Test Report

FCC ID: OYK-TX027145-0407

Test Report

Download: PDF
FCCID_547595

                                             Silverlit Toys Manufactory Ltd.


                                                        Application
                                                           For
                                                       Certification
                                              (FCC ID: OYK-TX027145-0407)

                                                                      Transmitter

                                           Sample Description : XP Controller
                                                Model : Not Applicable



      We hereby certify that the sample of the above item is considered to comply with the
           requirements of FCC Part 15, Subpart C for Intentional Radiator,
                               mention 47 CFR [12-8-2003]




0509473
BC/at
May 25, 2005
•   The test results reported in this report shall refer only to the sample actually tested and shall not refer or be deemed to refer to bulk from which such a sample may be
    said to have been obtained.

•   This report shall not be reproduced except in full without prior authorization from Intertek Testing Services Hong Kong Limited.

•   The evaluation data of the report will be kept for 3 years from the date of issuance.




FCC ID : OYK-TX027145-0407


                    INTERTEK TESTING SERVICES



                              LIST OF EXHIBITS

                 INTRODUCTION

                 EXHIBIT 1:             General Description

                 EXHIBIT 2:             System Test Configuration

                 EXHIBIT 3:             Emission Results

                 EXHIBIT 4:             Equipment Photographs

                 EXHIBIT 5:             Product Labelling

                 EXHIBIT 6:             Technical Specifications

                 EXHIBIT 7:             Instruction Manual

                 EXHIBIT 8:             Miscellaneous Information




FCC ID: OYK-TX027145-0407
                                                                    i


                        INTERTEK TESTING SERVICES


                     MEASUREMENT/TECHNICAL REPORT

          Silverlit Toys Manufactory Ltd. - MODEL: Not Applicable
                         FCC ID: OYK-TX027145-0407

                                     May 25, 2005




     This report concerns (check one:)     Original Grant X       Class II Change

     Equipment Type: Low Power Transmitter (example: computer, printer, modem, etc.)


     Deferred grant requested per 47 CFR 0.457(d)(1)(ii)?         Yes            No X

                                                 If yes, defer until:
                                                                              date
     Company Name agrees to notify the Commission by:
                                                                   date

     of the intended date of announcement of the product so that the grant can be
     issued on that date.

     Transition Rules Request per 15.37?                 Yes              No X

     If no, assumed Part 15, Subpart C for intentional radiator - the new 47 CFR [12-8-
     2003 Edition] provision.

     Report prepared by:                                 Billy Chow
                                                         Intertek Testing Services
                                                         2/F., Garment Center,
                                                         576, Castle Peak Road,
                                                         HONG KONG
                                                         Phone: 852-2173-8502
                                                         Fax: 852-2742-9149




FCC ID: OYK-TX027145-0407
                                                                                          ii


                                    INTERTEK TESTING SERVICES


                                                 Table of Contents

1.0 General Description ................................................................................................ 2
    1.1 Product Description ............................................................................................. 2
    1.2 Related Submittal(s) Grants................................................................................. 2
    1.3 Test Methodology ................................................................................................ 3
    1.4 Test Facility ......................................................................................................... 3

2.0 System Test Configuration ..................................................................................... 5
    2.1 Justification.......................................................................................................... 5
    2.2 EUT Exercising Software ..................................................................................... 5
    2.3 Special Accessories ............................................................................................ 5
    2.4 Equipment Modification ....................................................................................... 6
    2.5 Support Equipment List and Description .............................................................. 6

3.0 Emission Results .................................................................................................... 8
    3.1 Field Strength Calculation.................................................................................... 9
    3.1 Field Strength Calculation (cont’d) ..................................................................... 10
    3.2 Radiated Emission Configuration Photograph .................................................... 11
    3.3 Radiated Emission Data .................................................................................... 12

4.0 Equipment Photographs....................................................................................... 15

5.0 Product Labelling .................................................................................................. 17

6.0 Technical Specifications....................................................................................... 19

7.0 Instruction Manual ................................................................................................ 21

8.0 Miscellaneous Information ................................................................................... 23
    8.1 Measured Bandwidth......................................................................................... 24
    8.2 Discussion of Pulse Desensitization................................................................... 25
    8.3 Calculation of Average Factor............................................................................ 26
    8.4 Emission Test Procedures ................................................................................ 27
    8.4 Emission Test Procedures (Cont’d).................................................................... 28




