Test Report ANT

FCC ID: PADWF125

Test Report

Download: PDF
FCCID_3841333

                  Shenzhen GTI Technology Co., Ltd.
1F,2 Block, Jiaquan Building, Guanlan High—tech Park Baoan District,
Shenzhen, Guangdong, China.
Tel: +86—755— 27521059
Fax: +86—755— 27521011



                               TEST REPORT
  Product Name .......................... : GEMNFC


  Trademark .....................l2222kkk2, :   N.A


  Model/Type reference .............. : GEMNFCO2


  Listed Model(s) ........................ : N.A


  @7&o | » ooo e : —PADWF125

                                             FCC Part 15.249;: Operation within the bands 902—928
  Test Standards ......................... s MHz, 2400—2483.5 MHz and 5725—5850 MHz


  Report No                                     GTI120180533F—2


  ApPPIICANT .. .. ... .. .2 c00sknerre e aakakkks. : Wahoo Fitness L.L.C.


  Address of applicant ............... : 90 W WIEUCA RD NE STE 110 ATLANTA GA 30342


  Date of Receipt ........................ :    Mar.18, 2018


  Date of Test Date...................... :     Mar. 18, 2018— Apr 06, 2018


  Data of issue. ......................2.... : Apr 07, 2018




                       Test result                                                         Pass *
  * In the configuration tested, the EUT complied with the standards specified above




                                     Shenzhen General Testing & Inspection Technology Co., Ltd.
                  1F, 2 Block, Jiaquan Building, Guanlan High—tech Park Baoan District, Shenzhen, Guangdong, China
                           Tel.: (86)755—27521059     Fax: (86)755—27521011     Http:/www.sz—ctc.com.cn


                                                     Page 2 of 24                          Report No.: GTI20180533F-2




                                        GENERAL DESCRIPTION OF EUT
        Equipment:                        GEMNFC
        Model Name:                       GEMNFC02
        Adding Model(s):                  N.A.
        Model difference:                 N.A.
        Manufacturer:                     Wahoo Fitness L.L.C.
        Manufacturer Address:             90 W WIEUCA RD NE STE 110 ATLANTA GA 30342
        Factory:                          Flextronics Electronics Technology (Suzhou) Co., Ltd.
                                          No.268 Suhong Road, Suzhou Industrial Park, Suzhou City,
        Address:
                                          Jiangsu Province, China
        Power Rating:                     DC 5V(from USB port)



                                 Compiled By:               :

                                                                       (Zaki Zhang)


                                 Reviewed By:               :

                                                                        (Gavin Shi)

                                                                      $英文检测章$
                                 Approved By:               :
                                                                       $Walter$

                                                                       (Walter Chen)


This test report may be duplicated completely for legal use with the approval of the applicant. It should not be
reproduced except in full, without the written approval of our laboratory. The client should not use it to claim
product endorsement by GTI. The test results in the report only apply to the tested sample. The test report shall
be invalid without all the signatures of testing engineers, reviewer and approver. Any objections must be raised to
GTI within 15 days since the date when the report is received. It will not be taken into consideration beyond this
limit.




                                    Shenzhen General Testing & Inspection Technology Co., Ltd.
                 1F, 2 Block, Jiaquan Building, Guanlan High-tech Park Baoan District, Shenzhen, Guangdong, China
                          Tel.: (86)755-27521059     Fax: (86)755-27521011     Http://www.sz-ctc.com.cn


                                                                             Page 3 of 24                                           Report No.: GTI20180533F-2



                                                                       Table of Contents                                                                                      Page
1.     SUMMARY................................................................................................................................................................ 4
     1.1.     TEST STANDARDS.......................................................................................................................................................... 4
     1.2.     TEST DESCRIPTION........................................................................................................................................................ 4
     1.3.     TEST FACILITY .............................................................................................................................................................. 5
     1.4.     MEASUREMENT UNCERTAINTY ........................................................................................................................................ 5
2.     GENERAL INFORMATION .......................................................................................................................................... 6
     2.1.     GENERAL DESCRIPTION OF EUT ...................................................................................................................................... 6
     2.2.     DESCRIPTION OF TEST MODES ........................................................................................................................................ 7
     2.3.     MEASUREMENT INSTRUMENTS LIST ................................................................................................................................. 8
7.     TEST CONDITIONS AND RESULTS .............................................................................................................................. 9
     7.1.     CONDUCTED EMISSION MEASUREMENT................................................................................................................. 9
     7.2.     RADIATED EMISSION ................................................................................................................................................... 13
     7.3.     20DB BANDWIDTH ..................................................................................................................................................... 17
     7.4.     BAND EDGE TEST TEST................................................................................................................................................. 19
     7.5.     ANTENNA REQUIREMENT ............................................................................................................................................. 21
8.     EUT TEST PHOTO .................................................................................................................................................... 22
9.     PHOTOGRAPHS OF EUT CONSTRUCTIONAL ............................................................................................................ 24




