Test Report

FCC ID: OYK-FCC82419

Test Report

Download: PDF
FCCID_3845213

                                                                                                                                            2/F., Garment Centre,
                                                                                                                                            576 Castle Peak Road, Kowloon,
                                                                                                                                            Hong Kong.

                                                                                                                                            Telephone:    (852) 2173 8888
                                                                                                                                            Facsimile:    (852) 2785 5487
                                                                                                                                            www.intertek.com


TEST REPORT

Report No.: 17080818HKG-002

Silverlit Toys Manufactory Ltd.

Application For Certification
(Original Grant)

FCC ID: OYK-FCC82419


Transceiver




PREPARED AND CHECKED BY:                                                                            APPROVED BY:

                                                                                                                      Digitally signed
                                                                                                                      by Kenneth Wong
                                                                                                                      Location: Intertek
                                                                                                                      Testing Services
                                                                                                                      Hong Kong Ltd.
Signed On File
Josie Yao                                                                                           Wong Kwok Yeung, Kenneth
Engineer                                                                                            Senior Lead Engineer
                                                                                                    Date: September 04, 2017




Intertek’s standard Terms and Conditions can be obtained at our website http://www.intertek.com/terms/.
The test report only allows to be revised within the retention period unless further standard or the requirement was noticed
This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited
to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or
damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek
name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results
in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification
program.
© 2017 Intertek

                                                                                  Page 1 of 20


                                                                    Silverlit Toys Manufactory Ltd.
                                                                    Intertek Report: No:
                                                                    17080818HKG-002



TEST REPORT

GENERAL INFORMATION

Grantee:                    Silverlit Toys Manufactory Ltd.
Grantee Address:            Room 1701-03, World Trade Centre,
                            280 Gloucester Road, Causeway Bay,
                            Hong Kong.
Contact Person:             May Choi
Tel:                        2834-4168
Fax:                        2834-8797
e-mail:                     N/A
Manufacturer:               Silverlit Toys Manufactory Ltd.
Manufacturer Address:       Room 1701-03, World Trade Centre,
                            280 Gloucester Road, Causeway Bay,
                            Hong Kong.
Brand Name:                 Spy Rover
Model:                      82419
Type of EUT:                Transceiver
Description of EUT:         Spy Rover
Serial Number:              N/A
FCC ID:                     OYK-FCC82419
Date of Sample Submitted:   August 14, 2017
Date of Test:               August 14, 2017 to September 01, 2017
Report No.:                 17080818HKG-002
Report Date:                September 04, 2017
Environmental Conditions:   Temperature: +10 to 40°C
                            Humidity: 10 to 90%




                                     Page 2 of 20


                                                                               Silverlit Toys Manufactory Ltd.
                                                                               Intertek Report: No:
                                                                               17080818HKG-002



TEST REPORT

SUMMARY OF TEST RESULT

                  TEST SPECIFICATION                               REFERENCE                    RESULTS
Radiated Emission
                                                                 15.249, 15.209                    Pass
Radiated Emission on the Bandedge
Radiated Emission in Restricted Bands                                15.205                        Pass

The equipment under test is found to be complying with the following standards:
FCC Part 15, October 1, 2015 Edition




Note: 1. The EUT uses a permanently attached antenna which, in accordance to section 15.203, is
         considered sufficient to comply with the pervisions of this section.
      2. Pursuant to FCC part 15 Section 15.215(c), the 20 dB bandwidth of the emission was contained
         within the frequency band designated (mentioned as above) which the EUT operated. The
         effects, if any, from frequency sweeping, frequency hopping, other modulation techniques and
         frequency stability over excepted variations in temperature and supply voltage were considered.


                                               Page 3 of 20


                                                                                                          Silverlit Toys Manufactory Ltd.
                                                                                                          Intertek Report: No:
                                                                                                          17080818HKG-002



TEST REPORT

TABLE OF CONTENTS

1.0   GENERAL DESCRIPTION ............................................................................................ 5
  1.1   Product Description .............................................................................................. 5
  1.2   Related Submittal(s) Grants ................................................................................... 5
  1.3   Test Methodology ................................................................................................ 5
  1.4   Test Facility .......................................................................................................... 5

2.0   SYSTEM TEST CONFIGURATION ................................................................................. 6
  2.1   Justification ......................................................................................................... 6
  2.2   EUT Exercising Software ........................................................................................ 6
  2.3   Special Accessories ............................................................................................... 6
  2.4   Measurement Uncertainty ..................................................................................... 6
  2.5   Support Equipment List and Description .................................................................. 6

3.0   EMISSION RESULTS .................................................................................................. 7
  3.1   Field Strength Calculation ...................................................................................... 7
  3.2   Radiated Emission Configuration Photograph ........................................................... 8
  3.3   Radiated Emission Data ......................................................................................... 8

4.0       EQUIPMENT PHOTOGRAPHS................................................................................... 13

5.0       PRODUCT LABELLING ............................................................................................. 13

6.0       TECHNICAL SPECIFICATIONS.................................................................................... 13

7.0       INSTRUCTION MANUAL.......................................................................................... 13

8.0   MISCELLANEOUS INFORMATION ............................................................................. 14
  8.1   Radiated Emission on the Bandedge...................................................................... 14
  8.2   Discussion of Pulse Desensitization ....................................................................... 15
  8.3   Calculation of Average Factor ............................................................................... 15
  8.4   Emissions Test Procedures ................................................................................... 17

9.0       EQUIPMENT LIST ................................................................................................... 20




                                                               Page 4 of 20


                                                                                     Silverlit Toys Manufactory Ltd.
                                                                                     Intertek Report: No:
                                                                                     17080818HKG-002



TEST REPORT

1.0   GENERAL DESCRIPTION

1.1   Product Description

      The EUT is a 2.4GHz transceiver with a camera. The EUT is powered by 6 x 1.5V AA batteries.
      After switching on the EUT and being paired with controller, the car can be controlled to move
      forward/backward and turn left/ right.
      It is operating at the frequency range of 2410.875-2468.25MHz with 3.375 MHz channel
      spacing and can also connect to controller with the function of taking photo and recording
      video.


      Antenna Type: Internal, Integral

      For electronic filing, the brief circuit description is saved with filename: descri.pdf.


1.2   Related Submittal(s) Grants

      The Certification procedure of transceiver (Controller) for this transceiver (RC Car) with FCC ID:
      OYK-TX0002G4-1704 is being processed as the same time of this application.



1.3   Test Methodology

      Radiated emission measurements were performed according to the procedures in ANSI C63.10
      (2013). All radiated measurements were performed in an 3m Chamber. Preliminary scans
      were performed in the 3m Chamber only to determine worst case modes. All radiated tests
      were performed at an antenna to EUT distance of 3 meters, unless stated otherwise in the
      “Justification Section” of this Application.


1.4   Test Facility

      The 3m Chamber facility used to collect the radiated data is located at Workshop No. 3, G/F.,
      World-Wide Industrial Centre, 43-47 Shan Mei Street, Fo Tan, Sha Tin, N.T., Hong Kong. This test
      facility and site measurement data have been placed on file with the FCC.




                                                  Page 5 of 20


                                                                               Silverlit Toys Manufactory Ltd.
                                                                               Intertek Report: No:
                                                                               17080818HKG-002



TEST REPORT

2.0   SYSTEM TEST CONFIGURATION
2.1   Justification

      The system was configured for testing in a typical fashion (as a customer would normally use it),
      and in the confines as outlined in ANSI C63.10 (2013).

      The device was powered by new 6 x 1.5V AA batteries.

      For maximizing emissions, the EUT was rotated through 360°, the antenna height was varied from
      1 meter to 4 meters above the ground plane, and the antenna polarization was changed. This
      step by step procedure for maximizing emissions led to the data reported in Exhibit 3.0.