FCC ID: OYK-TX027145-0407
                                                                                                                             iii


                        INTERTEK TESTING SERVICES




                                List of attached file

       Exhibit type              File Description                  filename
Test Report              Test Report                    report.pdf
Operation Description    Technical Description          descri.pdf
Test Setup Photo         Radiated Emission              radiated photos.doc
Test Report              Bandwidth Plot                 bw.pdf
External Photo           External Photo                 external photos.doc
Internal Photo           Internal Photo                 internal photos.doc
Block Diagram            Block Diagram                  block.pdf
Schematics               Circuit Diagram                circuit.pdf
ID Label/Location        Label Artwork and Location     label.pdf
User Manual              User Manual                    manual.pdf
Test Report              Average Factor                 af.pdf




FCC ID: OYK-TX027145-0407
                                                                              iv


                    INTERTEK TESTING SERVICES


                            EXHIBIT 1

                       GENERAL DESCRIPTION




FCC ID: OYK-TX027145-0407
                                                1


                         INTERTEK TESTING SERVICES


1.0   General Description

1.1   Product Description

      The equipment under test (EUT) is a transmitter for a RC Submarine operating at
      27.145 MHz which is controlled by a crystal. The EUT is powered by a 9V battery. The
      EUT has two switches, two control levers and four buttons. The power switch is used to
      switch on and off the device. The band selection switch is used to select the
      communication channel with the RC Submarine. There has three channels available for
      the user. Each channel provides a particular control coding used to control certain
      submarine. The left and right control levers are used to control the propellers on the RC
      Submarine, push both levers up for forward driving, pull both levers down for backward
      driving and push or pull either one of the lever up or down for turning left and right
      directions. The button on the top left side is used to control the Submarine to submerge
      in the water and the button on the top right side is used to control the RC Submarine to
      emerge on the water. The button under the power switch is used to switch on and off the
      headlight on the Submarine. The button under the band selection switch is used to stop
      the Submarine while submerging or emerging.


      The brief circuit description is saved with filename : descri.pdf


1.2   Related Submittal(s) Grants

      The receiver for this transmitter is exempted from the Part 15 technical rules per
      15.101(b).




FCC ID: OYK-TX027145-0407
                                                                                           2


                         INTERTEK TESTING SERVICES



1.3   Test Methodology

      The radiated emission measurements were performed according to the procedures in
      ANSI C63.4 (2001). All measurements were performed in Open Area Test Sites.
      Preliminary scans were performed in the Open Area Test Sites only to determine worst
      case modes. All Radiated tests were performed at an antenna to EUT distance of 3
      meters, unless stated otherwise in the "Justification Section" of this Application.

1.4   Test Facility

      The open area test site and conducted measurement facility used to collect the emission
      data is located at Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. This
      test facility and site measurement data have been fully placed on file with the FCC.




FCC ID: OYK-TX027145-0407
                                                                                         3


                    INTERTEK TESTING SERVICES


                            EXHIBIT 2

                    SYSTEM TEST CONFIGURATION




FCC ID: OYK-TX027145-0407
                                                4


                         INTERTEK TESTING SERVICES


2.0   System Test Configuration

2.1   Justification

      The system was configured for testing in a typical fashion (as a customer would normally
      use it), and in the confines as outlined in ANSI C63.4 (2001).

      The EUT was powered by a new 9V battery during test.

      For maximizing emissions, the EUT was rotated through 360°, the antenna height was
      varied from 1 meter to 4 meters above the ground plane, and the antenna polarization
      was changed. This step by step procedure for maximizing emissions led to the data
      reported in Exhibit 3.0.

      The unit was operated standalone and placed in the center of the turntable.

      The equipment under test (EUT) was configured for testing in a typical fashion (as a
      customer would normally use it). The EUT was placed on a turn table, and the Antenna
      of EUT was fully extended, which enabled the engineer to maximize emissions through
      its placement in the three orthogonal axes.

      For simplicity of testing, the unit was wired to transmit continuously.


2.2   EUT Exercising Software

      There was no special software to exercise the device.


2.3   Special Accessories

      There are no special accessories necessary for compliance of this product.




FCC ID: OYK-TX027145-0407
                                                                                          5


                         INTERTEK TESTING SERVICES



2.4   Equipment Modification

      Any modifications installed previous to testing by Silverlit Toys Manufactory Ltd. will be
      incorporated in each production model sold/leased in the United States.

      No modifications were installed by Intertek Testing Services.

2.5   Support Equipment List and Description

      This product was tested in a standalone configuration.

      All the items listed under section 2.0 of this report are

      Confirmed by:

                    Billy Chow
                    Senior Supervisor
                    Intertek Testing Services
                    Agent for Silverlit Toys Manufactory Ltd.




                                                            Signature

                      May 25, 2005                            Date




FCC ID: OYK-TX027145-0407
                                                                                            6


                    INTERTEK TESTING SERVICES



                                EXHIBIT 3

                            EMISSION RESULTS




FCC ID: OYK-TX027145-0407
                                                7


                        INTERTEK TESTING SERVICES


3.0   Emission Results

      Data is included worst case configuration (the configuration which resulted in the highest
      emission levels). A sample calculation, configuration photographs and data tables of the
      emissions are included.




FCC ID: OYK-TX027145-0407
                                                                                            8


                        INTERTEK TESTING SERVICES


3.1   Field Strength Calculation

      The field strength is calculated by adding the reading on the Spectrum Analyzer to the
      factors associated with preamplifiers (if any), antennas, cables, pulse desensitization and
      average factors (when specified limit is in average and measurements are made with
      peak detectors). A sample calculation is included below.

      FS = RA + AF + CF - AG + PD + AV

      where FS = Field Strength in dBµV/m
                  RA = Receiver Amplitude (including preamplifier) in dBµV
                  CF = Cable Attenuation Factor in dB
                  AF = Antenna Factor in dB
                  AG = Amplifier Gain in dB
                  PD = Pulse Desensitization in dB
                  AV = Average Factor in -dB



      In the radiated emission table which follows, the reading shown on the data table may
      reflect the preamplifier gain. An example of the calculations, where the reading does not
      reflect the preamplifier gain, follows:


      FS = RA + AF + CF - AG + PD + AV




FCC ID: OYK-TX027145-0407
                                                                                             9


                        INTERTEK TESTING SERVICES


3.1   Field Strength Calculation (cont’d)

      Example
      Assume a receiver reading of 62.0 dBµV is obtained. The antenna factor of 7.4 dB and
      cable factor of 1.6 dB is added. The amplifier gain of 29 dB is subtracted. The pulse
      desensitization factor of the spectrum analyzer was 0 dB, and the resultant average
      factor was -10 dB. The net field strength for comparison to the appropriate emission limit
      is 32 dBµV/m. This value in dBµV/m was converted to its corresponding level in µV/m.

      RA = 62.0 dBµV
      AF = 7.4 dB
      CF = 1.6 dB
      AG = 29.0 dB
      PD = 0 dB

      AV = -10 dB

      FS = 62 + 7.4 + 1.6 - 29 + 0 + (-10) = 32 dBµV/m

      Level in µV/m = Common Antilogarithm [(32 dBµV/m)/20] = 39.8 µV/m




FCC ID: OYK-TX027145-0407
                                                                                            10


                        INTERTEK TESTING SERVICES


3.2   Radiated Emission Configuration Photograph

                            Worst Case Radiated Emission

                                      54.290 MHz


      For electronic filing, the worst case radiated emission configuration photograph is saved
      with filename: radiated photos.doc




FCC ID: OYK-TX027145-0407
                                                                                           11


                        INTERTEK TESTING SERVICES


3.3   Radiated Emission Data

      The data on the following page lists the significant emission frequencies, the limit and the
      margin of compliance. Numbers with a minus sign are below the limit.


                             Judgement: Passed by 0.2 dB


      TEST PERSONNEL:




      Signature



      Anthony K. M. Chan, Compliance Engineer
      Typed/Printed Name


      May 25, 2005
      Date




FCC ID: OYK-TX027145-0407
                                                                                              12


                          INTERTEK TESTING SERVICES


Applicant: Silverlit Toys Manufactory Ltd.                        Date of Test: May 19, 2005
Model: Not Applicable (TX)
Mode: TX
Sample: 2/2

                                                  Table 1

                                             Radiated Emissions

                                     Pre-      Antenna Average           Limit at
             Frequency Reading       Amp        factor  Factor Net at 3m   3m           Margin
Polarization   (MHz)   (dBµV)        (dB)        (dB)    (dB)  (dBµV/m) (dBµV/m)         (dB)
     V         27.145   66.4          16        15.4    21.4     44.4     80.0          -35.6
     V         54.290   44.8          16        11.0       -     39.8     40.0           -0.2
     H         81.435   38.6          16         7.0       -     29.6     40.0          -10.4
     H        108.580   31.0          16        14.0       -     29.0     43.5          -14.5
     H        135.713   35.6          16        14.0       -     33.6     43.5           -9.9
     H        162.858   27.4          16        16.0       -     27.4     43.5          -16.1
     H        190.003   27.0          16        16.0       -     27.0     43.5          -16.5


Notes: 1. Peak Detector Data unless otherwise stated.