                                                    Shenzhen General Testing & Inspection Technology Co., Ltd.
                         1F, 2 Block, Jiaquan Building, Guanlan High-tech Park Baoan District, Shenzhen, Guangdong, China
                                      Tel.: (86)755-27521059                Fax: (86)755-27521011                  Http://www.sz-ctc.com.cn


                                                   Page 4 of 24                          Report No.: GTI20180533F-2


1. SUMMARY
1.1. Test Standards
The tests were performed according to following standards:
FCC Rules Part 15.249: Frequency Hopping, Direct Spread Spectrum and Hybrid Systems that are in
operation within the bands of 902-928 MHz, 2400-2483.5 MHz, and 5725-5850 MHz
ANSI C63.10-2013: American National Standard for Testing Unlicensed Wireless Devices

1.2. Test Description
    FCC PART 15 15.249
    FCC Part 15.207                                     AC Power Conducted Emission                               PASS
    FCC Part 15.249 (a) (d)
                                                        Radiated Emissions                                        PASS
    /15.209
    FCC Part 15.249 (a)                                 Spurious RF Conducted Emission                            N/A
    FCC Part 15.215(c)                                  20dB Occupied Band Width                                  PASS
    FCC Part 15.249 (d)                                 Band edge Test                                            PASS
    FCC Part 15.203                            Antenna requirement                                                PASS
    .Note 1:EUT is battery power supply. conducted emission is not need




                                  Shenzhen General Testing & Inspection Technology Co., Ltd.
               1F, 2 Block, Jiaquan Building, Guanlan High-tech Park Baoan District, Shenzhen, Guangdong, China
                        Tel.: (86)755-27521059    Fax: (86)755-27521011      Http://www.sz-ctc.com.cn


(                                                   Page 5 of 24                          Report No.: GTI20180533F—2
    Nee k/


1.3. Test Facility
1.3.1 Address of the test laboratory
Shenzhen General Testing & Inspection Technology Co., Ltd.
Add: 1F, 2 Block,Jiaquan Building, Guanlan High—tech Park Baoan District, Shenzhen,
      Guangdong, China

1.3.2 Laboratory accreditation

The test facility is recognized, certified, or accredited by the following organizations:

IC Registration No.: 9783A
The 3m alternate test site of Shenzhen GTI Technology Co., Ltd.EMC Laboratory has been registered
by Certification and Engineer Bureau of Industry Canada for the performance of with Registration NO.:
9783A on Jan, 2016.

FCC—Registration No.: 951311
Shenzhen GTI Technology Co., Ltd. EMC Laboratory has been registered and fully described in a
report filed with the (FCC) Federal Communications Commission. The acceptance letter from the FCC
is maintained in our files. Registration 951311, Aug 26, 2017

1.4.Measurement Uncertainty
The data and results referenced in this document are true and accurate. The reader is cautioned that
there may be errors within the calibration limits of the equipment and facilities. The measurement
uncertainty was calculated for all measurements listed in this test report acc. to CISPR 16 — 4
Specification for radio disturbance and immunity measuring apparatus and methods — Part 4:
Uncertainty in EMC Measurements             and is documented in the Shenzhen General Testing &
Inspection Technology Co., Ltd quality system ace. to DIN EN ISO/IEC 17025. Furthermore,
component and process variability of devices similar to that tested may result in additional deviation.
The manufacturer has the sole responsibility of continued compliance of the device.
Hereafter the best measurement capability for General Testing & Inspection laboratory is reported:
                         Test Items                                         Measurement Uncertainty                Notes

Transmitter power conducted                                                              0.57 dB                    (1)
Transmitter power Radiated                                                               2.20 dB                    (1)
Conducted spurious emission 9KHz—40 GHz                                                  1.60 dB                    (1)
Radiated spurious emission 9KHz—40 GHz                                                   2.20 dB                    (1)
Conducted Emission 9KHz—30MHz                                                            3.39 dB                    (1)
Radiated Emission      —30~1000MHz                                                       4.24 dB                    (1)

Radiated Emission 1~18GHz                                                                5.16 dB                    (1)
Radiated Emission 18—40GHz                                                               5.54 dB                    (1)
Occupied Bandwidth                                                                       o=—==—————                 (1)
(1) This uncertainty represents an expanded uncertainty expressed at approximately the 95%
confidence level using a coverage factor of k=1.96.


                                   Shenzhen General Testing & Inspection Technology Co., Ltd.
                1F, 2 Block, Jiaquan Building, Guanlan High—tech Park Baoan District, Shenzhen, Guangdong, China
                         Tel.: (86)755—27521059    Fax: (86)755—27521011      Http:/www.sz—ctc.com.cn


                                                    Page 6 of 24                          Report No.: GTI20180533F-2


2. GENERAL INFORMATION
2.1. General Description of EUT
 Product Name:                     GEMNFC
 Model/Type reference:             GEMNFC02
 Power supply:                     DC 5V(from USB port)
 Hardware version:                 V1.0
 Software version:                 V1.0
 Bluetooth:
 Supported type:                   Version 4.0 for low Energy
 Modulation:                       GFSK
 Operation frequency:              2402MHz to 2480MHz

 Channel number:                   40
 Channel separation:               2 MHz
 Antenna type:                     Ceramic Antenna
 Antenna gain:                     4.17dBi
 ANT+:
 Supported type:                   ANT+
 Modulation:                       GFSK
 Operation frequency:              2457MHz
 Channel number:                   1
 Channel separation:               /
 Antenna type:                     Ceramic Antenna
 Antenna gain:                 4.17dBi
Note: For a more detailed features description, please refer to the manufacturer’s specifications or the
User's Manual.




                                   Shenzhen General Testing & Inspection Technology Co., Ltd.
                1F, 2 Block, Jiaquan Building, Guanlan High-tech Park Baoan District, Shenzhen, Guangdong, China
                         Tel.: (86)755-27521059    Fax: (86)755-27521011      Http://www.sz-ctc.com.cn


                                                     Page 7 of 24                          Report No.: GTI20180533F-2



2.2. Description of Test Modes
Peripherals Devices:
      Name:                     Model:                    Serial               Manufacture                     Remark
      Laptop                   Thinkpad                     /                    Lenovo                          /

Note: All the above equipment /cable were placed in worse case position to maximize emission signals during
emission test.


Operation Frequency
The Applicant provides communication tools software to control the EUT for staying in continuous
transmitting (Duty Cycle more than 98%) mode for testing.
ANT+
                     Channel                                       Frequency (MHz)
                        01                                               2457




                                    Shenzhen General Testing & Inspection Technology Co., Ltd.
                 1F, 2 Block, Jiaquan Building, Guanlan High-tech Park Baoan District, Shenzhen, Guangdong, China
                          Tel.: (86)755-27521059    Fax: (86)755-27521011      Http://www.sz-ctc.com.cn


                                                    Page 8 of 24                          Report No.: GTI20180533F-2



 2.3. Measurement Instruments List
Maximum Peak Output Power / Band Edge Compliance of RF Emission / Spurious RF Conducted
Emission /Hoping Require/ 20dB bandwidth
                                                                                 Calibrated
 Item      Test Equipment         Manufacturer    Model No.       Serial No.
                                                                                    until
   1     Spectrum Analyzer     Rohde & Schwarz      FSU            100105       Jan. 04,2019
   2         RF Cable                     Schwarzbeck                 AH32D4                 SF0150                Jan. 04,2019
         Temporary Antenna
   3                                      Schwarzbeck                 SMA24D                ED1201                 Jan. 04,2019
            connector
Note: The temporary antenna connector is soldered on the PCB board in order to perform conducted tests and
this temporary antenna connector is listed in the equipment list.
 3.
Conducted Emission
 Item       Test Equipment                Manufacturer                Model No.             Serial No.             Calibrate until
   1             LISN                             R&S                  ENV216                   101112             Jan. 04,2019
   2             LISN                             R&S                  ENV216                   101113             Jan. 04,2019
   3      EMI Test Receiver                       R&S                    ESCI                   100920             Jan. 04,2019
   4             Cable                    Schwarzbeck                 AK9515E                   33156              Jan. 04,2019
4.
Radiated Emission
                                                                                                                    Calibrated
Item         Test Equipment                Manufacturer                Model No.                Serial No.
                                                                                                                       until
  1        EMI Test Receiver                      R&S                      ESCI                  100967            Jan. 04,2019
  2          High pass filter              micro-tranics              HPM50111                   34202             Jan. 04,2019
  3        Log-Bicon Antenna               Schwarzbeck                 CBL6141A                   4180             Jan. 04,2019
            Ultra-Broadband
  4                                         ShwarzBeck                 BBHA9170                  25841             Jan. 04,2019
                Antenna
  5          Loop Antenna                      LAPLAC                    RF300                    9138             Jan. 04,2019
  6       Spectrum Analyzer            Rohde & Schwarz                   FSU                    100105             Jan. 04,2019
                                                                         BBHA
  7           Horn Antenna                 Schwarzbeck                                             648             Jan. 04,2019
                                                                         9120D
  8           Pre-Amplifier                        HP                    8447D              1937A03050             Jan. 04,2019
                                                                       EMC05183
   9         Pre-Amplifier                        EMCI                                           980075            Jan. 04,2019
                                                                           5
  10         Antenna Mast                          UC                   UC3000                     N/A                   N/A
  11          Turn Table                           UC                   UC3000                     N/A                   N/A
  12      Cable Below 1GHz                Schwarzbeck                AK9515E                    33155              Jan. 04,2019
                                                                    SUCOFLEX1
  13      Cable Above 1GHz                Hubersuhner                                           DA1580             Jan. 04,2019
                                                                       02
 5. Note: 1. The Cal.Interval was one year.
 6.      2. The cable loss has calculated in test result which connection between each test
 instruments.




                                   Shenzhen General Testing & Inspection Technology Co., Ltd.
                1F, 2 Block, Jiaquan Building, Guanlan High-tech Park Baoan District, Shenzhen, Guangdong, China
                         Tel.: (86)755-27521059    Fax: (86)755-27521011      Http://www.sz-ctc.com.cn


                                                     Page 9 of 24                          Report No.: GTI20180533F-2



7. TEST CONDITIONS AND RESULTS
7.1. CONDUCTED EMISSION MEASUREMENT
Limit

     POWER LINE CONDUCTED EMISSION                                 (Frequency Range 150KHz-30MHz)


       FREQUENCY (MHz)
                                              Quasi-peak                                     Average
            0.15 -0.5                           66 - 56 *                                    56 - 46 *
            0.50 -5.0                              56.00                                         46.00
            5.0 -30.0                              60.00                                         50.00
          Note:
            (1) The tighter limit applies at the band edges.
            (2) The limit of " * " marked band means the limitation decreases linearly with the
                logarithm of the frequency in the range.


 The following table is the setting of the receiver
               Receiver Parameters                                                        Setting
                    Attenuation                                                            10 dB
                  Start Frequency                                                        0.15 MHz
                  Stop Frequency                                                          30 MHz
                   IF Bandwidth                                                            9 kHz


Test Procedure
1.    The EUT was placed 0.8 meters from the horizontal ground plane with EUT being connected to
      the power mains through a line impedance stabilization network (LISN). All other support
      equipments powered from additional LISN(s). The LISN provide 50 Ohm/ 50uH of coupling
      impedance for the measuring instrument.
2.    Interconnecting cables that hang closer than 40 cm to the ground plane shall be folded back and
      forth in the center forming a bundle 30 to 40 cm long.
3.    I/O cables that are not connected to a peripheral shall be bundled in the center. The end of the
      cable may be terminated, if required, using the correct terminating impedance. The overall length
      shall not exceed 1 m.Repeat above procedures until all frequency measurements have been
      completed.
4.    LISN at least 80 cm from nearest part of EUT chassis.
5.    For the actual test configuration, please refer to the related Item –EUT Test Photos.

Test Configuration
For the actual test configuration, please refer to the related Item –EUT Test Photos.




                                    Shenzhen General Testing & Inspection Technology Co., Ltd.
                 1F, 2 Block, Jiaquan Building, Guanlan High-tech Park Baoan District, Shenzhen, Guangdong, China
                          Tel.: (86)755-27521059    Fax: (86)755-27521011      Http://www.sz-ctc.com.cn


                                                   Page 10 of 24                          Report No.: GTI20180533F-2




Test Results




                                  Shenzhen General Testing & Inspection Technology Co., Ltd.
               1F, 2 Block, Jiaquan Building, Guanlan High-tech Park Baoan District, Shenzhen, Guangdong, China
                        Tel.: (86)755-27521059    Fax: (86)755-27521011      Http://www.sz-ctc.com.cn


                                                              Page 11 of 24                                Report No.: GTI20180533F—2



 TEST RESULTS
Temperature :                    21 °C                                     Relative Humidity : |60%
Pressure :                       101 Kpa                                   Test Date :         2018—03—25
Test Mode :                      Mode 1                                    Phase :             L
Test Voltage                     AC 120V/60H2z

  Voltage with 2—Line—LISN
         Level in dBp W




                                                                                                   ECC Par 15 Clats B_OP

                                                                                                   FeC Par 15 Class B_AV



                                                                                                                     *#




                                                                    7M     3M     4M 5M 600      8 10M         20M
                                                               Frequency in Hz




  Final Measurement Detector 1
    Frequency                QuasiPeak       Meas. Time      Bandwidth      Filter     Line       Corm     Margin         Limit   Comment
      (MHz)                    (dBuy)           ims)            (kHz)                             (dB)       (dB)         [fiu

     0.154500                        45.6       1000.000           ©.000    Off        L1          10.0       20.2         65.8
     0.334500                        37 .6      1000.000           ©.000    Off        L1           90        21.7         59.3
    23.235000                        36.0       1000.000           9.000    Off        L1          10.0       24.0         60.0


