit
         so that the user can replace a broken antenna, but the use of a standard antenna jack or electrical connector
         is prohibited. Further, this requirement does not apply to intentional radiators that must be professionally
         installed.



3.6.2   Antenna Connector Construction
         Please refer to section 2.2 in this test report, all antenna connectors comply with the requirements.




SPORTON International Inc.                                                                 Page No.      : 24 of 27
TEL : 886-2-2696-2468                                                                      Issued Date   : Mar. 05, 2009
FAX : 886-2-2696-2255                                                                      FCC ID        : PAGTR-011


FCC TEST REPORT                                                                                    Report No.: FR922534


4. LIST OF MEASURING EQUIPMENTS
                                                                                              Calibration
       Instrument         Manufacturer     Model No.      Serial No.      Characteristics                         Remark
                                                                                                 Date
                                                                                                                  Conducted
     Spectrum Analyzer          R&S           FSP30         100023          9kHz ~ 30GHz      Jan. 09, 2009
                                                                                                                  (TH01-HY)
                                                                                                                  Conducted
        Power Meter             R&S           NRVS          100444          DC ~ 40GHz        Jul. 11, 2008
                                                                                                                  (TH01-HY)
                                                                                                                  Conducted
        Power Sensor            R&S          NRV-Z51        100458          DC ~ 30GHz        Jul. 11, 2008
                                                                                                                  (TH01-HY)
                                                                                                                  Conducted
        Power Sensor            R&S          NRV-Z32        100057         30MHz ~ 6GHz       Jul. 11, 2008
                                                                                                                  (TH01-HY)
                                                                                                                  Conducted
      DC Power Source           G.W.        GPC-6030D       C671845         DC 1V ~ 60V       Mar. 13, 2008
                                                                                                                  (TH01-HY)
     Temp. and Humidity                                                                                           Conducted
                             Giant Force   GTH-225-20-S   MAB0103-001            N/A          Jul. 18, 2008
         Chamber                                                                                                  (TH01-HY)
                                                                                                                  Conducted
       RF CABLE-1m            Jye Bao         RG142        CB034-1m        20MHz ~ 7GHz       Dec. 01, 2008
                                                                                                                  (TH01-HY)
                                                                                                                  Conducted
       RF CABLE-2m            Jye Bao         RG142        CB035-2m        20MHz ~ 1GHz       Dec. 01, 2008
                                                                                                                  (TH01-HY)
        Vector Signal                                                                                             Conducted
                                R&S         SMU200A         102098         100kHz ~ 6GHz      Dec. 14, 2008
         Generator                                                                                                (TH01-HY)
                                                                                                                  Conducted
      Signal Generator          R&S          SMR40          100116         10MHz ~ 40GHz      Mar. 10, 2008
                                                                                                                  (TH01-HY)
                                                                                                                  Conducted
        Oscilloscope          Tektonix       TDS380         B016197        400MHz/ 2GS/s      Jun. 27, 2008
                                                                                                                  (TH01-HY)
    Note: Calibration Interval of instruments listed above is one year.

