test report

FCC ID: PADWF120

Test Report

Download: PDF
FCCID_4446132

                      CTC Laboratories, Inc.
1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
Tel: +86-755- 27521059 Fax: +86-755- 27521011 Http://www.sz-ctc.com.cn



                                            TEST REPORT
 Report No. ····························:     GTI20180934F-2

 FCC ID··································:    PADWF120

 Applicant································:   Wahoo Fitness LLC

 Address·································:    90 W. Wieuca Road #110 Atlanta Georgia 30342 United States
                                              East West Industries Vietnam LLC
 Manufacturer··························:
                                              NO.27, Street No.2, VSIP 2, Hoa Phu Ward, Thu Dau Mot City, Binh
 Address·································:
                                              Duong Province, Vietnam 84, Viet Nam
 Product Name························:        SMART TRAINER

 Trade Mark·····························:     N.A.

 Model/Type reference···············:         WF120

 Listed Model(s) ·······················:     /

 Standard·······························:     FCC Rules Part 15.249
                                              ANSI C63.10-2013

 Date of receipt of test sample…:             2018-10.20

 Date of testing…………………..:                    2018-10.21 to 2019-06.26

 Date of issue…………………....:                    2019.06.27

 Result……………………………:                           PASS

 Compiled by:
 (Printed name+signature)                     Torny Fang

 Supervised by:
 ( Printed name+signature)                    Cary Luo

 Approved by:
 ( Printed name+signature)                    Walter Chen

 Testing Laboratory Name :                    CTC Laboratories, Inc.

 Address      :                               1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park,
                                              Shenzhen, Guangdong, China
 This test report may be duplicated completely for legal use with the approval of the applicant. It should not
 be reproduced except in full, without the written approval of our laboratory. The client should not use it to
 claim product endorsement by CTC. The test results in the report only apply to the tested sample. The
 test report shall be invalid without all the signatures of testing engineers, reviewer and approver.
 Any objections must be raised to CTC within 15 days since the date when the report is received. It will not
 be taken into consideration beyond this limit. The test report merely correspond to the test sample.


                                                                                Page 2 of 27                                          Report No.: GTI20180934F-2



                                                                       Table of Contents                                                                                      Page
1.     TEST SUMMARY.................................................................................................................................................... 3
     1.1.     TEST STANDARDS.......................................................................................................................................................... 3
     1.2.     REPORT VERSION .......................................................................................................................................................... 3
     1.3.     TEST DESCRIPTION ........................................................................................................................................................ 4
     1.4.     TEST FACILITY .............................................................................................................................................................. 5
     1.5.     MEASUREMENT UNCERTAINTY ........................................................................................................................................ 6
     1.6.     ENVIRONMENTAL CONDITIONS ........................................................................................................................................ 6
2.     GENERAL INFORMATION....................................................................................................................................... 7
     2.1.     CLIENT INFORMATION ................................................................................................................................................... 7
     2.2.     GENERAL DESCRIPTION OF EUT ...................................................................................................................................... 7
3.     DESCRIPTION OF TEST MODES .............................................................................................................................. 8
4.     MEASUREMENT INSTRUMENTS LIST ..................................................................................................................... 9
5.     TEST ITEM AND RESULTS ..................................................................................................................................... 11
     5.1.     AC POWER LINE CONDUCTED EMISSIONS ....................................................................................................................... 11
     5.2.     20 DB OCCUPIED BANDWIDTH ..................................................................................................................................... 14
     5.3.     RADIATED FIELD STRENGTH OF THE FUNDAMENTAL SIGNAL .................................................................................................. 16
     5.4.     RADIATED SPURIOUS EMISSIONS AND BANDEDGE EMISSION ............................................................................................... 18
     5.5.     ANTENNA REQUIREMENT ............................................................................................................................................. 25
6.     EUT TEST PHOTOS ............................................................................................................................................... 26
7.     PHOTOGRAPHS OF EUT CONSTRUCTIONAL ......................................................................................................... 27




                                                                               CTC Laboratories, Inc
                               1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
                                    Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                                 For anti-fake verification, please visit the official website of Certification and
                                                                 Accreditation Administration of the People’s Republic of China : yz.cnca.cn


                                                        Page 3 of 27                         Report No.: GTI20180934F-2



 1. TEST SUMMARY
 1.1. Test Standards
The tests were performed according to following standards:

FCC Rules Part 15.249: Operation within the bands 902-928 MHz, 2400-2483.5 MHz, 5725-5875
MHz, and 24.0-24.25 GHz.
ANSI C63.10-2013: American National Standard for Testing Unlicensed Wireless Devices.