  Final Measurement Detector 2
    Frequency                 Average        Meas. Time      Bandwidth      Filter     Line       Cort     Margin         Limit   Comment
      (MHz)                    (dBuV)           ims)           (kHz)                                L       (dB)           (dB
                                                                                                  (dB)                    L¥A
     0.334500                       30.9       1000.000            9.000    Off        L1          9. 9        18.4       49.3
    22.393500                       20.3       1000.000            9.000    Off        L1         10.0         29.7       50.0
    23.239500                       20.1       1000.000            $.000    Off        L1         10.0         29.9       50.0




                                             Shenzhen General Testing & Inspection Technology Co., Ltd.
                          1F, 2 Block, Jiaquan Building, Guanlan High—tech Park Baoan District, Shenzhen, Guangdong, China
                                   Tel.: (86)755—27521059    Fax: (86)755—27521011            Http:/www.sz—ctc.com.cn


                                               Page 12 of 24                          Report No.: GTI20180533F-2



Temperature:      21 ℃                                     Relative Humidity: 60%
Pressure:         101 Kpa                                  Test Date :        2018-03-25
Test Mode:        Mode 1                                   Phase :            N
Test Voltage :    AC 120V/60Hz




                              Shenzhen General Testing & Inspection Technology Co., Ltd.
           1F, 2 Block, Jiaquan Building, Guanlan High-tech Park Baoan District, Shenzhen, Guangdong, China
                    Tel.: (86)755-27521059    Fax: (86)755-27521011      Http://www.sz-ctc.com.cn


(                                                        Page 13 of 24                          Report No.: GTI20180533F—2


7.2.Radiated Emission
Limit
For intentional device, according to§ 15.209(a), § 15.249(a), the general requirement of field strength
of radiated emission from intentional radiators at a distance of 3 meters shall not exceed the following
table.
The frequency spectrum above 1 GHz for Transmitter was investigated. All emission not reported are
much lower than the prescribed limits. Set the RBW=1MHz, VBW=3MHz for Peak Detector while the
RBW=1MHz, VBW=10Hz for Average Detector, Readings are both peak and average values. The
pre—test have done for the EUT in three axes and found the worst emission at position shown in test
setup photos.
      Frequency (MHz)          Distance (Meters)                       Radiated (dBuV/m)                       Radiated (uV/m)
         0.009—0.49                       3                  20l0g(2400/F (KHz))+40l10g(300/3)                   2400/F (KHz)
         0.49—1.705                       3                  2010g(24000/F(KHz))+ 4010g(30/3)                   24000/F (KHz)
          1.705—30                        3                         2010g(30)+ 4010g(30/3)                             30
            30—88                         3                                      40.0                                  100
           88—216                         3                                      43.5                                  150
          216—960                         3                                      46.0                                  200
         Above 960                        3                                      54.0                                  500
Test Procedure
1.     The EUT was placed on a turn table which is 0.8m(below 1GHz)or1.5m(above 1GHz) above
       ground plane.
6.     Maximum procedure was performed by raising the receiving antenna from 1m to 4m and rotating
       the turn table from 0°C to 360°C to acquire the highest emissions from EUT
7.     And also, each emission was to be maximized by changing the polarization of receiving antenna
       both horizontal and vertical.
8.     Repeat above procedures until all frequency measurements have been completed.
Field Strength Calculation
     The field strength is calculated by adding the Antenna Factor and Cable Factor and subtracting the
     Amplifier Gain and Duty Cycle Correction Factor (if any) from the measured reading. The basic equation with
     a sample calculation is as follows:
                                                      FS = RA + AF + CL — AG
        Where       __FS = Field Strength                              CL = Cable Attenuation Factor (Cable Loss)
                    RA = Reading Amplitude                             AG = Amplifier Gain
                  AF = Antenna Factor

     For example
       Frequency                   FS                   RA             AF         CL                AG            Transd
           (MHz)                (dBuV/m)              (dBpuV/m)        (dB)       (dB)              (dB)          (dB)
         150.00                 40                      58.1           12.2       1.6               31.90         —18.1

     Transd=AF +CL—AG

Test Configuration

For the actual test configuration, please refer to the related Item —EUT Test Photos.

                                       Shenzhen General Testing & Inspection Technology Co., Ltd.
                    1F, 2 Block, Jiaquan Building, Guanlan High—tech Park Baoan District, Shenzhen, Guangdong, China
                             Tel.: (86)755—27521059      Fax: (86)755—27521011    Http:/www.sz—ctc.com.cn


                                                   Page 14 of 24                          Report No.: GTI20180533F-2

                                       Frequency range 9 KHz – 30MHz




                                    Frequency range 30MHz – 1000MHz




                                   Frequency range above 1GHz-25GHz




Test Results

Remark:


 For 9 KHz-30MHz
   The test results of 9kHz-30MHz is attenuated more than 20dB below the permissible limits, so the
   results don't record in the report.



                                  Shenzhen General Testing & Inspection Technology Co., Ltd.
               1F, 2 Block, Jiaquan Building, Guanlan High-tech Park Baoan District, Shenzhen, Guangdong, China
                        Tel.: (86)755-27521059    Fax: (86)755-27521011      Http://www.sz-ctc.com.cn


                                               Page 15 of 24                          Report No.: GTI20180533F-2

For 30MHz-1GHz
                                                   Horizontal




                              Shenzhen General Testing & Inspection Technology Co., Ltd.
           1F, 2 Block, Jiaquan Building, Guanlan High-tech Park Baoan District, Shenzhen, Guangdong, China
                    Tel.: (86)755-27521059    Fax: (86)755-27521011      Http://www.sz-ctc.com.cn


                                                 Page 16 of 24                          Report No.: GTI20180533F-2

                                                       Vertical




         Frequenc     Meter       Pre-amplif      Cable       Antenna      Emission          Limits     Margin
 Polar       y       Reading          ier         Loss         Factor        Level                               Detector
 (H/V)     (MHz)     (dBuV)          (dB           (dB)        (dB/m)      (dBuV/m)      (dBuV/m)        (dB)     Type
  H        2457       86.11         36.2          4.25          30.1        84.26            114       -29.74      PK
  H        2457       74.69         36.2          4.25          30.1        72.84            94        -21.16      AV
  V        2457       88.65         36.2          4.25          30.1        86.80            114       -27.20      PK
  V        2457       76.14         36.2          4.25          30.1        74.29            94        -19.71      AV


REMARKS:
      1.   Emission level (dBuV/m) =Raw Value (dBuV)+Correction Factor (dB/m)
      2.   Correction Factor (dB/m) = Antenna Factor (dB/m)+Cable Factor (dB)-Pre-amplifier Factor
      3.   Margin value = Limit value- Emission level.
      4.   -- Mean the PK detector measured value is below average limit.
      5.   The other emission levels were very low against the limit.

           Above 1GHz emission please refer to C180406Z02-RP1 report




                                Shenzhen General Testing & Inspection Technology Co., Ltd.
             1F, 2 Block, Jiaquan Building, Guanlan High-tech Park Baoan District, Shenzhen, Guangdong, China
                      Tel.: (86)755-27521059    Fax: (86)755-27521011      Http://www.sz-ctc.com.cn


                                                    Page 17 of 24                          Report No.: GTI20180533F-2




7.3. 20dB Bandwidth
Limit
unwanted emissions outside of the frequency bands shown in these alternative provisions must be
attenuated to the emission limits shown in §15.209.
Test Procedure
1.   The transmitter output was connected to the spectrum analyzer.
2.   Set SA as follow:
     a) RBW: 100 kHz.
     b) VBW: ≥ 3 × RBW.
     c) Detector: Peak.
     d) Trace mode: max hold.
     e) Sweep: auto couple.
3.   Allow the trace to stabilize.
4.   Measure the maximum width of the emission that is constrained by the frequencies associated
     with the two outermost amplitude points (upper and lower frequencies) that are attenuated by 6 dB
     relative to the maximum level measured in the fundamental emission.

Test Configuration


                  EUT                                              SPECTRUM
                                                                   ANALYZER

Test Results

                                                          ANT+
                                                                                     99%
                                                    20dB Bandwidth
             Type              Channel                                            Bandwidth              Result
                                                        (MHz)
                                                                                    (MHz)
             GFSK                  00                      1.1016                    0.9952               Pass
Test plot as follows:




                                   Shenzhen General Testing & Inspection Technology Co., Ltd.
                1F, 2 Block, Jiaquan Building, Guanlan High-tech Park Baoan District, Shenzhen, Guangdong, China
                         Tel.: (86)755-27521059    Fax: (86)755-27521011      Http://www.sz-ctc.com.cn


                                                      Page 18 of 24                                                   Report No.: GTI20180533F-2

                                                                          * RBW     100 kHz         Marker 1 [T1 ]
                                                                          * VBW     300 kHz                      -7.05 dBm
                 Ref        20 dBm              * Att      20 dB              SWT   10 ms                 2.456983200 GHz

                  20       Offset     0.5 dB                                                        ndB [T1]     20.00 dB
                                                                                                    BW    1.101600000 MHz
        UNCAL                                                                                       Temp 1 [T1 ndB]                 A
                  10
                                                                                                                -26.90 dBm
        1 RM *                                                                                            2.456433600 GHz
        MAXH
                  0                                                                                 Temp 2 [T1 ndB]
                                                                      1                                         -27.12 dBm LVL
                                                                                                          2.457535200 GHz
                  -10




                  -20
                                                 T1                                           T2


                  -30




                  -40




                  -50




                  -60




                  -70



                  -80

                 Center       2.457 GHz                            300 kHz/                                     Span    3 MHz




       Date:                17.NOV.2017    20:22:12

                                                                          * RBW     100 kHz         Marker 1 [T1 ]
                                                                          * VBW     300 kHz                    -13.73 dBm
                  Ref        10 dBm             * Att      10 dB              SWT 2.5 ms                 2.457028846 GHz

                      10                                                                            OBW995.192307692 kHz
                                                                                                    Temp 1 [T1 OBW]
          UNCAL                                                                                                -29.04 dBm       A
                      0
                                                                                                         2.456495192 GHz
          1 PK                                                                                      Temp 2 [T1 OBW]
          MAXH
                      -10                                                 1                                    -28.91 dBm
                                                                                                         2.457490385 GHz


                      -20

                                                      T1                                    T2

                      -30




                      -40




                      -50




                      -60




                      -70




                      -80



                      -90

                   Center      2.457 GHz                           300 kHz/                                    Span    3 MHz




         Date:               1.JAN.2000    00:57:02




                             Shenzhen General Testing & Inspection Technology Co., Ltd.
1F, 2 Block, Jiaquan Building, Guanlan High-tech Park Baoan District, Shenzhen, Guangdong, China
         Tel.: (86)755-27521059                   Fax: (86)755-27521011                            Http://www.sz-ctc.com.cn


                                                   Page 19 of 24                          Report No.: GTI20180533F-2


7.4. Band edge Test Test
Limit
For intentional device, according to§ 15.249(d), Emissions radiated outside of the specified frequency
bands, except for harmonics, shall be attenuated by at least 50 dB below the level of the fundamental
or to the general radiated emission limits in 15.209, whichever is the lesser attenuation.
Test Procedure
The frequency spectrum above 1 GHz for Transmitter was investigated. All emission not reported are
much lower than the prescribed limits. Set the RBW=1MHz, VBW=3MHz for Peak Detector while the
RBW=1MHz, VBW=10Hz for Average Detector, Readings are both peak and average values. The
pre-test have done for the EUT in three axes and found the worst emission at position shown in test
setup photos.
1. The EUT was placed on a turn table which is 0.8m(below 1GHz)or1.5m(above 1GHz) above
    ground plane
2. . The table was rotated 360 degrees to determine the position of the highest radiation.
3. The EUT was set 3 meters away from the interference receiving antenna, which was mounted on
    the top of a variable height antenna tower.
4. The antenna height is varied from one meter to four meters above the ground to determine the
    maximum value of the field strength. Both horizontal and vertical polarizations of the antenna are
    set to make the measurement.
5. For each suspected emission, the EUT was arranged to its worst case and then the antenna was
    tuned to heights from 1 meter to 4 meters and the rotatable table was turned from 0 degrees to 360
    degrees to find the maximum reading.
6. The test-receiver system was set to Peak Detect Function and Specified Bandwidth with Maximum
    Hold Mode.
7. Place a marker at the end of the restricted band closest to the transmit frequency to show
    compliance. Also measure any emissions in the restricted bands. Save the spectrum analyzer plot.
    Repeat for each power and modulation for lowest and highest channel
8. Test the EUT in the lowest channel, the highest channel
9. The radiation measurements are performed in X, Y, Z axis positioning. And found the X axis
    positioning which it is worse case, only the test worst case mode is recorded in the report.
10. Repeat above procedures until all frequencies measured was complete.
Field Strength Calculation
 The field strength is calculated by adding the Antenna Factor and Cable Factor and subtracting the
 Amplifier Gain and Duty Cycle Correction Factor (if any) from the measured reading. The basic equation with
 a sample calculation is as follows:
                                          FS = RA + AF + CL – AG
    Where FS = Field Strength                                CL = Cable Attenuation Factor (Cable Loss)
               RA = Reading Amplitude                        AG = Amplifier Gain
               AF = Antenna Factor

 For example
   Frequency                  FS                RA               AF         CL                 AG           Transd
       (MHz)               (dBμV/m)           (dBμV/m)           (dB)       (dB)               (dB)         (dB)
     150.00                40                   58.1             12.2       1.6                31.90        -18.1

 Transd=AF +CL-AG
Test Configuration
For the actual test configuration, please refer to the related Item –EUT Test Photos.

                                  Shenzhen General Testing & Inspection Technology Co., Ltd.
               1F, 2 Block, Jiaquan Building, Guanlan High-tech Park Baoan District, Shenzhen, Guangdong, China
                        Tel.: (86)755-27521059    Fax: (86)755-27521011      Http://www.sz-ctc.com.cn


                                                   Page 20 of 24                          Report No.: GTI20180533F-2

                                    Frequency range 30MHz – 1000MHz




                                   Frequency range above 1GHz-25GHz




Test Results

Remark:

                                                           2457MHz
          Frequenc      Meter       Pre-amplif      Cable       Antenna      Emission
 Polar                                                                                         Limits     Margin   Detector
              y        Reading          ier         Loss         Factor       Level
 (H/V)     (MHz)        (dBuV)         (dB          (dB)         (dB/m)      (dBuV/m)      (dBuV/m)        (dB)     Type
   H       2390         47.49         36.12         3.32          27.5        42.19             74       -31.81      PK
   H       2390         36.45         36.12         3.32          27.5        31.15             54       -22.85      AV
   V       2390         49.19         36.12         3.32          27.5        43.89             74       -30.11      PK
   V       2390         35.89         36.12         3.32          27.5        30.59             54       -23.41      AV

                                                           2457MHz
          Frequenc      Meter       Pre-amplif      Cable       Antenna      Emission
 Polar                                                                                         Limits     Margin   Detector
              y        Reading          ier         Loss         Factor        Level
 (H/V)      (MHz)      (dBuV)          (dB           (dB)        (dB/m)      (dBuV/m)      (dBuV/m)        (dB)     Type
   H      2483.5        47.75         36.55         3.38          27.5        42.08             74       -31.92      PK
   H      2483.5        37.33         36.55         3.38          27.5        31.66             54       -22.34      AV
   V      2483.5        46.64         36.55         3.38          27.5        40.97             74       -33.03      PK
   V      2483.5        35.64         36.55         3.38          27.5        29.97             54       -24.03      AV


                                  Shenzhen General Testing & Inspection Technology Co., Ltd.
               1F, 2 Block, Jiaquan Building, Guanlan High-tech Park Baoan District, Shenzhen, Guangdong, China
                        Tel.: (86)755-27521059    Fax: (86)755-27521011      Http://www.sz-ctc.com.cn


                                                   Page 21 of 24                          Report No.: GTI20180533F-2



7.5. Antenna Requirement
Standard Applicable

For intentional device, according to FCC 47 CFR Section 15.203:

An intentional radiator shall be designed to ensure that no antenna other than that furnished by the
responsible party shall be used with the device. The use of a permanently attached antenna or of an
antenna that uses a unique coupling to the intentional radiator, the manufacturer may design the unit
so that a broken antenna can be replaced by the user, but the use of a standard antenna jack or
electrical connector is prohibited

Result

The EUT’s antenna used a Antenna, soldered on the PCB., The antenna’s gain is 4.17dBi. Complying
with the standard requirement.

                                   BT&ANT+
                                  Antenna
Test Result:




                                                                                                                  NFC
                                                                                                                  Antenna




                                  Shenzhen General Testing & Inspection Technology Co., Ltd.
               1F, 2 Block, Jiaquan Building, Guanlan High-tech Park Baoan District, Shenzhen, Guangdong, China
                        Tel.: (86)755-27521059    Fax: (86)755-27521011      Http://www.sz-ctc.com.cn


                                           Page 22 of 24                           Report No.: GTI20180533F—2


8. EUT TEST PHOTO
                                         Conducted Emission




                                                                                                                o
                                                                                                                * pyc
                                                        TL7
                       1=|-fl
                           ’@r                                                                 i




                          Shenzhen General Testing & Inspection Technology Co., Ltd.
       1F, 2 Block, Jiaquan Building, Guanlan High—tech Park Baoan District, Shenzhen, Guangdong, China
                Tel.: (86)755—27521059    Fax: (86)755—27521011      Http:/www.sz—ctc.com.cn


                                    Page 23 of 24                          Report No.: GTI20180533F-2




                   Shenzhen General Testing & Inspection Technology Co., Ltd.
1F, 2 Block, Jiaquan Building, Guanlan High-tech Park Baoan District, Shenzhen, Guangdong, China
         Tel.: (86)755-27521059    Fax: (86)755-27521011      Http://www.sz-ctc.com.cn


                                           Page 24 of 24                          Report No.: GTI20180533F-2



9. PHOTOGRAPHS OF EUT CONSTRUCTIONAL
                Please reference to the test report No.: GTI20180533F-1


              **********************THE END**********************




                          Shenzhen General Testing & Inspection Technology Co., Ltd.
       1F, 2 Block, Jiaquan Building, Guanlan High-tech Park Baoan District, Shenzhen, Guangdong, China
                Tel.: (86)755-27521059    Fax: (86)755-27521011      Http://www.sz-ctc.com.cn



Document Created: 2018-04-28 16:05:11
Document Modified: 2018-04-28 16:05:11

© 2025 FCC.report
This site is not affiliated with or endorsed by the FCC