      The unit was operated standalone and placed in the center of the turntable.

      The equipment under test (EUT) was configured for testing in a typical fashion (as a customer
      would normally use it). The EUT was mounted to a plastic stand if necessary and placed on the
      wooden turntable, which enabled the engineer to maximize emissions through its placement in
      the three orthogonal axes.


2.2   EUT Exercising Software

      There was no special software to exercise the device. Once the unit is powered up, it transmits
      the RF signal continuously.


2.3   Special Accessories

      There are no special accessories necessary for compliance of this product.


2.4   Measurement Uncertainty

      When determining of the test conclusion, the Measurement Uncertainty of test has been
      considered.

      Uncertainty and Compliance - Unless the standard specifically states that measured values are to
      be extended by the measurement uncertainty in determining compliance, all compliance
      determinations are based on the actual measured value.


2.5   Support Equipment List and Description

      N/A.




                                               Page 6 of 20


                                                                              Silverlit Toys Manufactory Ltd.
                                                                              Intertek Report: No:
                                                                              17080818HKG-002



TEST REPORT

3.0   EMISSION RESULTS

      Data is included of the worst case configuration (the configuration which resulted in the highest
      emission levels). A sample calculation, configuration photographs and data tables of the
      emissions are included.


3.1   Field Strength Calculation

      The field strength is calculated by adding the Antenna Factor and Cable Factor, and subtracting
      the Amplifier Gain (if any), Average Factor (optional) from the measured reading. The basic
      equation with a sample calculation is as follows:
      FS = RA + AF + CF - AG - AV
      where FS = Field Strength in dBµV/m
                     RA = Receiver Amplitude (including preamplifier) in dBµV
                     CF = Cable Attenuation Factor in dB
                     AF = Antenna Factor in dB
                     AG = Amplifier Gain in dB
                     AV = Average Factor in dB

      In the following table(s), the reading shown on the data table reflects the preamplifier gain. An
      example for the calculations in the following table is as follows:
      FS = RR + LF
      where          FS = Field Strength in dBµV/m
                     RR = RA - AG - AV in dBµV
                     LF = CF + AF in dB

      Assume a receiver reading of 52.0 dBµV is obtained. The antenna factor of 7.4 dB and cable
      factor of 1.6 dB are added. The amplifier gain of 29 dB and average factor of 5 dB are
      subtracted, giving a field strength of 27 dBµV/m. This value in dBµV/m was converted to its
      corresponding level in µV/m.

      RA = 52.0 dBµV/m
      AF = 7.4 dB                          RR = 18.0 dBµV
      CF = 1.6 dB                          LF = 9.0 dB
      AG = 29.0 dB
      AV = 5.0 dB
      FS = RR + LF
      FS = 18 + 9 = 27 dBµV/m

      Level in µV/m = Common Antilogarithm [(27 dBµV/m)/20] = 22.4 µV/m




                                              Page 7 of 20


                                                                               Silverlit Toys Manufactory Ltd.
                                                                               Intertek Report: No:
                                                                               17080818HKG-002



TEST REPORT

3.2   Radiated Emission Configuration Photograph

      The worst case in radiated emission was found at 2400 MHz

      For electronic filing, the worst case radiated emission configuration photographs are saved with
      filename: radiated photos.pdf.


3.3   Radiated Emission Data

      The data on the following page lists the significant emission frequencies, the limit and the margin
      of compliance. Numbers with a minus sign are below the limit.

      Judgment: Passed by 1.0 dB




                                              Page 8 of 20


                                                                                      Silverlit Toys Manufactory Ltd.
                                                                                      Intertek Report: No:
                                                                                      17080818HKG-002



TEST REPORT

RADIATED EMISSIONS
Model: 82419
Date of Test: September 01, 2017
Worst-Case Operating Mode: Transmitting

                                                    Table 1
                              Pursuant to FCC Part 15 Section 15.249 Requirement

Lowest Channel
                               Pre-Amp Antenna   Net at  Average Calculated   Average Limit
Polari- Frequency   Reading      Gain   Factor 3m - Peak Factor    at 3m          at 3m          Margin
zation     (MHz)    (dBµV)       (dB)    (dB)  (dBµV/m)   (dB)   (dBµV/m)       (dBµV/m)          (dB)
  H      2410.875    113.4        33     29.4    109.8    20.6      89.2           94.0           -4.8
  H      2400.000     76.6        33     29.4     73.0    20.6      52.4           54.0           -1.6
  H      4821.750    51.9         33     34.9    53.8     20.6     33.2           54.0           -20.8
  H      7232.625     42.3        33     37.9     47.2    20.6      26.6           54.0          -27.4
  H      9643.500     41.4        33     40.4     48.8    20.6      28.2           54.0          -25.8
  H     12054.375    43.6         33     40.5    51.1     20.6     30.5           54.0           -23.5
  H     14465.250     45.7        33     40.0     52.7    20.6      32.1           54.0          -21.9

                                     Pre-Amp    Antenna        Net at    Peak Limit
 Polari-   Frequency    Reading        Gain      Factor      3m - Peak     at 3m              Margin
 zation       (MHz)     (dBµV)         (dB)       (dB)       (dBµV/m)    (dBµV/m)              (dB)
   H        2410.875     113.4          33        29.4         109.8       114.0                -4.2
   H        2400.000      76.6          33        29.4          73.0        74.0                -1.0
   H       4821.750      51.9           33        34.9         53.8        74.0               -20.2
   H        7232.625      42.3          33        37.9          47.2        74.0               -26.8
   H        9643.500      41.4          33        40.4          48.8        74.0               -25.2
   H       12054.375     43.6           33        40.5         51.1        74.0               -22.9
   H       14465.250      45.7          33        40.0          52.7        74.0               -21.3


NOTES:     1. Peak Detector Data unless otherwise stated.

           2. All measurements were made at 3 meters. Harmonic emissions not detected at the 3-
              meter distances were measured at 0.3-meter and an inverse proportional extrapolation
              was performed to compare the signal level to the 3-meter limit. No other harmonic
              emissions than those reported were detected at a test distance of 0.3-meter.

           3. Negative sign in the column shows value below limit.

           4. Horn antenna is used for the emission over 1000MHz. (for Over 1GHz)

           5. Emission (the row indicated by bold italic) within the restricted band meets the requirement
              of FCC Part 15 Section 15.205.

           6. Measurement Uncertainty is ±5.3dB at a level of confidence of 95%.




                                                  Page 9 of 20


                                                                                       Silverlit Toys Manufactory Ltd.
                                                                                       Intertek Report: No:
                                                                                       17080818HKG-002



TEST REPORT


Model: 82419
Date of Test: September 01, 2017
Worst-Case Operating Mode: Transmitting

                                                    Table 2
                              Pursuant to FCC Part 15 Section 15.249 Requirement

Middle Channel
                               Pre-Amp Antenna   Net at  Average Calculated   Average Limit
Polari- Frequency   Reading      Gain   Factor 3m - Peak Factor    at 3m          at 3m           Margin
zation     (MHz)    (dBµV)       (dB)    (dB)  (dBµV/m)   (dB)   (dBµV/m)       (dBµV/m)           (dB)
  H      2437.875    110.7        33     29.4    107.1    20.6      86.5           94.0            -7.5
  H     4875.750     48.4         33     34.9    50.3     20.6     29.7           54.0            -24.3
  H     7313.625     42.5         33     37.9    47.4     20.6     26.8           54.0            -27.2
  H      9751.500     41.1        33     40.4     48.5    20.6      27.9           54.0           -26.1
  H     12189.375    43.7         33     40.5    51.2     20.6     30.6           54.0            -23.4
  H     14627.250     47.0        33     38.4     52.4    20.6      31.8           54.0           -22.2

                                     Pre-Amp    Antenna         Net at    Peak Limit
 Polari-   Frequency    Reading        Gain      Factor       3m - Peak     at 3m              Margin
 zation       (MHz)     (dBµV)         (dB)       (dB)        (dBµV/m)    (dBµV/m)              (dB)
   H        2437.875     110.7          33        29.4          107.1       114.0                -6.9
   H       4875.750      48.4           33        34.9          50.3        74.0               -23.7
   H       7313.625      42.5           33        37.9          47.4        74.0               -26.6
   H        9751.500      41.1          33        40.4           48.5        74.0               -25.5
   H       12189.375     43.7           33        40.5          51.2        74.0               -22.8
   H       14627.250      47.0          33        38.4           52.4        74.0               -21.6


NOTES:     1. Peak Detector Data unless otherwise stated.

           2. All measurements were made at 3 meters. Harmonic emissions not detected at the 3-
              meter distances were measured at 0.3-meter and an inverse proportional extrapolation
              was performed to compare the signal level to the 3-meter limit. No other harmonic
              emissions than those reported were detected at a test distance of 0.3-meter.

           3. Negative sign in the column shows value below limit.

           4. Horn antenna is used for the emission over 1000MHz. (for Over 1GHz)

           5. Emission (the row indicated by bold italic) within the restricted band meets the requirement
              of FCC Part 15 Section 15.205.

           6. Measurement Uncertainty is ±5.3dB at a level of confidence of 95%.




                                                  Page 10 of 20


                                                                                       Silverlit Toys Manufactory Ltd.
                                                                                       Intertek Report: No:
                                                                                       17080818HKG-002



TEST REPORT


Model: 82419
Date of Test: September 01, 2017
Worst-Case Operating Mode: Transmitting

                                                    Table 3
                              Pursuant to FCC Part 15 Section 15.249 Requirement

Highest Channel
                               Pre-Amp Antenna   Net at  Average Calculated   Average Limit
Polari- Frequency   Reading      Gain   Factor 3m - Peak Factor    at 3m          at 3m           Margin
zation     (MHz)    (dBµV)       (dB)    (dB)  (dBµV/m)   (dB)   (dBµV/m)       (dBµV/m)           (dB)
  H      2468.250    108.9        33     29.4    105.3    20.6      84.7           94.0            -9.3
  H      2483.500    69.1         33     29.4    65.5     20.6     44.9           54.0             -9.1
  H      4936.500    46.8         33     34.9    48.7     20.6     28.1           54.0            -25.9
  H      7404.750    42.1         33     37.9    47.0     20.6     26.4           54.0            -27.6
  H      9873.000     41.2        33     40.4     48.6    20.6      28.0           54.0           -26.0
  H     12341.250    43.8         33     40.5    51.3     20.6     30.7           54.0            -23.3
  H     14809.500     47.1        33     38.4     52.5    20.6      31.9           54.0           -22.1

                                     Pre-Amp    Antenna         Net at    Peak Limit
 Polari-   Frequency    Reading        Gain      Factor       3m - Peak     at 3m              Margin
 zation       (MHz)     (dBµV)         (dB)       (dB)        (dBµV/m)    (dBµV/m)              (dB)
   H        2468.250     108.9          33        29.4          105.3       114.0                -8.7
   H       2483.500      69.1           33        29.4          65.5        74.0                 -8.5
   H       4936.500      46.8           33        34.9          48.7        74.0               -25.3
   H       7404.750      42.1           33        37.9          47.0        74.0               -27.0
   H        9873.000      41.2          33        40.4           48.6        74.0               -25.4
   H       12341.250     43.8           33        40.5          51.3        74.0               -22.7
   H       14809.500      47.1          33        38.4           52.5        74.0               -21.5


NOTES:     1. Peak Detector Data unless otherwise stated.