 1.2. Report version
     Version No.                      Date of issue                                             Description
          00                           2019.06.27                                                  Original




                                                         CTC Laboratories, Inc
                   1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
                        Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                     For anti-fake verification, please visit the official website of Certification and
                                                     Accreditation Administration of the People’s Republic of China : yz.cnca.cn


                                                         Page 4 of 27                         Report No.: GTI20180934F-2




 1.3. Test Description
                                                                                    RSS-210&
             Test Item                          Section in CFR 47                                         Result          Test Engineer
                                                                                    RSS-Gen
   AC Power Line Conducted
                                                         15.207                      RSS-Gen                 N/A                  N/A
         Emissions
   20dB Occupied Bandwidth                          15.215/15.249                    RSS-Gen               PASS              Young He
       Field strength of the                                                          RSS-210
                                                       15.249(a)                                           PASS              Young He
       Fundamental signal                                                             Annex B
                                                                                      RSS-210
       Spurious Emissions                         15.209/15.249(a)                                         PASS              Young He
                                                                                      Annex B
                                                                                      RSS-210
      Band edge Emissions                         15.205/15.249(d)                                         PASS              Young He
                                                                                      Annex B
      Antenna requirement                                15.203                      RSS-Gen               PASS              Young He

Note: The measurement uncertainty is not included in the test result.




                                                          CTC Laboratories, Inc
                    1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
                         Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                      For anti-fake verification, please visit the official website of Certification and
                                                      Accreditation Administration of the People’s Republic of China : yz.cnca.cn


                                                          Page 5 of 27                         Report No.: GTI20180934F-2




 1.4. Test Facility
Address of the report laboratory

CTC Laboratories, Inc.

Add: 1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
Laboratory accreditation

The test facility is recognized, certified, or accredited by the following organizations:

CNAS-Lab Code: L5365

CTC Laboratories, Inc. has been assessed and proved to be in compliance with CNAS-CL01 Accreditation
Criteria for Testing and Calibration Laboratories(identical to ISO/IEC17025: 2005 General Requirements) for the
Competence of Testing and Calibration Laboratories.

A2LA-Lab Cert. No.: CN1208

CTC Laboratories, Inc. EMC Laboratory has been accredited by A2LA for technical competence in the field
of electrical testing, and proved to be in compliance with ISO/IEC 17025:2005 General Requirements for
the Competence of Testing and Calibration Laboratories and any additional program requirements in the
identified field of testing.

IC Registration No.: 9783A

The 3m alternate test site of CTC Laboratories, Inc. EMC Laboratory has been registered by Certification and
Engineer Bureau of Industry Canada for the performance of with Registration NO.: CN0029 on Dec, 2018.

FCC-Registration No.: 951311

CTC Laboratories, Inc. EMC Laboratory has been registered and fully described in a report filed with the (FCC)
Federal Communications Commission. The acceptance letter from the FCC is maintained in our files.
Registration 951311, Aug 26, 2017




                                                           CTC Laboratories, Inc
                     1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
                          Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                       For anti-fake verification, please visit the official website of Certification and
                                                       Accreditation Administration of the People’s Republic of China : yz.cnca.cn


                                                          Page 6 of 27                         Report No.: GTI20180934F-2




  1.5. Measurement Uncertainty
The data and results referenced in this document are true and accurate. The reader is cautioned that there may
be errors within the calibration limits of the equipment and facilities. The measurement uncertainty was
calculated for all measurements listed in this test report acc. to TR-100028-01” Electromagnetic compatibility and
Radio spectrum Matters (ERM);Uncertainties in the measurement of mobile radio equipment characteristics; Part
1” and TR-100028-02 “Electromagnetic compatibility and Radio spectrum Matters (ERM);Uncertainties in the
measurement of mobile radio equipment characteristics; Part 2 “ and is documented in the Shenzhen General
Testing & Inspection Technology Co., Ltd. quality system acc. to DIN EN ISO/IEC 17025. Furthermore,
component and process variability of devices similar to that tested may result in additional deviation. The
manufacturer has the sole responsibility of continued compliance of the device.