                                                                                              Calibration
       Instrument         Manufacturer     Model No.      Serial No.      Characteristics                         Remark
                                                                                                 Date
     3m Semi Anechoic                                                      30 MHz - 1 GHz                          Radiation
                          SIDT FRANKONIA     SAC-3M       03CH02-HY                           May 12, 2008
         Chamber                                                                3m                               (03CH02-HY)
                                                                                                                   Radiation
          Amplifier            Agilent        8447D       2944A11146      100 kHz – 1.3 GHz   Jul. 11, 2008
                                                                                                                 (03CH02-HY)
          Spectrum                                                                                                 Radiation
                                R&S           FSP40        100305/040       9 kHz - 40GHz     Feb. 04, 2009
          Analyzer                                                                                               (03CH02-HY)
                                                                                                                   Radiation
        Bilog Antenna        SCHAFFNER      CBL61128         2723          30 MHz - 2 GHz     Nov. 30, 2008
                                                                                                                 (03CH02-HY)
                                                                                                                   Radiation
         Turn Table             HD           DS 420        420/649/00       0 - 360 degree        N/A
                                                                                                                 (03CH02-HY)
                                                                                                                   Radiation
        Antenna Mast            HD           MA 240        240/559/00         1m-4m               N/A
                                                                                                                 (03CH02-HY)
                                                                                                                   Radiation
       RF Cable-R03m          Jye Bao         RG142          CB020         30 MHz - 1 GHz     Dec. 17, 2008
                                                                                                                 (03CH02-HY)
                                                                                                                   Radiation
          Amplifier            Agilent        8449B       3008A02373      1GHz – 26.5 GHz     Jul. 16, 2008
                                                                                                                 (03CH02-HY)
                                                                                                                   Radiation
        Horn Antenna      ETS-LINDGREN         3117        00091920         1GHz~18GHz        Oct. 22, 2008
                                                                                                                 (03CH02-HY)
                                                                                                                   Radiation
       RF Cable-HIGH          SUHNER       SUCOFLEX106    03CH02-HY         1GHz~40GHz        Dec. 17, 2008
                                                                                                                 (03CH02-HY)
    Note: Calibration Interval of instruments listed above is one year.

                                                                                              Calibration
       Instrument         Manufacturer     Model No.      Serial No.      Characteristics                         Remark
                                                                                                 Date
                                                                                                                  Conducted
      AC Power Source           HPC         HPA-500W      HPA-9100024       AC 0 ~ 300V       May 30, 2008*
                                                                                                                  (TH01-HY)
    Note: Calibration Interval of instruments listed above is two year.

SPORTON International Inc.                                                                    Page No.        : 25 of 27
TEL : 886-2-2696-2468                                                                         Issued Date     : Mar. 05, 2009
FAX : 886-2-2696-2255                                                                         FCC ID          : PAGTR-011


FCC TEST REPORT                                                                                    Report No.: FR922534


5. TEST LOCATION
      SHIJR         ADD      :   6Fl., No. 106, Sec. 1, Shintai 5th Rd., Shijr City, Taipei, Taiwan 221, R.O.C.
                    TEL      :   886-2-2696-2468
                    FAX      :   886-2-2696-2255
      HWA YA        ADD      :   No. 52, Hwa Ya 1st Rd., Kwei-Shan Hsiang, Tao Yuan Hsien, Taiwan, R.O.C.
                    TEL      :   886-3-327-3456
                    FAX      :   886-3-318-0055
      LINKOU        ADD      :   No. 30-2, Dingfu Tsuen, Linkou Shiang, Taipei, Taiwan 244, R.O.C
                    TEL      :   886-2-2601-1640
                    FAX      :   886-2-2601-1695
      DUNGHU        ADD      :   No. 3, Lane 238, Kangle St., Neihu Chiu, Taipei, Taiwan 114, R.O.C.
                    TEL      :   886-2-2631-4739
                    FAX      :   886-2-2631-9740
      JUNGHE        ADD      :   7Fl., No. 758, Jungjeng Rd., Junghe City, Taipei, Taiwan 235, R.O.C.
                    TEL      :   886-2-8227-2020
                    FAX      :   886-2-8227-2626
      NEIHU         ADD      :   4Fl., No. 339, Hsin Hu 2nd Rd., Taipei 114, Taiwan, R.O.C.
                    TEL      :   886-2-2794-8886
                    FAX      :   886-2-2794-9777
      JHUBEI        ADD      :   No.8, Lane 728, Bo-ai St., Jhubei City, HsinChu County 302, Taiwan, R.O.C.
                    TEL      :   886-3-656-9065
                    FAX      :   886-3-656-9085




SPORTON International Inc.                                                                     Page No.      : 26 of 27
TEL : 886-2-2696-2468                                                                          Issued Date   : Mar. 05, 2009
FAX : 886-2-2696-2255                                                                          FCC ID        : PAGTR-011


FCC TEST REPORT                           Report No.: FR922534


6. TAF CERTIFICATE OF ACCREDITATION




SPORTON International Inc.            Page No.      : 27 of 27