           2. All measurements were made at 3 meters. Harmonic emissions not detected at the 3-
              meter distances were measured at 0.3-meter and an inverse proportional extrapolation
              was performed to compare the signal level to the 3-meter limit. No other harmonic
              emissions than those reported were detected at a test distance of 0.3-meter.

           3. Negative sign in the column shows value below limit.

           4. Horn antenna is used for the emission over 1000MHz.

           5. Emission (the row indicated by bold italic) within the restricted band meets the requirement
              of FCC Part 15 Section 15.205.

           6. Measurement Uncertainty is ±5.3dB at a level of confidence of 95%.




                                                  Page 11 of 20


                                                                               Silverlit Toys Manufactory Ltd.
                                                                               Intertek Report: No:
                                                                               17080818HKG-002



TEST REPORT


Model: 82419
Date of Test: September 01, 2017
Worst-Case Operating Mode: Video Recording

                                              Table 4
                        Pursuant to FCC Part 15 Section 15.209 Requirement

                                             Pre- Antenna    Net     Limit
                 Frequency      Reading      amp Factor     at 3m    at 3m                         Margin
 Polarization      (MHz)        (dBµV)       (dB)  (dB)   (dBµV/m) (dBµV/m)                         (dB)
      V           192.000         40.4        16   16.0      40.4     43.5                          -3.1
      H           431.940         29.5        16   25.0      38.5     46.0                          -7.5
      H           456.071         29.8        16   26.0      39.8     46.0                          -6.2
      H           575.996         26.3        16   28.0      38.3     46.0                          -7.7
      H           600.006         25.5        16   29.0      38.5     46.0                          -7.5
      H           624.015        25.2         16   29.0     38.2     46.0                           -7.8

NOTES:   1. Peak Detector Data unless otherwise stated.

         2. All measurements were made at 3 meters. Harmonic emissions not detected at the 3-
            meter distances were measured at 0.3-meter and an inverse proportional extrapolation
            was performed to compare the signal level to the 3-meter limit. No other harmonic
            emissions than those reported were detected at a test distance of 0.3-meter.

         3. Negative sign in the column shows value below limit.

         4. Horn antenna is used for the emission over 1000MHz.

         5. Emission (the row indicated by bold italic) within the restricted band meets the requirement
            of FCC Part 15 Section 15.205.

         6. Measurement Uncertainty is ±5.3dB at a level of confidence of 95%.




                                              Page 12 of 20


                                                                               Silverlit Toys Manufactory Ltd.
                                                                               Intertek Report: No:
                                                                               17080818HKG-002



TEST REPORT

4.0   EQUIPMENT PHOTOGRAPHS

      For electronic filing, the photographs are saved with filename: external photos.pdf and internal
      photos.pdf.


5.0   PRODUCT LABELLING

      For electronics filing, the FCC ID label artwork and the label location are saved with filename:
      label.pdf.


6.0   TECHNICAL SPECIFICATIONS

      For electronic filing, the block diagram and schematic of the tested EUT are saved with filename:
      block.pdf and circuit.pdf respectively.


7.0   INSTRUCTION MANUAL

      For electronic filing, a preliminary copy of the Instruction Manual is saved with filename:
      manual.pdf.

      This manual will be provided to the end-user with each unit sold/leased in the United States.




                                              Page 13 of 20


                                                                             Silverlit Toys Manufactory Ltd.
                                                                             Intertek Report: No:
                                                                             17080818HKG-002



TEST REPORT

8.0   MISCELLANEOUS INFORMATION

      The miscellaneous information includes details of the test procedure and measured bandwidth /
      calculation of factor such as pulse desensitization and averaging factor (calculation and timing
      diagram).


8.1   Radiated Emission on the Bandedge

      The test data of bandedge emissions were shown on the above radiated emissions table 1 & table
      3 respectively.

      The resultant field strength meets the general radiated emission limit in Section 15.209, which
      does not exceed 74 dBµV/m (Peak Limit) and 54 dBµV/m (Average Limit).

      Emissions radiated outside of the specified frequency bands, except harmonics, are attenuated by
      50dB below the level of the fundamental or to the general radiated emissions limits in
      Section 15.209 , whichever is the lesser attenuation, which meet the requirement of
      part 15.249(d).




                                             Page 14 of 20


                                                                               Silverlit Toys Manufactory Ltd.
                                                                               Intertek Report: No:
                                                                               17080818HKG-002



TEST REPORT

      Peak Measurement



8.2   Discussion of Pulse Desensitization

      Pulse desensitivity is not applicable for this device. The effective period (Teff) is approximately
      4.64ms for a digital “1” bit which illustrated on technical specification, with a resolution
      bandwidth (3dB) of 1MHz, so the pulse desensitivity factor is 0dB.


8.3   Calculation of Average Factor

      The duty cycle is simply the on-time divided by the period:

      The duration of one cycle = 100ms

      Effective period of the cycle = 2*4.64 = 9.28ms

      DC = 9.28/100 = 0.0928

      Therefore, the averaging factor is found by 20log 0.0928 = -20.6dB.




                                              Page 15 of 20


                                                                                                            Silverlit Toys Manufactory Ltd.
                                                                                                            Intertek Report: No:
                                                                                                            17080818HKG-002



TEST REPORT

Average Factor
                                                               RBW 3 MHz
                                                               VBW 10 MHz
              Ref     0 dBm             * Att   30 dB          SWT 120 ms
               0

                                                                                                       A
               -10
                                                                                                      SGL
       1 PK
       VIEW                                                                                           TRG
               -20



               -30      TRG -31 dBm

                                                                                                      PS
               -40



               -50

                                                                                                      3DB
               -60                                                                                    AC



               -70



               -80



               -90

                                                                                     T1
               -100

              Center 2.410875 GHz                       12 ms/




                                                               RBW 3 MHz       Delta 2 [T1 ]
                                                               VBW 10 MHz                  0.37 dB
              Ref     0 dBm             * Att   30 dB          SWT 10 ms               4.640000 ms
               0                                                               Marker 1 [T1 ]
                                                                                         -32.88 dBm
                                                                                       0.000000 s      A
               -10
                                                                                                      SGL
       1 PK
       MAXH                                                                                           TRG
               -20



              1 -30                                     2
                        TRG -33.7 dBm
                                                                                                      PS
               -40



               -50

                                                                                                      3DB
               -60                                                                                    AC



               -70



               -80



               -90


               -100

              Center 2.410875 GHz                           1 ms/




                                                               Page 16 of 20


                                                                               Silverlit Toys Manufactory Ltd.
                                                                               Intertek Report: No:
                                                                               17080818HKG-002



TEST REPORT

8.4   Emissions Test Procedures

      The following is a description of the test procedure used by Intertek Testing Services Hong Kong
      Ltd. in the measurements of transmitter operating under the Part 15, Subpart C rules.

      The transmitting equipment under test (EUT) is placed on a wooden turntable which is four feet in
      diameter and approximately 0.8m in height above the ground plane for emission measurement at
      or below 1GHz and 1.5m in height above the ground plane for emission measurement above
      1GHz. During the radiated emissions test, the turntable is rotated and any cables leaving the EUT
      are manipulated to find the configuration resulting in maximum emissions. The EUT is adjusted
      through all three orthogonal axis to obtain maximum emission levels. The antenna height and
      polarization are also varied during the testing to search for maximum signal levels. The height of
      the antenna is varied from one to four meters.

      Detector function for radiated emissions is in peak mode. Average readings, when required, are
      taken by measuring the duty cycle of the equipment under test and subtracting the corresponding
      amount in dB from the measured peak readings. A detailed description for the calculation of the
      average factor can be found in Exhibit 8.3.

      The frequency range scanned is from the lowest radio frequency signal generated in the device
      which is greater than 9 kHz to the tenth harmonic of the highest fundamental frequency or 40
      GHz, whichever is lower.




                                             Page 17 of 20


                                                                               Silverlit Toys Manufactory Ltd.
                                                                               Intertek Report: No:
                                                                               17080818HKG-002



TEST REPORT

8.4   Emissions Test Procedures (cont’d)

      The EUT is warmed up for 15 minutes prior to the test.

      AC power to the unit is varied from 85% to 115% nominal and variation in the fundamental
      emission field strength is recorded. If battery powered, a new, fully charged battery is used.

      Conducted measurements were made as described in ANSI C63.10 (2013).

      The IF bandwidth used for measurement of radiated signal strength was 100 kHz or greater when
      frequency is below 1000 MHz. Where pulsed transmissions of short enough pulse duration
      warrant, a greater bandwidth is selected according to the recommendations of Hewlett Packard
      Application Note 150-2. A discussion of whether pulse desensitivity is applicable to this unit is
      included in this report (See Exhibit 8.1). Above 1000 MHz, a resolution bandwidth of 3 MHz is
      used.

      Transmitter measurements are normally conducted at a measurement distance of three
      meters. However, to assure low enough noise floor in the forbidden bands and above 1 GHz,
      signals are acquired at a distance of one meter or less. All measurements are extrapolated to three
      meters using inverse scaling, unless otherwise reported. Measurements taken at a closer
      distance are so marked.




                                              Page 18 of 20


                                                                                   Silverlit Toys Manufactory Ltd.
                                                                                   Intertek Report: No:
                                                                                   17080818HKG-002



TEST REPORT

8.4.1   Radiated Emission Test Setup (For 1GHz Or Above)

        The figure below shows the test setup, which is utilized to make these measurements.


                                                                     Antenna
                                                    1.0~4.0m         Tower


                                          3m                              Receiver
                                                                          Antenna
                            E
                            U
                            T




             0.8m

                    Ground Plane
         3m Chamber                                       □

                                                                    RF Test
                                                                    Receiver



                                Test setup of radiated emissions up to 1GHz




                                                                     Antenna
                                                    1.0~4.0m         Tower


                                          3m                              Receiver
                            E
                                                                          Antenna
                            U
                            T




             1.5m

                    Ground Plane
                                                          □

                                                                    RF Test Spectrum
                                                                    Analyzer




                                Test setup of radiated emissions above 1GHz




                                                Page 19 of 20


                                                                            Silverlit Toys Manufactory Ltd.
                                                                            Intertek Report: No:
                                                                            17080818HKG-002



TEST REPORT

9.0    EQUIPMENT LIST

1)   Radiated Emissions Test
EQUIPMENT                 EMI Test Receiver          Spectrum Analyzer           Double Ridged
                                                                                 Guide Antenna
Registration No.              EW-3156                         EW-3110               EW-0194
Manufacturer                     R&S                             R&S                 EMCO
Model No.                      ESR26                           FSP30                  3115
Calibration Date            Dec. 06, 2016                   Feb. 06, 2017         Aug. 10, 2016
Calibration Due Date        Dec. 06, 2017                   Feb. 06, 2018         Feb. 10, 2018

EQUIPMENT                 Biconical Antenna         Log Periodic Antenna
Registration No.              EW-0571                     EW-0447
Manufacturer                    EMCO                       EMCO
Model No.                       3104C                       3146
Calibration Date             May 18, 2016               May 18, 2016
Calibration Due Date        Nov. 18, 2017               Nov. 18, 2017

2)      Conductive Measurement Test
EQUIPMENT                 SPECTRUM ANALYZER
Registration No.                EW-2249
Manufacturer                       R&S
Model No.                        FSP30
Calibration Date              Dec. 23, 2016
Calibration Due Date          Nov. 27, 2017

                                    END OF TEST REPORT




                                            Page 20 of 20



Document Created: 2017-09-19 14:47:30
Document Modified: 2017-09-19 14:47:30

© 2024 FCC.report