Below is the best measurement capability for Shenzhen General Testing & Inspection Technology Co., Ltd.


                       Test Items                                           Measurement Uncertainty                             Notes
Transmitter power conducted                                                               0.42 dB                                 (1)
Transmitter power Radiated                                                                2.14 dB                                 (1)
Conducted spurious emissions 9kHz~40GHz                                                   1.60 dB                                 (1)
Radiated spurious emissions 9kHz~40GHz                                                    2.20 dB                                 (1)
Conducted Emissions 9kHz~30MHz                                                            3.20 dB                                 (1)
Radiated Emissions 30~1000MHz                                                             4.70 dB                                 (1)
Radiated Emissions 1~18GHz                                                                5.00 dB                                 (1)
Radiated Emissions 18~40GHz                                                               5.54 dB                                 (1)
Occupied Bandwidth                                                   ---------                   (1)
Note (1): This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence
level using a coverage factor of k=1.96.



  1.6. Environmental conditions
During the measurement the environmental conditions were within the listed ranges:
Temperature:                                                         15~35°C
Relative Humidity:                                                   30~60 %
Air Pressure:                                                        101kPa




                                                           CTC Laboratories, Inc
                     1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
                          Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                       For anti-fake verification, please visit the official website of Certification and
                                                       Accreditation Administration of the People’s Republic of China : yz.cnca.cn


                                                       Page 7 of 27                         Report No.: GTI20180934F-2



2. GENERAL INFORMATION
2.1. Client Information
Applicant:                                Wahoo Fitness LLC

Address:                                  90 W. Wieuca Road #110 Atlanta Georgia 30342 United States

Manufacturer:                             East West Industries Vietnam LLC

Address:                                  NO.27, Street No.2, VSIP 2, Hoa Phu Ward, Thu Dau Mot City, Binh
                                          Duong Province, Vietnam 84, Viet Nam

2.2. General Description of EUT
Product Name:                      SMART TRAINER
Model/Type reference:              WF120
Adding Model(s):                   /
Model difference:                  /
Power supply:                      Input: AC 100-240V 50-60Hz 2.5A Max
                                   Output: DC 48V 3A
Hardware version:                  V1.0
Software version:                  V1.0
ANT+:
Supported type:                    ANT+
Modulation:                        GFSK
Operation frequency:               2457MHz
Antenna type:                      Ceramic Antenna
Antenna gain:                      5.46dBi




                                                        CTC Laboratories, Inc
                  1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
                       Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                    For anti-fake verification, please visit the official website of Certification and
                                                    Accreditation Administration of the People’s Republic of China : yz.cnca.cn


                                                        Page 8 of 27                         Report No.: GTI20180934F-2




 3. Description of Test Modes
Peripherals Devices:
                                         OUTSIDE SUPPORT EQUIPMENT
   No.   Equipment          Model          Serial No. Manufacture Trade name                                        Remark
                                                                                                                     N.A
                                                                                                                     N.A
                                                                                                                     N.A

Note: All the above equipment /cable were placed in worse case position to maximize emission signals during
emission test.

Operation Frequency
The Applicant provides communication tools software to control the EUT for staying in continuous
transmitting (Duty Cycle more than 98%) mode for testing.

ANT+
                        Channel                                                          Frequency (MHz)
                          00                                                                  2457


TEST MODE:

  For RF test items
  The engineering test program was provided and enabled to make EUT continuous transmit.
  For AC power line conducted emissions:
  The EUT was set to connect with large package sizes transmission.




                                                         CTC Laboratories, Inc
                   1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
                        Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                     For anti-fake verification, please visit the official website of Certification and
                                                     Accreditation Administration of the People’s Republic of China : yz.cnca.cn


                                                        Page 9 of 27                         Report No.: GTI20180934F-2



 4. Measurement Instruments List
Tonscend JS0806-2 Test system
                                                                                                    Calibrated
Item   Test Equipment         Manufacturer            Model No.             Serial No.                                   Calibrated until
                                                                                                      Date
         Spectrum                Rohde &
 1                                                       FSU26                100105             Jan. 07, 2017            Dec. 28 2019
         Analyzer                Schwarz
         Spectrum                Rohde &
 2                                                     FUV40-N                101331             Jan. 07, 2017            Dec. 28 2019
         Analyzer                Schwarz
        MXG Vector
 3        Signal                   Agilent              N5182A            MY47420864             Jan. 07, 2017            Dec. 28 2019
         Generator
          Signal
 4                                 Agilent              E8257D            MY46521908             Jan. 07, 2017            Dec. 28 2019
         Generator
 5      Power Sensor               Agilent             U2021XA             MY5365004             Jan. 07, 2017            Dec. 28 2019
 6      Power Sensor               Agilent             U2021XA             MY5365006             Jan. 07, 2017            Dec. 28 2019
        Simultaneous
 7                                 Agilent              U2531A            TW54493510             Jan. 07, 2017            Dec. 28 2019
       Sampling DAQ
           Climate
 8                                 TABAI                 PR-4G              A8708055             Jan. 07, 2017            Dec. 28 2019
          Chamber
       Wideband Radio
                                 Rohde &
 9     Communication                                   CMW500                 116410             Jan. 06, 2018            Dec. 28 2019
                                 Schwarz
            Tester
           Climate
 10                               ESPEC                 MT3065                     /              Jan. 04,2018            Dec. 28 2019
          Chamber
        300328 v2.1.1
 11                            TONSCEND                    v2.6                    /                       /                       /
         test system

Item     Test Equipment                Manufacturer                 Model No.                 Serial No.                Calibrated until

  1     EMI Test Receiver          Rohde & Schwarz                     ESCI                     100658                   Dec. 28 2019

  2       High pass filter             micro-tranics               HPM50111                        142                   Dec. 28 2019

  3     Log-Bicon Antenna              Schwarzbeck                 CBL6141A                       4180                   Dec. 28 2019
          Ultra-Broadband
  4                                      ShwarzBeck                BBHA9170                       25841                  Dec. 28 2019
              Antenna
  5        Loop Antenna                    LAPLAC                     RF300                        9138                  Dec. 28 2019

  6     Spectrum Analyzer          Rohde & Schwarz                    FSU26                     100105                   Dec. 28 2019

  7       Horn Antenna                 Schwarzbeck                BBHA 9120D                       647                   Dec. 28 2019

  8        Pre-Amplifier                      HP                      8447D                 1937A03050                   Dec. 28 2019

  9        Pre-Amplifier                    EMCI                  EMC051835                     980075                   Dec. 28 2019

 10       Antenna Mast                       UC                      UC3000                       N/A                          N/A

 11         Turn Table                       UC                      UC3000                       N/A                          N/A

 12     Cable Below 1GHz               Schwarzbeck                  AK9515E                      33155                   Dec. 28 2019

 13     Cable Above 1GHz               Hubersuhner              SUCOFLEX102                     DA1580                   Dec. 28 2019

 14           Splitter                  Mini-Circuit                 ZAPD-4                     400059                   Dec. 28 2019
          RF Connection
 15                                HUBER+SUHNER                      RE-7-FL                      N/A                    Dec. 28 2019
              Cable
                                                         CTC Laboratories, Inc
                   1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
                        Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                     For anti-fake verification, please visit the official website of Certification and
                                                     Accreditation Administration of the People’s Republic of China : yz.cnca.cn


                                                         Page 10 of 27                          Report No.: GTI20180934F-2

           RF Connection                 Chengdu
 16                                                                       ---                        ---                  Dec. 28 2019
               Cable                   E-Microwave
                                        Compliance
 17        High pass filter                                            BSU-6                      34202                   Dec. 28 2019
                                     Direction systems
                                         Chengdu                  EMCAXX-10R
 18          Attenuator                                                                              ---                  Dec. 28 2019
                                       E-Microwave                   NZ-3
            High and low
 19                                  ESPEC                 MT3065           12114019           Dec. 28 2019
          temperature box
Note:1. The Cal. Interval was one year.
     2. The cable loss has calculated in test result which connection between each test instruments.




