Test Report - 3 of 3

FCC ID: P25R232267A

Test Report

Download: PDF
FCCID_2543691

              R


                      AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:P25R232267A                                               page          5-13


             8-DPSK




                         Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F15024


              R


                                                       AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:P25R232267A                                                                                  page           6-1



        6. CARRIER FREQUENCY SEPARATION TEST
            6.1.Test Equipment
        Item   Equipment      Manufacturer Model No. Serial No. Last Cal. Cal. Interval
          1 Spectrum Analyzer   Agilent    N9030A MY51380221 Oct.29, 14      1Year


            6.2.Limit
                  Frequency hopping systems shall have hopping channel carrier frequency separated by
                  a minimum of 25kHz or the 20dB bandwidth of the hopping channel, whichever is greater.
                  Alternatively, frequency hopping systems operating in the 2400-2483.5 MHz band may
                  have hopping channel carrier frequencies that are separated by 25 kHz or two-thirds of the
                  20 dB bandwidth of the hopping channel, whichever is greater, provided the systems
                  operate with an output power no greater than 125 mW.
            6.3.Test Results.
     EUT: L.Y.N.X.9 Mobile Hybrid Controller
     M/N: 32267
     Test date: 2014-10-29         Pressure: 101.2±1.0 kpa                     Humidity: 50.8±3.0%
     Tested by: Kobe_Huang         Test site: RF Site                          Temperature:21 .4±0.6℃

          Test Mode                    Channel separation                             Conclusion
           8-DPSK                            1.0MHz                                      PASS
           GFSK                              1.0MHz                                      PASS




                                                            Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F15024


              R


                     AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:P25R232267A                                              page           6-2




                        Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F15024


                R


                                                        AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:P25R232267A                                                                                     page           7-1



         7. 20 DB BANDWIDTH TEST
               7.1.Test Equipment
                                                                                                                Cal.
        Item        Equipment     Manufacturer       Model No.            Serial No.          Last Cal.
                                                                                                              Interval
        1.          Spectrum          Agilent         N9030A            MY51380221           Oct.29, 14        1Year
                    Attenuator
        2.                            Agilent          8491B            MY39262165           Apr. 28,14        1 Year
                     (20dB)
        3.          RF Cable        Hubersuhner   SUCOFLEX102               28620/2          Apr. 28,14        1 Year


               7.2.Limit
                     Intentional radiators operating under the alternative provisions to the general emission
                     limits, as contained in §§ 15.217 through 15.257 and in Subpart E of this part, must be
                     designed to ensure that the 20 dB bandwidth of the emission, or whatever bandwidth
                     may otherwise be specified in the specific rule section under which the equipment
                     operates, is contained within the frequency band designated in the rule section under
                     which the equipment is operated.

               7.3.Test Results
     EUT: L.Y.N.X.9 Mobile Hybrid Controller
     M/N: 32267
     Test date: 2014-10-09         Pressure: 101.2±1.0 kpa                        Humidity: 53.3±3.0%
     Tested by: Kobe_Huang         Test site: RF Site                             Temperature:22.5±0.6℃

                           Frequency              20dB bandwidth                                Limit
       Test Mode
                           (MHz)                     (KHz)                                      (KHz)
                             2402                      869.6                                     N/A
         GFSK                2441                      865.8                                     N/A
                             2480                      859.6                                     N/A
                             2402                      1210                                      N/A
        8-DPSK               2441                      1210                                      N/A
                             2480                      1211                                      N/A
     Conclusion:PASS




                                                               Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F15024


              R


                                  AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:P25R232267A                                                           page           7-2


        GFSK
        Test Frequency: 2402MHz




        Test Frequency: 2441MHz




                                     Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F15024


              R


                                  AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:P25R232267A                                                           page           7-3


        Test Frequency: 2480MHz




        8-DPSK
        Test Frequency: 2402MHz




                                     Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F15024


              R


                                  AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:P25R232267A                                                           page           7-4


        Test Frequency: 2441MHz




        Test Frequency: 2480MHz




                                     Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F15024


              R


                                                     AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:P25R232267A                                                                                 page           8-1



