Test report above 1 GHz

FCC ID: PADWF126

Test Report

Download: PDF
FCCID_3921720

                                                                                              Report No.: C180620Z02-RP1


                              FCC 47 CFR PART 15 SUBPART C


                                                   TEST REPORT

                                                               For
                                                    KICKR HEADWIND
                                                    Model: WF126US
                                                      Brand: N/A
                                                 Test Report Number:
                                                      C180620Z02-RP1

                                                           Issued for

                                                 Wahoo Fitness L.L.C.
                          90 W WIEUCA RD NE STE 110 ATLANTA GA 30342

                                                           Issued by:

                 COMPLIANCE CERTIFICATION SERVICES (SHENZHEN) INC.
                No.10-1, Mingkeda Logistics Park, No.18, Huanguan South Rd.,
                      Guan Lan Town, Baoan District, Shenzhen China
                                   TEL: 86-755-28055000
                                                FAX: 86-755-28055221
                                            E-Mail: service@ccssz.com
                                              Issued Date: Jun 20, 2018




Note: This report shall not be reproduced except in full, without the written approval of
Compliance Certification Services (Shenzhen) Inc. This document may be altered or
revised by Compliance Certification Services (Shenzhen) Inc. personnel only, and shall be
noted in the revision section of the document. The client should not use it to claim product
endorsement by TAF, A2LA, NVLAP, NIST, CNAS or any government agencies. The test
result of this report relate only to the tested sample identified in this report.


FCC ID: PADWF126                                                                                                  Page 1 / 15
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services (Shenzhen) Inc.


                                                                                                      Report No.: C180620Z02-RP1


                                                    Revision History

                                                                                                      Effect
 Rev.            Issue Date                                     Revisions                             Page           Revised By
  00            Jun 20, 2018                                   Initial Issue                          ALL             Anna Liu




FCC ID: PADWF126                                                                                                             Page 2 / 15
  This report shall not be reproduced except in full, without the written approval of Compliance Certification Services (Shenzhen) Inc.


                                                                                                                                        Report No.: C180620Z02-RP1



                                                                     TABLE OF CONTENTS


1. TEST RESULT CERTIFICATION ...................................................................................................................4

2. EUT DESCRIPTION ...............................................................................................................................................5

3. TEST METHODOLOGY .......................................................................................................................................6
    3.1 DESCRIPTION OF TEST MODES ............................................................................................................6
    3.2 SETUP CONFIGURATION OF EUT .........................................................................................................6
    3.3 SUPPORT EQUIPMENT ..................................................................................................................................6

4. FACILITIES AND ACCREDITATIONS ........................................................................................................7
    4.1 FACILITIES ..............................................................................................................................................................7
    4.2 ACCREDITATIONS.............................................................................................................................................7
    4.3 MEASUREMENT UNCERTAINTY..............................................................................................................7

5. FCC PART 15.249 REQUIREMENTS..........................................................................................................8
    5.1 RADIATED EMISSIONS...................................................................................................................................8




FCC ID: PADWF126                                                                                                                                                      Page 3 / 15
     This report shall not be reproduced except in full, without the written approval of Compliance Certification Services (Shenzhen) Inc.


                                                                                              Report No.: C180620Z02-RP1


1. TEST RESULT CERTIFICATION

    Product             KICKR HEADWIND

     Model              WF126US

     Brand              N/A

    Tested              Jun 20, 2018


  Applicant             Wahoo Fitness L.L.C.


Manufacturer 90 W WIEUCA RD NE STE 110 ATLANTA GA 30342



                                                 APPLICABLE STANDARDS

                            STANDARD                                                          TEST RESULT

                FCC 47 CFR Part 15 Subpart C                                            No non-compliance noted




We hereby certify that:
The above equipment was tested by Compliance Certification Services (Shenzhen) Inc. The
test data, data evaluation, test procedures, and equipment configurations shown in this report
were made in accordance with the procedures given in ANSI C63.10:2013 and the energy
emitted by the sam ple EUT tested as described in this report is in com pliance with conducted
and radiated emission limits of FCC Rules Part 15.207, 15.209 and 15.249.