                                                          CTC Laboratories, Inc
                    1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
                         Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                      For anti-fake verification, please visit the official website of Certification and
                                                      Accreditation Administration of the People’s Republic of China : yz.cnca.cn


                                                           Page 11 of 27                          Report No.: GTI20180934F-2



 5. TEST ITEM AND RESULTS
 5.1. AC Power Line Conducted Emissions
Limit

                                                 Conducted Emission Test Limit

                                                                             Maximum RF Line Voltage (dBV)
                         Frequency
                                                                      Quasi-peak Level             Average Level
                      150kHz~500kHz                                      66 ~ 56 *                    56 ~ 46 *
                       500kHz~5MHz                                           56                          46
                       5MHz~30MHz                                            60                          50
        Notes:
        (1) *Decreasing linearly with logarithm of the frequency.
        (2) The lower limit shall apply at the transition frequencies.
        (3) The limit decrease in line with the logarithm of the frequency in the range of 0.15 to 0.50MHz.


Test Configuration




Test Procedure

1.      The EUT was setup according to ANSI C63.10:2013 requirements.
2.      The EUT was placed on a platform of nominal size, 1 m by 1.5 m, raised 80 cm above the conducting
        ground plane. The vertical conducting plane was located 40 cm to the rear of the EUT. All other surfaces of
        EUT were at least 80 cm from any other grounded conducting surface.
3.      The EUT and simulators are connected to the main power through a line impedances stabilization network
        (LISN). The LISN provides a 50ohm /50uH coupling impedance for the measuring equipment.
         The peripheral devices are also connected to the main power through a LISN. (Please refer to the block
         diagram of the test setup and photographs)
4.      Each current-carrying conductor of the EUT power cord, except the ground (safety) conductor, was
        individually connected through a LISN to the input power source.
5.      The excess length of the power cord between the EUT and the LISN receptacle were folded back and forth
        at the center of the lead to form a bundle not exceeding 40 cm in length.
6.      Conducted Emissions were investigated over the frequency range from 0.15MHz to 30MHz using a receiver
        bandwidth of 9 kHz.
7.      During the above scans, the emissions were maximized by cable manipulation.



                                                            CTC Laboratories, Inc
                      1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
                           Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                        For anti-fake verification, please visit the official website of Certification and
                                                        Accreditation Administration of the People’s Republic of China : yz.cnca.cn


                                                          Page 12 of 27                          Report No.: GTI20180934F-2



Test Mode:

Please refer to the clause 3

Test Results


         Test Voltage:          AC 120V/60 Hz
         Terminal:              Line




         Emission Level= Read Level+ Correct Factor




                                                           CTC Laboratories, Inc
                     1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
                          Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                       For anti-fake verification, please visit the official website of Certification and
                                                       Accreditation Administration of the People’s Republic of China : yz.cnca.cn


                                                 Page 13 of 27                          Report No.: GTI20180934F-2




Test Voltage:          AC 120V/60 Hz
Terminal:              Neutral




Emission Level= Read Level+ Correct Factor




                                                  CTC Laboratories, Inc
            1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
                 Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                              For anti-fake verification, please visit the official website of Certification and
                                              Accreditation Administration of the People’s Republic of China : yz.cnca.cn


                                                          Page 14 of 27                          Report No.: GTI20180934F-2




 5.2. 20 dB Occupied Bandwidth
Limit

Operation frequency range 2400MHz~2483.5MHz.

TEST CONFIGURATION




TEST PROCEDURE

1.   The transmitter output was connected to the spectrum analyzer through an attenuator, the path loss was
     compensated to the results for each measurement.

2.   Set to the maximum power setting and enable the EUT transmit continuously

3.   Use the following spectrum analyzer settings:

     Span = approximately 2 to 3 times the 20 dB bandwidth, centered on a hopping channel

     RBW ≥ 1% of the 20 dB bandwidth, VBW ≥ RBW

     Sweep = auto, Detector function = peak, Trace = max hold

4.   Measure and record the results in the test report.


TEST MODE:

Please refer to the clause 3

TEST RESULTS

                                                                                              99%
                                                         20dB Bandwidth
              Type                Channel                                                  Bandwidth                 Result
                                                             (MHz)
                                                                                             (MHz)
             GFSK                     00                          1.1114                      0.9768                  Pass




