MPE Report

FCC ID: P3TDH737

RF Exposure Info

Download: PDF
FCCID_4389632

849 NW STATE ROAD 45                                             PHONE: 888.472.2424 OR 352.472.5500
NEWBERRY, FL 32669 USA                                                     EMAIL: INFO@TIMCOENGR.COM
                                                                       WEB: HTTP://WWW.TIMCOENGR.COM




                                          An IIA Company




    RF Exposure Evaluation Report
                   APPLICANT                     FIPLEX COMMUNICATIONS INC.
                                                      2101 NW 79th Ave.
                         ADDRESS
                                                      MIAMI FL 33122 USA
                          FCC ID                            P3TDH737
             MODEL NUMBER                                      DH737
   PRODUCT DESCRIPTION                        700MHZ BAND INDUSTRIAL BOOSTER
   DATE SAMPLE RECEIVED                                    07/15/2019
            FINAL TEST DATE                                07/26/2019
                PREPARED BY                                Franklin Rose
                TEST RESULTS                               PASS            FAIL




   Report Number            Report Version            Description                  Issue Date
     1803AUT19
                                   Rev1                Initial Issue                08/02/2019
   MPE_TestReport_




 THE ATTACHED REPORT SHALL NOT BE REPRODUCED EXCEPT IN FULL WITHOUT THE
              WRITTEN APPROVAL OF TIMCO ENGINEERING, INC.


                                            TABLE OF CONTENTS

GENERAL REMARKS ........................................................................................................ 2



GENERAL INFORMATION ................................................................................................ 3



ANTENNA INFORMATION ............................................................................................... 3



MPE CALCULATION ......................................................................................................... 3



MPE TABLE ..................................................................................................................... 5



  GENERAL UNCONTROLLED EXPOSURE ......................................................................................... 5


  GENERAL CONTROLLED EXPOSURE ............................................................................................ 6


GENERAL REMARKS

Summary

The device under test does:

       Fulfill the general approval requirements as identified in this test report and was
       selected by the customer.

       Not fulfill the general approval requirements as identified in this test report

Attestations

This equipment has been tested in accordance with the standards identified in this test
report. To the best of my knowledge and belief, these tests were performed using the
measurement procedures described in this report.

All instrumentation and accessories used to test products for compliance to the indicated
standards are calibrated regularly in accordance with ISO 17025 requirements.

I attest that the necessary measurements were made at:

Timco Engineering Inc.
849 NW State Road 45
Newberry, FL 32669
Designation #: US1070

Prepared by:




       Name and Title       Franklin Rose, Project Manager / EMC Specialist
       Date                 08/02/2019




Applicant:   FIPLEX COMMUNICATIONS INC.
FCC ID:      P3TDH737
Report:      1803AUT19 MPE_TestReport_Rev1                                       Page 2 of 6


GENERAL INFORMATION

               EUT Description       700 BAND INDUSTRIAL BOOSTER
                 Model Number        DH737
                                     ☒110–120Vac, 50–
             EUT Power Source                                     ☐ DC Power         ☐ Battery Operated
                                     60Hz
                                     ☐ Engineering
                       Test Item                                  ☒ Pre-Production   ☐ Production
                                     Prototype
             Type of Equipment       ☒ Fixed                      ☐ Mobile           ☐ Portable
             Antenna Connector       external N Type
                                     The temperature was 26ºC
                Test Conditions
                                     Relative humidity of 50%.
      Modification to the EUT        No Modification to EUT.
        Applicable Standards         FCC CFR 47 Part 2.1091
                                     Timco Engineering Inc. at 849 NW State Road 45 Newberry, FL
                     Test Facility
                                     32669 USA. Designation #: US1070

ANTENNA INFORMATION

   Manufacturer Provides                                                                   Max Gain
                                                              Type
         Antenna                                                                            (dBi)
                No                                          Unspecified                      0 dBi

POWER OUTPUT OF EUT

                                               Maximum Output
                                Frequency         (+Tune-up          Output (W)
                                               Tolerance) (dBm)
                                 800.00             39.00              7.94


The output power levels of the Uplink and Downlink of this Distributed Antenna System Industrial
Signal Booster have been evaluated together for a worst-case MPE Safety Distance.




Applicant:     FIPLEX COMMUNICATIONS INC.
FCC ID:        P3TDH737
Report:        1803AUT19 MPE_TestReport_Rev1                                               Page 3 of 6


MPE CALCULATION

The minimum separation distance is calculated as follows:




MPE LIMITS




Applicant:   FIPLEX COMMUNICATIONS INC.
FCC ID:      P3TDH737
Report:      1803AUT19 MPE_TestReport_Rev1                  Page 4 of 6


MPE Table

General Uncontrolled Exposure

       The limit for General Uncontrolled Exposure Environment is calculated as shown in
       FCC Pt. 1.1310, Table B:

                 Variable                                      Value

                Max Power                                      7.94 W

             Frequency Range                               758 – 805 MHz

         Duty Cycle (at full power)                             100%
             Max Antenna Gain                                   0 dB

                 Coax Loss                                      0 dB
               Power Density                               0.505 mW/cm2

       Minimum Separation Distance                            35.36 cm

                                                                                          2
                                        35.36 cm                           0.505 mW/cm




                                                                                              2
                                          20 cm                              1.58 mW/cm
                                 (Standard MPE Distance)




                                          EUT




Applicant:   FIPLEX COMMUNICATIONS INC.
FCC ID:      P3TDH737
Report:      1803AUT19 MPE_TestReport_Rev1                                  Page 5 of 6


General Controlled Exposure

       The limit for General Controlled Exposure Environment is calculated as shown in
       FCC Pt. 1.1310, Table A:

                 Variable                                       Value

                Max Power                                      7.94 W

             Frequency Range                               758 – 805 MHz

         Duty Cycle (at full power)                             100%
             Max Antenna Gain                                   0 dBi

                 Coax Loss                                       0 dB
               Power Density                                1.58 mW/cm2

       Minimum Separation Distance                              20 cm

                                                                                       2
                                          20 cm                           1.58 mW/cm
                                 (Standard MPE Distance)




                                                                                           2
                                        15.81 cm                             2.53 mW/cm




                                          EUT




Applicant:   FIPLEX COMMUNICATIONS INC.
FCC ID:      P3TDH737
Report:      1803AUT19 MPE_TestReport_Rev1                                  Page 6 of 6



Document Created: 2019-08-05 17:06:38
Document Modified: 2019-08-05 17:06:38

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC