Users Manual

FCC ID: OXW-PA0002

Users Manual

Download: PDF
FCCID_1773175

Device Solutions
Collector & Sensor
Installation Instructions




                            Revision History: PRELIMINARY


FCC Caution:

Changes or modifications not expressly approved by Device Solutions could void the user’s authority to operate
this equipment.

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant
to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception, which can be determined by turning
the equipment off and on, the user is encouraged to try to correct the interference by one or more of the
following measures:

      Reorient or relocate the receiving antenna.
      Increase the separation between the equipment and receiver.
      Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
      Consult the dealer or an experienced radio/TV technician for help.


Collector Installation

1. Provision the Collector in the server                      4. Reinstall the four 3/8” #4 screws into the corners of
2. Remove the four 3/8” #4 screws into the corners of            the enclosure top that fasten it to the enclosure
   the enclosure top that fasten it to the enclosure             base.
   base.                                                      5. Attach the enclosure to a surface. The best RF
3. Connect the battery                                           performance is obtained by mounting the Collector
                                                                 to a vertical service.
                                                              6. Connect external power to the collector


Sensor Installation

1. Remove the screws that hold the top of the Sensor's          d. Place the Sensor within 50 feet line of sight of the
    enclosure to the base                                          Collector
2. Verify the signal strength at the Sensor                     e. Wait for the Sensor's internal LED to illuminate
  a. Open the Collector press the button to enter                  (up to 1 minute)
      "install mode".                                           f. The color of the LED indicates the following (red –
  b. Wait for the internal green LED to illuminate.                poor signal quality, yellow – moderate signal
  c. Reboot the Sensor by removing and re‐installing               quality, green good signal quality)
      the 9 volt battery


g. Move the Collector and/or Sensor until the Sensor     3. Loosen the nut from the cable restraint shown
   displays a good signal condition for at least 5           above
   consecutive seconds                                   4. Pass the transducer wires through the cable
h. Repeat c through g for each sensor                        restraint
i. Disable "install mode" for the Collector by           5. Tighten the cable restraint nut to the cable restraint
   pressing the button on the collector again (if this   6. Attach the transducer wires to the terminal blocks.
   step is forgotten the collector will exit install         This connection depends on the type of transducer
   mode in one hour)                                         used. See the appendix for an example.
j. Turn off each Sensor by removing the 9 volt           7. The total length of the transducer cable must be
   battery                                                   less than 10 feet
                                                         8. Install the 9 volt battery in the sensor
                                                         9. Re‐install the screws that hold the top of the
                                                             enclosure to the base
                                                         10. Attach the enclosure to a surface. The best RF
                                                             performance is obtained by mounting the Sensor
                                                             vertically.


     Appendix:

Ashcroft Pressure Transducer Installation




Bare wire (shield drain wire) from the transducer is
unused.