                                                           CTC Laboratories, Inc
                     1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
                          Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                       For anti-fake verification, please visit the official website of Certification and
                                                       Accreditation Administration of the People’s Republic of China : yz.cnca.cn


                                                  Page 15 of 27                         Report No.: GTI20180934F-2




  20dB
Bandwidth




                   Date: 17.OCT.2018   11:29:51




  99%
Bandwidth




                   Date: 17.OCT.2018   11:31:45




                                                  CTC Laboratories, Inc
            1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
                 Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                              For anti-fake verification, please visit the official website of Certification and
                                              Accreditation Administration of the People’s Republic of China : yz.cnca.cn


                                                         Page 16 of 27                          Report No.: GTI20180934F-2




 5.3. Radiated field strength of the fundamental signal
LIMIT

                                             Field strength of fundamental                       Field strength of harmonics
     Fundamental frequency
                                                    (millivolts/meter)                                (microvolts/meter)
          902-928 MHz                              50 (94dBuV/m @3m)                                 500 (54dBuV/m @3m)
        2400-2483.5 MHz                            50 (94dBuV/m @3m)                                 500 (54dBuV/m @3m)
         5725-5875 MHz                             50 (94dBuV/m @3m)                                 500 (54dBuV/m @3m)
         24.0-24.25 GHz                          250 (108dBuV/m @3m)                                2500 (68dBuV/m @3m)
Frequencies above 1000 MHz, the field strength limits are based on average limits


TEST CONFIGURATION




TEST PROCEDURE

1.   The EUT was setup and tested according to ANSI C63.10:2013 requirements.
2.   The EUT is placed on a turn table which is 1.5 meter above ground. The turn table is rotated 360 degrees to
     determine the position of the maximum emission level.
3.   The EUT waspositioned such that the distance from antenna to the EUT was 3 meters.
4.   The antenna is scanned from 1 meter to 4 meters to find out the maximum emission level. Thisis repeated
     for both horizontal and vertical polarization of the antenna. In order to find the maximum emission, all of the
     interface cables were manipulated according to ANSI C63.10:2013 on radiated measurement.
5.   The receiver set as follow:
     RBW=1MHz, VBW=3MHz Peak detector for Peak value.
     RBW=1MHz, VBW=3MHz RMS detector for Average value.
TEST MODE:

Please refer to the clause 3



                                                          CTC Laboratories, Inc
                    1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
                         Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                      For anti-fake verification, please visit the official website of Certification and
                                                      Accreditation Administration of the People’s Republic of China : yz.cnca.cn


                                                        Page 17 of 27                          Report No.: GTI20180934F-2



TEST RESULTS

                Read       Correction                                                Limit         Margin
Frequency                                                                                                                             Test
                Level         Factor               Level (dBuV/m)                    Line                       Polarization
 (MHz)                                                                                              (dB)                              value
               (dBuV)         (dB/m)                                             (dBuV/m)
  2457          64.21          -5.63                      58.58                      114           -55.42          Vertical           Peak
  2457          65.32          -5.63                      59.69                      114           -54.31        Horizontal           Peak

 Remark:
         1.   Emission level (dBuV/m) =Raw Value (dBuV)+Correction Factor (dB/m)
         2.   Correction Factor (dB/m) = Antenna Factor (dB/m)+Cable Factor (dB)-Pre-amplifier Factor
         3.   Margin value = Limit value- Emission level.
         4.   -- Mean the PK detector measured value is below average limit.
         5.   The other emission levels were very low against the limit.




                                                         CTC Laboratories, Inc
                   1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
                        Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                     For anti-fake verification, please visit the official website of Certification and
                                                     Accreditation Administration of the People’s Republic of China : yz.cnca.cn


                                                       Page 18 of 27                          Report No.: GTI20180934F-2




 5.4. Radiated Spurious Emissions and Bandedge Emission
LIMIT
FCC CFR Title 47 Part 15 Subpart C Section 15.209/ RSS-210 Annex B
            Frequency                                      Limit (dBuV/m @3m)                                       Value

          30MHz~88MHz                                                40.00                                      Quasi-peak

          88MHz~216MHz                                               43.50                                      Quasi-peak

         216MHz~960MHz                                               46.00                                      Quasi-peak

          960MHz~1GHz                                                54.00                                      Quasi-peak

                                                                     54.00                                        Average
           Above 1GHz
                                                                     74.00                                          Peak

TEST CONFIGURATION

   9 kHz ~ 30 MHz




   30 MHz ~ 1 GHz




   Above 1 GHz




                                                        CTC Laboratories, Inc
                  1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
                       Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                    For anti-fake verification, please visit the official website of Certification and
                                                    Accreditation Administration of the People’s Republic of China : yz.cnca.cn


                                                           Page 19 of 27                          Report No.: GTI20180934F-2




TEST PROCEDURE

1.   The EUT was setup and tested according to ANSI C63.10:2013 requirements.
2.   The EUT is placed on a turn table which is 0.8 meter above ground for below 1 GHz, and 1.5 m for above 1
     GHz. The turn table is rotated 360 degrees to determine the position of the maximum emission level.
3.   The EUT was set 3 meters from the receiving antenna, which was mounted on the top of a variable height
     antenna tower.
4.   For each suspected emission, the EUT was arranged to its worst case and then tune the Antenna tower
     (from 1 m to 4 m) and turntable (from 0 degree to 360 degrees) to find the maximum reading. A pre-amp and
     a high pass filter are used for the test in order to get better signal level to comply with the guidelines.
5.   Set to the maximum power setting and enable the EUT transmit continuously.
6.   Use the following spectrum analyzer settings
     (1) Span shall wide enough to fully capture the emission being measured;
     (2) Below 1 GHz:
         RBW=120 kHz, VBW=300 kHz, Sweep=auto, Detector function=peak, Trace=max hold;
         If the emission level of the EUT measured by the peak detector is 3 dB lower than the applicable limit,
         the peak emission level will be reported. Otherwise, the emission measurement will be repeated using
         the quasi-peak detector and reported.
     (3) From 1 GHz to 10th harmonic:
         RBW=1MHz, VBW=3MHz Peak detector for Peak value.
         RBW=1MHz, VBW=3MHz RMS detector for Average value.


TEST MODE:

Please refer to the clause 3

TEST RESULTS




                                                            CTC Laboratories, Inc
                      1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
                           Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                        For anti-fake verification, please visit the official website of Certification and
                                                        Accreditation Administration of the People’s Republic of China : yz.cnca.cn


                                                      Page 20 of 27                          Report No.: GTI20180934F-2



Radiated Spurious Emissions

   9 kHz ~ 30 MHz
    The EUT was pre-scanned the frequency band (9 kHz ~ 30 MHz), found the radiated level lower
    than the limit, so don’t show on the report.
   30 MHz ~ 1 GHz

Polarization:                                                    Vertical




                                                       CTC Laboratories, Inc
                 1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
                      Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                   For anti-fake verification, please visit the official website of Certification and
                                                   Accreditation Administration of the People’s Republic of China : yz.cnca.cn


                                                        Page 21 of 27                          Report No.: GTI20180934F-2



Polarization:                                                      Horizontal




 Remark:
         1.   Emission level (dBuV/m) =Raw Value (dBuV)+Correction Factor (dB/m)
         2.   Correction Factor (dB/m) = Antenna Factor (dB/m)+Cable Factor (dB)-Pre-amplifier Factor
         3.   Margin value = Limit value- Emission level.
         4.   -- Mean the PK detector measured value is below average limit.
         5.   The other emission levels were very low against the limit.




                                                         CTC Laboratories, Inc
                   1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
                        Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                     For anti-fake verification, please visit the official website of Certification and
                                                     Accreditation Administration of the People’s Republic of China : yz.cnca.cn


                                                           Page 22 of 27                          Report No.: GTI20180934F-2



    Above 1 GHz

                   Read       Correction                                                Limit         Margin
Frequency                                                                                                                                Test
                   Level         Factor               Level (dBuV/m)                    Line                       Polarization
    (MHz)                                                                                              (dB)                              value
                  (dBuV)         (dB/m)                                             (dBuV/m)
    4914           45.23          -4.29                      40.94                       74           -33.06          Vertical           Peak
    7371           44.78          1.05                       45.83                       74           -28.17         Vertical            Peak
    4914           43.26          -4.29                      38.97                       74           -35.03        Horizontal           Peak
    7371           40.39           1.05                      41.44                       74           -32.56        Horizontal           Peak

 Remark:
            1.   Emission level (dBuV/m) =Raw Value (dBuV)+Correction Factor (dB/m)
            2.   Correction Factor (dB/m) = Antenna Factor (dB/m)+Cable Factor (dB)-Pre-amplifier Factor
            3.   Margin value = Limit value- Emission level.
            4.   -- Mean the PK detector measured value is below average limit.
            5.   The other emission levels were very low against the limit.




                                                            CTC Laboratories, Inc
                      1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
                           Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                        For anti-fake verification, please visit the official website of Certification and
                                                        Accreditation Administration of the People’s Republic of China : yz.cnca.cn


                                                       Page 23 of 27                          Report No.: GTI20180934F-2



Bandedge Emission

      Ant. Pol.                Horizontal
      Test Mode:               2457MHz




                                                        CTC Laboratories, Inc
                  1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
                       Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                    For anti-fake verification, please visit the official website of Certification and
                                                    Accreditation Administration of the People’s Republic of China : yz.cnca.cn


                                                      Page 24 of 27                          Report No.: GTI20180934F-2




     Ant. Pol.                Vertical
     Test Mode:               2457MHz




Remark:
     1.   Emission level (dBuV/m) =Raw Value (dBuV)+Correction Factor (dB/m)
     2.   Correction Factor (dB/m) = Antenna Factor (dB/m)+Cable Factor (dB)-Pre-amplifier Factor
     3.   Margin value = Limit value- Emission level.
     4.   -- Mean the PK detector measured value is below average limit.
     5.   The other emission levels were very low against the limit.




                                                       CTC Laboratories, Inc
                 1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
                      Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                   For anti-fake verification, please visit the official website of Certification and
                                                   Accreditation Administration of the People’s Republic of China : yz.cnca.cn


                                                         Page 25 of 27                          Report No.: GTI20180934F-2




 5.5. Antenna requirement
Requirement

FCC CFR Title 47 Part 15 Subpart C Section 15.203:
 An intentional radiator shall be designed to ensure that no antenna other than that furnished by the responsible
 party shall be used with the device. The use of a permanently attached antenna or of anantenna that uses a
 unique coupling to the intentional radiator, the manufacturer may design the unit so that a broken antenna can
 be replaced by the user, but the use of a standard antenna jack or electrical connector is prohibited.
FCC CFR Title 47 Part 15 Subpart C Section 15.247(c) (1)(i):
 (i) Systems operating in the 2400~2483.5 MHz band that is used exclusively for fixed. Point-to-point operations
 may employ transmitting antennas with directional gain greater than 6dBi provided the maximum conducted
 output power of the intentional radiator is reduced by 1 dB for every 3 dB that the directional gain of the antenna
 exceeds 6dBi.

Test Result

The EUT's antenna is soldered to the PCB using a ceramic antenna. The gain of the antenna is 5.46 dBi.
                                                                    asdass ada




Please reference to the annex: Internal Photographs




                                                          CTC Laboratories, Inc
                    1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
                         Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                      For anti-fake verification, please visit the official website of Certification and
                                                      Accreditation Administration of the People’s Republic of China : yz.cnca.cn


                                                      Page 26 of 27                          Report No.: GTI20180934F-2



 6. EUT TEST PHOTOS
Please reference to the annex: Test Photo




                                                       CTC Laboratories, Inc
                 1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
                      Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                   For anti-fake verification, please visit the official website of Certification and
                                                   Accreditation Administration of the People’s Republic of China : yz.cnca.cn


                                                      Page 27 of 27                          Report No.: GTI20180934F-2




 7. PHOTOGRAPHS OF EUT CONSTRUCTIONAL
Please reference to the annex: Extra EUT Photo and Internal EUT Photo



                    **********************THE END**********************




                                                       CTC Laboratories, Inc
                 1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
                      Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                   For anti-fake verification, please visit the official website of Certification and
                                                   Accreditation Administration of the People’s Republic of China : yz.cnca.cn



Document Created: 2019-09-06 15:51:57
Document Modified: 2019-09-06 15:51:57

© 2025 FCC.report
This site is not affiliated with or endorsed by the FCC