The test results of this report relate only to the tested sample EUT identified in this report.
Approved by:                                                      Reviewed by:




Eve Wang                                                           Nancy Fu
Supervisor of EMC Dept.                                            Supervisor of Report Dept.
Com pliance Certification Services (Shenzhen) Inc.                 Com pliance Certification Services (Shenzhen) Inc.




FCC ID: PADWF126                                                                                                    Page 4 / 15
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services (Shenzhen) Inc.


                                                                                              Report No.: C180620Z02-RP1


2. EUT DESCRIPTION
 Product                                KICKR HEADWIND
 Model Number                           WF126US
 Brand                                 N/A
 Model Discrepancy                     N/A
 Identify Number                       C180620Z02-RP1

 Received Date                         Jun 20, 2018
 Power Supply                          100-120V 50-60Hz 1.3A 65W
 Frequency Range                       2457 MHz

                                       ANT+
 Modulation Technique

 Number of Channels                    1 Channels
 Antenna Specification                 Ceramic Antenna with 5.46dBi gain (Max)
 Hardware Version                      V1.0
 Software Version                      V1.0

Note: This submittal(s) (test report) is intended for FCC ID: PADWF126 filing to comply
with Section 15.207, 15.209 and 15.249 of the FCC Part 15, Subpart C Rules.




FCC ID: PADWF126                                                                                                    Page 5 / 15
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services (Shenzhen) Inc.


                                                                                                Report No.: C180620Z02-RP1


3. TEST METHODOLOGY
3.1 DESCRIPTION OF TEST MODES
The EUT has been tested under operating condition.
Use Certification Tool 1.26 to control the EUT for staying in continuous transmitting
and receiving mode.
  Test Item     Test mode                                                Worse mode
  Radiated      Mode 1: TX
  Emission
Note:
1. Channel 2457MHz were chosen for pre-testing for GFSK and print in the report.
2. Radiated band edges were tested with both fixed and hopping mode; the fixed mode
   was the worse case and recorded in the report.




3.2 SETUP CONFIGURATION OF EUT
See test photographs attached in Appendix 1 for the actual connections between EUT
and support equipment.


3.3 SUPPORT EQUIPMENT
 No.   Equipment             Model No.                 Serial No.          FCC ID        Brand         Data Cable        Power Cord

   1     Notebook         TianYi 310-14ISK                 NA                DoC         Lenovo              NA                NA

Notes:
Grounding was established in accordance with the manufacturer’s requirements
and conditions for the intended use.




FCC ID: PADWF126                                                                                                       Page 6 / 15
   This report shall not be reproduced except in full, without the written approval of Compliance Certification Services (Shenzhen) Inc.


                                                                                              Report No.: C180620Z02-RP1


4. FACILITIES AND ACCREDITATIONS
4.1 FACILITIES
All measurement facilities used to collect the measurement data are located at
    No.10-1, Mingkeda Logistics Park, No.18, Huanguan South Rd.,
    Guan Lan Town, Baoan District, Shenzhen, China

The sites are constructed in conformance with the requirements of ANSI C63.10:2013,
ANSI C63.7 and CISPR Publication 22. All receiving equipment conforms to CISPR
Publication 16-1, “Radio Interference Measuring Apparatus and Measurement Methods.”

4.2 ACCREDITATIONS
Our laboratories are accredited and approved by the following accreditation body
according to ISO/IEC 17025.
                USA              A2LA
                China            CNAS
The measuring facility of laboratories has been authorized or registered by the
following approval agencies.
                USA              FCC
               Japan              VCCI(C-4815, R-4320, T-2317, G-10624)
               Canada             INDUSTRY CANADA
Copies of granted accreditation certificates are available for downloading from our web
site, http://www.ccssz.com

4.3 MEASUREMENT UNCERTAINTY
Where relevant, the following measurement uncertainty levels have been estimated
for tests performed on the EUT as specified in CISPR 16-4-2:

                                 Parameter                                           Uncertainty
                    Radiated Emission, 30 to 200 MHz
                                                                                       +/-3.6880dB
                             Test Site : 966(2)
                   Radiated Emissi on, 200 to 1000 MHz
                                                                                       +/-3.6695dB
                             Test Site : 966(2)
                     Radiated Emission, 1 to 8 GHz                                    +/-5.1782dB
                        Radiated Emission, 8 to 18 GHz                                +/-5.2173dB


This uncertainty represents an expanded uncertainty expressed at approximately the
95% confidence level using a coverage factor of k=2.
The measured result is above (below) the specification limit by a margin less than the
measurement uncertainty; it is therefore not possible to state compliance based on the 95%
level of confidence. However, the result indicates that compliance (non-compliance) is
more probable than non-compliance) with the specification limit.




FCC ID: PADWF126                                                                                                    Page 7 / 15
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services (Shenzhen) Inc.


                                                                                              Report No.: C180620Z02-RP1


5. FCC PART 15.249 REQUIREMENTS
5.1 RADIATED EMISSIONS

LIMIT
1. Except as provided elsewhere in this Subpart, the emissions from an intentional
   radiator shall not exceed the field strength levels specified in the following table:
                                                                                           Measurement Distance
            Frequency (MHz)                       Field Strength (mV/m)
                                                                                                   (m)
                  0.009-0.490                             2400/F(kHz)                              300
                  0.490-1.705                            24000/F(kHz)                                     30
                   1.705-30.0                                    30                                       30
                      30-88                                     100*                                       3
                     88-216                                     150*                                       3
                    216-960                                     200*                                       3
                  Above 960                                     500                                        3
    Note: Except as provided in paragraph (g), fundamental emissions from intentional
    radiators operating under this Section shall not be located in the frequency bands 54-
    72 MHz, 76-88 MHz, 174-216 MHz or 470-806 MHz. However, operation within these
    frequency bands is permitted under other sections of this Part, e.g., Sections 15.231
    and 15.241.
2. In the above emission table, the tighter limit applies at the band edges.
                                                       Field Strength                          Field Strength
              Frequency (Hz)
                                                      (μV/m at 3-meter)                      (dBμV/m at 3-meter)
                      30-88                                  100                                     40
                     88-216                                      150                                     43.5
                     216-960                                     200                                       46
                   Above 960                                     500                                       54




FCC ID: PADWF126                                                                                                    Page 8 / 15
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services (Shenzhen) Inc.


                                                                                                        Report No.: C180620Z02-RP1


MEASUREMENT EQUIPMENT USED
                                         Radiated Emission Test Site 966(2)
                                                                                       Serial                Last                Due
Name of Equipment                  Manufacturer           Model Number
                                                                                      Number              Calibration         Calibration
PSA Series Spectrum
                                         Agilent                  N9010 A           MY52221469             02/18/2018          02/19/2019
     Analy z er
  EMI TEST RECEI V E R          ROHD E & S CH W A R Z              ESCI                  10078 3           02/18/2018          02/19/2019

         Amplif ier                      EMEC                      EM33 0                06066 1           02/17/2018          03/16/2019

   High Nois e Amplif ie r               Agilent                   8449B              3008A 0 1 83 8        02/20/ 2 01 8      02/19/2019

      Loop Anten na                 COM-P O W E R                 AL-130                 12104 4            09/25/ 2 01 7      09/24/2018

      Bilog Anten na                SCHA FFN E R                CBL6143                   5082              02/20/ 2 01 8      02/19/2019

      Horn Antenn a               SCHW A R ZB E CK              BBHA 9 12 0              D286               02/20/ 2 01 8      02/19/2019

Board -B an d Horn Anten na         Schwarzbeck                BBHA 9170               9170-4 9 7           02/20/ 2 01 8      02/19/2019

        Turn Table                         N/A                      N/A                    N/A                   N.C.R             N.C.R

     Anten n a Tower                     SUNO L                     TLT2                   N/A                   N.C.R             N.C.R

         Cont roller               Sunol Scienc e s              SC104V                02231 0 -1                N.C.R             N.C.R

         Cont roller                       CT                       N/A                    N/A                   N.C.R             N.C.R

 Temp. / Humidit y Meter               Any met re                  JR913                   N/A              02/20 20 1 8       02/19/2019

         Test S/W                        FARAD                                          LZ-RF / CCS-SZ-3A2
Remark: Each piece of equipment is scheduled for calibration once a year.

Test Configuration
Below 30MHz


                                                                                                       Antenna
                                                                                                        tower


                                          3m
                                                                                                          Loop antenna
         EUT
                                            4m
                                                                                                          Spectrum /
                                                                                                           Receiver


                  Turntable
                                  0.8m              1m
                                                                                                       Pre-amp




    Reference ground plane




FCC ID: PADWF126                                                                                                              Page 9 / 15
   This report shall not be reproduced except in full, without the written approval of Compliance Certification Services (Shenzhen) Inc.


                                                                                               Report No.: C180620Z02-RP1




Below 1 GHz


                                                                                             Antenna
                                                                                              tower


                                    3m                                                        Bi-log
        EUT                                                                                  antenna
                                         4m
                                                                                            Spectrum
                                                                                            analyzer


               Turntable
                                 0.8m         1m




   Reference ground plane




Above 1 GHz


                                                                                 Antenna
                                                                                  tower


                   3 & 1m                                                        Horn
  EUT                                                                           antenna

                               4m
                                                                                 Spectrum
                                                                                 analyzer


       Turntable
                     1.5m           1m
                                               30cm
                                                                                    Pre-amp




FCC ID: PADWF126                                                                                                      Page 10 / 15
  This report shall not be reproduced except in full, without the written approval of Compliance Certification Services (Shenzhen) Inc.


                                                                                              Report No.: C180620Z02-RP1


MEASURING SETTING
      The following table is the setting of spectrum analyzer and receiver.
       Spectrum Parameter                     Setting
       Attenuation                                            Auto
       Start Frequency                                        1000 MHz
       Stop Frequency                                         10th carrier harmonic
       RB / VB (Emission in restricted                        1MHz / 1MHz for Peak, 1 MHz / 1/T for
       band)                                                  Average
       RB / VB (Emission in non-restricted                    1MHz / 1MHz for Peak, 1 MHz / 1/T for
       band)                                                  Average

       Receiver Parameter                                     Setting
       Attenuation                                            Auto
       Start ~ Stop Frequency                                 9kHz~150kHz / RB 200Hz for QP/AVG
       Start ~ Stop Frequency                                 150kHz~30MHz / RB 9kHz for QP/AVG
       Start ~ Stop Frequency                                 30MHz~1000MHz / RB 100kHz for QP


TEST PROCEDURE
      1) Sequence of testing 9 kHz to 30
      MHz Setup:
      --- The equipment was set up to simulate a typical usage like described in the
      user manual or described by manufacturer.
      --- If the EUT is a tabletop system, a rotatable table with 0.8 m height is used.
      --- If the EUT is a floor standing device, it is placed on the ground.
      --- Auxiliary equipment and cables were positioned to simulate normal
      operation conditions.
      --- The AC power port of the EUT (if available) is connected to a power outlet below
      the turntable.
      --- The measurement distance is 3 meter.
      --- The EUT was set into operation.


      Pre measurement:
      --- The turntable rotates from 0°to 315°using 45°steps.
      --- The antenna height is 0.8 meter.
      --- At each turntable position the analyzer sweeps with peak detection to find the
      maximum of all emissions

FCC ID: PADWF126                                                                                                    Page 11 / 15
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services (Shenzhen) Inc.


                                                                                              Report No.: C180620Z02-RP1




      Final measurement:

      --- Identified emissions during the pre measurement the software maximizes by
      rotating the turntable position (0°to 360°) and by rotating the elevation axes (0°to
      360°).
      --- The final measurement will be done in the position (turntable and elevation)
      causing the highest emissions with QPK detector.
      --- The final levels, frequency, measuring time, bandwidth, turntable position,
      correction factor, margin to the limit and limit will be recorded. Also a plot with
      the graph of the pre measurement and the limit will be stored.


      2) Sequence of testing 30 MHz to 1
      GHz Setup:

      --- The equipment was set up to simulate a typical usage like described in the
      user manual or described by manufacturer.
      --- If the EUT is a tabletop system, a table with 0.8 m height is used, which is placed
      on the ground plane.
      --- If the EUT is a floor standing device, it is placed on the ground plane with
      insulation between both.
      --- Auxiliary equipment and cables were positioned to simulate normal
      operation conditions
      --- The AC power port of the EUT (if available) is connected to a power outlet below
      the turntable.
      --- The measurement distance is 3 meter.
      --- The EUT was set into operation.

      Pre measurement:

      --- The turntable rotates from 0°to 315°using 45°steps.
      --- The antenna is polarized vertical and horizontal.
      --- The antenna height changes from 1 to 3 meter.
      --- At each turntable position, antenna polarization and height the analyzer
      sweeps three times in peak to find the maximum of all emissions.




FCC ID: PADWF126                                                                                                    Page 12 / 15
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services (Shenzhen) Inc.


                                                                                              Report No.: C180620Z02-RP1


      Final measurement:
      --- The final measurement will be performed with minimum the six highest peaks.
      --- According to the maximum antenna and turntable positions of premeasurement
      the software maximize the peaks by changing turntable position (± 45°) and antenna
      movement between 1 and 4 meter.
      --- The final measurement will be done with QP detector with an EMI receiver.
      --- The final levels, frequency, measuring time, bandwidth, antenna height,
      antenna polarization, turntable angle, correction factor, margin to the limit and limit
      will be recorded. Also a plot with the graph of the premeasurement with marked
      maximum final measurements and the limit will be stored.


      3) Sequence of testing 1 GHz to 18
      GHz Setup:

      --- The equipment was set up to simulate a typical usage like described in the
      user manual or described by manufacturer.
      --- If the EUT is a tabletop system, a rotatable table with 1.5 m height is used.
      --- If the EUT is a floor standing device, it is placed on the ground plane with insulation
      between both.
      --- Auxiliary equipment and cables were positioned to simulate normal
      operation conditions
      --- The AC power port of the EUT (if available) is connected to a power outlet below
      the turntable.
      --- The measurement distance is 3 meter.
      --- The EUT was set into operation.

      Pre measurement:
      --- The turntable rotates from 0°to 315°using 45°steps.
      --- The antenna is polarized vertical and horizontal.
      --- The antenna height scan range is 1 meter to 2.5 meter.
      --- At each turntable position and antenna polarization the analyzer sweeps with
      peak detection to find the maximum of all emissions.




FCC ID: PADWF126                                                                                                    Page 13 / 15
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services (Shenzhen) Inc.


                                                                                              Report No.: C180620Z02-RP1


      Final measurement:
      --- The final measurement will be performed with minimum the six highest peaks.
      --- According to the maximum antenna and turntable positions of premeasurement
      the software maximize the peaks by changing turntable position (± 45°) and antenna
      movement between 1 and 4 meter. This procedure is repeated for both antenna
      polarizations.
      --- The final measurement will be done in the position (turntable, EUT-table and antenna
      polarization) causing the highest emissions with Peak and Average detector.
      --- The final levels, frequency, measuring time, bandwidth, turntable position,
      EUT-table position, antenna polarization, correction factor, margin to the limit and
      limit will be recorded. Also a plot with the graph of the pre measurement with marked
      maximum final measurements and the limit will be stored.

      4) Sequence of testing above 18
      GHz Setup:

      --- The equipment was set up to simulate a typical usage like described in the
      user manual or described by manufacturer.
      --- If the EUT is a tabletop system, a rotatable table with 1.5 m height is used.
      --- If the EUT is a floor standing device, it is placed on the ground plane with
      insulation between both.
      --- Auxiliary equipment and cables were positioned to simulate normal
      operation conditions
      --- The AC power port of the EUT (if available) is connected to a power outlet below
      the turntable.
      --- The measurement distance is 1 meter.
      --- The EUT was set into operation.

      Pre measurement:

      --- The antenna is moved spherical over the EUT in different polarisations of
      the antenna.

      Final measurement:

      --- The final measurement will be performed at the position and antenna orientation
      for all detected emissions that were found during the premeasurements with Peak and
      Average detector.
      --- The final levels, frequency, measuring time, bandwidth, correction factor, margin
      to the limit and limit will be recorded. Also a plot with the graph of the
      premeasurement and the limit will be stored.




FCC ID: PADWF126                                                                                                    Page 14 / 15
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services (Shenzhen) Inc.


                                                                                                  Report No.: C180620Z02-RP1


TEST RESULTS
Above 1 GHz
GFSK
Test Mode: TX(2457MHz)                                                                            Tested by: Fade Zhong
 Ambient temperature: 24°C Relative humidity: 52% RH                                                 Date: Apr 21,2018
                                     Correction                                                             Antenna
 Frequency           Reading                             Result            Limit            Margin
                                       Factor                                                                 Pole           Remark
   (MHz)              (dBuV)                           (dBuV/m)          (dBuV/m )           (dB)
                                       (dB/m)                                                                (V/H)
     1291             44.22             -4.85            39.37               74             -34.63             V               peak
     2159             43.63             -2.14            41.49               74             -32.51             V               peak
     4914             43.75              1.33            45.08               74             -28.92             V               peak
     7371             42.82              4.17            46.99               74             -27.01             V               peak

     1207             43.68             -5.62            38.06               74             -35.94              H              peak
     2073             44.23             -3.49            40.74               74             -33.26              H              peak
     4914             46.34              1.38            47.72               74             -26.28              H              peak
     7371             42.80              4.25            47.05               74             -26.95              H              peak

Remark:
1.       Measuring frequencies from 1 GHz to the 10th harmonic of highest fundamental frequency.
2.       Measurements above show only up to 6 maximum emissions noted, or would be lesser if
         no specific emissions from the EUT are recorded (ie: margin>20dB from the applicable
         limit) and considered that's already beyond the background noise floor.
3.       Radiated emissions measured in frequency above 1000MHz were made with an
         instrument using Peak detector mode and average detector mode of the emission shown
         in Actual FS column.
4.       Spectrum setting:
         a. Peak Setting 1GHz - 26GHz, RBW = 1MHz, VBW = 3MHz, Sweep time = auto.
         b. AV Setting 1GH z- 26GHz, RBW = 1MHz, VBW = 10Hz, Sweep time = auto.
5.       Frequency (MHz).             = Emission frequency in MHz
         Reading (dBμV/m)             = Uncorrected Analyzer / Receiver Reading
         Correction Factor (dB)       = Antenna factor + Cable loss – Amplifier gain
         Limit (dBμV/m)               = Limit stated in standard
         Margin (dB)                  = Result (dBμV/m)- Limit (dBμV/m)
         Peak                         =Peak Reading
         AVG.                         =Average Reading
         Remark                       = Mark Peak Reading or Average Reading




FCC ID: PADWF126                                                                                                         Page 15 / 15
     This report shall not be reproduced except in full, without the written approval of Compliance Certification Services (Shenzhen) Inc.



Document Created: 2018-07-03 16:55:04
Document Modified: 2018-07-03 16:55:04

© 2024 FCC.report