SZ-WTD01 FCC MPE Test Report

FCC ID: P27SZWTD01

RF Exposure Info

Download: PDF
FCCID_2095239

                Compliance Certification Services Inc.
                  Report No.: T130815D06                                              Date of Issue: October 01, 2013




APPENDIX I
RADIO FREQUENCY EXPOSURE
LIMIT
According to §15.247(i), systems operating under the provisions of this section shall be
operated in a manner that ensures that the public is not exposed to radio frequency energy
levels in excess of the Commission's guidelines. See § 1.1307(b)(1) of this chapter.
EUT Specification
EUT                              ZigBee Water Sensor

Trade Name                       SerComm / iControl / AT&T / Securifi
                                 SZ-WTD01xxxxxxxx(The “x” in model name can be 0 to 9, A
Model Number
                                 to Z, blank or “-“ for marking purpose)

Frequency band                        2405 ~ 2480MHz
(Operating)                           Others
                                     Portable (<20cm separation)
Device category                      Mobile (>20cm separation)
                                     Others
                                     Occupational/Controlled exposure (S = 5mW/cm2)
Exposure
                                     General Population/Uncontrolled exposure
classification
                                     (S=1mW/cm2)

Antenna
                                 PCB Antenna, Gain: 2.18 dBi, (Numeric gain: 1.65)
Specification

Average output
                                 17.92 dBm (61.944mW)
power

Modulation
                                 OPQSK (Offset Quadrature Phase Shift Keyed)
Technique

                                      MPE Evaluation*
Evaluation applied                    SAR Evaluation
                                      N/A
 Remark:
 The maximum output power is 17.92dBm (61.944mW) at 2445MHz (without 1.65 numeric
 antenna gain.)




                                                                Page 1                                                Rev.00
   This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                Compliance Certification Services Inc.
                  Report No.: T130815D06                                              Date of Issue: October 01, 2013


TEST RESULTS
No non-compliance noted.

Calculation
              30  P  G        E2
Given     E             & S
                  d             377
         Where E = Field strength in Volts / meter
                P = Power in Watts
                G = Numeric antenna gain
                d = Distance in meters
                S = Power density in milliwatts / square centimeter
Combining equations and re-arranging the terms to express the distance as a function of
the remaining variables yields:
               30  P  G
          S
                377d 2

Changing to units of mW and cm, using:
         P (mW) = P (W) / 1000 and
         d (cm) = d(m) / 100

Yields
               30  P / 1000  G                   PG
          S                            0.0796               Equation 1
                 377  d / 100
                                   2
                                                      d2
         Where d = Distance in cm
               P = Power in mW
               G = Numeric antenna gain
               S = Power density in mW / cm2




                                                                Page 2                                                Rev.00
   This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                Compliance Certification Services Inc.
                   Report No.: T130815D06                                             Date of Issue: October 01, 2013




Maximum Permissible Exposure

Substituting the MPE safe distance using d = 20 cm into Equation 1:
  S  0.000199  P  G
Where P = Power in mW
      G = Numeric antenna gain
      S = Power density in mW / cm2

IEEE 802.15.4 mode:
  Ch.    Frq.(MHz)     P (mW)      Gain (num.)     D (cm) Power density in mW / cm2               Limit (mW/cm2)
  2         2445        61.944         1.65          20             0.0203                                1




                                                                Page 3                                                Rev.00
   This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.



Document Created: 2013-10-01 17:33:32
Document Modified: 2013-10-01 17:33:32

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC