RF Exposure Info (MPE)

FCC ID: P27-TPM540

RF Exposure Info

Download: PDF
FCCID_4159738

                                                           RF Exposure Report

                       Report No.: SA181123D01

                            FCC ID: P27-TPM540

                       Test Model: TPM540; TPM540G

                 Received Date: Nov. 23, 2018

          Date of Evaluation: Jan. 09, 2019

                     Issued Date: Jan. 10, 2019


                         Applicant: Sercomm Corp.

                          Address: 8F, No. 3-1, YuanQu St., NanKang, Taipei 115, Taiwan, R.O.C. (NanKang
                                   Software Park)



                        Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch

                    Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan,
                                 R.O.C.
                  Test Location: No. 19, Hwa Ya 2nd Rd, Wen Hwa Vil, Kwei Shan Dist., Taoyuan City
                                 33383, Taiwan (R.O.C)
            FCC Registration /
                                            788550 / TW0003
       Designation Number:




This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted
only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this
report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product
unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you
provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided,
however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific
mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification. The report
must not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies.
Report No.: SA181123D01                                              Page No. 1 / 6                                             Report Format Version: 6.1.1


                                                                   Table of Contents
Release Control Record .................................................................................................................................. 3
1         Certificate of Conformity ...................................................................................................................... 4
2         RF Exposure .......................................................................................................................................... 5
    2.1      Limits for Maximum Permissible Exposure (MPE) .............................................................................. 5
    2.2      MPE Calculation Formula ................................................................................................................... 5
    2.3      Classification ....................................................................................................................................... 5
    2.4      Antenna Gain ...................................................................................................................................... 5
    2.5      Calculation Result of Maximum Conducted Power ............................................................................. 6




Report No.: SA181123D01                                              Page No. 2 / 6                                              Report Format Version: 6.1.1


                                         Release Control Record


Issue No.             Description                                        Date Issued
SA181123D01           Original Release                                   Jan. 10, 2019




Report No.: SA181123D01                     Page No. 3 / 6        Report Format Version: 6.1.1


1    Certificate of Conformity


            Product: Cat-M1 Module

              Brand: Sercomm

        Test Model: TPM540; TPM540G

    Sample Status: Engineering Sample

          Applicant: Sercomm Corp.

Date of Evaluation: Jan. 09, 2019

         Standards: FCC Part 2 (Section 2.1091)

                          KDB 447498 D01 General RF Exposure Guidance v06
                          IEEE C95.1-1992



The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd.,
Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data
evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts
of the measurements of the sample’s RF characteristics under the conditions specified in this report.




     Prepared by :                                               ,   Date:       Jan. 10, 2019
                                  Gina Liu / Specialist




     Approved by :                                               ,   Date:       Jan. 10, 2019
                             Dylan Chiou / Project Engineer




Report No.: SA181123D01                         Page No. 4 / 6                        Report Format Version: 6.1.1


2      RF Exposure

2.1      Limits for Maximum Permissible Exposure (MPE)

    Frequency Range          Electric Field     Magnetic Field         Power Density         Average Time
         (MHz)              Strength (V/m)      Strength (A/m)           (mW/cm2)              (minutes)
                             Limits For General Population / Uncontrolled Exposure
        0.3-1.34                 614                  1.63                 (100)*                   30
         1.34-30                824/f                2.19/f               (180/f2)*                 30
         30-300                  27.5                0.073                   0.2                    30
        300-1500                  …                    …                   f/1500                   30
      1500-100,000                …                    …                     1.0                    30

f = Frequency in MHz ; *Plane-wave equivalent power density



2.2      MPE Calculation Formula

Pd = (Pout*G) / (4*pi*r2)
where
Pd = power density in mW/cm 2
Pout = output power to antenna in mW
G = gain of antenna in linear scale
pi = 3.1416
r = distance between observation point and center of the radiator in cm



2.3      Classification

      The antenna of this product, under normal use condition, is at least 20cm away from the body of the user.
         So, this device is classified as Mobile Device.




2.4      Antenna Gain

The antennas information is listed as below.
                                                            Antenna Gain (dBi)
       Antenna Type            LTE Band 2            LTE Band 4              LTE Band 12           LTE Band 13
    Monopole (PCB)               4.18                   4.68                    2.04                   2.22




Report No.: SA181123D01                          Page No. 5 / 6                            Report Format Version: 6.1.1


2.5     Calculation Result of Maximum Conducted Power

                Frequency Band    Max Power     Antenna Gain   Distance   Power Density       Limit
      Band
                    (MHz)           (dBm)           (dBi)        (cm)       (mW/cm2)        (mW/cm2)
      LTE 2        1850-1910        23.71             4.18       20          0.122              1.00

      LTE 4        1710-1755        23.92             4.68       20          0.144              1.00

      LTE 12        699-716         23.14             2.04       20          0.066              0.47

      LTE 13        777-787         21.49             2.22       20          0.047              0.52



Conclusion:
The formula of calculated the MPE is:
CPD1 / LPD1 + CPD2 / LPD2 + ……etc. < 1
CPD = Calculation power density
LPD = Limit of power density


LTE Band 2= 0.122 / 1= 0.122
LTE Band 4= 0.144 / 1= 0.144
LTE Band 12= 0.066 / 0.47= 0.140
LTE Band 13= 0.047 / 0.52= 0.090

Therefore the maximum calculations of above situations are less than the “1” limit.



--- END ---




Report No.: SA181123D01                       Page No. 6 / 6                    Report Format Version: 6.1.1



Document Created: 2019-01-25 18:27:21
Document Modified: 2019-01-25 18:27:21

© 2024 FCC.report