         8. NUMBER OF HOPPING FREQUENCY TEST
             8.1.Test Equipment
        Item   Equipment      Manufacturer        Model No.        Serial No. Last Cal. Cal. Interval
          1 Spectrum Analyzer   Agilent           N9030A          MY51380221 Oct.29, 14    1Year


             8.2.Limit
                  Frequency hopping systems in the 2400-2483.5 MHz band shall use at least 15 channels

             8.3.Test Results
     EUT: L.Y.N.X.9 Mobile Hybrid Controller
     M/N: 32267
     Test date: 2014-10-09         Pressure: 101.2±1.0 kpa                    Humidity: 50.8±3.0%
     Tested by: Kobe_Huang            Test site: RF Site                      Temperature:21 .4±0.6℃

           Test Mode         Number of channel              Limit                         Conclusion
           8-DPSK                   79                      >=15                              PASS
            GFSK                    79                      >=15                              PASS




                                                           Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F15024


              R


                     AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:P25R232267A                                              page           8-2




                        Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F15024


                  R


                                                            AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:P25R232267A                                                                                      page           9-1



            9. DWELL TIME
               9.1.Test Equipment
                                                                                                                 Cal.
 Item           Equipment             Manufacturer     Model No.           Serial No.          Last Cal.
                                                                                                               Interval
   1        Spectrum Analyzer            Agilent        N9030A           MY51380221 Oct.29, 14                  1Year


               9.2.Limit
                      The average time of occupancy on any channel shall not be greater than 0.4 seconds
                      within a period of 0.4 seconds multiplied by the number of hopping channels employed.

               9.3.Test Results
       EUT: L.Y.N.X.9 Mobile Hybrid Controller
       M/N: 32267
       Test date: 2014-10-09         Pressure: 101.2±1.0 kpa                       Humidity: 50.8±3.0%
       Tested by: Kobe_Huang               Test site: RF Site                      Temperature:21 .4±0.6℃

            Mode                               dwell time                                Limit          Conclusion
                   DH1 50hops/5s*0.4*79chanels*0.449ms =141.884ms                      <400ms              PASS
        GFSK       DH3 26hops/5s*0.4*79chanels*1.698ms =279.02ms                       <400ms              PASS
                   DH5 17hops/5s*0.4*79chanels*2.955ms=317.485ms                       <400ms              PASS
                   DH1 53hops/5s*0.4*79chanels*0.454ms=152.072ms                       <400ms              PASS
       8-DPSK      DH3 25hops/5s*0.4*79chanels*1.710ms =270.18ms                       <400ms              PASS
                   DH5 17hops/5s*0.4*79chanels*2.970ms =319.10ms                 <400ms                    PASS
       Note: All the lower levels were signal from receiver’s, and should not considered
             in here.




                                                                Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F15024


              R


                          AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:P25R232267A                                                   page           9-2

        Test Mode: GFSK
        DH1




                             Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F15024


              R


                     AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:P25R232267A                                              page           9-3


        DH3




                        Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F15024


               R


                     AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:P25R232267A                                              page           9-4


         DH5




                        Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F15024


              R


                            AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:P25R232267A                                                     page           9-5


         Test Mode: 8DPSK
         DH1




                               Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F15024


               R


                     AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:P25R232267A                                              page           9-6


         DH3




                        Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F15024


               R


                     AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:P25R232267A                                              page           9-7


         DH5




                        Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F15024


                 R


                                                           AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:P25R232267A                                                                                       page          10-1



          10. MAXIMUM PEAK OUTPUT POWER TEST
            10.1.Test Equipment
  Item     Equipment         Manufacturer         Model No.             Serial No.          Last Cal.        Cal. Interval
    1.     Spectrum            Agilent            N9030A               MY51380221           Oct.29, 14          1Year
   2.     Power meter           Anritsu           ML2487A              6K00002472          Apr. 28,14            1Year
   3.     Power sensor          Anritsu           MA2491A                0033005           Apr. 28,14            1Year
           Attenuator
   4.                           Agilent             8491B              MY39262165          Apr. 28,14            1Year
            (20dB)
   5.      RF Cable           Hubersuhner      SUCOFLEX102               28610/2           Apr. 28,14            1Year


            10.2.Limit
                     For frequency hopping systems operating in the 2400-2483.5 MHz band employing at
                     least 75 non-overlapping hopping channels, and all frequency hopping systems in the
                     5725-5850 MHz band: 1 watt. For all other frequency hopping systems in the
                     2400-2483.5 MHz band: 0.125 watts.
            10.3.Test Procedure
                     Use a power meter test the output power directly.
            10.4.Test Results
     EUT: L.Y.N.X.9 Mobile Hybrid Controller
     M/N: 32267
     Test date: 2014-10-09        Pressure: 101.2±1.0             kpa              Humidity: 53.1±1.0%
     Tested by: Kobe_Huang                Test site: RF site                       Temperature:22.5±1.0 ℃



         Test               Frequency                 Peak output Power                           Limit
         Mode                 (MHz)                       (dBm)                                  (dBm)
                               2402                            5.827                               30
         GFSK                  2441                            6.693                               30
                               2480                            7.397                               30
                               2402                            4.216                               30
        8-DPSK                 2441                            5.616                               30
                               2480                            6.600                               30
     Conclusion: PASS




                                                                 Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F15024


              R


                                                      AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:P25R232267A                                                                                page          11-1



           11. BAND EDGE COMPLIANCE TEST
            11.1.Test Equipment
     Item   Equipment     Manufacturer      Model No.      Serial No.         Last Cal.           Cal. Interval
       1.     Amp             HP             8449B        3008A02495          Apr. 28,14            1 Year
              Horn
      2.                       ETS             3115        9510-4580          Jun. 06, 14            1 Year
             Antenna
      3.    HF Cable       Hubersuhner     Sucoflex104      274094/4          Apr. 28,14             1 Year
      4.    RF Cable       Hubersuhner     Sucoflex102      28610/2           Apr. 28,14             1 Year
            11.2.Limit
                  All the lower and upper band-edges emissions appearing within 2310MHz to 2390MHz
                  and 2483.5MHz to 2500MHz restricted frequency bands shall not exceed the limits
                  shown in 15.209, all the other emissions outside operation frequency band 2400MHz to
                  2483.5MHz shall be at least 20dB below the fundamental emissions, or comply with
                  15.209 limits.
            11.3.Test Produce
                  For upper band emissions that are up to two bandwidths(2MHz) away (2483.5MHz to
                  2485.5MHz)from the band-edge use below produce:
                  1. Choose a spectrum analyzer span that encompasses both the peak of the fundamental
                      emission and the band-edge emission under investigation. Set the analyzer RBW
                      to 100KHz and with a video bandwidth 300KHz. Record the peak levels of the
                      fundamental emission and the relevant band-edge emission, Observe the stored trace
                      and measure the amplitude delta between the peak of the fundamental and the peak
                      of the band-edge emission. This is not a field strength measurement, it is only a
                      relative measurement to determine the amount by which the emission drops at the
                      band edge relative to the highest fundamental emission level.
                  2. Subtract the delta measured in step (1) from the maximum field strengths measured
                      in clause 4 .The resultant field strengths are then used to determine band-edge
                      compliance as required by Section 15.205
                  For emissions above two bandwidths away from the band-edge use below produce:
                  1. The EUT is placed on a turntable, which is 0.8m above the ground plane and
                      worked at highest radiated power.
                  2. The turntable was rotated for 360 degrees to determine the position of maximum
                      emission level.
                  3. EUT is set 3m away from the receiving antenna, which is varied from 1m to 4m to
                      find out the highest emission.
                  4. Set the spectrum analyzer in the following setting in order to capture the lower and
                      upperband-edges of the emission:
                     (a) PEAK: RBW=1MHz ;VBW=3MHz, PK detector, Sweep=AUTO
                     (b) This is pulse Modulation device a duty cycle factor was used to calculate average
                          level based measured peak level.
            11.4.Test Results
                  Pass (The testing data was attached in the next pages.)
                  Note: If the PK measured levels comply with average limit, then the average level were
                  deemed to comply with average limit.
                                                          Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F15024


AUDIX
   baes               Hestszots Reportittod corsncstsonoot rccmeme o2)
    120 Level @aBuntm                                                             bare:2014—12.00



                                                                                                 a

                                                                               FCCPART15CP£

     so                                                                          rccPARnJc
          erurncninntmentpromnen ceileirofiarecmntonctonenireccnnctiionmenis              s




      0                 zi.             i.                   Bua            z.                   Zi0s
                                             Frequency (te
          site no.       3m Chanber                    bata no.  s
          bis. / Ane.    m cord su15. (ase0)      Ane. o. : vermicat
          bimie          ree vart is peax
          Eav. / o.      2ono/ s
          Enainees       ove
          zur            L¥A 29 Mobile fybrdd Controlier
          Pover rating : o 5.77
          Test toge      orse seomme t noce
          w              serer

                        Ane.     cante an®                   Imission
    wo.      Freq.     Factor:   Loss factor    Reading       Level Limits: axgin       Remark
             gte)      (aB/m.    (aB) (am)       (douw)      (dbut/m) (cow/.     (a9)
     1    esemaas      se.os      sure ssuto    mausn        eaues    24.00 20.95.      Peak
     2.   2300.000     re.se     S.7e a5.20     asuzs        4399     74.00..30.01.     Peak
     3.   2a00.000     2e.r8     S.so a5.70     52.00..—     5o.28    74.00.. 23072     Peak
     a.   raoe.aso     me.re     S.eo a5.20     90.30.       68.58    74.00. ~14.59.    reak
          Revarks: 1. Eniasion Level= Antenta Factor + Cable Loss + Reading
                      ~Amp Factor
                      The emission levels ttat are 2040 below the official
                      Aimit are not reportec.


AUDIX
   batsco             iesF:2014 ReporttitadCarencstsononree meme (an)
    120 Level @aBuntm                                                             bare:2014—12.00




                                                                              recpant se de

     so                                                                          recpmr1
          armnudinmcngertionnreenanctdsnnnsneticton




          0           zi.              m                   z.              zi.                  2005
                                            Frequency ts
          site no.       In Chanber                     Data no.  6
          Dis. / Ane.    Jm com ouis (aseo)        Ane. por. norrzouman
          bimie          ree rart isc. prax
          Emv. / ms.     rare/ses
          Enainees       rove
          zur            b¥.l®.9 tobile fybesd Controller
          Pover rasing : ne sw
          Test toge      orse seormis tx noce
          w              sezer


                      Anc. canie arp                       Imission
    wo.    rrea.     ractor Loss dastor        Reading      Level Limits: Maxgin       Resark
           oste)     (anm (am)    (an)          (dbun)     (abut/ie(abwt/a)     (ab)
     1. 2sso.70s     ascas   sure sn to        aniks       asuer     24.00 20.93.      Peak
     2. 2200.000     as.as   s.eo asuto         Ssues      S9.90     74.00— 20.07°     Peak
     3. 2aoz.z4s     as.as   s.eo ssuto        Sause       Seuer     74.00. ~18.67.    Peak
          Revarks    Eniasion Level Antenta Factor + Cable Loss + Reading
                     ~Amp Factor
                     The emission levels ttat are 2040 below the official
                     Aimit are not reportec.


AUDIX
   bate: 15           iesF:2014 ReporttitadCarencstsononree meme (an)
    t20 Level(atuntm)                                                                bare:2014—12.00




                                                                               recpmt is peaw
                 7    T                                                                        —san
     &      /         \                                                             reepntmise av
                                                                                               un
                                 npnncmmnmnnrmmenforareicnnene                          slzmcacd




          2arr            zuse            202            2men               2oosa                25i0
                                             Frequency ts
           site no.       In Chanber                     bata no.    15
           pis. / an c.   Jm com ouis (aseo)        Ane. por. : norrzouman
           eo             ree rart isc. prax
           Bav. / mm      rare/ses
           Enatnees       rove
           sor            b¥.l®.9 tobile fybesd Controller
           Pover rating : ne sw
           Test tote      orse eesomts tx noce
           w              sezer


                           Anc.    canie arp                Imission
    wo.       rrea.       ractor   Loss dastor    Reading     Level Limits: Maxgin      Resark
              unte)       (anm     (am)  (an)      (dbun)    (abut/ie(abwt/a)    (ab)
     1     2400.00        as.ss     suer  ssuto   enae      eouee      24.00 ~15.990    Peak
     :     2103.500       as.ss     s.se  asuto    anirs     ws.94..   74.00 27.55.     Peak
     s     2500.000       es.ao    suee   ssuto    aou9r    wel55      74.00 31245      Peak
     a     2s00.z07       es.wo    suse   ssuto   mauso     49.24.—    74.00 30.76.     Peak
           Revarks: 1. Eniasion Level= Antenta Factor + Cable Loss + Reading
                       ~Amp Factor
                       The emission levels ttat are 2040 below the official
                       Aimit are not reportec.


AUDIX
   bate: 10           iesF:2014 ReporttitadCarencstsononree meme (an)
    t20 Level(atuntm)                                                            bare:2014—12.00




                                                                            recpmt is peaw
                                                                                       sn
     so
                                                                                            E3
                          Witmoninemmatmomnecancnte im d hnntnineceanmn




          2arr         zuse            202            2men               2oosa                25i0
                                          Frequency ts
           site no.       In Chanber                     bata no.   15
           pis. / ine.    Jm com ouis (aseo)        Ane. ons : vermicat
           eo             ree rart isc. prax
           Eav. / m.      rare/ses
           Enatnees       rove
           sor            b¥.l®.9 tobile fybesd Controller
           Pover rating : ne sw
           Test tote      orse eesomts tx noce
           w              sezer


                        Anc.    canie arp                Imission
    wo.       rrea.    ractor   Loss dastor    Reading    Level Limits: Maxgin       Resark
              unte)    (anm     (am)  (an)      (dbun)   (abut/ie(abwt/a)     (ab)
     1     2400.00     as.ss     s.er  ssuto   meuas     es.0s     74.00 —21.086.    Peak
     :     2103.500    as.ss     s.se  asuto   Seuto     Siuee     24.00. 2272       Peak
     s     e400.407    es.ao    s.se   ssuto    asuer    a9.85     74.00 30.45.      Peak
     a     2500.000    es.wo    suse   ssuto   aou80     wuea      74.00 31.56.      Peak
           Revarks: 1. Eniasion Level= Antenta Factor + Cable Loss + Reading
                       ~Amp Factor
                       The emission levels ttat are 2040 below the official
                       Aimit are not reportec.


AUDIX
   Dotec21              He:F—2014 ReportiBtedCatenCs ons rcc eme z)

    120 Level (Buntm)                                                                         Date:2014—12.08




                                                                                                            :
                                                                                       recomaise of
                                                                                                   Idhl
     so                                                                                          J
                                                                                         reopmerric
                                                                                          T             —




      i0                zim                zi.                     z0.             230.                     2105
                                                  Frequency (lte


          size no.       3m Chanber                   bata no. e
          bis. / Mne. on cors ouis (aseo)        Ant. por. : rontzorm
          hamic          ree sart is peax
          Eav. / mo. roro/ses
          Enainees       Hope
          zor            LVA .9 Moble fybesd Concroiier
          Pover eating : 10 5.m
          Test mode      o—oren eavzimie e roas
          w              seeer

                         Ane. cante amp                            Emission
    wo.      Freq.      Fastor Loss factor           Reading        Level Limits Haxgin Remark
             uite)      (db/m)   (aB)    (ab)         (dbuy)       (dbut/m) (dBut/n)      (ab)

     1    essslass      ceaas    sure    ssuto       mslss         eauzo    24.00 20.00.         Peak
     2    Bssolono      meise     site   sslro       akiri         azlos    24200 91105          reak
     5    eepolo00      meise     sleo    ssiro      silst         soles    24200 23075          reak
     a    Beorlsso      meise     sleo    ssiro      Se.00.        65.08    74.00. —11.05.       reak
          Revarks: 1. Eniasion Level= Antenta Factor + Cable Loss + Reading
                      ~Amp Factor
                      The emission levels ttat are 2040 below the official
                      Aimit are not reportec.


               R


                                                     AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:P25R232267A                                                                               page          11-7




     Frequency        Peak level Duty cycle factor      AV level
                                                                        Limit(dBuv/m)            Conclusion
     (MHz)           (dBuv/m)          (dB)            (dBuv/m)

        2400            56.41          -30.545          25.865                   54                 Pass




                                                         Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F15024


AUDIX
   bote:at            iesF:2014 ReporttitadCarencstsononree meme (an)
    t20 Level(atuntm)                                                            bare:2014—12.00




                                                                           recpmt is peaw


     «/
                                                                                      sn

                                                                                ree prise av




          2arr         zuse            202            2men              2oosa                25i0
                                          Frequency ts
           site no.       In Chanber                     bata no.    91
           pis. / ame.    on 2ord ains (ase0)       Ane. por. : norrzouman
           eo             ree rart isc. prax
           Eav. / mo.     2aro/sas
           Enatnees       rove
           sor            b¥.l®.9 tobile fybesd Controller
           Pover rasing : bo 5.77
           Test tote      s—prs¢ eacontie Tx tose
           w              seee


                        Anc.    canie arp                Imission
    Mo.       Freq.    Factor   Loss factor    Reading    Level Linits azgin        Remark
               unte)   (anm     (am)  (an)      (dbun)   (abut/ie(abwt/a)    (ab)
     1     esso.oos    ee.ss     suor  ssuto   eoute      eouee    74.00 ~14.20.    Peak
     2     asss.s00    me.se     s.ee  asuzo   qe.07     4265      74.00. 91.35     Peak
     3.    2so0.000    re.so    s.ee   as.zo   43.00     az.44     74.00. 91.56.    Peak
     a.    asoo.sas    re.so    S.oe aslo      anl94     4298      74.00 91.02.     Peak
           Revarks: 1. Eniasion Level= Antenta Factor + Cable Loss + Reading
                       ~Amp Factor
                       The emission levels ttat are 2040 below the official
                       Aimit are not reportec.


AUDIX
   bote: sz           iesF:2014 ReporttitadCarencstsononree meme (an)
    t20 Level(atuntm)                                                           pateczors—t208




                                                                            recpmt is peaw
           /        \                                                                       —oan
     ®              \                                             ree prise av
                        e                                                 E3
                                   enonreitbreicecresdem enon onnrmnieen




      Cmy                zuse             zo2             zmen           zuse                 Zio
                                             Frequency (te
          site no.        : 31 Chanber                    bata no.  52
          bis. / Ane.     : m cord su15. (ase0)      Ane. o. : vermicat
          bimie             ree vart is peax
          Eav. / o.         2ono/ s
          Enainees          ove
          zur               L¥A 29 Mobile fybrdd Controlier
          Pover rating    : Do 5.77
          Test toge         s—prs¢ easomtx roae
          w               : szeer

                          Ane.     cante an®               Imission
    wo.    Freq.         Factor:   Loss factor   Reading     Level Limits: axgin     Remark
           gte)          (aB/m.    (aB) (am)      (abuw)    (abut/i(amat/)    (an)
     1. 2aso.os.         reuse      suon ssuto   Bauts     souse     24.00 19232     Peak
     2. eaes.s0o         2e.se     Suee  a5.20   mslss     46.91..   7400 27.00      Peak
     3. 2s00.000         2880      S.ee as.20    asre      ancaz     74.00 20.59.    Peak
          Revarks        Eniasion Level Antenta Factor + Cable Loss + Reading
                         ~Amp Factor
                         The emission levels ttat are 2040 below the official
                         Aimit are not reportec.


               R


                             AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:P25R232267A                                                      page          12-1



  12. DEVIATION TO TEST SPECIFICATIONS
      [NONE]




                                Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F15024



Document Created: 2015-01-26 16:41:06
Document Modified: 2015-01-26 16:41:06

© 2024 FCC.report