        2. All measurements were made at 3 meter. Harmonic emissions not detected at the 3
           meter distance were measured at 0.3 meter and an inverse proportional extrapolation
           was performed to compare the signal level to the 3 meter limit. No other harmonic
           emissions than those reported were detected at a test distance of 0.3 meter.

        3. Negative value in the margin column shows emission below limit.

        4. Horn antenna are used for the emission over 1000MHz.

         *Emission within the restricted band meets the requirement of part 15.205. The
         corresponding limit as per 15.209 is based on Quasi peak detector data for
         frequencies below 1000 MHz and peak detector data with average factor for
         frequencies over 1000 MHz.


Test Engineer: Anthony K. M. Chan



FCC ID: OYK-TX027145-0407
                                                                                           13


                    INTERTEK TESTING SERVICES


                            EXHIBIT 4

                     EQUIPMENT PHOTOGRAPHS




FCC ID: OYK-TX027145-0407

                                                14


                        INTERTEK TESTING SERVICES


4.0   Equipment Photographs

      For electronic filing, the photographs are saved with filename:
      external photos.doc and internal photos.doc




FCC ID: OYK-TX027145-0407

                                                                        15


                    INTERTEK TESTING SERVICES

                                EXHIBIT 5

                            PRODUCT LABELLING




FCC ID: OYK-TX027145-0407
                                                16


                        INTERTEK TESTING SERVICES

5.0   Product Labelling

      For electronic filing, the FCC ID label artwork and the label location are saved with
      filename: label.pdf




FCC ID: OYK-TX027145-0407
                                                                                        17


                    INTERTEK TESTING SERVICES

                             EXHIBIT 6

                     TECHNICAL SPECIFICATIONS




FCC ID: OYK-TX027145-0407
                                                18


                        INTERTEK TESTING SERVICES

6.0   Technical Specifications

      For electronic filing, the block diagram and schematics are saved with filename:
      block.pdf and circuit.pdf




FCC ID: OYK-TX027145-0407
                                                                                         19


                    INTERTEK TESTING SERVICES

                             EXHIBIT 7

                        INSTRUCTION MANUAL




FCC ID: OYK-TX027145-0407
                                                20


                       INTERTEK TESTING SERVICES

7.0   Instruction Manual

      For electronic filing, a preliminary copy of the Instruction Manual is saved with
      filename: manual.pdf




FCC ID: OYK-TX027145-0407
                                                                                    21


                    INTERTEK TESTING SERVICES

                            EXHIBIT 8

                   MISCELLANEOUS INFORMATION




FCC ID: OYK-TX027145-0407
                                                22


                       INTERTEK TESTING SERVICES

8.0   Miscellaneous Information

      This miscellaneous information includes details of the measured bandwidth, the test
      procedure and calculation of factors such as pulse desensitization and averaging
      factor.




FCC ID: OYK-TX027145-0407
                                                                                      23


                       INTERTEK TESTING SERVICES

8.1   Measured Bandwidth


      The plot saved in bw.pdf which shows the fundamental emission is confined in the
      specified band. And it also shows that the emission is at least 37 dB below the
      carrier level at the band edge (26.96 and 27.28 MHz). It meets the requirement of
      Section 15.227(b).


                                      Figure 8.1     Bandwidth




FCC ID: OYK-TX027145-0407
                                                                                    24


                        INTERTEK TESTING SERVICES

8.2   Discussion of Pulse Desensitization

      The determination of pulse desensitivity was made in accordance with Hewlett
      Packard Application Note 150-2, Spectrum Analysis ... Pulsed RF.

      The effective period (Teff) was approximately 75 µs for a digital "1" bit, as shown in
      the plots of Exhibit 8.3. With a resolution bandwidth (3 dB) of 100 kHz, the pulse
      desensitivity factor was 0 dB.




FCC ID: OYK-TX027145-0407
                                                                                         25


                        INTERTEK TESTING SERVICES

8.3   Calculation of Average Factor
      (Worst-case : Band Channel C, push left lever up, pull right lever down and press
      right top button)

      Averaging factor in dB = 20 log (duty cycle)

      The specification for output field strengths in accordance with the FCC rules specify
      measurements with an average detector. During testing, a spectrum analyzer
      incorporating a peak detector was used. Therefore, a reduction factor can be
      applied to the resultant peak signal level and compared to the limit for
      measurement instrumentation incorporating an average detector.

      The time period over which the duty cycle is measured is 100 milliseconds, or the
      repetition cycle, whichever is a shorter time frame. The worst case (highest
      percentage on) duty cycle is used for the calculation. The duty cycle is measured
      by placing the spectrum analyzer in zero scan (receiver mode) and linear mode at
      maximum bandwidth (3 MHz at 3 dB down) and viewing the resulting time domain
      signal output from the analyzer on a Tektronix oscilloscope. The oscilloscope is
      used because of its superior time base and triggering facilities.

      A plot of the worst-case duty cycle as detected in this manner are saved with
      filename: af.pdf

      The duty cycle is simply the on-time divided by the period:

      The duration of one cycle = 62.6 ms
      Effective period of the cycle = 150 µs x 2 + 187 µs + 563 µs x 2 + 262 µs x 5 +
                                      225 µs x 8 + 75 µs x 5 + 112 µs x 2
                                    = 5.322 ms

      DC = 5.322 ms / 62.6 ms = 0.08502 or 8.502%


      Therefore, the averaging factor is found by 20 log10 0.08502 = 21.4 dB




FCC ID: OYK-TX027145-0407
                                                                                        26


                        INTERTEK TESTING SERVICES

8.4   Emissions Test Procedures

      The following is a description of the test procedure used by Intertek Testing
      Services in the measurements of transmitters operating under Part 15, Subpart C
      rules.

      The test set-up and procedures described below are designed to meet the
      requirements of ANSI C63.4 - 2001.

      The transmitting equipment under test (EUT) is placed on a wooden turntable
      which is four feet in diameter and approximately one meter in height above the
      ground plane. The antenna of EUT was fully extended. During the radiated
      emissions test, the turntable is rotated and any cables leaving the EUT are
      manipulated to find the configuration resulting in maximum emissions. The antenna
      height and polarization are varied during the testing to search for maximum signal
      levels.

      Detector function for radiated emissions is in peak mode. Average readings, when
      required, are taken by measuring the duty cycle of the equipment under test and
      subtracting the corresponding amount in dB from the measured peak readings. A
      detailed description for the calculation of the average factor can be found in Exhibit
      8.3.

      The frequency range scanned is from the lowest radio frequency signal generated
      in the device which is greater than 9 kHz to the tenth harmonic of the highest
      fundamental frequency or 40 GHz, whichever is lower. For line conducted
      emissions, the range scanned is 150 kHz to 30 MHz.




FCC ID: OYK-TX027145-0407
                                                                                         27


                        INTERTEK TESTING SERVICES

8.4   Emissions Test Procedures (cont'd)


      The EUT is warmed up for 15 minutes prior to the test.

      AC power to the unit is varied from 85% to 115% nominal and variation in the
      fundamental emission field strength is recorded. If battery powered, a new, fully
      charged battery is used.

      Conducted measurements are made as described in ANSI C63.4 - 2001.

      The IF bandwidth used for measurement of radiated signal strength was 10 kHz for
      emission below 30 MHz and 120 kHz for emission from 30 MHz to 1000 MHz.
      Where pulsed transmissions of short enough pulse duration warrant, a greater
      bandwidth is selected according to the recommendations of Hewlett Packard
      Application Note 150-2. A discussion of whether pulse desensitivity is applicable to
      this unit is included in this report (See Exhibit 8.2). Above 1000 MHz, a resolution
      bandwidth of 1 MHz is used.

      Transmitter measurements are normally conducted at a measurement distance of
      three meters. However, to assure low enough noise floor in the restricted bands
      and above 1 GHz, signals are acquired at a distance of one meter or less. All
      measurements are extrapolated to three meters using inverse scaling, but those
      measurements taken at a closer distance are so marked.

      When determining the test result, the Measurement Uncertainty of the test has
      been considered.




FCC ID: OYK-TX027145-0407
                                                                                       28



Document Created: 2005-05-25 15:20:07
Document Modified: 2005-05-25 15:20:07

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC